In order to radiate X-ray, the low ripple stabilized high voltage DC over the range of 40KV to 150KV is directly inflicted to X-ray tube. The energy characteristics of the radiated X-ray depend on the pulsating waveforms of the DC voltage supplied X-ray tube. In general, the low ripple voltage waveforms with fast rising times are required to increase with the dosage per unit time lest the exposure time should be longer in orde that the motion artifacts of an object may be eliminated in actual. The conventional types of X-ray generators were bulky in physical size and heavy in weight, and the control accuracies of the output voltages were not always satisfactory. The high frequency switching inverter and converter technology on power conversion and control systems have been greatly closed up introducing new power semiconductor devices. To decreasing the volume and the weight of high voltage transformer, and to stabilize ripple, a high frequency PWM inverter is connected between DC source and high voltage transformer. This paper describes the output characteristics according to stabilize ripple of X-ray tube voltage and compared the reproducibility, direcibility and doesage.
Flow and pressure ripple in swash plate type piston pumps is largely dependent on the design of notches(silencing grooves) in the valve plate. In uni-directional pumps, the basic design concept for notches in the valve plate could be said to be established. It is easily deduced that the design concept for notches in uni-directional pumps can not be simply applied to bi-directional pumps requested for EHA(electric hydrostatic actuators). To carry out systematic research on technological issues regarding notch applications to bi-directional piston pumps, five notch designs are devised. The effects of the notch designs on the characteristics of the pump are investigated by numerical simulations and experiments. Through this study, basic concepts about notch design for bi-directional piston pumps are suggested.
최근 산업기기의 대형화로 인하여 전기기기 및 전력기기의 고효율 대용량 설계에 대한 관심이 커지고 있다. 그 동안에는 대용량 전동기로 주로 유도전동기와 릴럭턴스 전동기가 사용되어 왔다. 그러나 유도전동기는 저속에서의 효율이 낮으며 회전자의 열손실이 효율과 역률을 저하시키는 단점이 있고, 릴럭턴스 전동기는 구조 및 동작원리 상 큰 맥동토크로 인하여 소음과 진동이 매우 크다. 이에 효율과 역률이 좋고 고속운전이 가능한 영구자석형 전동기에 대한 연구가 많이 진행되었고 최근에는 영구자석 재질(희토류계)의 발달함로 인하여 고속 대용량 자석계자형 BLDC와 영구자석형 동기전동기의 설계가 가능해져 대형기에 많이 이용되고 있다. 그러나 대용량 전기기기의 경우 그 크기와 부피가 매우 크고 대전류 대전압의 전원을 공급하여야 하기 때문에 인버터부를 병렬 연결하여야 하므로 제어부를 포함한 전동기의 설치 공간이 증가해 지는 단점이 있다. 이에 본 연구에서는 인버터를 전동기의 회전자 내부에 배치한 인버터 내부형 5[MW]급 BLDC 전동기를 설계하고자 하였다.
A rear axle steering (RAS) system is attached to the rear of medium and large commercial vehicles that transport large cargo. The existing RAS systems are driven by electro-hydraulic actuator (EHA), and most commercialized EHAs consist of electric motors, hydraulic pumps, relief valves, prefill valves and cylinders. The prefill valve required for such EHAs is a type of check valve with extremely low cracking pressure that should not allow RAS to have noise or vibration, and the prefill valve prevents system negative pressure as well as unstable operation. Most papers on this topic rely on experiments to predict valve performance, and theoretically detailed modeling of valves or pipelines is performed, but it is very rare to evaluate hydraulic vibration characteristics by analysing everything from hydraulic pumps to valves comprehensively. In this study, we proposed an experimental circuit that can predict the performance of the prefill valve. The study also analysed the pressure-flow pulsation that is transmitted to the valve through the pipeline, and how the transmitted pressure-flow pulsation affects the valve vibration.
