• Title/Summary/Keyword: 디지털 심전도기

Search Result 10, Processing Time 0.022 seconds

Clinical Usefulness of Digital ECG Recorder in Dogs : 4 Cases (디지털 심전도기의 임상적 적용 예 : 4 증례)

  • Moon, Hyeong-Sun;Lee, Seung-Gon;Hyun, Chang-Baig
    • Journal of Veterinary Clinics
    • /
    • v.24 no.2
    • /
    • pp.218-224
    • /
    • 2007
  • Digital electrocardiogram (ECG) recorders are rapidly replacing to conventional paper ECG recorders. Digital ECG recorders have several advantages over conventional type ECG recorders, including better capability for data storage, better portability and better applicability in clinical settings. In this study, we presented 4 case studies related to cardiac rhythm disturbances, which were diagnosed and managed using a digital ECG recorder.

Low-Power ECG Detector and ADC for Implantable Cardiac Pacemakers (이식형 심장 박동 조율기를 위한 저전력 심전도 검출기와 아날로그-디지털 변환기)

  • Min, Young-Jae;Kim, Tae-Geun;Kim, Soo-Won
    • Journal of IKEEE
    • /
    • v.13 no.1
    • /
    • pp.77-86
    • /
    • 2009
  • A wavelet Electrocardiogram(ECG) detector and its analog-to-digital converter(ADC) for low-power implantable cardiac pacemakers are presented in this paper. The proposed wavelet-based ECG detector consists of a wavelet decomposer with wavelet filter banks, a QRS complex detector of hypothesis testing with wavelet-demodulated ECG signals, and a noise detector with zero-crossing points. To achieve high-detection performance with low-power consumption, the multi-scaled product algorithm and soft-threshold algorithm are efficiently exploited. To further reduce the power dissipation, a low-power ADC, which is based on a Successive Approximation Register(SAR) architecture with an on/off-time controlled comparator and passive sample and hold, is also presented. Our algorithmic and architectural level approaches are implemented and fabricated in standard $0.35{\mu}m$ CMOS technology. The testchip shows a good detection accuracy of 99.32% and very low-power consumption of $19.02{\mu}W$ with 3-V supply voltage.

  • PDF

A New Method for Engagement Analysis in Online Game using ECG (심전도를 이용한 온라인 게임 몰입 상태 분석 방법)

  • Kim, Young-Jin;Kang, Hang-Bong
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2014.04a
    • /
    • pp.975-977
    • /
    • 2014
  • 논문은 심전도를 이용하여 디지털 환경에서의 이용자의 몰입 상태를 측정하기 위한 시스템에 대한 것이다. 기본적으로 피험자에게 설문을 통하여 얻어낸 시간 단위의 몰입 여부에 대해서 측정된 심전도와의 상관 관계를 랜덤 포레스트를 이용하여 학습된 분류기를 이용하여 분석한다.

The implementation of modular respiratory system for patient monitoring (환자감시를 위한 모듈형 호흡 시스템의 구현)

  • 박종억;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.503-506
    • /
    • 2001
  • There are four factors for patient monitoring : electrocardiography, blood pressure, temperature and respiration. While there are a lot of studies of E.C.C (electro-cardiography) monitoring system in the world, the studies of Respiratory system are not enough and leave much to be desired in the country. In this paper, we developed a respiratory system with the electrical impedance change of the lungs depending on the breath. Using the same electrode, we can monitor E.C.C and Respiration simultaneously, so we can monitor a patient's no-breathing state due to the central nerve paralysis in the emergency room easily. In this monitoring system, the analog part was made separated from the digital part for reducing power source noise and protecting patient from electric shock. The analog part consists of the several parts a high-frequency sine-wave generator, all amplifier for amplifying any impedance change signal, an analog processing part for rectifying and filtering. And the digital parts consists of three parts an AD convertor for converting analog signal to digital signal, digital filter, and a digital part for digital signal processing. This system's merits are using the same electrode with E.C.C and developing the multiple patient monitoring system easily.

  • PDF

A Study on the Implementation of Real-time Digital Filter System for the Baseline Wandering Elimination (기저선 변동 제거를 위한 실시간 디지털 필터 시스템 구현에 관한 연구)

  • 윤승구;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.512-515
    • /
    • 2001
  • The heifer electrocardiograph is a widely progressing research which is used in judgement to existence for a heart disease and analyzes electric potential changes of heart movement during continuous living of everyday after attaching to body portable holler recorder for twenty-four hours. In order to obtain electrocardiogram clearly, it must eliminate that 60Hz power line interference, baseline wandering, noise of muscle constriction. In holter electrocardiogram, the most big problem which is recorded signal of ECG(electrocardiogram) is a baseline wandering elimination, which is occurred by rhythm of respiration and muscle constriction of part from attaching to an electrode. Such baseline is roughly irregular wandering and shaking up and down therefore the part of baseline wandering elimination is very important because it is difficult of ECG diagnosis. In this study, it is stabilized baseline wandering in analog part as implementation f real-time signal processing digital filter so it is applicable to analyze patient's heart disease by way of design of baseline wandering elimination system.

