• Title/Summary/Keyword: 마그네슘 산화막

Search Result 27, Processing Time 0.025 seconds

Performance assessment of Magnesium Bipolar Plates for Light Weight PEM Fuel Cell (PEM 연료전지 경량화를 위한 마그네슘 분리판의 성능평가)

  • Park, To-Soon;Lee, Dong-Woo;Kim, Kyung-Hwan;Kwon, Se-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.12
    • /
    • pp.1063-1069
    • /
    • 2012
  • In present paper, we used magnesium alloy having a lower density and higher electrical conductivity for bipolar plate to reduce the weight of PEM fuel cell. The silver was coated to prevent corrosion and form passivation film on the metal surface with sputtering. In acid proof evaluation for setting optimal coating conditions, the homogeneity of coating thickness was improved by coating with the thickness of 3 ${\mu}m$ which not indicated any micro cracks and the temperature $180^{\circ}C$. The performance test and evaluation based on the clamping pressure and channel depth to determine the configuration of bipolar plate for assembling single cell was implemented. And then we assembled single cell with this bipolar plate and implemented the performance test to ensure and compare the current-voltage performance followed as several factors such as coating or non-coating, the change of clamping pressure, the change of channel depth, etc. As these results, the maximum power density of single cell with the coated bipolar plate was 192 $mW/cm^2$ and it was confirmed that the power density per unit mass was better than existing metal bipolar plate.

Morphology and Crystal Orientation of Mg Films formed on Hot Dip Galvanized Steel by PVD Method at Ar or N2 Gas Pressures and Their Corrosion Resistances (Ar 및 N2 가스압 중에서 PVD법에 의해 용융아연 도금 강재상 형성한 Mg 막의 모폴로지 및 결정배향성과 그 내식성)

  • Hwang, Seong-Hwa;Park, Jae-Hyeok;Park, Jun-Mu;Choe, In-Hye;Kim, Sun-Ho;Lee, Myeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.166-166
    • /
    • 2017
  • 금속 재료 중 철강은 기계적 특성이 우수하고 대량생산이 가능하여 선박, 건축, 자동차 등 다양한 분야에 기초재료로써 널리 사용되고 있다. 그러나 스테인리스강 등과 같은 일부 특수한 용도의 강을 제외하고는 부식환경에 취약한 특성을 가지기 때문에 내식성을 향상을 위한 표면처리에 관한 연구가 활발히 진행되고 있다. 가장 일반적으로 습식법(wet process)을 통해 표면상에 아연(Zn)을 도금해 사용하며, 아연이 자체적으로 포함한 희생양극(sacrificial anode) 및 차폐(barrier) 효과가 철강의 부식을 방지하게 된다. 하지만 산업의 고도화에 따라 더욱 가혹해진 노출환경으로 인해 고내식 강재에 대한 수요가 점차 증가하고 있으며, 아연코팅 층의 두께를 증가하여 내식성을 확보하는 방안은 미래 환경 및 자원적인 측면에서 근본적인 해결책으로 제시하기 어려움이 있다. 한편, 건식 프로세스(wet process)로 대별되는 PVD(physical vacuum deposition)에 의해 내식성을 향상시키고자 하는 연구들이 다양하게 진행되고 있다. 이것은 표면에 고순도 양질의 금속 막을 형성시킴으로써 외부환경과의 반응을 효과적으로 제어가 가능하며, 형성된 막은 그 물질의 고유 특성뿐만 아니라 제작 조건에 따른 표면의 기하학적 혹은 결정학적 구조에 의해 크게 영향을 받게 된다. 본 연구에서는 실용금속 중 이온화 경향이 가장 크고 산소와 반응하여 투과성이 작은 산화 피막 형성이 유리한 마그네슘(Mg)을 활용해 표면의 전기화학적 특성을 향상시켰다. 또한 금속 증착 중 진공도조절을 위해 도입되는 불활성 가스로 아르곤(Ar) 및 질소($N_2$)를 사용하여 표면에 형성한 막의 모폴로지 및 결정배향성이 내식성에 미치는 상관관계를 해석하고자 하였다. 실험방법으로 PVD법 중 비교적 간편하고 기초적인 지침을 제시하기 적합할 것으로 고려된 진공증착(vacuum evaporation)법을 이용해 아르곤 및 질소 분위기에서 진공도를 조절하며 용융아연도금상 Mg막을 형성하였다. 제작조건별 막의 기초 특성을 분석하기위해 SEM, EDS, XRD를 이용하였고, 결정배향성(crystal orientation) 분석을 위해 면간격(d-value)과 상대강도(relative intensity)를 확인하였다. 또한 내식성 평가로 염수분무(salt sprat test) 및 양극분극(anode polarization)을 각각 실시하였다. 실험결과에 따르면, Ar 및 $N_2$ 모두에서 가스압이 증가할수록 코팅층의 증착량은 적어지고 입상정(granular structure)의 모폴로지 형성 및 면간격과 상대강도가 증가하는 것이 확인되었다. 또한 쳄버 내 동일 진공도에서, $N_2$ 도입 시 Mg막은 더욱 치밀하고 미세한 입상정의 모폴로지로 형성되며 면간격과 상대강도는 더욱 증가한 것으로 나타났다. 내식성 평가에서 저진공 $N_2$ 조건에서 형성시킨 막이 가장 우수한 내식성이 나타났는데, 이는 상대적으로 불안정하고 반응하기 유리한 입계면적을 많이 포함한 입상정 모폴로지 및 표면에너지가 높은면의 면점유율 증가로 인해 외부환경과의 신속한 반응은 물론 안정적인 피막형성이 용이하였기 때문일 것으로 사료된다. 이상으로 Ar 및 $N_2$ 가스압 조건에 따른 고내식 Mg 막의 유효성을 확인하였고 향후 내식성을 향상시키는 방법으로 응용 가능할 것으로 생각된다.