생명구조장치(ECLS)는 호흡부전 및 심부전에 적용하는 장치로 세계적으로 많은 연구개발과 임상시도가 계속되고 있다. 현재까지 생명구조장치의 혈류펌프로는 비박동형 구동장치가 표준으로 사용되고 있으며, 박동형 구동장치는 생리적인 측면에서 유리하지만 급격한 회로압 상승과 그에 따른 혈구손상에 대한 우려가 있고 특히 막형산화기를 사용하는 인공폐 회로에서 기피되어 왔다. 본 연구는 인공폐 실험모델에서 단일 박동형 구동펌프와 막형 산화기 사이에 압력완충장치를 설치함으로써 언급한 부작용을 최소화시키면서 생리적인 박동혈류를 유도할 수 있을 것이라는 가능성을 검증하였다. 실험대상은 올레익산으로 급성 호흡부전증이 유발된 잡견(N=16)을 사용하였다. 실험군은 사용된 구동펌프의 종류와 압력완충장치의 유무에 따라 3개 군으로 분류하였다. 제1군(n=6)은 대조군으로 원심펌프를 이용하였고, 제2군(n=4)은 단일 박동형 구동펌프를 사용하였으며, 제3군(n=6)은 단일 박동형 구동펌프에 압력완충장치를 설치하였다. 실험모델은 흉강 절개 후 우심방-대동맥을 우회시키는 부분 체외순환 형태로, 1.8~2 L/min의 펌프박출량에서 2시간을 구동하였다. 관찰지표는 주로 혈역학 변화, 회로압, 혈액검사 및 혈구세포에 미치는 영향 등에 한정하였다. 맥동압(pulse pressure)은 박동형 구동펌프를 이용한 2군(47$\pm$10 mmHg)과 3군(41$\pm$9 mmHg)에서 비박동형 원심펌프를 이용한 1군(17$\pm$7 mmHg)에 비해 유의하게 높았다(p<0.001). 막형산화기에 걸리는 회로압은 1 군의 경우 222$\pm$8mmHg, 2군의 경우 739 $\pm$ 35 mmHg, 3군의 경우 470$\pm$ 17 mmHg였다(p<0.001). 순환 2시간째의 동맥혈 산소분압은 1군에 비해 박동혈류를 사용하는 2군과 3군에서 현저하게 높았다(77$\pm$41, 96$\pm$48, 97$\pm$25 mmHg; p<0.05). 혈구손상지표인 혈장 유리 헤모글로빈치는 1군에서 가장 낮았고, 2군에서 가장 높았으며, 3군에서 유의하게 감소하였다(55.7$\pm$43.3, 162.8$\pm$113.6, 82.5$\pm$25.1 mg%; p<0.05). 기타 혈액검사치는 특별한 차이가 없었다. 이상의 결과에서 단일 박동형 구동펌프는 비박동형 원심펌프에 비해 막형산화기의 산소교환에 유리한 반면, 회로압과 혈구세포 손상 측면에서 불리하다는 것을 알 수 있었다. 그러나 단일 박동형 구동펌프와 막형 산화기 사이에 압력완충장치를 설치하는 경우, 회로압 상승과 혈구세포손상을 유의하게 감소시킬 수 있었다.
출구유로 단면적이 수직 환상공간 내부의 풀비등 열전달에 미치는 영향을 규명하기 위하여 세 가지 서로 다른 유동제한장치를 실험적으로 연구하였다. 가열 튜브는 매끈한 표면을 가지는 스테인리스강이며 대기압 상태 하에 있는 물을 사용하였다. 환상공간의 하부유로 조건은 개방과 폐쇄된 경우 두 가지를 모두 고려하였으며 유동제한장치를 설치한 환상공간에 대한 결과를 유동제한장치가 없는 환상공간에 대한 결과와 서로 비교하였다. 출구유로 단면적을 축소하는 것은 열전달의 감소를 초래하지만, 출구 유로가 아주 작은 경우 열전달계수가 증가하는 경우도 관찰되었다. 이러한 경향은 기포군집의 형성과 이동에 따른 액체교란의 차이로서 설명되며, 유동대류, 맥동류 발생, 기포 군집 하부의 미세층증발이 중요한 열전달 기구인 것으로 확인하였다.
The purpose of this study was to assess the effects of High-Voltage Pulsed Current (HVPC) and ultrasound on adjuvant-induced arthritis in rats. Adjuvant arthritis was induced in female Sprauge-Dawley rats by the subcutaneous injection of a single dose of $.1m{\ell}$ of Complete Freund's Adjuvant (CFA) (1 mg of Mycobacterium Butyricum suspended in $.1m{\ell}$ paraffin oil) into the right hind paw. A randomized, parallel-groups design of 24 subjects was used. All rats were randomly assigned to control (n=8), ultrasound (n=8), and HVPC (n=8) were compared with those of injured rats. The rats in the pulsed ultrasound group were treated at 1 MHz frequency with $.5W/cm^2$ intensity in 1:4 mode for 5 minutes per day. The rats in the HVPC group were treated at 120 pulses per second and $50{\mu}s$ phase duration, 20 mA intensity for 30 min per day. Treatment was done in the left and right hind limb for 2 weeks. We evaluated clinical, radiographic, hematologic and histopathologic findings before and after treatment and obtained the following results. 1. Edema of the right hind paw was more significantly reduced in the ultrasound and HVPC groups than the control group on days 9, 12, and 14 (p<.05). Edema of the left hind paw was more significantly reduced in ultrasound and HVPC groups than the control group on days 12, 14 (p<.05). 2. WBC counts of the ultrasound and HVPC groups as compared with the control group were becoming remarkably decreased after the treatment. 3. In radiologic findings, arthritis formation was seen according to the score of arthritis, which was the highest in the control group, upon the observation of radiographs of the left and right hind paws. However, no statistically significant difference was present in the score within three groups. 4. In the histopathologic findings, ultrasound and HVPC groups had effectively suppressed erosions of articular cartilage and inflammatory cell infiltrations. Therefore, the results of the study show that rats that were treated with the ultrasound and HVPC effectively suppressed adjuvant arthritis. However, no statistically significant difference was present between the ultrasound group and the HVPC group.
