• Title/Summary/Keyword: 망막신경섬유층

Search Result 4, Processing Time 0.018 seconds

Study of Correlation between Macular Thickness, Retina Nerve Fiber Layer Thickness and Axial Length according to Refractive Errors in Children (아동들의 굴절이상에 따른 안축장과 황반두께, 망막신경섬유층 두께의 상관성연구)

  • Choi, Hyung-Seok;Leem, Hyun-Sung
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.421-429
    • /
    • 2018
  • Purpose : We identified correlation between macular thickness and RNFL (retina nerve fiber layer) measured by OCT and axial length in Korean children divided as three groups according to refractive errors. Methods : In total, 134 eyes of 67 Korean children who experienced no eye disease and ophthalmology surgery were involved in this study and then divided as three groups such as hyperopic, emmetropic and myopic groups. Macular thickness and RNFL thickness were measured with Cirrus HD-OCT, and axial length was done with IOL Master.Macular thickness and RNFL thickness were measured by Cirrus HD-OCT, and axial length using IOL Master. Correlation between axial length and retinal thickness in three groups according to refractive errors was investigated. Results : The type of refractive error measured by axial length was myopic, emmetropic and hyperopic groups in order, showing significant difference (p<0.05). The center thickness of macular was myopic, emmetropic and hyperopic groups in order, showing significant difference(p<0.05). The thicknesses of superior, nasal and inferior regions in peripheral macula were the thinnest in myopic group (p<0.05). It was shown that positive correlation was found between the center thickness of macula and axial length (r=0.283, p<0.05), while negative correlation was found between the peripheral thickness of RNFL and axial length. The temporal thickness of RNFL represented the thickest in myopic group, showing positive correlation with axial length(r=0.39, p<0.05). The superior, nasal and inferior thickness of RNFL represented negative correlation with axial length, showing statistically significant in the nasal thickness of RNFL(r=-0.23, p<0.05). Conclusion : Through this study, we identified correlation between macular thickness, the thickness of RNFL and axial length using OCT in Korean children, and also found the differences in three refractive error groups.

Two Cases of Long-Term Changes in the Retinal Nerve Fiber Layer Thickness after Intravitreal Bevacizumab for Diabetic Papillopathy (당뇨병유두병증에서 유리체강내 베바시주맙 주입술 후 망막시경섬유층 두께의 장기간 변화 2예)

  • Kim, Jong Jin;Im, Jong Chan;Shin, Jae Pil;Kim, In Taek;Park, Dong Ho
    • Journal of The Korean Ophthalmological Society
    • /
    • v.54 no.9
    • /
    • pp.1445-1451
    • /
    • 2013
  • Purpose: To report long-term changes in the average retinal nerve fiber layer (RNFL) thickness in 2 patients who had intravitreal bevacizumab (IVB) injection for diabetic papillopathy. Case summary: A 36-year-old patient with diabetes complained of decreased visual acuity (20/200) in the right eye. The fundus examination showed optic disc swelling in both eyes. The average RNFL thickness based on optical coherence tomography (OCT) increased to $278{\mu}m$ and Goldmann perimetry showed nasal visual field defect in the right eye. The IVB was injected into the right eye. Three weeks after the IVB injection, RNFL thickness decreased to $135{\mu}m$ and visual acuity improved to 20/25 in the right eye. However, RNFL thickness increased from 126 to $207{\mu}m$ and visual acuity decreased to 20/32 in the left eye. Thus, IVB was injected into the left eye. In week 3, RNFL thickness decreased to $147{\mu}m$ and visual acuity improved to 20/20 in the left eye. At 12 months after IVB injection, RNFL thickness was $87{\mu}m$ in the right eye and $109{\mu}m$ in the left eye. A 57-year-old patient with diabetes complained of decreased visual acuity (20/200) and showed optic disc swelling in the right eye. The average RNFL thickness increased to $252{\mu}m$ and Goldmann perimetry showed an enlarged blind spot in the right eye. IVB was injected into the right eye. After 3 weeks, RNFL thickness decreased to $136{\mu}m$ and visual acuity improved to 20/70 in the right eye. Six months after IVB injection, RNFL thickness was $83{\mu}m$ in the right eye. Conclusions: Visual acuity progressively improved within 3 weeks and RNFL thickness measured by spectral domain OCT showed progressive thickness reduction in 2 cases of diabetic papillopathy patients who had IVB injections.