  • PDF

Discharge Properties of $Al_2O_3$/MgO as a Dielectric Protection Layer ($Al_2O_3$/MgO 유전체 보호막의 방전특성)

  • Jeoung, Jin-Man;Shin, Kyung;Lee, Young-Jong;Chung, Hong-Bay
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.307-310
    • /
    • 1998
  • In this paper, $Al_2$O$_3$/MgO belayer was prepared with Electron-beam evaporation and the properties of the film was investigated in order to improve the property of MgO film, which is used for the protection layer in PDP(Plasma Display Panel). $Al_2$O$_3$/MgO belayer were improved of roughness and it were condensed by annealing, and the result of XPS analysis for $Al_2$O$_3$/MgO belayer unchanged binding energy. To investigate electric characteristics, discharge properties of $Al_2$O$_3$/MgO belayer were compared with discharge minimum voltage for MgO monolayer through Ar discharge experiments.

  • PDF

A study for development of a dielectric protection layer in PDP (I) (The annealing characteristics of thickness-optimized $Al_2O_3/MgO$) (PDP용 유전체 보호막 재료 개발을 위한 연구 (I) (두께 최적화된 $Al_2O_3/MgO$의 열처리 특성 ))

  • Jeoung, Jin-Man;Yim, Ki-Ju;Shin, Kyung;Lee, Hyun-Yong;Chung, Hong-Bay
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.117-120
    • /
    • 1998
  • In this study, $Al_2O_3/MgO$ bilayer was prepared with Electron-beam evaporation and the properties of the film was investigated in order to improve the property of MgO film, which is used for the protection layer in PDP(P1asma Display Panel). The thickness of $Al_2O_3/MgO$ bilayer was optimized by the Matrix Theory for the fabrication of antireflection structure for 5350A wavelength. The secondary electron emission yields of as-deposited film and annealed film were measured and compared, the bilayer was considered for the applicability as PDP. XRD showed the strong (200) primary peak of MgO. The intensity of (200) peak in the film annealed at 300C was decreased. As the result of SEM analysis for MgO films and Alz03 films, it is considered that the morphology of the films were improved of roughness and it were condensed by annealing.

