• Title/Summary/Keyword: 디지털 방사선

Search Result 490, Processing Time 0.029 seconds

A Study on Accuracy and Usefulness of In-vivo Dosimetry in Proton Therapy (양성자 치료에서 생체 내 선량측정 검출기(In-vivo dosimety)의 정확성과 유용성에 관한 연구)

  • Kim, Sunyoung;Choi, Jaehyock;Won, Huisu;Hong, Joowan;Cho, Jaehwan;Lee, Sunyeob;Park, Cheolsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.171-180
    • /
    • 2014
  • In this study, the authors attempted to measure the skin dose by irradiating the actual dose on to the TLD(Thermo-Luminescence Dosimeter) and EBT3 Film used as the In-vivo dosimetry after planning the same treatment as the actual patient on a Phantom, because the erythema or dermatitis is frequently occurred on the patients' skin at the time of the proton therapy of medulloblastoma patient receiving the proton therapy. They intended to know whether there is the usefulness for the dosimetry of skin by the comparative analysis of the measured dose values with the treatment planned skin dose. The CT scan from the Brain to the Pelvis was done by placing a phantom on the CSI(Cranio-spinal irradiation) Set-up position of Medulloblastoma, and the treatment Isocenter point was aligned by using DIPS(Digital Image Positioning System) in the treatment room after planning a proton therapy. The treatment Isocenter point of 5 areas that the proton beam was entered into them, and Markers of 2 areas shown in the Phantom during CT scans, that is, in all 7 points, TLD and EBT3 Film pre-calibrated are alternatively attached, and the proton beam that the treatment was planned, was irradiated by 10 times, respectively. As a result of the comparative analysis of the average value calculated from the result values obtained by the repeated measurement of 10 times with the Skin Dose measured in the treatment planning system, the measured dose values of 6 points, except for one point that the accurate measurement was lacked due to the measurement position with a difficulty showed the distribution of the absolute dose value ${\pm}2%$ in both TLD and EBT Film. In conclusion, in this study, the clinical usefulness of the TLD and EBT3 Film for the Enterance skin dose measurement in the first proton therapy in Korea was confirmed.

The comparison of cephalometric measurements between measuring methods in digital and conventional lateral cephalometric radiograph (디지털 및 일반 측방두부규격방사선사진에서 측정 방법에 따른 계측치의 비교)

  • Kim Mi-Ja;Huh Kyung-Hoe;Yi Won-Jin;Heo Min-Suk;Lee Sam-Sun;Lee Jin-Koo;Ahn Byoung-Keun;Choi Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.35 no.1
    • /
    • pp.15-23
    • /
    • 2005
  • Purpose : To compare cephalometric measurement between measuring methods in digital and conventional lateral cephalometric radiograph. Materials and Methods : Twenty digital and conventional lateral cephalometric radiographs were selected. In digital group, cephalometric measurements were performed manually using hardcopies and automatically using $V-Ceph^{TM}$ program on the monitor. In conventional group, the same measurements were performed manually on conventional films, and for automatic measurement conventional films were digitized by scanner. All measurements were performed twice by 4 observers, and 24 cephalometric variables were calculated and the time spent for each measurement was recorded. The differences in measurements data and the time spent for each measurement were compared within each group. Intra-observer and inter-observer comparisons were performed. Results : In both groups, no statistically significant difference between manual and automatic measurements was observed and most of the variables didn't show statistically significant differences between methods. The observer with less experience tended to show statistically significant differences of measurements between methods, and differences from other observers. The differences of measurements between methods in digital group were lesser than those of conventional group with statistical significance in 8 variables out of 24. With automatic method and in digital group, the spent time was shorter. Conclusion : With direct digital radiograph, automatic method using manually idenitified landmarks can be preferable in cephalometric analysis. (Korean J Oral Maxillofac Radiol 2005; 35 : 15-23)

  • PDF

Fixed prosthesis restoration in edentulous patient fully implanted without considering definitive prosthesis: A case report (최종 보철물에 대한 고려 없이 전악 임플란트 식립된 환자의 고정성 보철 수복 증례)

  • Chun, Young-Hoon;Pae, Ahran;Kwon, Kung-Rock;Kim, Hyeong-Seob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.4
    • /
    • pp.427-435
    • /
    • 2017
  • The most important factor in the treatment of fully edentulous patients using implants is the shape of the definitive prosthesis. After the shape of the definitive prosthesis is determined, residual bone analysis and selection of the implant type, number and position should be followed. In this case, for restoration of an edentulous patient fully implanted (except the maxillary right lateral incisor) without considering definitive prosthesis, facial esthetics and possibility of fixed type prosthesis were evaluated using complete denture. It was determined that the fixed type prosthesis was possible. Implants that could not be used for the definitive prosthesis were excluded from the treatment plan and fixed type provisional restorations were fabricated. After four months of provisional restorations, the patient showed stable occlusion and esthetic satisfaction. Definitive prosthesis was made of zirconia using CAD/CAM (computer aided design and computer aided manufacturing). The results were satisfactory during the 3 months of follow-up period after termination of treatment.