Toxic Optic Neuropathy Caused by Chlorfenapyr Poisoning (클로르페나피르 음독 후 발생한 독성 시신경병증 1예)

  • Park, Su Jin;Jung, Jae Uk;Kang, Yong Koo;Chun, Bo Young;Son, Byeong Jae
    • Journal of The Korean Ophthalmological Society
    • /
    • v.59 no.11
    • /
    • pp.1097-1102
    • /
    • 2018
  • Purpose: To report a case of toxic optic neuropathy caused by chlorfenapyr ingestion accompanied by central nervous system involvement. Case summary: A 44-year-old female visited our clinic complaining of reduced visual acuity in both eyes for 7 days. She had ingested a mouthful of chlorfenapyr for a suicide attempt 2 weeks prior to the visit. Gastric lavage was performed immediately after ingestion at the other hospital. Her best-corrected visual acuity was finger count 30 cm in the right eye and hand motion in the left eye. Both pupils were dilated by 5.0 mm and the response to light was sluggish in both eyes. A relative afferent pupillary defect was detected in her left eye. Funduscopy revealed optic disc swelling in both eyes. Magnetic resonance imaging of the brain showed a symmetric hyper-intense signal in the white matter tract including the internal capsule, corpus callosum, middle cerebellar peduncle, and brainstem. The patient was diagnosed with toxic optic neuropathy induced by chlorfenapyr ingestion, and underwent high-dose intravenous corticosteroid pulse therapy. Three days later, the best-corrected visual acuity was no light perception in both eyes. Three months later, optic atrophy was observed in both eyes. Optical coherence tomography revealed a reduction in the thicknesses of the retinal nerve fiber layer and ganglion cell and inner plexiform layer in the macular area. Conclusions: Ingestion of even a small amount of chlorfenapyr can cause severe optic nerve damage through the latent period, despite prompt lavage and high-dose steroid treatment.

Choroidal Thickness in Thyroid-associated Ophthalmopathy between Normal Tension Glaucoma Using Optical Coherence Tomography (스펙트럼영역 빛간섭단층촬영으로 측정한 갑상선 안병증 환자와 녹내장환자의 맥락막 두께 분석)

  • Lee, Bo Young;La, Tae Yoon;Choi, Jin A
    • Journal of The Korean Ophthalmological Society
    • /
    • v.58 no.8
    • /
    • pp.960-967
    • /
    • 2017
  • Purpose: To compare the macular choroidal thickness in patients with thyroid-associated ophthalmopathy (TAO) with those with normal tension glaucoma (NTG). Methods: A total of 70 normal eyes, 74 eyes with TAO and 60 eyes with NTG were enrolled in this study. All patients underwent spectral-domain optical coherence tomography (SD-OCT) (Cirrus HD-OCT, Carl Zeiss Meditec Inc., Dublin, CA, USA). Macular choroidal thickness was assessed using enhanced depth imaging. The average macular choroidal thickness was defined as the average value of three measurements: at the fovea and at the points located 1.5 mm in the nasal and temporal directions from the fovea. Generalized estimating equations were used to uncover factors affecting the average macular choroidal thickness. Results: The average, superior and inferior quadrant retinal nerve fiber layer thicknesses were significantly thinner in the NTG group compared with the TAO and control groups (p < 0.001). The average macular choroidal thickness of the TAO group, NTG group and controls was $281.01{\pm}60.06{\mu}m$, $241.66{\pm}55.00{\mu}m$ and $252.07{\pm}55.05{\mu}m$, respectively, which were significantly different (p = 0.013). The subfoveal, nasal and temporal side choroidal thicknesses were significantly thinner in the NTG group compared with the TAO group (p = 0.014, 0.012 and 0.034, respectively). Subjects with TAO were associated with a thicker average macular choroidal thickness compared with the NTG group after adjusting for age, sex, spherical equivalent and intraocular pressure (${\beta}=32.61$, p = 0.017). Conclusions: Macular choroidal thickness was significantly thicker in patients with TAO compared with those with NTG. Further evaluation is required to determine if a thick choroid in subjects with TAO has any role in glaucomatous optic neuropathy.