  • PDF

Changes of Hematological Constituents in the Mullet, Mugil cephalus Exposed to Chromium (크롬 노출에 따른 숭어, Mugil cephalus의 혈액성분 변화)

  • Ahn, Tae-Young;Jeong, Dal Sang;Kim, Jun-Hwan;Kang, Ju-Chan
    • Journal of fish pathology
    • /
    • v.26 no.2
    • /
    • pp.89-97
    • /
    • 2013
  • The study was carried out to investigate the changes of hematological parameters induced by waterborne exposure of chromium (Cr) in the mullet, Mugil cephalus. The mullet was exposed to sub-chronic concentrations of chromium (0, 25, 50, 100, $200{\mu}g/L$ Cr) for 4 weeks. The major hematological findings were significant decreases in the red blood cell (RBC) count and hematocrit value in mullet exposed to ${\geq}50{\mu}g/L$ Cr. Although serum calcium concentration was significantly reduced at ${\geq}50{\mu}g/L$ Cr, magnesium concentration was found to be significantly increased at ${\geq}100{\mu}g/L$ Cr. The serum glucose and total protein concentrations were significantly increased at $200{\mu}g/L$ Cr. However, serum triglyceride concentration did not show any noticeable changes in the range of $25{\sim}200{\mu}g/L$ Cr of chromium compared to control group during the experimental period. A significant increment of GOT (glutamic oxalate transminase) and GPT (glutamic pyruvate transminase) activities was noticed at ${\geq}100{\mu}g/L$ Cr. These results indicate that hematological and serum biochemical changes in the mullet by waterborne exposure to chromium are affected at more than $50{\mu}g/L$ Cr.

X-ray properties measurement of Flat panel Digital X-ray gas detector (평판형 디지털 엑스레이 가스 검출기의 엑스선 특성 측정기술에 관한 연구)

  • Yoon, Min-Seok;Cho, Sung-Ho;Oh, Kyung-Min;Jung, Suk-Hee;Nam, Sang-Hee;Park, Ji-Goon
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.1
    • /
    • pp.17-21
    • /
    • 2009
  • The Recently, large area matrix-addressed image detectors are investigated for X-ray imaging with medical diagnostic and other applications. In this paper, a new flat panel gas detector for diagnostic X-ray imaging is proposed, and its characteristics are investigated. The research of flat panel gas detector is not exist at all. Because of difficulty to inject gas against to atmospheric pressure. So almost gas detector made by chamber shape. We made flat panel sample by display technique. (ex: PDP, Fed, etc.) The experimental measurements, the transparent electrodes, dielectric layer, and the MgO protection layer were formed in front glass. And, the X-ray phosphor layer and address electrodes are formed in the rare glass. The dark current, the x-ray sensitivity and linearity as a function of electric field were measured to investigate the electrical properties. From the results, the stabilized dark current density and the significant x-ray sensitivity were obtained. And the good linearity as a function of exposure dose was showed in wide diagnostic energy range. These results means that the passive matrix-addressed flat panel gas detector can be used for digital x-ray imaging.

  • PDF

Development of Immediate Face Lifting Technology for Reducing Wrinkles by Using Film-Forming Agent (피막 형성제를 이용한 즉각 리프팅 기술 개발)

  • Jun, Ji hyun;Ko, Eun ah;Han, Sang Gun;Kang, Hakhee
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.44 no.3
    • /
    • pp.211-218
    • /
    • 2018
  • Instant face lifting cosmetics contain various film forming agents for stretching the wrinkles on the skin surface. But, most of the film-forming polymers have sticky feels. And they are easily scrubbed out when skin is rubbed on. In this study, we focused on the influence of sodium silicate that has rapid film forming effect on skin surface and immediate wrinkle reducing effect. Sodium silicate, also known as water glass or soluble glass, is a compound containing sodium oxide and silica. Sodium silicate is a white powder that is readily soluble in water, producing an alkaline solution. Sodium silicate is stable in neutral and alkaline solutions. The sodium silicate solution hardens by drying in air and rapidly forms a thin film. When the solution is applied to the skin, the fine membrane coating is formed by water evaporation and ionic bond re-formation. It also makes the strong siloxane (Si-O) bonding on the skin surface. When these fixation properties are applied to cosmetics, they can give remarkable skin tightening effect. The sodium silicate solution can provide the lifting effect by forming a film on skin at a proper concentration. But, skin irritation may be caused with too high concentration of sodium silicate. We studied a desirable range of the sodium silicate concentration and combination with other fixatives for skin care formulation that has no sticky feels and no scrubbing out phenomenon. Immediate lifting gel was developed by using sodium silicate and various thickening systems. Among of the various thickeners, aluminum magnesium silicate showed the best compatibility with sodium silicate for rapid lifting effect. This instant physical lifting gel was confirmed as a low stimulating formula by skin clinical test.