Image Quality Evaluation of Medical Image Enhancement Parameters in the Digital Radiography System (디지털 방사선시스템에서 영상증강 파라미터의 영상특성 평가)

  • Kim, Chang-Soo;Kang, Se-Sik;Ko, Seong-Jin
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.6
    • /
    • pp.329-335
    • /
    • 2010
  • Digital imaging detectors can use a variety of detection materials to convert X-ray radiation either to light or directly to electron charge. Many detectors such as amorphous silicon flat panels, CCDs, and CMOS photodiode arrays incorporate a scintillator screen to convert x-ray to light. The digital radiography systems based on semiconductor detectors, commonly referred to as flat panel detectors, are gaining popularity in the clinical & hospital. The X-ray detectors are described between a-Silicon based indirect type and a-Selenium based direct type. The DRS of detectors is used to convert the x-ray to electron hole pairs. Image processing is described by specific image features: Latitude compression, Contrast enhancement, Edge enhancement, Look up table, Noise suppression. The image features are tuned independently. The final enhancement result is a combination of all image features. The parameters are altered by using specific image features in the different several hospitals. The image in a radiological report consists of two image evaluation processes: Clinical image parameters and MTF is a descriptor of the spatial resolution of a digital imaging system. We used the edge test phantom and exposure procedure described in the IEC 61267 to obtain an edge spread function from which the MTF is calculated. We can compare image in the processing parameters to change between original and processed image data. The angle of the edge with respect to the axes of detector was varied in order to determine the MTF as a function of direction. Each MTF is integrated within the spatial resolution interval of 1.35-11.70 cycles/mm at the 50% MTF point. Each image enhancement parameters consists of edge, frequency, contrast, LUT, noise, sensitometry curve, threshold level, windows. The digital device is also shown to have good uniformity of MTF and image parameters across its modality. The measurements reported here represent a comprehensive evaluation of digital radiography system designed for use in the DRS. The results indicate that the parameter enables very good image quality in the digital radiography. Of course, the quality of image from a parameter is determined by other digital devices in addition to the proper clinical image.

Development of Image Quality Evaluation Program for Digital Diagnostic Radiography (디지털진단의료영상 화질평가 프로그램 개발)

  • Kang, Bo-Sun
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.2
    • /
    • pp.5-10
    • /
    • 2008
  • Most of the diagnostic medical radiography are rapidly replaced by digital imaging systems recently. Although with the current transition of analog to digital most of the exposure conditions and parameters are still on the basis of film-screen analog system. Moreover the evaluation of acquired digital radiographic image is not fulfilled normally because of the difficulties in handling the digital raw data. The user friendly windows program for the evaluations of digital radiographic image was developed on the MatLab platform. The program has functions for the calculation of the contrast profile, NPS(noise power spectrum), MTF(modulation transfer function), and NEQ(noise equivalent quanta).

  • PDF

Bone loss Detection in Dental Digital X-ray Image by Structure Analysis (구조적 분석을 이용한 치과용 디지털 X-ray 영상에서의 골조직 변화 검출에 관한 연구)

  • Ahn, Yong-Hak;Chae, Ok-Sam
    • The KIPS Transactions:PartB
    • /
    • v.11B no.3
    • /
    • pp.275-280
    • /
    • 2004
  • In this paper, we propose automatic subtraction radiography algorithms to overcome conventional subtraction radiography's defects by applying image processing technique. In order to reach these goals, this paper suggests the image alignment method that is necessary for getting subtraction image and ROI(Region Of Interest) focused on a selection method using the structure characteristics in target images. Therefore, we use these methods because they give accurary, consistency and objective information or data to results. According to the results, easily and visually we can identify fine difference int the affected parts wether they have problems or not.

