A Study on the Digital Mammography for Breast Cancer Patients (유방암 환자의 Digital Mammography에 관한 연구)

  • Lim, Cheong-Hwan;Lee, Sang-Ho;Jung, Hong-Ryang;Mo, Eun-Hui
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.1
    • /
    • pp.63-71
    • /
    • 2012
  • This study aimed to evaluate the accuracy of breast cancer diagnosis of digital mammography which is in the highest interest of breast imaging test, and to investigate the characteristics of breast cancer patients. For this purpose, 57 breast cancer patients who underwent breast imaging test were examined between May 2010 and June 2011. The average age of the breast cancer patients was 50.8 years old, and the most frequently occurring location was the upper outer quadrant (UOQ), accounting for 33.3%. By age, the highest occurrence rate of breast cancer was the age group of 40~49, accounting for 42.1%. As for the breast composition of the breast cancer patients, fatty breast accounted for 31.6% (18/57) and dense breast for 68.4% (39/57), indicating that nearly 70% of the breast cancer patients have dense breast. It was found that the detection rate of breast cancer was the highest (45.3%) when both microcalcification and mass are simultaneously present in the radiographic lesion of the breast imaging. In dense breast, the mass without microcalcification was lower in detection rate than fatty breast. Accordingly, the mass is the cause of raising the false negative rate in dense breast. The findings show that the false negative rate of digital mammography was 7.0% and the sensitivity 93.0%. Also, the false negative rate of dense breast was 12.8%, and the sensitivity 87.2%, indicating that the sensitivity to breast cancer in this study was higher than the dense breast of previously reported screen film mammography.

The Effect of Source to Image-Receptor Distance(SID) on Radiation Dose for Digital Chest Radiography (Digital Chest Radiography에서 방사선량에 대한 Source to Image-Receptor Distance (SID)의 영향)

  • Kwon, Soonmu;Park, Changhee;Park, Jeongkyu;Son, Woonheung;Jung, Jaeeun
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.203-210
    • /
    • 2014
  • Chest radiography has been typically performed at SID of 180 cm. Image quality and patient dose were investigated between 180 cm and 340 cm by 20 cm intervals at 120 kVp and 320 mAs with the AEC. VGA was performed for qualitative assessment and SNR was analysed for quantitative assessment on the image of the chest phantom. Patients dose was measured by ESAK and PCXMC was used for effective dose. As a result, when using the standard of SID of 180 cm which is typically used in the clinical practice, in the case of ESAK, 240 cm, 280 cm, and 320 cm were 8.7%, 11.47%, and 13.56% respectively therefore significant reduction was confirmed. In the case of effective dose, 2.89%, 4.67%, and 6.41% in the body and 5.08%, 6.09%, and 9.6% in lung were reduced. In the case of SNR, 9.04%, 8.24%, and 11.46% were respectively decreased especially, by 8.03% between SID of 260 cm and 300 cm, but SNR was 5.24 up to 340 cm. There were no significant differences in VGA thus the image is valuable in diagnosis. It is predicted that increasing SID up to 300 cm in digital chest radiography can reduce patient dose without decreasing image quality.

Detectability of Ektaspeed Plus Film, Digitized and Digora Images for Artificial Periapical Bone Lesions (Ektaspeed Plus 방사선사진, 간접 디지털 영상 및 Digora 영상의 치근단 병소의 판독능 비교)

  • Cho Bong-Hae;Nah Kyung-Soo;Lee Hee-Joo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.2
    • /
    • pp.461-470
    • /
    • 1998
  • The comparative detectability of the artificial periapical defects among Ektaspeed Plus film. digitized and digora images was evaluated. The artifical defects were made in the cancellous bone and cancellous-cortical junction with the size of 1.0×0.8mm², 1.4×1.1mm² and 2.8×2.2mm². The defects in cancellous-cortical junction extended into cortical bone with the depth of 0, 0.5 and 1.0 mm. The results were as follows : 1. In junctional defects Ektaspeed Plus film for 2.8×12.2mm² defect showed the highest detectability. But significant difference were only found between Ektaspeed Plus films and digitized images (p<0.05). 2. Almost all defects within cacellous bone were not detected except a few digitized and Digora images for the size of 2.8×2.2mm². Digora images for them showed significant differences with Ektaspeed Plus films and digitized images (p<0.05). 3. The sensitinity of all imaging modalities were 0.9 or 1.0 in junctional defects for the size of 1.4×2.2mm² and 2.8×2.2mm². For cancellous defects, Digora image showed the highest sensitivity of 0.6 for the size of 2.8×2.2mm². 4. Significant differences for change of exposure time were found in most group of Ektaspeed Plus films and digitized images (p<0.05) . But there was no significant differences in Digora images for cacellous defects.

