• Title/Summary/Keyword: 동적 초음파

Search Result 108, Processing Time 0.02 seconds

The Correlations of Parameters Using Contrast Enhanced Ultrasonography in the Evaluation of Prostate Cancer Angiogenesis (전립선암쥐모형의 신생혈관생성의 평가를 위해 시행된 역동적 조영 증강 초음파에서 얻은 변수간의 상관성연구)

  • Hwang, Sung Il;Lee, Hak Jong;Kim, Kil Joong;Chung, Jin-haeng;Jung, Hyun Sook;Jeon, Jong June
    • Ultrasonography
    • /
    • v.32 no.2
    • /
    • pp.132-142
    • /
    • 2013
  • Purpose: The purpose of this study is to investigate the correlations of various kinetic parameters derived from the time intensity curve in a xenograft mouse model injected with a prostate cancer model (PC-3 and LNCaP) using an ultrasound contrast agent with histopathologic parameters. Materials and Methods: Twenty nude mice were injected with human prostate cancer cells (15 PC-3 and five LNCaP) on their hind limbs. A bolus of $500{\mu}L$ ($1{\times}10^8$ microbubbles) of second-generation US contrast agent (SonoVue) was injected into the retroorbital vein. The region of interest was drawn over the entire tumor. The time intensity curve was acquired and then fitted to a gamma variate function. The maximal intensity (A), time to peak (Tp), maximal wash-in rate (washin), washout rate (washout), area under the curve up to 50 sec ($AUC_{50}$), area under the ascending slope ($AUC_{in}$), and area under the descending slope ($AUC_{out}$) were derived from the parameters of the gamma variate fit. Immunohistochemical staining for VEGF and CD31 was performed. Tumor volume, the area percentage of VEGF stained in a field, and the count of CD31 (microvessel density, MVD) positive vessels showed correlation with the parameters from the time intensity curve. Results: No significant differences were observed between the kinetic and histopathological parameters from each group. MVD showed positive correlation with A (r=0.625, p=0.003), washin (r=0.462, p=0.040), $AUC_{50}$ (r=0.604, p=0.005), and $AUC_{out}$ (r=0.587, p=0.007). Positive correlations were also observed between tumor volume and $AUC_{50}$ (r=0.481, p=0.032), washin (r=0.662, p=0.001), and $AUC_{out}$ (r=0.547, p=0.012). Washout showed negative correlations with MVD (r=-0.454, p=0.044) and tumor volume (r=-0.464, p=0.039). The area percentage of VEGF did not show any correlation with calculated data from the curve. Conclusion: MVD showed correlations with several of the kinetic parameters. CEUS has the potential for prediction of tumor vascularity in a prostate cancer animal model.

Examination Techniques and Imaging Findings of Hepatic Hemangioma (간혈관종의 검사기법과 영상소견)

  • Chang-Hoe Koo;Jong-Wan Keum;Ji-Eun Seok;Dong-Chul Choi;Yun-Ho Choi;Man-Seok Han;Min-Cheol Jeon
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.375-384
    • /
    • 2023
  • Most Hepatic hemangiomas are asymptomatic and small in size, making them difficult to find by pathological examination. Therefore, radiological diagnosis is essential for the early finding and diagnosis of Hepatic hemangioma. Three-phase method using contrast medium in computed tomography, T1, T2-weighted imaging in magnetic resonance imaging, dynamic magnetic resonance imaging using contrast medium, echo planar imaging method, diffusion-weighted imaging method, blood pool scan using 99mTc-labeled red blood cells in nuclear medicine, we looked at the color doppler method In ultrasound, and it is important to accurately understand the imaging findings of hepatic hemangioma and perform the examination in order to make an accurate diagnosis. most hepatic hemangioma are benign tumors, care should be taken not to confuse them with malignant tumors such as hepatocellular carcinoma to prevent unnecessary procedures. Therefore, in order to make an accurate diagnosis, it is important to accurately understand the imaging findings of hemangioma and perform the examination.

The Design of a Hybrid Composite Strut Tower for Improving Impact Resistance and Light-weight (내충격성 향상 및 경량화를 위한 하이브리드 복합재료 스트럿 타워 설계)

  • Lee, Hyun Chul;Oh, Hyun Ju;Kim, Seong Su
    • Composites Research
    • /
    • v.26 no.4
    • /
    • pp.223-229
    • /
    • 2013
  • Hybrid composite strut tower was designed to prevent permanent deformation of upper mount by the impact from the uneven road. When exceeding energy absorption capacity of tire and suspension systems, residual impact is delivered to upper mount. Especially, in case of using high-rigidity suspension system for high driving performance, the conventional strut tower can be easily deformed due to reduction of energy absorption capacity of suspension systems. In this study, optimal design of hybrid composite strut tower which made of back-up metal and carbon fiber reinforced composite was suggested by using finite element analysis, and low velocity impact test was performed to investigate their dynamic characteristics. Also, 3D measuring and ultra c-scanning methods were carried out to diagnose damages in the strut towers.