  • PDF

High Frequency Noise Reduction in ECG using a Time-Varying Variable Cutoff Frequency Lowpass Filter (시변 가변차단주파수 저역통과필터를 이용한 심전도 고주파 잡음의 제거)

  • 최안식;우응제;박승훈;윤영로
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.2
    • /
    • pp.137-144
    • /
    • 2004
  • ECG signals are often contaminated with high-frequency noise such as muscle artifact, power line interference, and others. In the ECG signal processing, especially during a pre-processing stage, numerous noise removal techniques have been used to reduce these high-frequency noise without much distorting the original signal. This paper proposes a new type of digital filter with a continuously variable cutoff frequency to improve the signal quality This filter consists of a cutoff frequency controller (CFC) and variable cutoff frequency lowpass filter (VCF-LPF). From the noisy input ECG signal, CFC produces a cutoff frequency control signal using the signal slew rate. We implemented VCF-LPF based on two new filter design methods called convex combination filter (CCF) and weight interpolation fille. (WIF). These two methods allow us to change the cutoff frequency of a lowpass filter In an arbitrary fine step. VCF-LPF shows an excellent noise reduction capability for the entire time segment of ECG excluding the rising and falling edge of a very sharp QRS complex. We found VCF-LPF very useful and practical for better signal visualization and probably for better ECG interpretation. We expect this new digital filter will find its applications especially in a home health management system where the measured ECG signals are easily contaminated with high-frequency noises .

A Study on the Sensor Module System for Real-Time Risk Environment Management (실시간 위험환경 관리를 위한 센서 모듈시스템 연구)

  • Cho, Young Chang;Kwon, Ki Jin;Jeong, Jong Hyeong;Kim, Min Soo
    • Journal of IKEEE
    • /
    • v.22 no.4
    • /
    • pp.953-958
    • /
    • 2018
  • In this study, a portable detection system was developed that can detect harmful gas and signals simultaneously in an enclosed space of industrial sites and underground facilities. The developed system is a sensor module for gas detection, a patch type 1 channel small ECG sensor, a module for three-axial acceleration detection sensor, and a system for statistics. In order to verify the performance of the system modules, the digital resolution, signal frequency, output voltage, and ultra-small modules were evaluated. As a result of the performance of the developed system, the digital resolution was 300 (rps) and the signal amplification gain was 500 dB or more, and the ECG module was manufactured with $50mm{\times}10mm{\times}10mm$ to increase patch utilization. It is believed that the product of this research will be valuable if it is used as an IoT-based management system for real-time monitoring of industrial workers.

A Fetal ECG Signal Monitoring System Using Digital Signal Processor (디지털 신호처리기를 사용한 태아심전도 신호 추출 시스템)

  • 박영철;조병모;김남현;김원기;박상휘;연대희
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.9
    • /
    • pp.1444-1452
    • /
    • 1989
  • This paper describes the implementation of a real time fetal ECG monitoring system in which an adaptive multi-channel noise canceller is realized using the Texas Instruments TMS32020 progrmmmable ditital signal processor. An ECG signal from the electrode placed on the mother's abdomen and three ECGs from those on the chest are applied as the desired signal and the referened inputs, respectively, of the multi-channel filter. The coefficients of the filter are updated using the LMS algorithm such that the output of the multi-channel filter copies the maternal ECG embedded in the abdominal ECG. The enhanced fetal ECG is obtained by subtracting the filter output from the abdominal ECG, and the difference signal is recorded. Both off-line and on-line experimental results are presented to verify the effectiveness of the parameters for the digital signal processing algorithms and the prototype system.

  • PDF

Design and implementation of comb filter for multi-channel, 24bit delta-sigma ADC (다채널 24비트 델타시그마 ADC 용 콤필터 설계 및 구현)

  • Hong, Heedong;Park, Sangbong
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.3
    • /
    • pp.427-430
    • /
    • 2020
  • The multi-channel analog signal to digital signal conversion is increasing in the field of IoT and medical measurement equipments. It has chip area and power consumption constraints to use a few single or 2_channel ADC for multi_channel application. This paper described to design and implement a proposed comb filter for multi-channel, 24bit ADC. The function of proposed comb filter is verified by matlab simulation and the FPGA test board. It was fabricated using SK Hynix 0.35㎛ CMOS standard process. The performance and chip size is compared with the existing design method that uses integrator/differentiator and FIR construction. The proposed comb filter is expected to use the IoT product and medical measurement equipments that require multi-channel, low power consumption and small hardware size.

Development of the Pre-amplifier and the DSP Board for the Potable EEG Biofeedback System (포터블 뇌파 바이오피드백 시스템을 위한 전치증폭기 및 DSP 하드웨어의 설계)

  • Lee, Kyoung-Il;Ahn, Bo-Sep;Park, Jeong-Je;Lee, Seung-Ha;Cho, Jin-Ho;Kim, Myoung-Nam
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.3
    • /
    • pp.121-127
    • /
    • 2003
  • In this study, we carried out a study for implementation of the pre-amplifier and the digital signal processing part for the potable EEG biofeedback system. As we consider characteristics of the EEG signal, we designed the pre-amplifier to obtain the EEG signal to be reduced noise signal. Because the EEG signal include EOG, EMG, ECG signals etc, it is difficult to analyze of the EEG signal. Therefore, we developed DSP board and operation program which was embed the LMS adaptive filter algorithm and operate with the pre-amplifier in the real time. The simulation signal and pure EEG signal is used in the experiment. As the result, we confirmed good efficiency of developed system and possibility of application to the portable EEG biofeedback system.