• Title/Summary/Keyword: 두경부 암

Search Result 606, Processing Time 0.027 seconds

Survival Value of Myocutaneous Flaps in the Management of Epidermoid Carcioma of the Oral Cavity (구강내 상피암의 치료에서 근피부판이 생존율에 미치는 영향)

  • Seel David John;Park Chul-Young;Yoo Chung-Joon;Lee Samuel;Park Yoon-Kyu
    • Korean Journal of Head & Neck Oncology
    • /
    • v.6 no.2
    • /
    • pp.79-84
    • /
    • 1990
  • This paper is a review of our experience with radical resection for cancer of the oral cavity with particular emphasis upon the value of myocutaneous(i.e., musculocutanous) flaps employed in the surgical reconstruction in patient survival. During the past 15 years, 98 patients underwent resection of cancer arising in the oral cavity and oropharynx. Of these, 14 had composite resections in which the mandible was not sectioned, and 4 underwent en bloc resections without neck dissections in the face of post-radiation recurrence. When these excluded, 84 patients who underwent COMMANDO procedures with or without myocutaneous flaps were suitable for analysis of recurrence and survival according to the various surgical technics employed. 1) According to the surgical technic, there were 24 standard COMMANDO procedures in whom no regional or myocutanous flap was used; 12 patients who underwent reconstruction employing a forehead flap; 19 patients in whom a posterior cervical 'nape' flap was employed; 27 patients who underwent myocutaneous or osteo-myocutaneous flap repair; and two patients who had double flap repair. 2) The uncorrected two-year disease free survival was 41% for standard COMMANDOs, 17% for forehead flap COMMANDOs; 35% for nape flap COMMANDOs; and 35% for myocutaneous flap COMMANDO procedures. 3) The two-year disease-free survival by Stage was 100% in Stage I, 45% in Stage II, 41% in Stage III, and 18% in Stage IV. 4) When myocutanous flaps cases were compared with Group I, comprised of matched historical controls including both Standard COMMANDOs and those who had undergone regional flap repairs(that is, forehead and nape flap COMMANDOs)there was no difference, both groups showing a 40% 2-year disease-free survival. 5) When musculocutanous flap cases were compared with Goup II, which was composed of matched historical controis limited to patients who had undergone regional flap repairs(that is, forehead and nape flap cases only)there was no difference, both groups showing a 27% 2-year desease-free survival. 6) When musculocutanous flap cases were compared with Group III, composed of patients who had undergone classic COMMANDO procedures without any sort of flap repair, there was a striking difference; the patients undergoing MC flap repair showed 50% 2-year disease-free survival, whereas the classic COMMANDO cases showed a 25% survival free of disease. 7) Locoregional recurrence was also evaluated in the four categories; for standard COMMANDO cases it was 25%, for nape flap cases 26% ; for forehead flap cases, 33%, and for the musculocutaneous flap cases, the lowest recurrence rate, 22%. These results are of particular significance in view of the fact that the proportion of advanced cases(Stage III and IV)in each category was 67% of standard cases, 79% of nape flap patients, 100% of forehead flap cases, and 96% of musculocutaneous flap cases.

  • PDF

EGFR, p53, Cox-2 and Bcl-2 Expression in Nasopharyngeal Carcinoma and Their Potential Clinical Implication (비인강암에서 예후인자로서의 EGFR, p53, Cox-2, Bcl-2 단백발현)