본 연구는 고전압맥동전류자극이 생검 건의 세포 이동 및 증식의 증진 여부를 규명하기 위하여 시행하였다. 닭의 심지굴근건을 적출하고 직경 2mm의 생검하여 배양하였다. 생검 건에 100 pps, 50V로 30분간 음극으로 고전압맥동전류자극한 후 생검 건을 피브린로 피복하고 6일간 배양한 후 세포의 이동거리를 측정하고 7일 후 세포증식능을 측정하였다. 대조군과 고전압맥동전류자극군의 세포 이동 거리 및 흡광도를 t-검정한 결과 고전압맥동전류자극군의 세포 이동 거리가 유의하게 증가하였으며 (t=-2.675, p<0.05), 흡광도도 유의하게 증가하였다 (t=-2.136, p<0.05). 이러한 결과는 고전압맥동 전류자극이 생검 건 섬유모세포의 성장과 증식을 유발시키고 있음을 보여주고 있으며, 이러한 결과는 고전압맥동전류자극이 섬유모세포의 세포반응을 활성화시켰음을 시사하고 있어 고전압맥동전류자극의 건손상 치유 기전의 일부를 제시하였다.
개심술 시 심정지 유도를 위해 혈액 심정지액이 안정적인 심근보호 효과로 인해 널리 사용되어 왔으나, 최근에는 결정성 심정지액인 HTK 용액의 사용이 다시 주목받고 있다. 이에 본 연구에서는 냉혈 심정지액과 HTK 용액의 심근보호 효과에 대해 비교 분석하고자 한다. 대상 및 방법: 판막질환 또는 관상동맥질환을 가진 환자 40명을 대상으로 냉혈 심정지액(CBC group, n=20)과 HTK 용액(HTK group, n=20)을 이용하여 심정지를 유도하였다. 수술 전과 후의 심기능의 차이를 비교하기 위해 술전, 수술 직후, 술 후 1일째의 혈역학적 지표 및 술 후 임상경과를 비교하였다. 또한 심장 초음파를 이용하여 좌심실의 수축기능의 변화를 조사하였다. 허혈에 따른 심근손상 정도를 비교하기 위해 심정지전 그리고 재관류 직후의 관상정맥동과 요골동맥의 CK-MB의 차이(ΔCK-MB), Troponin I의 차이 (ΔTro-I), 젖산의 차이(ΔLac)를 측정하였으며, 그리고 술 후 6, 12, 24, 48시간째 CK-MB의 수치를 연속적으로 측정하였다. 결과: 술 전 환자의 임상적 특징은 두 군간에 차이가 없었으며 인공호흡기 제거 시간, 중환자실 재원기간 등의 술 후 임상경과 역시 두 군 모두 비슷하였다. 술 후 측정한 CBC group 및 HTK group의 ΔCK-MB (15.3$\pm$26.0 vs 19.3$\pm$14.3), ΔTro-I (2.4$\pm$4.9 vs 2.0$\pm$2.20), 리Lac (1.6 $\pm$1.0 vs 1.9$\pm$2.5)으로 심정지에 의한 심근 손상의 정도에 있어서는 두 군간에 유의한 차이가 없었으며, 술 후 연속적으로 측정한 CK-MB 역시 차이가 없었다. 혈역학적 지표로서 측정한 동맥 혈압, 폐 동맥압, 중심정맥압, 폐동맥 쐐기압, 전신혈관저항, 그리고 심박출지수(CI)에서 두 군간에 유의한 차이는 없었으며, 술 후 심초음파에서 측정한 좌심실 박출률은 두 군 모두 술 전과 차이를 보이지 않았다. 결론: 이상의 결과에서 HTK 용액의 심근 보호효과는 기존의 냉혈 심정지액과 유의한 차이가 없음을 확인할 수 있었다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.