  • PDF

A Deep Learning Model for Judging Presence or Absence of Lesions in the Chest X-ray Images (흉부 디지털 영상의 병변 유무 판단을 위한 딥러닝 모델)

  • Lee, Jong-Keun;Kim, Seon-Jin;Kwak, Nae-Joung;Kim, Dong-Woo;Ahn, Jae-Hyeong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.2
    • /
    • pp.212-218
    • /
    • 2020
  • There are dozens of different types of lesions that can be diagnosed through chest X-ray images, including Atelectasis, Cardiomegaly, Mass, Pneumothorax, and Effusion. Computed tomography(CT) test is generally necessary to determine the exact diagnosis and location and size of thoracic lesions, however computed tomography has disadvantages such as expensive cost and a lot of radiation exposure. Therefore, in this paper, we propose a deep learning algorithm for judging the presence or absence of lesions in chest X-ray images as the primary screening tool for the diagnosis of thoracic lesions. The proposed algorithm was designed by comparing various configuration methods to optimize the judgment of presence of lesions from chest X-ray. As a result, the evaluation rate of lesion presence of the proposed algorithm is about 1% better than the existing algorithm.

Evaluation of the Usefulness of Images according to the Use of the Field Size in Mastoid Process Radiography (유양돌기 방사선검사 시 조사야 사용법에 따른 영상의 유용성 평가)

  • Jung, Hong-Ryang
    • Journal of radiological science and technology
    • /
    • v.44 no.5
    • /
    • pp.435-441
    • /
    • 2021
  • The purpose of this study was to evaluate the quality of images and to quantitatively measure and analyze the dose of scattered ray to the organs, which were highly sensitive to radiation according to the use of cylinder cone in mastoid process radiography. When the cylinder cone was not used, the SID was 100cm and the field size was 24 × 36 cm(864 cm2). When using the cylinder cone which was a circle, the SID was 70 cm, the radius was 10.5 cm and field size was 86.59 cm2. As a result of the study, SNR of the image quality evaluation was measured to be 2.58 for Law method and 3.90 for Stenver's method when not using cylinder cone, and 2.87 for Law method and 14.67 for Stenver's method when using cylinder cone. CNR was measured to be 0.03 for Law method and 0.04 for Stenver's method when cylinder cone was not used, and 0.04 for Law method and 0.05 for Stenver's method when using cylinder cone. When the cylinder cone was not used, the scattered ray dose was measured to be 0.10 mGy in the right eyeball, 0.30 mGy in the left eyeball, 2.02 mGy in the parotid gland, and 0.29 mGy in the thyroid gland for Law method and to be 0.03 mGy in the right eyeball, 0.12 mGy in the left eyeball, 1.43 mGy in the parotid gland, and 0.09 mGy in the thyroid gland for Stenver's method. When the cylinder cone was used, the scattered ray dose was measured to be 0.05 mGy in the right eyeball, 0.03 mGy in the left eyeball and the parotid and thyroid gland were below the measurable values for Law method and all areas were below the measurable values for Stenver's method. This was found to be statistically significant(p<0.000).

A Study on Image Change according to Grid Ratio in Digital Radiography (디지털 방사선에서 격자 비에 따른 영상변화에 관한 연구)

  • Sung-Hun Jeong
    • Journal of radiological science and technology
    • /
    • v.46 no.2
    • /
    • pp.89-97
    • /
    • 2023
  • With the introduction of the D.R system, the grid with high removal rate of scattered radiation is selected and used without considering the grid performance evaluation. Despite the high removal rate of scattered radiation belonging to high grid ratio, it is also possible to see the cut-off phenomenon in which the primary ray involved in the formation of image could be removed as well. Thus, the purpose of this study is to provide the basic data for researches on the usefulness of using the grid by presenting the appropriate grid ratio in the D.R system through the measurement of image in grid such as non-grid, 6:1, 8:1, 10:1, 12:1. The equipments used for this study were radiation generator with grid in 12:1, 10:1, 8:1, 6:1, indirect-type detector, and acryl phantom. As the study for image evaluation, this study measured the SNR, PSNR, MSE, and Entropy. In the results of this study, the PSNR was the highest in 6:1 and the lowest in 8:1. The SNR was high in 6:1 and 8:1, and the lowest in 12:1. In case of Entropy, it was high in 8:1 and 10:1, and the lowest in 12:1. Therefore, when the grid is used, it would be more proper to choose the grid in 8:1 or 10:1 with less loss in information content of primary ray rather than the high grid ratio showing the increased patient exposure dose.

