• Title/Summary/Keyword: 동적연성

Search Result 197, Processing Time 0.022 seconds

Investigation on Friction Noise in Beam Structure Under Mode-Coupling by Using Analytical Finite-Element Squeal Model (스퀼 융합모델을 이용한 모드연성에 의한 빔 구조 마찰 소음 연구)

  • Kang, Jaeyoung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.5
    • /
    • pp.545-550
    • /
    • 2014
  • This study provided the analytical finite element method estimating the friction-induced noise on the complex beam structure. The frictional contact model was theoretically constructed and applied to the analytical finite element squeal model. The numerical results showed that the beam structure was excited by the mode-coupling instability of the specific system modes. Also, the direction of friction was shown to influence on the dynamic instability of the modes. Besides, the unstable modal frequencies estimated from the numerical calculation were validated by the experiment of the actual beam structure.

Prediction of the Out-of-plane Motion due to the In-plane Excitation (평면내 방향 기진력에 의한 평면밖 방향 운동의 예측)

  • Oh, Il-Geun
    • Journal of Ocean Engineering and Technology
    • /
    • v.7 no.2
    • /
    • pp.141-149
    • /
    • 1993
  • 삼 자유도를 가진 부유물체의 동적 응답을 이론적으로 연구하였다. 평면내 방향 운동모우드에 대한 지배방정식을 선형화한 후, 그들의 조화해를 평명밖 방향 운동모우드의 방정식과 연성시켰다. 그렇게 해서 주어지는 방정식은 시간에 따라 변화하는 계수를 가진 형태로서, 평면밖 방향의 운동만을 보일 것으로 예측되는 부유물체가 평면밖 방향의 운동을 보일 수도 있음을 밝혔다. 동역학적 불안정성과 그 결과로 나타나는 평면밖 방향의 대진폭 운동을 보이고 있다. 본 결과는 주기적으로 동요하는 부유물체가 서로 연성된 운동을 하는 현상으로도 해석할 수 있다.

  • PDF

Seismic Analysis of Rack Structure with Fluid-Structure Interaction (유체와 구조물의 연성을 고려한 rack 구조물의 내진해석)

  • Kim, S.J.;Lee, Y.S.;Ryu, C.H.;Yang, K.H.;Jung, S.H.
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.465-470
    • /
    • 2001
  • In this study, the seismic analysis of rack structure with fluid-structure interaction is performed through use of the Finite Element Method(FEM) code ANSYS. Fluid-structure interaction can specify in terms of an hydrodynamic effect which is defined as the added mass per unit length divided by the area of the cross section. Using the Floor Response Spectrum(FRS) obtained through the time-history analysis, modal analysis and seismic analysis under Operating Basis Earthquake(OBE) and Safe Shutdown Earthquake(SSE) condition is carried out. The fluid-structure interaction effects on the rack structure are investigated.

  • PDF

Exact Solutions for Bending-Torsion Coupled Vibration of Composite Timoshenko Beam (복합재 티모센코 보의 굽힘 비틀림 연성 진동에 대한 엄밀해)

  • Hong, Seong-Uk;Gang, Byeong-Sik;Park, Jung-Yun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.10
    • /
    • pp.1559-1566
    • /
    • 2001
  • This paper proposes a dynamic analysis method for obtaining exact solutions of composite Timoshenko beams, which are inherently subjected to both the bending , and torsional vibrations. In this paper, the bending-torsion coupled vibration of composite Timoshenko beam is rigorously modelled and analyzed. Two numerical examples are provided to validate and illustrate the bending-torsion coupled vibration of composite Timoshenko beam structure. The numerical examples prove that the proposed method is of great use for the dynamic analysis of dynamic structures composed of multiply connected composite Timoshenko beams.

Marine Safety Technology using Highly Advanced M&S System (고도 정밀 M&S 시스템을 이용한 해양안전기술)

  • Lee, Sang-Gab
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2014.10a
    • /
    • pp.140-141
    • /
    • 2014
  • 최근 대용량 고속 컴퓨터의 출현과 고도 비선형 동적 해석 소프트웨어가 개발됨에 따라 안전사고 규명와 안전설계 등에 고도 정밀 Modeling & Simulation(M&S) 시스템이 널리 적용되고 있다. 특히 해양안전은 천배의 밀도를 갖는 해양에서의 내충돌 및 내충격 응답을 실선규모로 규명 분석하여야 할 것이다. 이를 위해서는 고도 정밀 M&S 시스템에 유체-구조 연성(Fluid-Structure Interaction, FSI) 해석기법을 적용하여야 보다 정확하고 합리적인 안전성을 평가할 수 있다. 여기서는 이러한 고도 정밀 M&S 시스템을 적용한 해양안전기술의 적용 분야를 소개하고자 한다.

  • PDF

Design of Soft Real-time Xen Hypervisor (연성 실시간 Xen 하이퍼바이저 설계)

  • Hur, Kyung Woo;Kim, Jin;Ko, Young Woong
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2010.04a
    • /
    • pp.119-122
    • /
    • 2010
  • 본 논문에서는 Xen 가상 머신에 연성 실시간 기능을 제공하기 위한 방안을 제시한다. 현재 실시간 하이퍼바이저(hypervisor)는 대부분 경성 실시간(hard real-time) 보장을 위하여 자원을 파티션(partition)하고 고정된 태스크에 대한 수행을 지원한다. 본 연구에서는 오픈 환경을 위한 조합적 실시간 프레임워크에 기반한 계층형 실시간 스케줄링 시스템을 제안하고 있다. 제안하는 시스템은 오픈 환경에서 동적으로 태스크 및 컴포넌트의 유입이 가능하게 설계되었다. 제안하는 시스템에 대한 사전 연구 결과로써 Xen 플랫폼의 오버헤드 분석 결과를 제시하고 있다.