  • Chae, Soo-Min;Lee, Youn-Soo;Roh, Kwang-Won;Chung, Su-Mi;Yoon, Sei-Chul;Jang, Hong-Seok;Kim, Yeon-Sil
    • Radiation Oncology Journal
    • /
    • v.25 no.1
    • /
    • pp.43-53
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: To evaluate the relationship between the expression of EGFR, p53, Cox-2, Bcl-2 and the clinical parameters of NPC (nasopharyngeal carcinoma) patients treated with radiotherapy with/without chemotherapy, and to determine if these could be used as a biologic marker. $\underline{Materials\;and\;Methods}$: This study retrospectively examined 75 NPC patients who were pathologically diagnosed at St. Mary's Hospital and Kangnam St Mary's Hospital from March 1988 to August 2002 and treated with radiotherapy with/without chemotherapy. The levels of EGFR, p53, Cox-2, and Bcl-2 expression were determined immunohistochemically. The relationship between the levels of EGFR, p53, Cox-2 and Bcl-2 expression and the H- E staining findings including the WHO classification, TNM stage, tumor response to chemotherapy and radiotherapy, disease free survival (DFS), and overall survival (OS) was analyzed. $\underline{Results}$: At a median follow up of 50.8 months (range: $5.5{\sim}201$ months), the 3 years OS rate and PFS rate were 68.7% and 68.2%, respectively. The five year OS rate and PFS rate were 53.5% and 51.1%, respectively. The median OS duration and PFS duration were 85.5 months and 61.1 months, respectively. The WHO classification correlated with the complete response rate, lymph node metastasis and distant metastasis. The expression of p53 was associated with increased mitosis and poor overall survival. The expression of Bcl-2 correlated with the DFS and WHO classification. The expression of Cox-2 correlated with a poor overall survival and response rate in the lymph node. However, EGFR was not correlated with any factors. $\underline{Conclusion}$: These results suggest that the expression of p53, Cox-2, Bcl-2 plays role in predicting prognostic factors for NPC treated with radiotherapy with/without chemotherapy. However, further study on a larger number of patients will be needed to identify more useful biomarkers of NPC.

Pilot Study for the Prediction of Response to Radiotherapy Using [$^{18}F$]Fluorothymidine PET in Nasopharyngeal Cancer: Comparison with [$^{18}F$]FDG PET (비인두암에서 [$^{18}F$]Fluorothymidine PET을 이용한 방사선치료 반응도 예측을 위한 예비 연구: [$^{18}F$]FDG PET와의 비교)

  • Baek, So-Ra;Chae, Sun-Young;Kim, Hye-Ok;Lee, sang-Wook;Oh, Seung-Jun;Im, Ki-Chun;Moon, Dae-Hyuk;Kim, Jae-Seung;Ryu, Jin-Sook
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.6
    • /
    • pp.535-542
    • /
    • 2009
  • Purpose: This study was performed to know whether [$^{18}F$]Fluorothymidine (FLT) positron emission tomography (PET) can be used to monitor early response to radiotherapy in comparison with [$^{18}F$]Fluorodeoxyglucose (FDG) PET, and to establish the optimal imaging time for prediction of therapy response. Materials and Methods: Two patients with nasopharyngeal cancer underwent serial FLT PET and FDG PET before and during radiotherapy. Three on-treatment FLT and FDG PET scans were performed on 1 week, 2 weeks and 3 weeks (at each time of 10 Gy, 20 Gy and 30 Gy delivered). The peak standardized uptake values ($SUV_{peak}$) of primary tumors were measured on FLT and FDG PET. Then, percent changes of $SUV_{peak}$ after therapy were calculated. Results: In two patients, baseline values of $SUV_{peak}$ on FDT PET were higher than those on FLT PET (FLT vs FDG; 3.7 vs 5.0, and 5.7 vs 15.0). In patient 1, FLT $SUV_{peak}$ showed 78%, 78% and 84% of decrease on 1 week, 2 and 3 weeks after treatment, whereas FDG $SUV_{peak}$ showed 18%, 52% and 66% of decrease, respectively. In patient 2, FLT $SUV_{peak}$ showed 75%, 75% and 68% of decrease, whereas FDG $SUV_{peak}$ showed 51%, 49% and 58% of decrease, respectively. Both patients reached to complete remission after radiotherapy. Conclusion: After radiotherapy, the decrease of FLT tumor uptake preceded the decrease of FDG tumor uptake in patients with nasopharyngeal cancer, and 1 week after therapy may be appropriate time for the assessment of early response. FLT PET might be more useful than FDG PET for monitoring early response to radiotherapy.

Evaluation of Setup Uncertainty on the CTV Dose and Setup Margin Using Monte Carlo Simulation (몬테칼로 전산모사를 이용한 셋업오차가 임상표적체적에 전달되는 선량과 셋업마진에 대하여 미치는 영향 평가)

