• Title/Summary/Keyword: 디지털 방사선 영상

Search Result 346, Processing Time 0.029 seconds

A Study on QA for Radiation Therapy Machine by Using Implemented Electronic Portal Imaging Device (전자포탈영상장치의 제작과 방사선치료장치의 QA 적용에 관한 연구)

  • Lee, Dong-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.6 s.312
    • /
    • pp.68-75
    • /
    • 2006
  • During cancer therapy by using high energy radiation, it is possible to improve the radiation therapy efficiency by performing a precise radiation therapy after verification of generated setup errors. In this paper, the video based electronic portal imaging device (EPID) which could display the portal image with near real time was developed to verify treatment position errors in radiation therapy instead of an analog typed portal film. This EPID system for applying QA tool of radiation therapy machine was consisted of a metal/fluorescent screen, $45^{\circ}$mirror, camera and image grabber. Radiation field verification has been performed to check quality assurance of the treatment machine itself by using this EPID system. The radiation field error was easily observed by edge detection of irradiated field size on EPID image when $0.6^{\circ}$ shift of collimator angle was generated. So, this implemented EPID system could be used as a radiation QA tool.

A Study on Quality Control for Medical Image by Using Deviation Index of Digital Radiology (디지털 방사선 영상의 편차지수를 이용한 의료영상 품질관리에 관한 연구)

  • Jeong, Hoi-Woun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.43 no.2
    • /
    • pp.115-121
    • /
    • 2020
  • In a digital radiation system using a Flat Panel Detector, we attempted to the quality control of digital radiography system using the Exposure Index and Deviation Index. Calibration was performed with the radiation quality suggested by the International Electrotechnical Commission, and through an experiment using a phantom, appropriate inspection radiation conditions applicable to medical institutions were selected. The study was conducted using the selected radiation conditions. Through those chest posterior anterior image, information such as examination conditions and exposure index was obtained. The deviation index was derived by analyzing the exposure index based on the target exposure index calculated by the phantom study. As for the analyzed exposure index, 97.1% was distributed within the range of ± 2.0 based on the deviation index. Quality control of medical images should be performed through management of inspection conditions through exposure index and deviation index and management of medical images.

Analysis of Image Quality According to BMI of Digital Chest Radiography: Focusing on Bureau of Radiological Health Evaluation (디지털 흉부 방사선 영상의 체질량지수에 따른 영상품질 분석: 미국 방사선 안전국 규정 평가표 중심으로)

  • Jin, Seong-jin;Im, In-Chul;Cho, Ji-Hwan
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.1-6
    • /
    • 2017
  • Visual evaluation of chest radiograph images is the most practical and effective method. This study compared the Body Mass Index, waist circumference, and mAs with chest radiographs of 351 women. The Bureau of Radiological Health method was used to evaluate the image quality of chest X-ray images by anatomical and physical methods. The average age of the subjects was $30.17{\pm}4.73$ and the average waist circumference was $66.91{\pm}4.67cm$. The mean Body Mass Index value was $20.21{\pm}2.23$, the mean value of mAs was $3.04{\pm}0.78$, and the mean value of Bureau of Radiological Health was $79.83{\pm}8.45$. When the Body Mass Index value increased, waist circumference and mAs mean value increased. The mean value of Body Mass Index was statistically significant(p<0.05) in Group 4 compared to Groups 1 and 2, with increasing Body Mass Index. Exposure control of the automatic exposure control system is considered to be well performed according to body thickness or Body Mass Index at the time of chest radiography. As the Body Mass Index increases, the thickness of the body increases and the breast thickness of the woman also increases. Therefore, it is considered that the exposure amount is changed by the automatic exposure control device to affect the image quality.

The Use of Continuous Confidence Judgments in ROC of Digital Radiography (디지털 X선영상 평가에서 연속확신도법 ROC의 적용)

  • Kim, Hark-Sung;Lee, In-Ja;Kim, Sung-Chul
    • Journal of radiological science and technology
    • /
    • v.32 no.2
    • /
    • pp.147-151
    • /
    • 2009
  • In general, the discrete confidence judgments that use five-step assessment method have been used to assess the medical images by ROC. TPF or FPF can be computed easily with this independent reading test. However, during experiments, it happens frequently that adequate distribution for observers is required to smoothly estimate the ROC curve. In addition, data becomes invalid for distribution of the created categories. To solve such problems or to apply the ROC interpretation to data that is not obtained from the experimental observation, the continuous confidence judgements (CCJ) has been proposed, which implements ROC interpretation using continuously-distributed experimental results without category classification has been used. As the use of CCJ to assess medical images was barely reported in Korea, we applied it to the assessment of chest digital images in this study. The results showed that a smooth ROC curve was obtained conveniently by the commercialized program and the characteristic value was measured easily. Therefore, it is recommended that this method can be applied to the assessment of digital medical images.