Dynamic Interaction of Track and Train System on Open Gap by Rail Breaks (레일 파단시 장대레일 개구부에서의 궤도-차량 동적상호작용)

  • Kang, Yun Suk;Kang, Young Jong;Yang, Shin Chu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.6D
    • /
    • pp.895-904
    • /
    • 2008
  • CWR (Continuous Welded Rail) may be broken when a temperature drop below the neutral temperature changes in axial force, causing tensile fracture and rail gap, in winter. Rail-breaks may lead to the damage of the rail and wheel by dynamic load, and the reduction of running safety if not detected before the passage of a train. In this study, the track and train coupled model with open gap for dynamic interaction analysis, is proposed. Linear track and train systems is coupled by the nonlinear Herzian contact spring and the complete system matrices of total track-train system is constructed. And the interaction phenomenon considering open gap, was defined by assigning the irregularity functions between the two sides of a gap. Time history analysis, which have an iteration scheme such as $Newmark-{\beta}$ method based on Modified Newton-Raphson methods, was performed to solve the nonlinear equation. Finally, numerical studies are performed to assess the effect of various parameters of system, apply to various speeds, open gap size and the support stiffness of rail.

Seismic Evaluation of Steel Moment Frame Buildings based on Different Response Modification Factors and Fundamental Periods (반응수정계수와 주기의 영향에 대한 철골모멘트저항골조 건물의 내진성능평가)

  • Shin, Ji-Wook;Lee, Ki-Hak;Lee, Do-Hyung
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.5
    • /
    • pp.47-56
    • /
    • 2008
  • This study was performed to evaluate the effect of Response modification factors (R-factor) in 3-, 9- and 20- story steel Moment Resisting Frame (MRF) buildings. Each structure was designed using a R-factor of 8, as tabulated in the 2000 International Building Code provision (IBC 2000) and Korea Building Code (KBC) 2008. In order to evaluate the maximum and minimum performance expected for such structures, an upper bound and lower bound design were adopted for each model. Next, each analytical model was designed using different R-factors (8, 9, 10, 11, 12) and four different structural periods with the original fundamental period. For a detailed case study, a total of 150 analytical models were subjected to 20 ground motions representing a hazard level with a 2% probability of being exceeded in 50 years. In order to evaluate the performance of the structures, static push-over and non-linear time history analysis (NTHA) were performed, and displacement ductility demand was investigated to consider the ductility capacity of the structures. The results show that the dynamic behaviors for the 3- and 9-story buildings are relatively stable and conservative, while the 20-story buildings show a large displacement ductility demand due to dynamic instability factors. (e.g. P-delta effect and high mode effect)

Seismic Performance of Circular RC Columns Retrofitted Using Ductile PET Fibers (고연성 PET 섬유로 보강된 철근콘크리트 원형 기둥의 내진성능)

  • Vachirapanyakun, Sorrasak;Lim, Myung-Kwan;Choi, Dong-Uk
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.3
    • /
    • pp.289-298
    • /
    • 2016
  • An experimental research was performed using fibers for the purpose of retrofitting existing reinforced concrete circular columns. Glass fiber (GF) and polyethylene terephthalate (PET) were used as well as combined GF+PET (HF). PET has high tensile strength (over 600 MPa) and high ductility (about 15%), but has very low elastic modulus (about 1/6 of GF). A total of four columns was tested against laterally applied reverse cyclic load: control column, GF-, PET-, and HF-strengthened columns. All columns retrofitted using fibers demonstrated improved moment capacity and ductility. Moment capacity of GF-, PET-, and HF-strengthened columns was 120%, 107%, and 120% of the control column, respectively. Drift ratio of all retrofitted columns also increased by 63 ~ 83% over the control column. The final failure mode of the control column was main bar buckling. The final failure mode of the GF- and HF-strengthened columns was GF rupture while that of the PET-strengthened column was main bar rupture in tension. No damage was observed for PET at the ultimate stage due to excellent strain capacity intrinsic to PET. Current test results indicate that PET can be effectively used for seismic retrofit of RC columns. It is noted that the durability characteristics of PET needs to be investigated in the future.

Criterion for ductile crack initiation with strength mismatch under dynamic loading (강도적 불균질을 갖는 구조물의 동적하중하에서의 연성크랙 발생조건)

  • 안규백;일본명;일본명;방한서;일본명
    • Proceedings of the KWS Conference
    • /
    • 2003.11a
    • /
    • pp.179-181
    • /
    • 2003
  • The present study focuses on the effect of geometrical discontinuity, strength mismatch, which can elevate plastic constraint due to heterogeneous plastic straining, and loading rate on the ductile crack initiation using two-parameter criterion. Fracture initiation testing has been conducted under static and dynamic loading using circumferentially notched round-bar specimens. In order to evaluate the stress/strain state in the specimens, especially under dynamic loading, a thermal elastic-plastic dynamic finite element (FE) analysis considering the temperature rise due to plastic deformation has been carried out.

  • PDF