  • Cho, Il-Sung;Kwark, Jung-Won;Cho, Byung-Chul;Kim, Jong-Hoon;Ahn, Seung-Do;Park, Sung-Ho
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.81-90
    • /
    • 2012
  • The effect of setup uncertainties on CTV dose and the correlation between setup uncertainties and setup margin were evaluated by Monte Carlo based numerical simulation. Patient specific information of IMRT treatment plan for rectal cancer designed on the VARIAN Eclipse planning system was utilized for the Monte Carlo simulation program including the planned dose distribution and tumor volume information of a rectal cancer patient. The simulation program was developed for the purpose of the study on Linux environment using open source packages, GNU C++ and ROOT data analysis framework. All misalignments of patient setup were assumed to follow the central limit theorem. Thus systematic and random errors were generated according to the gaussian statistics with a given standard deviation as simulation input parameter. After the setup error simulations, the change of dose in CTV volume was analyzed with the simulation result. In order to verify the conventional margin recipe, the correlation between setup error and setup margin was compared with the margin formula developed on three dimensional conformal radiation therapy. The simulation was performed total 2,000 times for each simulation input of systematic and random errors independently. The size of standard deviation for generating patient setup errors was changed from 1 mm to 10 mm with 1 mm step. In case for the systematic error the minimum dose on CTV $D_{min}^{stat{\cdot}}$ was decreased from 100.4 to 72.50% and the mean dose $\bar{D}_{syst{\cdot}}$ was decreased from 100.45% to 97.88%. However the standard deviation of dose distribution in CTV volume was increased from 0.02% to 3.33%. The effect of random error gave the same result of a reduction of mean and minimum dose to CTV volume. It was found that the minimum dose on CTV volume $D_{min}^{rand{\cdot}}$ was reduced from 100.45% to 94.80% and the mean dose to CTV $\bar{D}_{rand{\cdot}}$ was decreased from 100.46% to 97.87%. Like systematic error, the standard deviation of CTV dose ${\Delta}D_{rand}$ was increased from 0.01% to 0.63%. After calculating a size of margin for each systematic and random error the "population ratio" was introduced and applied to verify margin recipe. It was found that the conventional margin formula satisfy margin object on IMRT treatment for rectal cancer. It is considered that the developed Monte-carlo based simulation program might be useful to study for patient setup error and dose coverage in CTV volume due to variations of margin size and setup error.

Radiosensitization of Cis-Platimum in the Treatment of Advanced Head and Neck Squamous Cell Carcinoma (국소 진행된 두경부편평 상피암에 대한 CIS-PLATINUM과 방사선치료의 동시 병행요법)

  • Chang, Hye-Sook
    • Radiation Oncology Journal
    • /
    • v.10 no.1
    • /
    • pp.27-34
    • /
    • 1992
  • Cis-Platinum (DDP) was utilized as a radiosensitizer in a pilot study for stage III and IV squamous cell carcinoma between 1984-1987, and DDP 20 $mg/M^2$/day was administered for 4 days at 3 week interval with concurrent radiotherapy. This study consisted of three phases: cytoreduction phase, eradicative treatment phase and adjuvant phase. Total 59 patients were subjected to evaluate a tumor response and its toxicity. During the eradicative phase,27 patients underwent surgery (group I ), 29 patients were treated with radiotherapy only (group II) and 3 patients did not complete the second phase of therapy. At the cytoreduction phase, $95\%$ response rate with complete response (CR) $47.5\%$ and partial response (PR) $47.5\%$ was observed. Complete tumor clearance (CTC) rate following 2nd phase of therapy was $84\%$ (47/56) with 26/27($96\%$) in group I achieved CTC with surgery and 21/29 ($72\%$) patients In group II achieved CTC following 2nd phase. $67\%$ of primary lesions and $70\%$ of nodal diseases in group I showed no tumor in the surgical specimen. $34\%$ of patiets who achieved CTC at 2nd phase developed recurrence and median time to recur was 8 months. Actuarial disease free survival at 4 years was $59\%$ and $51\%$(24/27) of patients who achieved CTC at 2nd phase were alive without any evidence of disease at median follow-up 31 months (range, 10-48 months). There was no significant difference in overall and disease free survival between group I and II between CR and PR group following 1st Phase. Only significant Prognostic factor in this study was the complete tumor clearance following 2nd phase theapy. In general, toxicity was not excessive. Author concludes that this study confirmed the significant radiosensitizing effect of DDP with the acceptable toxicity and warrant the prospective study to determine optimum scheduling for DDP and radiotherapy which maximizes the therapeutic gain.

