• 제목/요약/키워드: 루프 히트파이프

검색결과 35건 처리시간 0.027초

R141b를 이용한 루프 세관형 히트파이프의 열전달특성 (Heat Transfer Characteristics of Loop Type Capillary Heat Pipe using R141b as a Working Fluid)

  • 김훈;하승만;김탁용;전경환;최재혁;윤석훈
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 후기학술대회논문집
    • /
    • pp.256-257
    • /
    • 2005
  • This paper has been carried out to investigate heat transfer characteristics of loop type capillary heat pipe using R141b as a working fluid. In an experiment heat load are changed from 50W to 250W and the temperature of cooling water is fixed to 20$^{circ}C$ . The heat pipe is composed of 10 turns and outer diameter of heat pipe is 3.2mm. The results show that heat transport rate of this type heat pipe using R141b as a working fluid is good.

  • PDF

루프형 히트파이프를 이용한 LED 헤드램프 열적 특성 (LED Headlamp Thermal Characteristics by Looped Heat Pipe)

  • 노형철;박경석;강병도;손성만
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.443-444
    • /
    • 2006
  • The influence of the heat sources on LED junction temperature are Engine room air, Back plate, Electric power device, and so on. LED lamp cooling system is considered to be an important subject fur high light efficiency. Because LED Chip will be problem When LED junction temperature be over $135^{\circ}C$, In this Study, The Looped Heat Pipe System is considered to prevent LED Chip fall. The LHPS is consist of evaporator part, condenser part, heat pipe part. The working fluid of LHPS is HCFC-123. In this study, to prevent LED Chipfall, we study thermal characteristics for Looped Heat Pipe System with LED lamp.

  • PDF

다공성소결윅구조에 따른 루프 히트파이프에서 압력손실의 이론적 분석 (Theoretical Analysis of the Pressure Drop in Loop Heat Pipe by Sintered Porous Wick Structure)

  • 이기우;이욱현;박기호;이계중;전원표;인현만
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1225-1230
    • /
    • 2004
  • In this paper, the pressure drops were investigated according to the sintered porous wick structure in loop heat pipe(LHP) by theoretical analysis. LHP has the wick only in evaporator for the circulation of working fluid, so utilizes porous wick structure which pore diameter is very small for large capillary force. This paper investigates the effects of different parameters on the pressure drops of the LHP such as particle diameter of sintered porous wick, wick porosity, vapor line diameter, thickness of wick and heating capacity. Working fluid is water and the material of sintered porous wick is copper. According to the these different parameters, capillary pressure, pressure drop in wick were analized by theoretical design method of LHP.

  • PDF

가역 루프 히트파이프의 작동특성에 관한 실험적 연구 (An Experimental Investigation on the Operating Characteristics of a Reversible Loop Heat Pipe)

  • 김봉훈;최준민
    • 설비공학논문집
    • /
    • 제18권3호
    • /
    • pp.231-239
    • /
    • 2006
  • An experimental investigation of a Reversible Loop Heat Pipe (RLHP) was conducted to determine the operating limits and performance characteristics as functions of the thermophysical parameters, the heat input, and the cooling intensity. Variations in both temperature and heat transport capacity were measured and analyzed in order to accurately evaluate the transient operating characteristics. In addition, the maximum heat transport as a function of the mean evaporator temperature, the ratio of heat transport to heater input power as a function of the mean evaporator temperature, and the overall thermal resistance as a function of the overall heat transport capacity were examined as well. Results indicated that the cooling intensity played an important role on the operating characteristics and performance limitation. The maximum heat transports corresponding to cooling intensity $72W/^{\circ}C$ and $290W/^{\circ}C$ were 446 W and 924 W, respectively. Also, observation of the startup characteristics indicated that the mean evaporator temperature should be maintained between $40^{\circ}C$ and $60^{\circ}C$, and overall thermal resistance were measured as $0.02^{\circ}C/W$.

루프형 히트파이프 냉각성능에 관한 연구 (Cooling Performance Evaluation of Loop Type Heat Pipe)

  • 김봉환;김경훈
    • 한국분무공학회지
    • /
    • 제7권2호
    • /
    • pp.31-36
    • /
    • 2002
  • According to the improvement of PC performance, it is expected that calorific value, which causes PC to malfunction, is increased. Therefore, the development of new cooling system is recently required. As the method to solve this problem, we applied loop heat pipe to PC cooling system. The advantage of the loop heat pipe is that it has a small size, light weight, simple shape, long life and it has a good performance on heat transfer, no-noise, wide range of applicable temperature and no supply of power from the outside. It is confirmed that loop heat pipe reduces thermal resistance and has a good performance on PC cooling.

  • PDF

평판형 증발부를 갖는 루프히트파이프에 대해 박막이론을 적용한 해석적 모델링 (Analytical Modeling of a Loop Heat Pipe with a Flat Evaporator by Applying Thin-Film Theory)

  • 정의국;부준홍
    • 대한기계학회논문집B
    • /
    • 제34권12호
    • /
    • pp.1079-1085
    • /
    • 2010
  • 평판형 증발부를 갖는 루프히트파이프(LHP)에 대한 정상상태 해석모델을 제시하였다. 관련문헌의 고찰에 기초하여 LHP 의 주요 부분인 증발부, 액체저장조(보상챔버), 증기이송관, 액체이송관 및 응축부에서 온도와 압력을 예측할 수 있도록 계산과정을 제시하였으며, LHP 에서 유일하게 모세관 구조물을 가지는 증발부의 해석에 중점을 두었다. 증발부에서 액체 -기체 경계면 부근에서 압력과 온도의 영향을 고려하기 위해 박막이론을 사용하였으며, 수정된 기체분자운동이론에서 응축경계면 온도를 산정하는데 있어서 독특한 방법을 도입하였다. 응축부에서는 상변화 경계면을 단순화하여 처리함으로써 응축부 형상 변화에 상대적인 융통성을 구비하도록 하였다. 본 연구의 LHP 정상상태 해석 모델은 문헌 상의 실험결과에 의해 타당성이 증명되었다. 해석모델에 의한 예측치는 실험치와 비교할 때 절대온도를 기준으로 최대 상대오차 3% 이내로서 합리적으로 잘 일치하였다.

마이크로 세라믹 윅을 사용한 루프 히트파이프의 특성 연구 (Characteristic Studies on Loop Heat Pipe with Micro Ceramic Wick)

  • 박종찬;이충구;이석호
    • 대한기계학회논문집B
    • /
    • 제31권10호
    • /
    • pp.823-831
    • /
    • 2007
  • This paper presents the experimental and simulation study of a loop heat pipe (LHP) that can be applied to present electronics, space missions and thermal control systems. The present experimental study was carried out employing sintered alumina ceramic wick ($d=2.96\;{\mu}m$, ${\phi}=0.61$). High purity R-134a, R-22 and water were also used as alternative working fluids in addition to ammonia. The experimental study showed that the maximum heat transfer performance for the test LHP in the vertical top heating mode was over 100 Watts when ammonia was used as the working fluid. The simulation results have been compared with the experimental results to validate a simulation model based on the thermal resistance network that was developed to evaluate the performance of LHPs, focusing on their prospective applications in electronics. The simulation model is based on the loop overall energy, mass, and momentum balance. The simulation program can predict the effects of various parameters which affect the performance of LHP within 5% compared with the experimental results.