• Title/Summary/Keyword: 맴브레인

Search Result 11, Processing Time 0.031 seconds

Fabrication on Microheater Flow Sensors Using Membrane Structure and Its Characteristics (맴브레인 구조를 이용한 미세발열체형 유량센서의 제작과 그 특성)

  • 정귀상;노상수
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.11
    • /
    • pp.996-1000
    • /
    • 1998
  • This paper describes the characteristics of Pt microheater using aluminum oxide films as medium layer and its application to flow sensors. Pt microheater have heating temperature of $390^{\circ}C$ at heating power of 1.2 W. Output voltages of flow sensors which were fabricated by integrating sensing-part with heating-part increase as gas flow rate and its conductivity increase. At $O_2$ flow rate of 2000 sccm, heating power of 0.8 W, output voltage of flow sensor is 101 mV under bridge-applied voltage of 5 V.

  • PDF

Present Status and Prospect of LNG Strorage Tank (액화천연가스 저장탱크의 현황 및 전망)

  • 홍성호
    • Journal of Welding and Joining
    • /
    • v.13 no.3
    • /
    • pp.1-7
    • /
    • 1995
  • 1992년 9월 현재 전 세계적으로 운전 중(건설포함)인 액화 및 인수기지의 LNG 저장탱크는 지상식-이중벽 금속 탱크, 지상식-맴브레인 PC 탱크, 지상식-자립식 내부탱크/PC 외부탱크, 피드식-RC(Reinforced Concrete) 보강둑 탱크, 피트식-이중벽 금속탱크, 피트식-자립식 내부탱크/PC 외부탱크 및 지하식 탱크의 7가지 유형으로 나 타낼 수 있다. 또한 액화천연가스를 저장하는 내부탱크 소재에 따라 9%Ni강 및 MEMBRANE(SUS304) 형식으로 대별할 수 있다. MEMBRANE 저장탱크 형식의 핵심기술인 MEMBRANE은 -162.deg.C의 LNG에 의한 열수축팽창에 견딜 수 있도록 스테인레스강판 (SUS304)을 사용하여 기하학적으로 특이한 주름진 형상을 갖도록 설계되었으며 주름 형상에 따라 프랑스의 테크니가즈(Technigaz), 일본의 가와사끼(Kawasaki). 미쓰비시 (Mitsubishi), 이시가와지마하리마(Ishikawajima-Harima)사의 멤브레인과 세계에서 3번째로 한국가스공사 연구개발원이 개발한 링디식 멤브레인으로 구별할 수 있다. 본 해설에서는 국내의 전국 천연가스 공급사업계획 및 건설현황을 검토하고 최근 전 세계적으로 널리 사용되고 있는 액화천연가스 저장탱크의 종류를 용량별, 년도별로 분석하여 전세계의 액화천연가스 저장탱크에 관해 소개 하겠다.

  • PDF

Efficiency Analysis of Thermal Transpiration According to Knudsen Number for Application to Micro-propulsion System (마이크로 추진장치에 적용을 위한 누센수에 따른 열적발산원리의 효율분석)

  • Jung, Sung-Chul;Huh, Hwan-Il
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.5
    • /
    • pp.483-490
    • /
    • 2008
  • Minimization of nozzle induces many flow losses in micro-propulsion system. In this study, we studied about thermal transpiration based micro propulsion system to overcome these losses. Thermal transpiration device(Knudsen pump) having no moving parts can self-pump the gaseous propellant by temperature gradient only (cold to hot). We designed, fabricated the Knudsen pump and analyzed pressure gradient efficiency of membrane according to Knudsen number under vacuum condition. Experimental results showed that thick membranes are more effective than thin membranes in transition flow regime, and pressure gradient efficiency according to Knudsen number is increased to maximum 82% apart from membrane thickness in free molecular regime.

Experimental Study of Water Penetration Rate Via Graphene Oxide Membrane According to Driven Pressure Difference (산화 그래핀 맴브레인의 물투과 속도와 차압 조건 간 상관관계에 대한 실험적 연구)

  • Kim, Ji-Min
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.20 no.6
    • /
    • pp.858-864
    • /
    • 2018
  • Graphene oxide (GO) laminate is a new promising material for water purification system, which has extraordinary permeability only for water molecule. It consists of numerous nano-channels, in which water molecules could be nano-confined, resulting in slip of the molecules for very fast transportation speed. In this study, water penetration rate via different thickness of GO membrane according to driven pressures are measured experimentally, so that speed of water molecules and permeability are evaluated. Generally, water penetration rate via a membrane with macroscopic-sized channel increases linearly with pressure difference between up and bottom side of the membrane, but that via GO membrane approaches asymptotic value (i.e. saturation) as like a log function. Moreover, the permeability of GO membrane was observed in inverse proportion to its thickness. Based on the experimental observations, a correlation for volume flux via GO membrane was suggested with respect to its thickness and external pressure difference.