  • PDF

Geometric Calibration of Cone-beam CT System for Image Guided Proton Therapy (영상유도 양성자치료를 위한 콘빔 CT 재구성 알고리즘: 기하학적 보정방법에 관한 연구)

  • Kim, Jin-Sung;Cho, Min-Kook;Cho, Young-Bin;Youn, Han-Bean;Kim, Ho-Kyung;Yoon, Myoung-Geun;Shin, Dong-Ho;Lee, Se-Byeung;Lee, Re-Na;Park, Sung-Yong;Cho, Kwan-Ho
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.209-218
    • /
    • 2008
  • According to improved radiation therapy technology such as IMRT and proton therapy, the accuracy of patient alignment system is more emphasized and IGRT is dominated research field in radiation oncology. We proposed to study the feasibility of cone-beam CT system using simple x-ray imaging systems for image guided proton therapy at National Cancer Center. 180 projection views ($2,304{\times}3,200$, 14 bit with 127 ${\mu}m$ pixel pitch) for the geometrical calibration phantom and humanoid phantoms (skull, abdomen) were acquired with $2^{\circ}$ step angle using x-ray imaging system of proton therapy gantry room ($360^{\circ}$ for 1 rotation). The geometrical calibration was performed for misalignments between the x-ray source and the flat-panel detector, such as distances and slanted angle using available algorithm. With the geometrically calibrated projection view, Feldkamp cone-beam algorithm using Ram-Lak filter was implemented for CBCT reconstruction images for skull and abdomen phantom. The distance from x-ray source to the gantry isocenter, the distance from the flat panel to the isocenter were calculated as 1,517.5 mm, 591.12 mm and the rotated angle of flat panel detector around x-ray beam axis was considered as $0.25^{\circ}$. It was observed that the blurring artifacts, originated from the rotation of the detector, in the reconstructed toomographs were significantly reduced after the geometrical calibration. The demonstrated CBCT images for the skull and abdomen phantoms are very promising. We performed the geometrical calibration of the large gantry rotation system with simple x-ray imaging devices for CBCT reconstruction. The CBCT system for proton therapy will be used as a main patient alignment system for image guided proton therapy.

  • PDF

DEVELOPMENTAL DISTURBANCE OF PERMANENT TEETH AFTER RADIOTHERAPY FOR TREATMENT OF MALIGNANT TUMOR : REPORT OF CASES (소아암 환자에서 방사선 치료 후 영구치 치근발육장애 : 증례보고)

  • Heo, Su-Kyung;Choi, Nam-Ki;Kim, Seon-Mi;Yang, Kyu-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.1
    • /
    • pp.144-150
    • /
    • 2008
  • Multimodal cancer therapy including surgery, chemotherapy, and radiotherapy could not only improve the prognosis of malignancy but also reduce the dosage and toxicity of cancer drug for treatment of malignant tumor. The effects of radiotherapy are generally localized, additive, and accumulative, and depend on dosage, site and cell sensitivity. However, in growing individuals, the dental and skeletal sequelae to radiotherapy result in dental or facial abnormalities that are irreversible : arrested root development, disturbances in enamel formation, microdontia, anodontia, altered tooth eruption and mandibular or maxillary hypoplasia. Especially, the teeth which are developing is affected according to the stage. We report three cases of developmental disturbance of permanent teeth after radiotherapy. These children had received radiotherapy for malignant tumor at the age of 3 to 4 years, in which root hypoplasia, short tapered root and early apex closure were observed. For the management of radiation caries and radiotherapy-related teeth, periodic recall check and oral hygiene instruction are required.

  • PDF

A Study of Relationship Between PPC (Probability of Primary Clearance: a multivariate modelling system predicting tumor clearance proposed by RTOG) and Survival in the Patients with Carcinoma of the Nasopharynx following Radiation Therapy (비인강암의 방사선치료 : RTOG에서 제시한 PPC와 생존율에 대한 고찰)