Evaluation of the Filling Sodium States Inside the Fuel rod of Sodium-Cooled Fast Reactor by Optimized Spatial Resolution in Medical Digital Radiographic Images (의료용 디지털방사선영상의 공간분해능 최적화에 의한 소듐냉각고속로 연료봉 내부의 소듐 충전상태 평가)

  • Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.2
    • /
    • pp.117-124
    • /
    • 2016
  • The purpose of this study was tried to evaluate the filling sodium states inside the fuel rod of sodium-cooled fast reactor by digital medical X-ray. We used the diagnostic X-ray generators in digital radiography (DR). This study have found the optimal conditions by changing the effective focal spot size of X-ray tube and post-processing of the DR method with a tungsten edge plate in order to ensure excellent sharpness At this time, the sharpness and resolution were evaluated using the MTF (modulation transfer function). As a result, this study obtained a spatial resolution of 3.871 lp/mm (0.1 MTF), 3.290 lp/mm (0.5 MTF) when implemented the contrast strengthen post-processing in small focal spot. In this research, the result is able to evaluate the level of sodium inside the fuel rod by using the diagnostic X-ray generators in medical digital radiographic images.

A Study on the Exposure Parameter and the Patient Dose for Digital Radiography System in Dae Goo (디지털 방사선의학에서의 조사선량 설정과 인지에 대한 실태 - 대구 경북지역을 중심으로 -)

  • Jo, Gwang-Ho;Kang, Yeong-Han;Kim, Bu-Sun
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.177-182
    • /
    • 2008
  • Digital imaging for general rediography has many advantages over the film/screen systems, including a wider dynamic range and the ability to manipulate the images produced. The wider range means that acceptable images may by acquired at a range of dose levels, and therefore repeat exposures can be reduced. Digital imaging can result in the over use of radiation, however, because there is a tendency can be reduced. Digital imaging can result in the over use of radiation, however, because there is a tendency for images to be acquired at too high a dose. We investigated the actual exposure dose conditions on general radiography and a questionnaire survey was conducted with radiotechnologiest at medical institutions using digital radiology system. As a results, the dose of exposure was not controlled with patient's figure and dose optimization but was controlled by worker's convenience and image quality. Radio-technologiests often set up the exposure dose regardless of patient figure and body part to be examined. Many organizations, such as the International Commission on Radiological Protection, recommend to keep the dose as low as possible. In addition, they strongly recommend to keep the optimal but minimal dosage by proper training programs and constant quality control, including frequent patient dose evaluations and education.

  • PDF

Structural Relationship for Recognition of Radiation Risks on Management and Benefits of the University Students (대학생들의 방사선 위험 인식이 관리와 편익에 미치는 구조적 관계)

  • Seoung, Youl-Hun;Kim, Sung-Soo
    • Journal of Digital Convergence
    • /
    • v.12 no.2
    • /
    • pp.431-437
    • /
    • 2014
  • The purpose of this study was to perform an actual proof analysis on the structural effects of recognition of radiation risks on management and benefits. Data was collected using self-administered questionnaires targeting students having majors related to radiation from 1 April to 31 May in 2013 of one four-year-course university located in Chungbuk, Korea. As a result of the analysis, it turned out that as recognition of radiation risks is higher, recognition of radiation management is higher, which has a significant effect on benefits. It was indicated that although recognition of radiation risks does not directly influence radiation benefits, positive recognition on radiation benefits could increase through the parameter, radiation management. In order to improve smooth use of radiation and increase benefits, education that emphasizes the need of proper radiation management should be performed.

Study on Usefulness of Entrance Surface Dose (ESD), Entropy Analysis Method to Evaluate Ionization Chamber Performance and Implementation of Optimal Chamber Combination Model when using Automatic Exposure Control (AEC) Device in Digital Radiography (DR) (디지털 방사선 시스템(DR)의 자동노출제어장치 이용 시 이온 챔버의 성능 평가를 위한 엔트로피 분석법의 유용성과 최적의 챔버 조합 모델 구현 연구)

  • Hwang, Jun-Ho;Choi, Ji-An;Lee, Kyung-Bae
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.375-383
    • /
    • 2020
  • This study aimed to propose a methodology for quantitatively analyzing problems resulting from the performance and combination of the ionization chamber when using an automatic exposure control (AEC) and to optimize the performance of the digital radiography (DR). In the experimental method, the X-ray quality of the parameters used for the examination of the abdomen and pelvis was evaluated by percentage average error (PAE) and half value layer (HVL). Then, the stability of the radiation output and the image quality were analyzed by calculating the entrance surface dose (ESD) and entropy when the three ionization chambers were combined. As a result, all of the X-ray quality of the digital radiography used in the experiment showed a percentage average error and a half value layer in the normal range. The entrance surface dose increased in proportion to the combination of chambers, and entropy increased in proportion to the combination of ionization chambers except when three chambers were combined. In conclusion, analysis using entrance surface dose and entropy was found to be a useful method for evaluating the performance and combination problems of the ionization chamber, and the optimal performance of the digital radiography can be maintained when two or less ionization chambers are combined.

