• Title/Summary/Keyword: 디지털 감산 혈관조영술

Search Result 16, Processing Time 0.038 seconds

A Study on Non-Subtraction and Subtraction Technique in 3-Dimensional Angiography of the Cerebral Aneurysm (뇌동맥자루 3차원 혈관조영술에서 비감산 및 감산 기법에 관한 연구)

  • Kim, Kyung-Wan;Im, In-Chul;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.511-518
    • /
    • 2018
  • The purpose of this study was to measured the diameter, maximum diameter, maximum area and volume of the cerebral aneurysm in 53 patients who underwent three-dimensional digital angiography and three-dimensional digital subtraction angiography, which were used for the clinical diagnosis of cerebral aneurysm, image noise and radiation exposure dose of each test method were analyzed to compare clinical diagnosis differences in the cerebral aneurysm diagnosis. Three-dimensional digital angiography and three-dimensional digital subtraction angiography showed that the neck diameter, maximum diameter, maximum area, volume, and noise of the cerebral aneurysm were identical or very small. However, the three-dimensional digital angiography significantly decreased the radiation exposure dose compared to three-dimensional digital subtraction angiography. Therefore, in case of clinical diagnosis of cerebral aneurysm, three-dimensional digital angiography should be preferentially used to reduce radiation exposure dose of patient.

The Comparison of Usefulness between MDCT Angiography and DSA in the Diagnosis of Intracranial Aneurysm (뇌 동맥류 진단에 있어 디지털 감산 혈관조영술과 다중검출기 전산화단층촬영 혈관조영술의 유용성 비교)

  • Khang, Hyun-Soo;Seo, Sun-Youl;Han, Dong-Kyoon;Kwon, Soo-Il;Shim, Su-Jung;Cho, Sam-Ju
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.184-189
    • /
    • 2011
  • The purpose of this study was to compare the image between DSA and MDCT Angiography and to examine whether MDCT Angiography could be useful as a screening test for the diagnosis of cerebral aneurysm in patients who were diagnosed with cerebral aneurysm on DSA. Of patients who were diagnosed with cerebral aneurysm DSA at University Hospital, 194 patients who concomitantly underwent MDCT Angiography were enrolled in the current retrospective study. The methods for analyzing cerebral aneurysm were to analyze the presence of cerebral aneurysm on DSA and MDCT Angiography. In cases in which it exceeded 1, the corresponding cases were classified as narrow-neck aneurysms. In otherwise cases, they were classified as wide-neck aneurysms. Thus, a comparative analysis could be performed to ascertain if cases were narrow-neck or wide-neck aneurysms. As compared with DSA, the sensitivity of MDCT Angiography for cerebral aneurysm was measured to be 97.4%. The degree of consistency between narrow-neck and wide-neck aneurysms was 90.2% and the proportion of undetectable an at MDCT Angiography was 2.54%. mean size was 2.4 mm. It is expected that a non-invasive diagnostic modality for a screening test for cerebral aneurysm, MDCT Angiography might be a very useful regimen as compared with an invasive one, DSA.

Comparative Evaluation of North American Symptomatic Carotid Endarterectomy Trial and Warfarin-Aspirin Symptomatic Intracranial Disease Methods for Measurement of Middle Cerebral Artery Stenosis in Digital Subtraction Angiography and Magnetic Resonance Angiography (디지털 감산 혈관조영술과 자기 공명 혈관조영술에서 중대뇌동맥의 협착 측정을 위한 North American Symptomatic Carotid Endarterectomy Trial 및 Warfarin-Aspirin Symptomatic Intracranial Disease 방법의 비교 평가)

  • Lee, Jung-Hoon;Kim, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.42 no.5
    • /
    • pp.351-356
    • /
    • 2019
  • This study aimed to determine whether there was a difference in measurements between North American Symptomatic Carotid Endarterectomy Trial(NASCET) and Warfarin-Aspirin Symptomatic Intracranial Disease(WASID) methods that measure the middle cerebral artery stenosis in Digital Subtraction Angiography (DSA) and Magnetic Resonance Angiography (MRA). It involved 24 patients who had completed both DSA and MRA among patients with Middle Cerebral Artery (MCA) stenosis. The Middle Cerebral Artery (MCA) stenosis was measured using the NASCET and WASID methods through a retrospective analysis. For the NASCET and WASID methods, they performed measurements on normal blood vessels located far from and close to the stenosis, respectively. The mean value and standard deviation of the Digital Subtraction Angiography (DSA) measured by the NASCET method were 59.23% and 13.27%. On the other hand, those of the Digital Subtraction Angiography (DSA) measured by the WASID method were 66.64% and 12.47%. And, the mean value and standard deviation of the Magnetic Resonance Angiography (MRA) measured by the NASCET method were 49.82% and 12.06%. By contrast, those of the Magnetic Resonance Angiography (MRA) measured by the WASID method were 56.63% and 10.67%. All the p-values obtained by the Pearson and Spearman correlation tests in the Digital Subtraction Angiography (DSA) and the Magnetic Resonance Angiography (MRA) were <0.01. In conclusion, this study suggests that both the NASCET and WASID methods to measure the middle cerebral artery stenosis in the Digital Subtraction Angiography (DSA) and the Magnetic Resonance Angiography (MRA) can be used if they are not used interchangeably.