National Data Analysis of General Radiography Projection Method in Medical Imaging (영상의학검사 일반촬영 분야의 촬영기법에 대한 분석)

  • Kim, Jung-Su;Kim, Jung-Min;Lee, Young-Han;Seo, Deok-Nam;Choi, In-Seok;Nam, So-Ra;Yoon, Yong-Su;Kim, Hyun-Ji;Min, Hye-Lim;Her, Jea;Han, Seong-Gyu
    • Journal of radiological science and technology
    • /
    • v.37 no.3
    • /
    • pp.169-175
    • /
    • 2014
  • According to database of medical institutions of health insurance review & assessment service in 2013, 1118 hospitals and clinics have department of radiology in Korea. And there are CT, fluoroscopic and general radiographic equipment in those hospitals. Above all, general radiographic equipment is the most commonly used in the radiology department. And most of the general radiographic equipment are changing the digital radiography system from the film-screen types of the radiography system nowadays. However, most of the digital radiography department are used the film-screen types of the radiography system. Therefore, in this study, we confirmed present conditions of technical items for general radiography used in hospital and research on general radiographic techniques in domestic medical institutions. We analyzed 26 radiography projection method including chest, skull, spine and pelvis which are generally used in the radiography department.

A Study on the Development Direction of Medical Image Information System Using Big Data and AI (빅데이터와 AI를 활용한 의료영상 정보 시스템 발전 방향에 대한 연구)

  • Yoo, Se Jong;Han, Seong Soo;Jeon, Mi-Hyang;Han, Man Seok
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.11 no.9
    • /
    • pp.317-322
    • /
    • 2022
  • The rapid development of information technology is also bringing about many changes in the medical environment. In particular, it is leading the rapid change of medical image information systems using big data and artificial intelligence (AI). The prescription delivery system (OCS), which consists of an electronic medical record (EMR) and a medical image storage and transmission system (PACS), has rapidly changed the medical environment from analog to digital. When combined with multiple solutions, PACS represents a new direction for advancement in security, interoperability, efficiency and automation. Among them, the combination with artificial intelligence (AI) using big data that can improve the quality of images is actively progressing. In particular, AI PACS, a system that can assist in reading medical images using deep learning technology, was developed in cooperation with universities and industries and is being used in hospitals. As such, in line with the rapid changes in the medical image information system in the medical environment, structural changes in the medical market and changes in medical policies to cope with them are also necessary. On the other hand, medical image information is based on a digital medical image transmission device (DICOM) format method, and is divided into a tomographic volume image, a volume image, and a cross-sectional image, a two-dimensional image, according to a generation method. In addition, recently, many medical institutions are rushing to introduce the next-generation integrated medical information system by promoting smart hospital services. The next-generation integrated medical information system is built as a solution that integrates EMR, electronic consent, big data, AI, precision medicine, and interworking with external institutions. It aims to realize research. Korea's medical image information system is at a world-class level thanks to advanced IT technology and government policies. In particular, the PACS solution is the only field exporting medical information technology to the world. In this study, along with the analysis of the medical image information system using big data, the current trend was grasped based on the historical background of the introduction of the medical image information system in Korea, and the future development direction was predicted. In the future, based on DICOM big data accumulated over 20 years, we plan to conduct research that can increase the image read rate by using AI and deep learning algorithms.

Association of visceral fat obesity and other lifestyle factors with prostate cancer (비만으로 인한 전립선암 발생의 영향연구 : 복부비만도 측정과 그 외 생활 요인)