  • PDF

A Study on Non-Subtraction and Subtraction Technique in 3-Dimensional Angiography of the Cerebral Aneurysm (뇌동맥자루 3차원 혈관조영술에서 비감산 및 감산 기법에 관한 연구)

  • Kim, Kyung-Wan;Im, In-Chul;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.511-518
    • /
    • 2018
  • The purpose of this study was to measured the diameter, maximum diameter, maximum area and volume of the cerebral aneurysm in 53 patients who underwent three-dimensional digital angiography and three-dimensional digital subtraction angiography, which were used for the clinical diagnosis of cerebral aneurysm, image noise and radiation exposure dose of each test method were analyzed to compare clinical diagnosis differences in the cerebral aneurysm diagnosis. Three-dimensional digital angiography and three-dimensional digital subtraction angiography showed that the neck diameter, maximum diameter, maximum area, volume, and noise of the cerebral aneurysm were identical or very small. However, the three-dimensional digital angiography significantly decreased the radiation exposure dose compared to three-dimensional digital subtraction angiography. Therefore, in case of clinical diagnosis of cerebral aneurysm, three-dimensional digital angiography should be preferentially used to reduce radiation exposure dose of patient.

An Analysis of Factors That Affect Image Quality Deterioration in The Potable X-ray Examination on using Digital Wireless Detector (디지털 무선 검출기를 이용한 이동형 X선검사에서 영상품질 저하의 요인분석)

  • Yu, Young-Eun;Lim, Cheong-Hwan;Ko, Joo-Young
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.93-100
    • /
    • 2014
  • Recently the development of portable digital wireless imaging system, which acquires digital radiation images by using wireless LAN telecommunications function in an easy and fast way, provides lots of convenience for people. Considering the characteristics of portable imaging tests on emergency and critical patients, this study aims to suggest guidelines for Digital wireless detector by evaluating the effect of de-centering of focus-grid and displacement of subject in detector on the quality of image. The equipments used for this study were Elmo-T6 Digital Mobile X-ray system (SIMAZU Corp.), el' Tor ($14{\times}17$ "Wireless detector), Grid (10:1) and Chest & head phantom. After acquiring post-processing image according to dose increase and de-centering image of grid-focus and head phantom displacement image, this study compared, analyzed and evaluated these images by using a digital image analysis program by Image J. In the change of images based on dose increase, images were rough in the dose of 0.5 mAs, while there was no difference among images in the proper dose of 1~2 mAs and, especially from 2.5 mAs, average value of pixels radically decreased, affecting contrast. Over 3 mAs, contrast dropped due to saturation phenomenon of lungs. As the result of analysis using Image J program, with the increase of displacement between focus-grid and head phantom, the frequency of low pixel value also increase, causing the outline of surface image to disappear, which in turn affects contrast. For better quality imaging, a radiographer must be aware before the time of test that the image quality can be changed based on the critical patient's posture, movement, respiration, displacement of X-ray tube and distance of imaging.

An Implementation of Radiologic Imaging Device of Remote Emergency Medical System (원격응급시스템의 방사선 영상장치 구현)

  • Cho, Dong-Heon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.1
    • /
    • pp.60-65
    • /
    • 2007
  • The radiologic imaging device was implemented. It can be installed in an ambulance or used when an accident happens. After an equipment which generates X-ray generating unit with a tube in DC 12[V] had been made, a trait experiment using an oscilloscope was made. An experiment was carried out where the generated X-ray was saved as a form of a file using a digital detector. In this experiment, as a result of generating X-ray and detecting it using a digital detector, 1.67[MB]-, jpg- radical rays information could be saved. One distinct advantage of the developed radiologic imaging device is the fact that we can efficiently deal with emergency cases too far from the hospital, difficult to diagnose but treat simultaneously. By using the radiologic imaging device at the urgent scene of an accident or in a moving ambulance, we can provide the patient's X-ray information with the emergency medical specialist who is in the emergent medical center and have the patients prescribed and treated appropriately. As a result the developed emergency medical treatment can be expected.

CT Simulation Technique for Craniospinal Irradiation in Supine Position (전산화단층촬영모의치료장치를 이용한 배와위 두개척수 방사선치료 계획)

  • Lee, Suk;Kim, Yong-Bae;Kwon, Soo-Il;Chu, Sung-Sil;Suh, Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.165-171
    • /
    • 2002
  • Purpose : In order to perform craniospinal irradiation (CSI) in the supine position on patients who are unable to lie in the prone position, a new simulation technique using a CT simulator was developed and its availability was evaluated. Materials and Method : A CT simulator and a 3-D conformal treatment planning system were used to develop CSI in the supine position. The head and neck were immobilized with a thermoplastic mask in the supine position and the entire body was immobilized with a Vac-Loc. A volumetrie image was then obtained using the CT simulator. In order to improve the reproducibility of the patients' setup, datum lines and points were marked on the head and the body. Virtual fluoroscopy was peformed with the removal of visual obstacles such as the treatment table or the immobilization devices. After the virtual simulation, the treatment isocenters of each field were marked on the body and the immobilization devices at the conventional simulation room. Each treatment field was confirmed by comparing the fluoroscopy images with the digitally reconstructed radiography (DRR)/digitally composite radiography (DCR) images from the virtual simulation. The port verification films from the first treatment were also compared with the DRR/DCR images for a geometrical verification. Results : CSI in the supine position was successfully peformed in 9 patients. It required less than 20 minutes to construct the immobilization device and to obtain the whole body volumetric images. This made it possible to not only reduce the patients' inconvenience, but also to eliminate the position change variables during the long conventional simulation process. In addition, by obtaining the CT volumetric image, critical organs, such as the eyeballs and spinal cord, were better defined, and the accuracy of the port designs and shielding was improved. The differences between the DRRs and the portal films were less than 3 mm in the vertebral contour. Conclusion : CSI in the supine position is feasible in patients who cannot lie on prone position, such as pediatric patienta under the age of 4 years, patients with a poor general condition, or patients with a tracheostomy.