삼차원 조영증강 자기공명혈관조영술을 이용한 내경동맥 협착에 대한 평가: 디지털감산혈관조영술과의 비교

  • 한동복;최충곤;박지강;이정현;이호규
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.139-139
    • /
    • 2001
  • 목적: 경동맥 분지부에서 내경동맥 협착에 대한 평가에 있어서 삼차원 조영증강 자기공명혈관조영술의 정확도를 알아보고자 하였다. 대상 및 방법: 삼차원 조영증강 자기공명혈관조영술(3D Contrast-enhanced MRA)과 디지털감산혈관 조영술(Digital Subtraction Angiography, DSA)을 모두 시행한 35명의 환자, 68예의 내경동맥을 분석하였다. 내경동맥 협착의 측정은 North American Symptomatic Carotid Endarterectom Trial (NASCET) 기준을 이용하였다. 두 가지 검사에서 협착 정도를 경도(mild:0-29%), 중등도(moderate:30-69%), 심한 협착(severe:70-99%), 완전 폐색(occlusion:100%)등 네 그룹으로 나누었다. 두 명의 관찰자(A,B)가 DSA에서 측정한 협착 정도를 기준으로 3D Contrast-enhanced MRA에서 측정한 협착 정도를 비교하여 두 검사 방법간에 판정 일치율과 차이점을 분석하였다.

  • PDF

Borden Type I Sigmoid Sinus Dural Arteriovenous Fistula Presenting as Subarachnoid Hemorrhage from a Feeding Artery Aneurysm of the Anterior Inferior Cerebellar Artery: A Case Report (Borden I 유형의 S상 정맥동 경막 동정맥루의 공급 동맥인 전방 하뇌 소뇌 동맥의 동맥류 파열로 인한 지주막하 출혈: 증례 보고)

  • Myojeong Kim;Sung-Tae Park
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.6
    • /
    • pp.1472-1477
    • /
    • 2020
  • Dural arteriovenous fistula is an acquired vascular anomaly that can cause various symptoms. Here, we report a rare case of Borden type I sigmoid sinus dural arteriovenous fistula presenting as subarachnoid hemorrhage. Bleeding occurred from a side-wall aneurysm in the lateral pontomedullary segment of the anterior inferior cerebellar artery, which was a minor pial feeder. Features on imaging modalities, including brain CT, CT angiography, MR imaging/angiography and digital subtraction angiography, are described with a literature review.

A Case Report of Pontine Infarction as an Initial Manifestation of Systemic Lupus Erythematosus: Diagnostic Clues from MRI and Digital Subtraction Angiography (전신성 홍반성 루푸스의 초기 증상으로 나타난 교뇌경색의 증례 보고: 자기공명영상 및 디지털감산 혈관조영술에서의 진단 단서)

  • Mi Sun Chung;Jun Soo Byun;Younghee Yim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.5
    • /
    • pp.1281-1286
    • /
    • 2021
  • Brainstem infarction due to vertebrobasilar insufficiency is a rare initial presentation of systemic lupus erythematosus (SLE) patients and small-vessel dissection as the direct cause of infarction has not been reported. We report the case of a 20-year-old female with acute infarction on the right side of the pons due to a small artery (pontine perforator) dissection, identified on digital subtraction angiography and high-resolution vessel wall MRI (vwMRI). She was diagnosed with SLE based on the presence of neurologic disorders and relevant laboratory findings. The pontine perforator-dissecting aneurysm had occluded and the right distal vertebral artery had resolved on subsequent vwMRI. She had a modified Rankin Scale (mRS) score of 1 at discharge with mild symptom improvement, and exhibited no further aggravation of symptoms at 3 or 12 months, maintaining an mRS score of 1.

Persistent Trigeminal Artery Variant Terminating in the Ipsilateral Superior Cerebellar Artery (상소뇌동맥영역을 공급하는 지속성 원시 삼차신경동맥 변이)

  • Tae Young Park;Byung Hoon Lee;Yoon Joon Hwang;Ji Young Lee;Suk Hyun Bae
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.1
    • /
    • pp.184-188
    • /
    • 2022
  • Persistent trigeminal artery (PTA) represent an unusual remnant of the fetal carotid-basilar anastomosis. Persistent trigeminal artery variant (PTAV) is a rare anastomosis between the internal carotid artery and cerebellar artery, without an interposing basilar artery segment. We report the case of 49-year-old female with an incidentally discovered, rare variation of PTA that directly terminated in the ipsilateral superior cerebellar artery. The variation was observed on CT angiography, digital subtraction angiography, and MR angiography. Additionally, we reviewed the embryogenesis of PTA and PTAV and discussed the clinical implications of this variation.