Numerical Analysis on the Stress Behaviours Due to Geometry Effects of the Membrane Corrugation (멤브레인의 주름 형상이 응력거동에 미치는 영향에 관한 수치적 해석)

  • Kim Chung-Kyun;Lee Young-Suck;Cha Baeg-Soon;Kim Young-Gyu;Yoon In Soo;Hong Seong Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.1 no.1
    • /
    • pp.21-26
    • /
    • 1997
  • This paper presents the numerical results of six corrugation models which compute the stress behaviours and stress levels of the membrane structure under the hydrostatic pressure of cryogenic liquids and thermal loadings using a non -linear finite element analysis program. A three-dimensional analysis of various corrugation geometries was performed on the maximum mean normal stress distributions along the upper surface of the membrane sheet. Comparisons of the FEM results for various geometry models of the corrugation are presented, which shows that the corrugated configuration of the ring knot model can be effectively performed for the combined forces such as the hydrostatic pressure and thermal loading in comparison with the Technigaz type corrugation which has small comer and apex curvatures. The FEM results show that the ring knot corrugation can be used for the deepest depth, 180m of the LNG storage tank in comparison with other corrugation models.

  • PDF

Study on Remote Smart Control System for Human Detection on Bed (침상의 인체감지를 위한 원격 스마트 제어 시스템에 관한 연구)

  • Park, Seung-Hwan;Sim, Woo-Jung;Jung, Jin-Taek;Kim, Young-Ser
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.12
    • /
    • pp.63-69
    • /
    • 2017
  • This study is about the development of a smart bed control system to be able to detect the human position and body signal on bed. The main control board in the bed control system consists of the human sensing part, motor driving part and MCU. Here, to increase the credibility to check the human presence on bed, the human sensing part is combined with the human position part by membrane sensor and the body-signal detecting part of EMFI sensor. Also, remotely connecting the two detected signal to the application program of the app mode makes it possible to monitor human information on bed. In this paper, the remote function monitoring of the on-bed human information by bluetooth communication will be abe to make it applicable to the technical prevention method of the bed fall and absence accident in hospital and care facilities.

Determination of bromate in bottled mineral water in Korea (먹는 샘물 중 bromate 분석 및 분포 특성)

  • Ahn, Hye-Sil;Kim, Hyun-Koo;Park, Ju-Hyun;Jung, Dong-Il;Kim, Tae-Seung
    • Analytical Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.155-160
    • /
    • 2010
  • This study was performed to compare international analytical methods of bromate and applied to determine bromate in bottled mineral water in Korea. Bromate in bottled mineral water was eluted by 10~50 mM potassium hydroxide (KOH) and determined by ion chromatograph-suppressed conductivity detector (ICCD). Sample was purified with on guard Ba-, Ag- and H-cartridges and $0.2\;{\mu}m$ membrane filter. The method detection limit (MDL) and the limit of quantitation (LOQ) of bromate were 0.1 and $0.5\;{\mu}g/L$, respectively. The calibration curve showed good lineality above 0.9998 in the ranges of the $0.5\sim40\;{\mu}g/L$. Bromate from 33 samples among total 157 bottled mineral water samples was detected in the concentration range of $0.5\sim6.5\;{\mu}g/L$. The detected concentrations were within bottled mineral water quality criteria ($10\;{\mu}g/L$) in Korea.

Determination of bromide in bottled mineral water and ground water in Korea (먹는 샘물 및 지하수 원수 중 bromide 분석연구)

  • Ahn, Hye-Sil;Seo, Kyoung-Ae;Park, Ju-Hyun;Lee, Jun-Bae;Kim, Tae-Seung;Han, Jin-Seok;Kwon, Oh-Sang
    • Analytical Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.10-14
    • /
    • 2011
  • This study was performed to compare international analytical methods of bromide and applied to determine bromide in bottled mineral water and raw ground water in Korea. Bromide in water was eluted by 10~50 mM potassium hydroxide (KOH) and determined by ion chromatography-suppressed conductivity detector (IC-CD). Sample was purified with Ba- and H-on-guard cartridge and $0.2\;{\mu}m$ membrane filter. The method detection limit (MDL) and the limit of quantitation (LOQ) of bromide were 0.2 and $0.5\;{\mu}g/L$, respectively. The calibration curve showed good lineality above 0.9993 in the ranges of the $0.5\sim80\;{\mu}g/L$. A correlation coefficient of bromide in ground water and sum of bromide and bromate in bottled mineral water is 0.808.