  • Cho Kwan Ho;Park Kyung Ran;Oh Won Yong;Chun Mison;Suh Chang Ok;Kim Gwi Eon;Loh John J.K.
    • Radiation Oncology Journal
    • /
    • v.4 no.1
    • /
    • pp.45-50
    • /
    • 1986
  • RTOG proposed a multivariate modelling system predicting the response of head and neck cancers to radiation therapy in 1984. The aim of this study was to veri(y whether PPC (Probaility of primary clearance calculated by a multivariate modelling system) had any correlation with the survival in the patients with carcinoma of the nasopharynx following radiation therapy Analysing 81 patients with carcinoma of the nasopharynx treated with radiotherapy between January 1, 1971 and December 31, 1983 at Yonsei University College of Medicine, Yonsei Cancer Center the actuarial 5 year survival rate was $36\%$ and median survival was 39 months. The survivals for Group 1 (27 who had more than $80\%$ of PPC), Group 2 (20 who had between 71 and $80\%$ of PPC), and Group 3 (29 who had less than $71\%$ of PPC) were $66\%$ (median survival months : more than 72), $27\%$ (31), and $4\%$ (12) respectively. There was a definite correlation between PPC and survival among the three groups.

  • PDF

A Preliminary Study of Virtual-micro Intensity Modulated Radiation Therapy (가상 미세 세기조절방사선치료(Virtual micro-IMRT;VMIMRT) 기법의 임상 적용을 위한 예비적 연구)

  • 김상노;조병철;서택석;배훈식;최보영;이형구
    • Progress in Medical Physics
    • /
    • v.13 no.1
    • /
    • pp.32-36
    • /
    • 2002
  • For Intensity Modulated Radiation Therapy(IMRT), the spatial resolution of intensity map(IM) is limited by the width of multi-leaf collimator, which would make an effect on the conformity of the target, as well as organs at risk. Several Methods are suggested to increase the spatial resolution, which can be categorized by the hardware-dependent technique and the software-based technique. However the best solution might be to make the width of MLC finer. it has several obstacles in the respects of technical difficulty and cost. This preliminary study is designed to investigate the clinical effectiveness of the virtual-micro IMRT(VMIMRT) technique, one of the software-based technique. A particular intensity map was created, which has 42$\times$54 pixel dimension ,0.5cm pixel size and 15 intensity levels. Using this intensity map, segment fields of IMRT were generated with 1$\times$lcm, 0.5$\times$1cm, 0.5$\times$0.5cm(VMIM) beamlet size, respectively As results, we found that there was no evidence of improvement for VMIMRT, compared with the 0.5$\times$lcm beamlet size which can be delivered by 1cm width MLC. The reason seems to be due to the constraint of VMIMRT. Further study is required to prove the benefit of the VIMRT in clinical case like head and neck cancer, where is expected that higher resolution than 1cm is necessary.

  • PDF

Discovering the Anti-cancer Effects of Ligusticum Chuanxiong through Network-based Pharmacology Analysis and Molecular Docking: An Inquiry into Natural Products (네트워크 기반 약리학 분석 및 분자 도킹을 통한 천궁의 항암 효과 예측: 천연물에 대한 탐구)

  • Do Kyung Han;Jee Won Shon;Eui Suk Sung;Youn Sook Kim;Won G. An
    • Journal of Life Science
    • /
    • v.33 no.11
    • /
    • pp.876-886
    • /
    • 2023
  • In some cases of head and neck cancers (HNC), surgical interventions may result in the loss of organs and/or changes to their functions, thereby significantly affecting the patient's quality of life. As a result, the surgical treatment of HNC patients is often limited to specific cases, and alternative treatment modalities, such as chemotherapy, are considered. However, serious adverse effects caused by chemotherapy, such as severe nausea and vomiting, necessitate the need for the development of adjunctive methods to minimize patient suffering. Chuanxiong, Ligusticum chuanxiong (L. chuanxiong), is a natural herb used in Eastern medicine to treat cerebrovascular disorders and headaches. This study aimed to predict the effect and potential of L. chuanxiong as an auxiliary anticancer drug through network-based pharmacology and molecular docking analysis. The study results showed that 40 out of 41 genes of L. chuanxiong shared common targets of HNC and their proteins could be used to target HNC cells to prevent cancer progression. The results of the functional enrichment analysis confirmed that L. chuanxiong is associated with the neuroactive-ligand metabolism and neurotransmitter pathways, indicating its potential medicinal value as an adjuvant in HNC treatment. Lastly, our findings demonstrated that the active ingredient of L. chuanxiong, (Z)-Ligustilide, has the ATP binding site of heat shock protein 90, a protein known to promote the activation of cancer cells. These results suggest that L. chuanxiong is a promising candidate for developing auxiliary anticancer drugs, and further research could potentially lead to the discovery of newer and safer anti-cancer agents.