  • Kim, Myeong-Seong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.17 no.1
    • /
    • pp.19-31
    • /
    • 2015
  • 최근 우리나라의 암 발생률은 꾸준히 증가추세에 있고 그 중에서도 전립선암은 갑상선암을 제외했을 때 남성에서 가장 높은 증가 추세를 보이고 있는 암이다. 전립선암은 그 동안 선진국에서 주로 발병하는 것으로 알려진 암 종이지만 서구화된 식습관과 생활 행태 변화로 인하여 국내에서도 발생률이 증가하는 것으로 추정하고 있다. 따라서 국내 환경에 맞는 내장 지방 분포와 같은 정확한 비만도 측정을 통해 우리나라에서 증가율 1위를 보이고 있는 전립선암 발생의 원인 관계를 찾고자 한다. 본 연구는 환자와 정상군 비교를 하는 환자-대조군 연구이고 본 연구를 위하여 임상시험 윤리위원회 (IRB) 승인을 받았다 (NCC2014-0124). 환자군은 2014년 8월 1일부터 2015년 1월 6일 까지 국립암센터를 방문하여 전립선암을 진단받고 수술과 항암치료 그리고 방사선 치료를 시작하지 않은 초진을 대상으로 하였고, 정상군은 2009년 11월부터 2014년 9월 30일까지 공단검진을 목적으로 국립암센터를 방문한 정상인을 대상으로 하였다. 전립선암 연구는 환자 총 52명에 평균 66세 (51 - 82세)이고 정상군은 총 50명에 평균 64세 (59 - 75세) 이다. 모든 연구 대상자들의 생활 요인 평가를 위하여 암 가족력, 흡연, 음주 상태, 운동, 등을 추가적으로 설문 조사하였다. MRI 영상의 배꼽 주위에서의 내장 지방과 피하지방을 전용 분석 컴퓨터를 활용하여 측정 하였다. 복부비만율은 환자군과 정상군에서뿐만 아니라 (p = 0.03), 전립선암 악성도와 (Gleasonscore; p = 0.001)도 통계적 차이를 나타냈다. 하지만 BMI 결과와는 전립선암 발생과 악성도에서 무관함을 보인 것에 반해 허리둘레는 전립선암의 발생에 영향을 미치는 결과를 나타났다. 한편 전립선암의 또 다른 악성도 지표인 PSA는 비만 측정치와의 상관성이 Gleason score와 보다 대체적으로 낮게 나타났다. 학력, 운동량, 흡연, 음주 상태와 같은 생활 특성에 따른 전립선암 발생의 영향 관계는 뚜렷하지 않았다. 결론적으로 본 연구를 통해서 전립선암의 발생 위험도와 악성도 지표로 복부 비만도가 유용함을 나타냈고 간단한 신체 계측 지표 활용으로는 BMI보다 허리둘레 측정치가 더 암 발생의 연관성이 높음을 보였다.

  • PDF

Evaluation of Real-time Measurement Liver Tumor's Movement and $Synchrony^{TM}$ System's Accuracy of Radiosurgery using a Robot CyberKnife (로봇사이버나이프를 이용한 간 종양의 실시간 움직임 측정과 방사선수술 시 호흡추적장치의 정확성 평가)

  • Kim, Gha-Jung;Shim, Su-Jung;Kim, Jeong-Ho;Min, Chul-Kee;Chung, Weon-Kuu
    • Radiation Oncology Journal
    • /
    • v.26 no.4
    • /
    • pp.263-270
    • /
    • 2008
  • Purpose: This study aimed to quantitatively measure the movement of tumors in real-time and evaluate the treatment accuracy, during the treatment of a liver tumor patient, who underwent radiosurgery with a Synchrony Respiratory motion tracking system of a robot CyberKnife. Materials and Methods: The study subjects included 24 liver tumor patients who underwent CyberKnife treatment, which included 64 times of treatment with the Synchrony Respiratory motion tracking system ($Synchrony^{TM}$). The treatment involved inserting 4 to 6 acupuncture needles into the vicinity of the liver tumor in all the patients using ultrasonography as a guide. A treatment plan was set up using the CT images for treatment planning uses. The position of the acupuncture needle was identified for every treatment time by Digitally Reconstructed Radiography (DRR) prepared at the time of treatment planning and X-ray images photographed in real-time. Subsequent results were stored through a Motion Tracking System (MTS) using the Mtsmain.log treatment file. In this way, movement of the tumor was measured. Besides, the accuracy of radiosurgery using CyberKnife was evaluated by the correlation errors between the real-time positions of the acupuncture needles and the predicted coordinates. Results: The maximum and the average translational movement of the liver tumor were measured 23.5 mm and $13.9{\pm}5.5\;mm$, respectively from the superior to the inferior direction, 3.9 mm and $1.9{\pm}0.9mm$, respectively from left to right, and 8.3 mm and $4.9{\pm}1.9\;mm$, respectively from the anterior to the posterior direction. The maximum and the average rotational movement of the liver tumor were measured to be $3.3^{\circ}$ and $2.6{\pm}1.3^{\circ}$, respectively for X (Left-Right) axis rotation, $4.8^{\circ}$ and $2.3{\pm}1.0^{\circ}$, respectively for Y (Crania-Caudal) axis rotation, $3.9^{\circ}$ and $2.8{\pm}1.1^{\circ}$, respectively for Z (Anterior-Posterior) axis rotation. In addition, the average correlation error, which represents the treatment's accuracy was $1.1{\pm}0.7\;mm$. Conclusion: In this study real-time movement of a liver tumor during the radiosurgery could be verified quantitatively and the accuracy of the radiosurgery with the Synchrony Respiratory motion tracking system of robot could be evaluated. On this basis, the decision of treatment volume in radiosurgery or conventional radiotherapy and useful information on the movement of liver tumor are supposed to be provided.