Contrast-Enhanced Magnetic Resonance Angiography for Evaluation of the Steno-occlusive Disease of the Supraaortic Arteries: Comparison with Computed Tomography Angiography and Digital Subtraction Angiography (조영증강 자기공명 혈관조영술을 이용한 대동맥궁 위 혈관의 협착 및 페쇄 질환 평가: 전산화 단층 혈관조영술 및 디지털 감산혈관조영술과의 비교)

  • Jeh, Su-Kyung;Kim, Bum-Soo;Jung, So-Lyung;Ahn, Kook-Jin;Shin, Yong-Sam;Lee, Kwan-Sung;Kim, Young-In;Lee, Kwang-Soo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.2
    • /
    • pp.152-160
    • /
    • 2009
  • Purpose : To intra-individually compare diagnostic accuracy of high-resolution contrast-enhanced magnetic resonance angiography (CE-MRA) with computed tomography angiography (CTA) and digital subtraction angiography (DSA) for the assessment of supraaortic steno-occlusive disease. Materials and Methods : Twenty-eight patients (20 men, 8 women, 53-79 years of age) underwent supraaortic CE-MRA, CTA and DSA. CE-MRA was performed on two 1.5T MR scanners (voxel dimension: $0.66{\times}0.66{\times}1.1$ or $1.2\;mm^3$), and CTA on 64-slice CT scanners (voxel dimension: $0.42{\times}0.42{\times}0.63\;mm^3$). All the three examinations were completed within 40 days (median 19 days; range 1-40 days). Retrospective evaluation and measurement of diameter of 6 extracranial and 9 intracranial arterial segments was done by 2 experienced radiologists. Results: A total of 420 arterial segments were examined by CE-MRA, CTA and DSA. On DSA, 34 stenoocclusive lesions were noted at extracranial (n= 19) and intracranial (n = 15) vessels. For extracranial stenosis greater than 70%, sensitivity, specificity, positive predictive value (PPV) and negative predictive values (NPV) were 94.7%, 98.7%, 90.0% and 99.3% on CE-MRA, and 94.7%, 99.3%, 94.7% and 99.3% on CTA. For intracranial stenosis greater than 50%, sensitivity; specificity, PPV and NPV were 93.3%, 98.3%, 77.8%and 99.6% on CE-MRA, and 86.7%, 97.9%, 72.2% and 99.1 % on CTA, with DSA as the standard of reference. Conclusion : Supraaortic CE-MRA is as reliable as CTA in depicting the arterial stenosis, and is effective in screening of significant stenosis of both extracranial and intracranial arterial stenosis.

  • PDF

Three-Dimensional Digital Subtraction Angiography (디지털 혈관 조영술 영상의 3차원적 해석)

  • 이승지;김희찬
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.20 no.1
    • /
    • pp.63-71
    • /
    • 1983
  • A dye-edge tracking algorithm was used to determine the corresponding points in the two images(anterior-posterior and lateral) of the digital subtraction biplane angiography. This correspondence was used to reconstruct three dimensional images of cerebral artery in a dog experiment. The method was tested by comparing the measured image of oblique view with the computed reconstructed image. For the present study, we have developed three new algorithms. The first algorithm is to determine the corresponding dye-edge points using the fact the dye density at the moving edge avows the same changing pattern in the two projection views. This moving pattern of dye-edge density is computed using a matching method of cross-correlation for the two sequential frames' dye density. The second algorithm is for simplified perspective transformation, and the third one is to identify the specific corresponding points on the small vessels. The present method can be applied to compute the blood velocity using the dye-edge displacement and the three- dimensional distance data.

  • PDF

New Carotid Artery Stenosis Measurement Method Using MRA Images (경동맥 MRA 영상을 이용한 새로운 내경 측정 방법)

  • 김도연;박종원
    • Journal of KIISE:Software and Applications
    • /
    • v.30 no.12
    • /
    • pp.1247-1254
    • /
    • 2003
  • Currently. the north american symptomatic carotid endarterectomy trial, european carotid surgery trial, and common carotid method are used to measure the carotid stenosis for determining candidate for carotid endarterectomy using the projection angiography from different modalities such as digital subtraction angiography. rotational angiography, computed tomography angiography and magnetic resonance angiography. A new computerized carotid stenosis measuring system was developed using MR angiography axial image to overcome the drawbacks of conventional carotid stenosis measuring methods, to reduce the variability of inter-observer and intra-observer. The gray-level thresholding is one of the most popular and efficient method for image segmentation. We segmented the carotid artery and lumen from three-dimensional time-of-flight MRA axial image using gray-level thresholding technique. Using the measured intima-media thickness value of common carotid artery for each cases, we separated carotid artery wall from the segmented carotid artery region. After that, the regions of segmented carotid without artery wall were divided into region of blood flow and plaque. The calculation of carotid stenosis degree was performed as the following; carotid stenosis grading is(area measure of plaque/area measure of blood flow region and plaque) * 100%.