Hammer Energy Level of SPT in Korea (표준관입시험의 해머에너지 수준)

  • 이호준;박용원
    • Geotechnical Engineering
    • /
    • v.12 no.5
    • /
    • pp.117-126
    • /
    • 1996
  • In spite of many advantages such as the simplicity in test procedure, Standard Penetration Test(SPT) results contain some errors caused by the variability of test equipment, instruments and test procedures. Especially, it is inevitable that the measured SPT hammer energy is different from the theoretical value because of energy loss. In this paper, the hammer energy level is measured during the performance of the field SPT in Korea by using a ultra-sonic system and PC.program. As the results of this study, the average hammer energy ratio of the R-P hammer and the Trip hammer is calculated at 64.2%, and at 75.0% respectively. The average energy ratio of the SPT for the R-P hammer is calculated at 46% and at 54% for the Trip hammer, by applying the rod energy ratio 0.72.

  • PDF

Differences of Physical, Mechanical and Chemical Properties of Korean Red Pine(Pinus densiflora) Between Old and New Wood (소나무 고목재와 건전재의 물리, 기계, 화학적 특성 차이)

  • Shim, Kug-Bo;Lee, Do-Sik;Park, Byung-Soo;Cho, Sung-Taig;Kim, Kwang-Mo;Yeo, Hwan-Myeong
    • Journal of Korea Foresty Energy
    • /
    • v.25 no.2
    • /
    • pp.1-8
    • /
    • 2006
  • The physical, mechanical and chemical properties of old and new Korean red pine (Pinus densiflora) were analyzed. The old woods were from dismantled timbers of Bonjungsa temple. The crystallized resin in the latewood was observed by microscopic analysis. Also, reduction of specific gravity, occurrence of microscopic cleavage of tracheid was observed in the old wood. The angle of microscopic cleavage of tracheid is estimated with the same angle of micro-fibril angle of 52 layer. The bending, compression and shear strength of old world were decreased about 35-27% than those of new wood. Dynamic modulus of elasticity measured by ultrasonic nondestructive test has the tendency of reducing by the time elapse of the wood usage. Therefore, deterioration of wood could be measured by reduction of specific gravity and dynamic MOE. The static MOE and mechanical properties of old wood could be predictable by measuring dynamic MOE in the longitudinal direction. Extractives of the old wood in 1-% NaOH solution are larger quantity than new wood. Therefore the decay of the wood could be evaluated by analyzing the chemical compound, especially 1-% NaOH solution. The results of this research could be used for understanding and prediction of the changing properties with elapsing time of wood.

  • PDF

Image Quality Analysis According to the of a Linear Transducer (선형 탐촉자에서 관심 시각 영역 변화에 따른 화질 분석)

  • Ji-Na, Park;Jae-Bok, Han;Jong-Gil, Kwak;Jong-Nam, Song
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.975-984
    • /
    • 2022
  • Since a linear transducer has an area of interest equal to the length of the transducer, the area of interest can be expanded using the virtual convex function installed in the device.However, it was thought that the change in the direction of the ultrasonic sound velocity according to the change in the visual area of interest would affect the image quality, so this was objectively confirmed. For this study, image evaluation and SNR·CNR of the phantom for ultrasound quality control were measured. As a result, in the phantom image evaluation, both images were able to identify structures in functional resolution, grayscale, and dynamic range. However, it was confirmed that the standard image was excellent in the reproducibility of the size and shape of the structure. As a result of SNR·CNR evaluation, SNR·CNR of most trapezoidal images was low, except for structures at specific locations. In addition, through the statistical analysis graph, it was further confirmed that the SNR and CNR for each depth decreased as the size of the cystic structure decreased. Through this study, it was confirmed that the use of the function has the advantage of providing a wide visual area of interest, but it has an effect on the image quality. Therefore, when using the virtual convex function, it is judged that the examiner should use it in an appropriate situation and conduct various studies to acquire high-quality images and to improve the understanding and proficiency of the equipment.

COMPARATIVE STUDY ON MORPHOLOGY OF CROSS-SECTION AND CYCLIC FATIGUE TEST WITH DIFFERENT ROTARY NITI FILES AND HANDLING METHODS (수종의 NiTi 전동 파일 단면 형태 비교 및 pecking motion의 사용방법이 피로 파절에 미치는 영향)

