• Title/Summary/Keyword: 동적소화

Search Result 15, Processing Time 0.019 seconds

Dynamic Extinction of Solid Propellants by Depressurization of Combustion Chamber (연소실 압력 강하에 의한 고체 추진제의 동적 소화)

  • Jeong, Ho-Geol;Lee, Chang-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.2
    • /
    • pp.91-97
    • /
    • 2002
  • Dynamic extinction of solid propellants subjected to rapid pressure drop was studied with the aid of energy equation of condensed phase and flame model in gas phase. It is found that the total residence time($\tau_\gamma$) which measures the residing time of fuel in the reaction zone may play a crucial role in determining the dynamic response of the combustuion to extinction. Residence time was modeled by various combinations of diffusion and chemocal kinetic time scale. Effect of pressure history coupled with chamber volume on the extinction response was also performed and was found that dynamic extinction is more susceptible in a confined chamber than in open geometry. And, dynamic extinction was revealed to be affected profoundly by diffysion time scale rather than chemical kinetic time scale.

The Effect of Radiative Heat Flux on Dynamic Extinction in Metalized Solid Propellants (복사열전달이 고체 추진제의 동적소화에 미치는 영향)

  • Jeong, Ho Geol;Lee, Chang Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.2
    • /
    • pp.72-79
    • /
    • 2003
  • A numerical calculation was conducted to estimate and to elucidate the role of the radiative heat flux from metal particles(Al, $Al_2O_3$) on the dynamic extinction of solid propellant rocket where the rapid depressurization took place. Anon-linear flame modeling implemented by the residence time modeling for metalized propellant was adopted to evaluate conductive heat flux to the propellant surface. The radiative heat feed back was calculated with the aid of a modified comvustion-flow model as well. The calculation results with the propellant of AP:Al:CTPB=76:10:14 had revealed that the radiative heat flux is approximately 5~6% of total flux at the critical depressurization rate regardless of chamber geometry (open or confined chamber). It was also found that the dynamic extinction in open geometry could be predicted at the depressurization rate about 45% larger with radiative heat feedback than without radiation. Thus, it should be claimed that even a small amount of radiative flux 5~6% could produce a big error in predicting the critical depressurization rate of the metalized propellant combustion.

A Study on Characteristic of Extinguishment for Solid Propellants Composition by Rapid Depressurization (압력 강하에 따른 추진제 조성별 소화 특성 분석)

  • Choi, Jaesung;Lee, Choonghee;Lim, Jaeil;Lee, Hyoungjin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.21 no.5
    • /
    • pp.37-45
    • /
    • 2017
  • Extinguishment of a burning solid propellant is difficult, however, dynamic extinction can be induced by fast depressurization in combustion chamber. This paper describes experimental results for the characteristics of extinguishment for composite solid propellants by rapid depressurization. For various composition of solid propellants, depressurization ratio which can induce extinguishment of combustion was obtained using experimental apparatus with rupture disk. Experimental results showed that particle size of oxidizer, mixing ratio of oxidizers with different particle size and contents of metal fuel can affect on the characteristics extinguishement for solid propellant.

CFD Simulation of Combustion and Extinguishment of Solid Propellants by Fast Depressurization (고체 추진제의 연소 및 빠른 감압에 의한 소화 모델 CFD 모사)

  • Lee, Gunhee;Jeon, Rakyoung;Jung, Minyoung;Shim, Hongmin;Oh, Min
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.1
    • /
    • pp.15-23
    • /
    • 2019
  • In this study, an extinguishment model of a three-dimensional solid propellant rocket was developed by combustion and fast depressurization to control the thrust of a solid rocket. Computational fluid dynamics simulation was carried out to ascertain the change in flow patterns in the combustion chamber and the extinguishment process by using a pintle. An ammonium perchloride was used as the target propellant and the dynamic behavior of its major parameters such as temperature, pressure, and burning rate was predicted using the combustion model. The dynamic behavior of the combustion chamber was confirmed by fast depressurization from an initial pressure of 7 MPa to a final pressure of 2.5 MPa at a depressurization rate of approximately -912 MPa/s.

