• Title/Summary/Keyword: 디지털 스캔

Search Result 213, Processing Time 0.041 seconds

Development of Registration Post-Processing Technology to Homogenize the Density of the Scan Data of Earthwork Sites (토공현장 스캔데이터 밀도 균일화를 위한 정합 후처리 기술 개발)

  • Kim, Yonggun;Park, Suyeul;Kim, Seok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.5
    • /
    • pp.689-699
    • /
    • 2022
  • Recently, high productivity capabilities have been improved due to the application of advanced technologies in various industries, but in the construction industry, productivity improvements have been relatively low. Research on advanced technology for the construction industry is being conducted quickly to overcome the current low productivity. Among advanced technologies, 3D scan technology is widely used for creating 3D digital terrain models at construction sites. In particular, the 3D digital terrain model provides basic data for construction automation processes, such as earthwork machine guidance and control. The quality of the 3D digital terrain model has a lot of influence not only on the performance and acquisition environment of the 3D scanner, but also on the denoising, registration and merging process, which is a preprocessing process for creating a 3D digital terrain model after acquiring terrain scan data. Therefore, it is necessary to improve the terrain scan data processing performance. This study seeks to solve the problem of density inhomogeneity in terrain scan data that arises during the pre-processing step. The study suggests a 'pixel-based point cloud comparison algorithm' and verifies the performance of the algorithm using terrain scan data obtained at an actual earthwork site.

Full mouth rehabilitation with fixed implant-supported prosthesis using temporary denture and double digital scanning technique: a case report (임시 의치와 이중 디지털 스캐닝 기법을 활용한 전악 고정성 임플란트 수복 증례)

  • Seok-Hyun Shin;Chan-Ik Park;Se-Ha Kang;Ji-Eun Moon;Min-Seok Oh;Chul-Min Park;Woo-Jin Jeon;Seong-Gu Han;Sun-Jae Kim;Su-Jin Choi
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.3
    • /
    • pp.245-256
    • /
    • 2023
  • When restoring with a dental digital system for implant-supported prosthesis, a double digital scanning technique is required: an intraoral scan of the three-dimensional implant location and intraoral scan after placement of temporary denture or provisional prosthesis. During the intraoral scan, the use of scan body as a stable landmark can improve the accuracy of digital impression and simplify laboratory process. In this case, a full-digital system was used to plan and fabricate a custom abutment, provisional prosthesis, and definitive prosthesis. After implant placement, the scan area of the intraoral scan body connected with implant and the intraoral scan body marked on the inside of temporary denture were superimposed. Out of the superimposed files, a custom abutment and provisional prosthesis were fabricated which match the vertical dimension of temporary denture, and definitive prosthesis was fabricated based on provisional prosthesis. We report this case because result has been functionally and esthetically satisfactory by using vertical dimension and central relation set during the fabrication of temporary denture to the definitive prosthesis.

LPM-Based Digital Watermarking for Forgery Protection in Printed Materials (인쇄물의 위조 방지를 위한 LPM기반의 디지털 워터마킹)

  • Bae Jong-Wook;Lee Sin-Joo;Jung Sung-Hwan
    • Journal of Korea Multimedia Society
    • /
    • v.8 no.11
    • /
    • pp.1510-1519
    • /
    • 2005
  • We proposed a digital watermarking method that it is possible to identify the copyright because the watermark is detected in the first print-scan and to protect a forgery because the watermark is not detected in the second print-scan. The proposed algorithm uses LPM and DFT transform for the robustness to the distortion of pixel value and geometrical distortion. This methods could improve watermark detection performance and image quality by selecting maximum sampling radius in LPM transform. After analyzing the characteristics of print-scan process, we inserted the watermark in the experimentally selected frequency bands that survives robustly to the first print-scan and is not detected in the second print-scan, using the characteristic of relatively large distortion in high frequency bands of DFT As the experimental result, the original proof is possible because average similarity degree 5.13 is more than the critical value 4.0 in the first print-scan. And the detection of forgery image is also possible because average similarity degree 2.76 is less than the critical value 4.0 in the second print-scan.

  • PDF

Accuracy of implant digital scans with different intraoral scanbody shapes and library merging according to different oral exposure height (구내 스캔바디의 형태에 따른 임플란트의 디지털 스캔 정확도 및 구강 내 노출 높이에 따른 라이브러리 중첩 정확도 비교 연구)

  • Jeong, Byungjoon;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Kim, Hyeong-Seob;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.27-35
    • /
    • 2021
  • Purpose: The purpose of this study is to compare the accuracy of digital scans of implants according to different shapes of scanbodies, and to compare the accuracy of library merging according to different oral exposure height. Materials and methods: A master model with a single tooth edentulous site was prepared. For the first experiment, three types of intraoral scanbodies were prepared, divided into three groups, and the following experiments were conducted for each group: An internal hex implant was placed. The master model with the scanbody connected was scanned with a model scanner, and a master reference file (control group) was created. 10 files (experimental group) were created by performing 10 consecutive scans with an intraoral scanner. After superimposing the control and experimental groups, the following values were calculated: 1) Distance deviation of a designated point on the scanbody 2) Angle deviation of the major axis of the scanbody. For the second experiment, the scanbody scan data were prepared in 6 different heights. Library files were merged with each of the scan data. The distance and angular deviation were calculated using the 7 mm scan data as control group. Results: In the first experiment, there were no significant differences between A and B (P=.278), B and C (P=.568), and C and A (P=.711) in the distance deviations. There were no significant differences between A and B (P=.568), B and C (P=.546), and C and A (P=.112) in the angular deviations. Also, the scanbody showed significantly higher library merging accuracy in the groups with high oral exposure height (P<.5). Conclusion: There were no significant differences in scan accuracy according to the different shapes of scanbodies, and the accuracy of library merging increased according to exposure height of the scanbody in the oral cavity.