  • Kim, Jae-Gwan;Kum, Kee-Yeon;Kim, Eui-Seong
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.2
    • /
    • pp.96-102
    • /
    • 2006
  • There are various factors affecting the fracture of NiTi rotary files. This study was performed to evaluate the effect of cross sectional area, pecking motion and pecking distance on the cyclic fatigue fracture of different NiTi files. Five different NiTi $files-Profile^{(R)}$ (Maillefer, Ballaigue, Switzerland), $ProTaper^{TM}$(Maillefer, Ballaigue, Switzerland), $K3^{(R)}$ (SybronEndo. Orange, CA) , Hero $642^{(R)}$ (Micro-mega, Besancon, France), Hero $Shaper^{(R)}$ (Micro-mega, Besancon, France)-were used. Each file was embedded in temporary resin, sectioned horizontally and observed with scanning electron microscope. The ratio of cross-sectional area to the circumscribed circle was calculated. Special device was fabricated to simulate the cyclic fatigue fracture of NiTi file in the curved canal,. On this device, NiTi files were rotated (300rpm) with different pecking distances (3 mm or 6 mm) and with different motions (static motion or dynamic pecking motion) . Time until fracture occurs was measured. The results demonstrated that cross-sectional area didn't have any effect on the time of file fracture. Among the files, $Profile^{(R)}$ took the longest time to be fractured. Between the pecking motions, dynamic motion took the longer time to be fractured than static motion. There was no significant difference between the pecking distances with dynamic motion, however with static motion, the longer time was taken at 3mm distance. In this study, we could suggest that dynamic pecking motion would lengthen the time for NiTi file to be fractured from cyclic fatigue.

Feature Points Tracking of Digital Image By One-Directional Iterating Layer Snake Model (일방향 순차층위 스네이크 모델에 의한 디지털영상의 특징점 추적)

  • Hwang, Jung-Won;Hwang, Jae-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.44 no.4 s.316
    • /
    • pp.86-92
    • /
    • 2007
  • A discrete dynamic model for tracking feature points in 2D images is developed. Conventional snake approaches deform a contour to lock onto features of interest within an image by finding a minimum of its energy functional, composed of internal and external forces. The neighborhood around center snaxel is a space matrix, typically rectangular. The structure of the model proposed in this paper is a set of connected vertices. Energy model is designed for its local minima to comprise the set of alternative solutions available to active process. Block on tracking is one dimension, line type. Initial starting points are defined to the satisfaction of indent states, which is then automatically modified by an energy minimizing process. The track is influenced by curvature constraints, ascent/descent or upper/lower points. The advantages and effectiveness of this layer approach may also be applied to feature points tracking of digital image whose pixels have one directional properties with high autocorrelation between adjacent data lines, vertically or horizontally. The test image is the ultrasonic carotid artery image of human body, and we have verified its effect on intima/adventitia starting points tracking.

Investigation of Interfacial Adhesion of Different Shapes of Nano Carbon Fillers Reinforced Glass Fiber/Epoxy Composites by Spray Coating (형상이 다른 나노입자 스프레이 코팅에 따른 탄소계 강화 유리섬유와 에폭시 수지간 계면강도 관찰)

  • Kwon, Dong-Jun;Wang, Zuo-Jia;Choi, Jin-Young;Shin, Pyeong-Su;Lee, En-Seon;Park, Joung-Man
    • Composites Research
    • /
    • v.27 no.3
    • /
    • pp.109-114
    • /
    • 2014
  • Manufacture of nancomposites has simple process for developing nanocomposites due to the increasing applications using nanofillers. This work studied nanofiller coated glass fiber for reinforcing material with good wetting and conductivity and the morphology of nanofiller coated glass fiber was analyzed by FE-SEM. The durability of reinforced glass fiber was investigated with different shapes of nanofillers using sonication rinsing method. Fatigue test was performed to evaluate the adhesion of reinforcing interface and stability of nanofiller coating layer for single fiber reinforced composites. Apparent modulus and conductivity of nanofiller coating layer were evaluated to realize multifunctional of nanocomposites. Fiber type of nanofiller was better than plate type due to better cohesion between fiber and nanofillers. At last, the stability of fiber type nanofiller of coating layer has better durability and conductivity than plate type case.

A Framework of Recognition and Tracking for Underwater Objects based on Sonar Images : Part 2. Design and Implementation of Realtime Framework using Probabilistic Candidate Selection (소나 영상 기반의 수중 물체 인식과 추종을 위한 구조 : Part 2. 확률적 후보 선택을 통한 실시간 프레임워크의 설계 및 구현)

  • Lee, Yeongjun;Kim, Tae Gyun;Lee, Jihong;Choi, Hyun-Taek
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.3
    • /
    • pp.164-173
    • /
    • 2014
  • In underwater robotics, vision would be a key element for recognition in underwater environments. However, due to turbidity an underwater optical camera is rarely available. An underwater imaging sonar, as an alternative, delivers low quality sonar images which are not stable and accurate enough to find out natural objects by image processing. For this, artificial landmarks based on the characteristics of ultrasonic waves and their recognition method by a shape matrix transformation were proposed and were proven in Part 1. But, this is not working properly in undulating and dynamically noisy sea-bottom. To solve this, we propose a framework providing a selection phase of likelihood candidates, a selection phase for final candidates, recognition phase and tracking phase in sequence images, where a particle filter based selection mechanism to eliminate fake candidates and a mean shift based tracking algorithm are also proposed. All 4 steps are running in parallel and real-time processing. The proposed framework is flexible to add and to modify internal algorithms. A pool test and sea trial are carried out to prove the performance, and detail analysis of experimental results are done. Information is obtained from tracking phase such as relative distance, bearing will be expected to be used for control and navigation of underwater robots.