A Study on the Improvement of Digital Periapical Images using Image Interpolation Methods (영상보간법을 이용한 디지털 치근단 방사선영상의 개선에 관한 연구)

  • Song Nam-Kyu;Koh Kawng-Joon
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.2
    • /
    • pp.387-413
    • /
    • 1998
  • Image resampling is of particular interest in digital radiology. When resampling an image to a new set of coordinate, there appears blocking artifacts and image changes. To enhance image quality, interpolation algorithms have been used. Resampling is used to increase the number of points in an image to improve its appearance for display. The process of interpolation is fitting a continuous function to the discrete points in the digital image. The purpose of this study was to determine the effects of the seven interpolation functions when image resampling in digital periapical images. The images were obtained by Digora, CDR and scanning of Ektaspeed plus periapical radiograms on the dry skull and human subject. The subjects were exposed to intraoral X-ray machine at 60kVp and 70 kVp with exposure time varying between 0.01 and 0.50 second. To determine which interpolation method would provide the better image, seven functions were compared; (1) nearest neighbor (2) linear (3) non-linear (4) facet model (5) cubic convolution (6) cubic spline (7) gray segment expansion. And resampled images were compared in terms of SNR(Signal to Noise Ratio) and MTF(Modulation Transfer Function) coefficient value. The obtained results were as follows ; 1. The highest SNR value(75.96dB) was obtained with cubic convolution method and the lowest SNR value(72.44dB) was obtained with facet model method among seven interpolation methods. 2. There were significant differences of SNR values among CDR, Digora and film scan(P<0.05). 3. There were significant differences of SNR values between 60kVp and 70kVp in seven interpolation methods. There were significant differences of SNR values between facet model method and those of the other methods at 60kVp(P<0.05), but there were not significant differences of SNR values among seven interpolation methods at 70kVp(P>0.05). 4. There were significant differences of MTF coefficient values between linear interpolation method and the other six interpolation methods (P< 0.05). 5. The speed of computation time was the fastest with nearest -neighbor method and the slowest with non-linear method. 6. The better image was obtained with cubic convolution, cubic spline and gray segment method in ROC analysis. 7. The better sharpness of edge was obtained with gray segment expansion method among seven interpolation methods.

  • PDF

Proximal caries detection using digital subtraction radiography in the artificial caries activity model (인공 치아우식 발생 모델에서 디지털 방사선 공제술을 이용한 인접면 치아우식증의 진단)

  • Park, Jeong-Hoon;Choi, Yong-Suk;Hwang, Eui-Hwan;Lee, Gi-Ja;Choi, Sam-Jin;Park, Young-Ho;Kim, Kyung-Sook;Jin, Hyun-Seok;Hong, Kyung-Won;Oh, Berm-Seok;Park, Hun-Kuk
    • Imaging Science in Dentistry
    • /
    • v.39 no.1
    • /
    • pp.35-39
    • /
    • 2009
  • Purpose: The purpose of the experiment was to evaluating the diagnostic ability of dental caries detection using digital subtraction in the artificial caries activity model. Materials and Methods: Digital radiographies of five teeth with 8 proximal surfaces were obtained by CCD sensor (Kodak RVG 6100 using a size #2). The digital radiographic images and subtraction images from artificial proximal caries were examined and interpreted. In this study, we proposed novel caries detection method which could diagnose the dental proximal caries from single digital radiographic image. Results: In artificial caries activity model, the range of lesional depth was $572-1,374{\mu}m$ and the range of lesional area was $36.95-138.52mm^2$. The lesional depth and the area were significantly increased with demineralization time (p<0.001). Furthermore, the proximal caries detection using digital subtraction radiography showed high detection rate compared to the proximal caries examination using simple digital radiograph. Conclusion: The results demonstrated that the digital subtraction radiography from single radiographic image of artificial caries was highly efficient in the detection of dental caries compared to the data from simple digital radiograph.