Quantitative Analysis of Digital Radiography Pixel Values to absorbed Energy of Detector based on the X-Ray Energy Spectrum Model (X선 스펙트럼 모델을 이용한 DR 화소값과 디텍터 흡수에너지의 관계에 대한 정량적 분석)

  • Kim Do-Il;Kim Sung-Hyun;Ho Dong-Su;Choe Bo-young;Suh Tae-Suk;Lee Jae-Mun;Lee Hyoung-Koo
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.202-209
    • /
    • 2004
  • Flat panel based digital radiography (DR) systems have recently become useful and important in the field of diagnostic radiology. For DRs with amorphous silicon photosensors, CsI(TI) is normally used as the scintillator, which produces visible light corresponding to the absorbed radiation energy. The visible light photons are converted into electric signal in the amorphous silicon photodiodes which constitute a two dimensional array. In order to produce good quality images, detailed behaviors of DR detectors to radiation must be studied. The relationship between air exposure and the DR outputs has been investigated in many studies. But this relationship was investigated under the condition of the fixed tube voltage. In this study, we investigated the relationship between the DR outputs and X-ray in terms of the absorbed energy in the detector rather than the air exposure using SPEC-l8, an X-ray energy spectrum model. Measured exposure was compared with calculated exposure for obtaining the inherent filtration that is a important input variable of SPEC-l8. The absorbed energy in the detector was calculated using algorithm of calculating the absorbed energy in the material and pixel values of real images under various conditions was obtained. The characteristic curve was obtained using the relationship of two parameter and the results were verified using phantoms made of water and aluminum. The pixel values of the phantom image were estimated and compared with the characteristic curve under various conditions. It was found that the relationship between the DR outputs and the absorbed energy in the detector was almost linear. In a experiment using the phantoms, the estimated pixel values agreed with the characteristic curve, although the effect of scattered photons introduced some errors. However, effect of a scattered X-ray must be studied because it was not included in the calculation algorithm. The result of this study can provide useful information about a pre-processing of digital radiography.

  • PDF

Development of $14"{\times}8.5"$ active matrix flat-panel digital x-ray detector system and Imaging performance (평판 디지털 X-ray 검출기의 개발과 성능 평가에 관한 연구)

  • Park, Ji-Koon;Choi, Jang-Yong;Kang, Sang-Sik;Lee, Dong-Gil;Seok, Dae-Woo;Nam, Sang Hee
    • Journal of radiological science and technology
    • /
    • v.26 no.4
    • /
    • pp.39-46
    • /
    • 2003
  • Digital radiographic systems based on solid-state detectors, commonly referred to as flat-panel detectors, are gaining popularity in clinical practice. Large area, flat panel solid state detectors are being investigated for digital radiography. The purpose of this work was to evaluate the active matrix flat panel digital x-ray detectors in terms of their modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). In this paper, development and evaluation of a selenium-based flat-panel digital x-ray detector are described. The prototype detector has a pixel pitch of $139\;{\mu}m$ and a total active imaging area of $14{\times}8.5\;inch^2$, giving a total 3.9 million pixels. This detector include a x-ray imaging layer of amorphous selenium as a photoconductor which is evaporated in vacuum state on a TFT flat panel, to make signals in proportion to incident x-ray. The film thickness was about $500\;{\mu}m$. To evaluate the imaging performance of the digital radiography(DR) system developed in our group, sensitivity, linearity, the modulation transfer function(MTF), noise power spectrum (NPS) and detective quantum efficiency(DQE) of detector was measured. The measured sensitivity was $4.16{\times}10^6\;ehp/pixel{\cdot}mR$ at the bias field of $10\;V/{\mu}m$ : The beam condition was 41.9\;KeV. Measured MTF at 2.5\;lp/mm was 52%, and the DQE at 1.5\;lp/mm was 75%. And the excellent linearity was showed where the coefficient of determination ($r^2$) is 0.9693.

  • PDF