A Study on a Walking Animation Using 3D Whole Body Laser Scanned Data (인체 전신 레이저 스캔 데이터를 대상으로 한 인체 보행 애니메이션 연구)

  • Yoon, Geun-Ho;Choi, Ran;Cho, Chang-Suk
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2011.04a
    • /
    • pp.519-521
    • /
    • 2011
  • 본 연구는 3D 레이저 스캔 방법으로 계측된 인체 데이터를 대상으로 3D 아바타 애니메이션 모듈 구현을 목표로 한다. 이를 위하여 인체의 뼈 골격계 기준점을 지정한다. 기준점을 이용하여 계층에 맞는 골격을 잡아 오브젝트를 이루고 있는 정점들과 그에 해당되는 골격들을 연결하고 기구학에 의한 행동패턴을 제작하여 아바타에 애니메이션을 적용 시킨다. 이를 위하여Visual C++ OpenGL 라이브러리를 이용 하였고 인체 전신 레이저 스캔 데이터를 대상으로 하였다.

Full mouth rehabilitation with dental implant utilizing 3D digital image and CAD/CAM system: case report (3차원 디지털 영상과 CAD/CAM 시스템을 활용한 전악 임플란트 수복 증례)

  • Kang, Se-Ha;Jeong, Seung-Mi;Shin, Jae-Ok;Fang, Jeong-Whan;Kim, Dae-Hwan;Choi, Byung-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.2
    • /
    • pp.158-168
    • /
    • 2015
  • This article describes how to use digital system in a fully edentulous case that diagnosis to definitive prosthesis fabrication. While proceeding oral scan and CBCT taking, digital markers were attached on maxillary palate and lower existing denture. Using CBCT image and oral scan image, the bone contour and anatomical structures were analyzed and flapless surgical guide, customized abutment and prosthesis were made. After the osseointegration, the definitive prosthesis was fabricated using the oral scan image with scan body. It provides clinicians with a fast workflow and improves clinical efficiency.

Block Label-based Binary Connected-component Labeling using an efficient pixel-based scan mask (효율적인 화소기반 스캔마스크를 이용한 블록라벨기반 이진연결요소 라벨링)

  • Kim, Kyoil
    • Journal of Digital Convergence
    • /
    • v.11 no.4
    • /
    • pp.259-266
    • /
    • 2013
  • Binary connected-components labeling, which is widely used in the field of the pattern recognition, has been researched for a long time as one of the basic image processing techniques. Two-scan algorithm has been mainly used in the researches of the connected-components labeling. Recently, for the first scan in the two-scan algorithm, block-based labeling approaches have been used and reported as the fastest methods. In this paper, a new efficient scan mask for connected-components labeling with a block-based labeling approach is proposed. Labeling with the new pixel-based scan mask is more efficient than any other existing method. The results of the experiments show that the proposed method is faster than the existing fastest method.

Scan Chain Modification for Low Power Design (저 전력을 고려한 스캔 체인 수정에 관한 연구)

  • Park Susik;Kim Insoo;Jung Sungwon;Min Hyoung Bok
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.11a
    • /
    • pp.835-837
    • /
    • 2005
  • 이동기기들이 늘어가고 있는 추세에서 기기들의 구성품인 디지털 회로들의 테스트 시간과 전력소모는 성능에 상당한 영향을 미친다. 테스트 시간을 줄이는 방법은 병렬 코어 테스트 방법으로 줄일 수 있으나, 다양한 코어들이 동시에 테스트 되면 많은 전력 소모를 야기 시킨다. 스캔 구조를 기반으로 한 회로에서 전력 소모는 테스트 데이터의 불필요한 천이에 의해 많이 발tod한다. 그러므로 스캔 체인을 수정함으로 인해 입력 값과 출력 간의 천이를 줄일 수 있다. 제안하는 스캔 체인의 수정은 스캔 셀의 재배치와 특정한 회로의 추가로 이루어진다. 또한 회로의 추가는 그에 적합한 그룹화를 시킴으로써 최소의 수를 결정한다. 천이 주기를 해석하여 효과적인 알고리즘을 세움으로써 최적의 스캔 체인구조와 그룹을 구함으로써 전력 소모를 최소화할 수 있다.

  • PDF

Comparison of digitalized fabrication method for interim removable partial denture: case reports (두 가지 프린팅 방식으로 제작한 임시 가철성 의치의 비교: 증례 보고)

  • Yoon-Jeong Shin;Cheong-Hee Lee;Du-Hyeong Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.379-385
    • /
    • 2023
  • With the recent development of digital dentistry, fully digitalized methods for fabricating dentures, using intraoral scans and computer-aided design/computer-aided manufacturing (CAD-CAM), are getting popular. Digital methods have the advantage of simplifying the fabrication process in the clinic and laboratory, supplementing digital data. This case report shows a fully digital fabrication method for interim removable dentures in a patient with anterior tooth loss in which implant placement is impossible or delayed. Interim removable dentures were fabricated using two methods. One method is printing tooth and base parts separately and combining, and the other method is printing the whole denture at one time and coloring on the base part. Afterward, dentures were delivered and adaptation was evaluated using the triple scan technique. The extracted site was scanned intraorally (first scan) and the interim removable denture was digitally scanned both intraorally (second scan) and, after removal extraorally (Third scan). In both method, denture adaptation was shown favorable. We report this case report as both the patient and the operator were satisfied with a simplified process using a fully digital method in the clinic.