  • PDF

Retrospective study on marginal bone loss around maxillary anterior implants with or without bone graft (상악 전치부에서 골 이식 유무에 따른 임플란트 변연골 소실에 관한 후향적 연구)

  • Hwang, Hee-Sun;Jung, Ji-Hye;Kim, Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.2
    • /
    • pp.103-109
    • /
    • 2016
  • Purpose: This study is to evaluate the clinical significance of implantation with simultaneous bone graft by comparing the marginal bone loss around maxillary anterior implants with or without bone graft. Materials and methods: Patients treated with implant-retained restorations on maxillary anterior region at Implant Center, Dental Hospital, Wonkwang University between June 2011 and May 2014 were included in this study. Date of implant placement, implant diameter, implant length, implant-abutment connection type and whether the bone graft was done were investigated. The patient's periapical radiographs taken immediately after implantation and at the most recent visit were compared. Marginal bone loss was measured using Emago advanced v5.6 program (Oral diagnostic systems, Amsterdam, Netherlands). Statistical analysis was done in independent t-test by using SPSS 22.0 program. Results: As a result of observing on 83 implants (without bone graft: 44, with bone graft: 39) of 52 patients for 6 - 45 months (average: 18.4 months), implants without bone graft showed $1.42{\pm}0.42mm$, implants with bone graft showed $1.28{\pm}0.45mm$ of marginal bone loss. Conclusion: In limitations of this study, implants with simultaneous bone graft had significantly less marginal bone loss than implants without bone graft.

A COMPARISON OF PERIAPICAL RADIOGRAPHS AND THEIR DIGITAL IMAGES FOR THE DETECTION OF SIMULATED INTERPROXIMAL CARIOUS LESIONS (모의 인접면 치아우식병소의 진단을 위한 구내 표준방사선사진과 그 디지털 영상의 비교)

  • Kim Hyun;Chung Hyun-Dae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.2
    • /
    • pp.279-290
    • /
    • 1994
  • The purpose of this study was to compare the diagnostic accuracy of periapical radiographs and their digitized images for the detection of simulated interproximal carious lesions. A total of 240 interproximal surfaces was used in this study. The case sample was composed of 80 anterior teeth, 80 bicuspids and 80 molars which were prepared in order to distribute the surfaces from carious free to those containing simulated carious lesions of varying depths (0.5㎜, 0.8㎜, and 1.2㎜). The periapical radiographs were taken by paralleling technique and film used was Kodak Ektaspeed(E group). All radiographs were evaluated by five dentist to recognize the true status of simulated carious lesion. They were asked to give a score of 0, 1, 2, or 3. Digitized images were obtained using a commercial video processor(FOTOVIX Ⅱ- XS). And the computer system was 486 DX PC with PC Vision and frame grabber. The 17' display monitor had a resolution of 1280×1024 pixels(0.26㎜ dot pitch). But the one frame of the intraoral radiograph has a resolution of 700×480 pixels and each pixel has a grey level value of 256. All the radiographs and digital images were viewed under uniform subdued lighting in the same reading room. After a week the second interpretation was performed in the same condition. The detection of lesions on the monitor was compared with the finding of simulated interproximal carious lesions on the film images. The results were as follows: 1. When the scoring criteria was dichotomous ; lesion present and not present 1) The overall sensitivity, specificity and diagnostic accuracy of periapical radiographs and their digital images showed no statistically significant difference. 2) The sensitivity and specificity according to the region of teeth and the grade of lesions showed no statistically significant difference between periapical radiographs and their digital images. 2. When estimate the grade of lesions ; score 0, 1, 2, 3 1) The overall diagnostic accuracy was 53.3% on the intraoral films and 52.9% on digital images. There was no significant difference. 2) The diagnostic accuracy according to the region of teeth showed no statistically significant difference between periapical radiographs and their digital images. 3. The degree of agreement and reliability 1) Using gamma value to show the degree of agreement, there was similarity between periapical films and digital images. 2) The reliability of each twice interpretation of periapical films and digital images showed no statistically significant difference. In all cases P value was greater than 0.05, showing that both techniques can be used to detect the incipient and moderate interproximal carious lesions with similar accuracy.

  • PDF

An Assessment on Cu-Equivalent Image of Digital Intraoral Radiography (디지털구내방사선사진의 구리당량화상에 대한 평가)

  • KIM JAE-DUK
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.33-42
    • /
    • 1999
  • Geometrically standardized dental radiographs were taken. We prepared Digital Cu-Equivalent Image Analyzing System for quantitative assessment of mandible bone. Images of radiographs were digitized by means of Quick scanner and personal Mcquintosh computer. NIH image as software was used for analyzing images. A stepwedge composed of 10 steps of 0.1mm copper foil in thickness was used for reference material. This study evaluated the effects of step numbers of copper wedge adopted for calculating equation. kVp and exposure time on the coefficient of determination(r²)of the equation for conversion to Cu-equivalent image and the coefficient of variation and Cu-Eq value(mm) measured at each copper step and alveolar bone of the mandible. The results were as follows: 1. The coefficients of determination(r²) of 10 conversion equations ranged from 0.9996 to 0.9973(mean=0.9988) under 70kVp and 0.16 sec. exposure. The equation showed the highest r was Y=4.75614612-0.06300524x +0.00032367x² -0.00000060x³. 2. The value of r² became lower when the equation was calculated from the copper stepwedge including 1.0mm step. In case of including 0mm step for calculation. the value of r showed variability. 3. The coefficient of variation showed 0.11, 0.20 respectively at each copper step of 0.2, 0.1mm in thickness. Those of the other steps to 0.9 mm ranged from 0.06 to 0.09 in mean value. 4. The mean Cu-Eq value of alveolar bone was 0.14±0.02mm under optimal exposure. The values were lower than the mean under the exposures over 0.20sec. in 60kVp and over 0.16sec. in 70kVp. 5. Under the exposure condition of 60kVp 0.16sec.. the coefficient of variation showed 0.03. 0.05 respectively at each copper-step of 0.3, 0.2mm in thickness. The value of r² showed over 0.9991 from both 9 and 10 steps of copper. The Cu-Eq value and the coefficient of variation was 0.14±0.01mm and 0.07 at alveolar bone respectively. In summary. A clinical application of this system seemed to be useful for assessment of quantitative assessment of alveolar provided high coefficient of determination is obtained by the modified adoption of copper step numbers and the low coefficient of variation for the range of Cu-Equivalent value of alveolar bone from optimal kVp and exposure time for each x-ray machine.

  • PDF

A study of trabecular bone strength and morphometric analysis of bone microstructure from digital radiographic image (디지털방사선영상에서 추출한 해면질골의 강도와 미세구조의 형태계측학적 분석에 대한 연구)

  • Han Seung-Yun;Lee Sun-Bok;Oh Sung-Ook;Heo Min-Suk;Lee Sam-Sun;Choi Soon-Chul;Park Tae-Won;Kim Jong-Dae
    • Imaging Science in Dentistry
    • /
    • v.33 no.2
    • /
    • pp.113-119
    • /
    • 2003
  • Purpose : To evaluate the relationship between morphometric analysis of bone microstructure from digital radiographic image and trabecular bone strength. Materials and Methods : One hundred eleven bone specimens with 5 mm thickness were obtained from the mandibles of 5 pigs. Digital images of specimens were taken using a direct digital intraoral radiographic system. After selection of ROI (100 × 100 pixel) within the trabecular bone, mean gray level and standard deviation were obtained. Fractal dimension and the variants of morphometric analysis (trabecular area, periphery, length of skeletonized trabeculae, number of terminal point, number of branch point) were obtained from ROI. Punch sheer strength analysis was performed using Instron (model 4465, Instron Corp., USA). The loading force (loading speed 1 mm/min) was applied to ROI of bone specimen by a 2 mm diameter punch. Stress-deformation curve was obtained from the punch sheer strength analysis and maximum stress, yield stress, Young's modulus were measured. Results: Maximum stress had a negative linear correlation with mean gray level and fractal dimension significantly (p<0.05). Yield stress had a negative linear correlation with mean gray level, periphery, fractal dimension and the length of skeletonized trabeculae significantly (p < 0.05). Young's modulus had a negative linear correlation with mean gray level and fractal dimension significantly (p < 0.05). Conclusions : The strength of cancellous bone exhibited a significantly linear relationship between mean gray level, fractal dimension and morphometric analysis. The methods described above can be easily used to evaluate bone quality clinically.

  • PDF

Design and Implementation of a Systemic Learner-centered Teaching Method Model - Focusing on H University - (체계적인 학습자 중심의 교수법 모델 개발 및 구현 - H 대학을 중심으로 -)

  • Kim, Sun-Hee;Cho, Young-Sik;Kim, Bo-Young;Han, Yong-Su
    • Journal of Korea Entertainment Industry Association
    • /
    • v.15 no.5
    • /
    • pp.163-173
    • /
    • 2021
  • This study tried to develop and implement a class model that can apply the teaching method that can operate learner-centered classes in university education to the class operation of the entire university, not individuals. For the development of the instructional model, the final model was derived through analysis of prior research, expert review, derivation of instructional model and design principles, pilot operation, primary questionnaire analysis, model and design strategy revision, and secondary questionnaire analysis. Shift_N+1 class consists of 6 models, and each model was divided into 3 parts. It was a preliminary learning using video, a face-to-face class for question-and-answer and in-depth learning on the core content, and feedback and process evaluation for individual student. We have built our own computer system so that we can implement this every week. The teaching method model that can apply the learner-centered curriculum to all classes at the university was standardized. The Shift_N+1 teaching method seeks to maximize the learner-centered learning effect by reflecting the characteristics of the subject, and to improve the quality of education by identifying students' achievements by week.