Seismic Response Estimation of Water Extinguishing Facilities using Shaking Table Tests (진동대 실험을 통한 수계 소화설비의 지진응답평가에 관한 연구)

  • Nam, Min-Jun;Park, Seung-Hee;Kim, Dong-Joon;Choi, Jun-Sung
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.9-18
    • /
    • 2012
  • In this study, a shaking table test was performed for the evaluation of water extinguishing facilities. Water extinguishing facilities, such as a general pipe, a seismic pipe (Loof type) and a pump, were used in the experiment. This captured the dynamic characteristics of water extinguishing systems by earthquake records at El-Centro with a 50%, 70%, 100%, 120% level. As a result, seismic type facilities have excellent seismic performance compared to general facilities. By using the acceleration response spectrum, not only is the performance evaluation of water extinguishing facilities able to be determined, but also the deformation of facilities in low earthquake levels can be known. This proposed approach can determine the seismic performance evaluation of water extinguishing facilities and verify seismic performance criteria.

Evaluation of the Closed-type Sprinkler Head Activation Time (밀폐형 스프링클러 헤드의 동작시간 평가)

  • Moon-Hak, Jee;Sung-Yull, Hong
    • Fire Science and Engineering
    • /
    • v.18 no.3
    • /
    • pp.1-8
    • /
    • 2004
  • As a predominant active fire suppression method, closed-type sprinkler systems are used for the purpose of fire control and suppression at the nuclear power plants as well as the industrial facilities. It goes without saying that the proper selection of the system guarantees the adequate actuation of the thermal device. Consequently, the appropriate evaluation should be executed for the thermal behavior with the theoretical and empirical approach. For this purpose, the comparison of activation time for the fusible-link type sprinkler head with the simplified fire case and t-square fire growth case was evaluated. At this paper, the comparison output was presented with the tendency of thermal behavior. In addition, we issued some technical comments for the most appropriate equation in case of the estimation of the sprinkler head activation time. We also raised some idea that should be incorporated for the usage of the t-square equation for the realistic application in the field of the performance-base fire protection approach.

Comparison of Resin Impregnation and Mechanical Properties of Composites Based on Fiber Plasma Treatment (섬유 플라즈마 처리에 따른 복합재료의 수지 함침성 및 기계적 특성 비교)

  • Seong Baek Yang;Donghyeon Lee;Yongseok Lee;Dong-Jun Kwon
    • Composites Research
    • /
    • v.36 no.6
    • /
    • pp.388-394
    • /
    • 2023
  • In composites manufacturing, increasing resin impregnation is a key way to speed up the manufacturing process and improve product quality. While resin improvement is important, simple fiber surface treatments can also improve resin flowability. In this study, different plasma treatment times were applied to carbon fiber fabrics to improve the impregnation between resin and fiber. Electrical resistivity measurements were used to evaluate the dispersion of resin in the fibers, which changed with plasma treatment. The effect of fiber surface treatment on resin spreadability could be observed in real time. When inserting a carbon fiber tow into the resin, the amount of resin that soaked into the tow was measured to objectively compare resin impregnation. Five minutes of plasma treatment improved the tensile and compressive strength of the composite by more than 50%, while reducing the void content and increasing the fire point impregnation flow rate. Finally, a dynamic flexural fatigue test was conducted using a portion of the composite used as an architectural composite part, and the composite part did not fail after one million cycles of a 3 kN load.

Dynamic Behavior Analysis of Tiny Robot

  • Wang, Zhao;Lim, Eng Gee
    • Journal of Convergence Society for SMB
    • /
    • v.4 no.1
    • /
    • pp.17-29
    • /
    • 2014
  • The wireless capsule endoscopy played an important role as the evolutionary medical device to solving the difficulties such as diagnosing the intestine diseases. Due to the limited size and functions, it has some drawbacks. The most obstacle thing is the disability of self-motion, it means that it cannot provide the speed problem. Hence, the characteristics of human digestion system is briefly introduced, especially the intestine, to get the information of endoscopy dynamics. Next, in order to make an abstraction of the condition, a new dynamic friction model called LuGre model is introduced and clearly analysed to get the characteristics and the usage of the model. By the consideration of parameters that are tightly related with the real situation of the capsule endoscopy. The Matlab Simulink was applied to build the model and verified by the simulation to discover the features.

  • PDF

STUDIES ON THE MATHEMATICAL KINETICS FOR THE REMOVABLE MOVING SCREEN MEDIA-ACTIVATED SLUDGE PROCESS (회전형 반고정망 활성슬럿지 공법의 수학적 해석에 관한 연구 2. 슬럿지 생산량 및 축적과정과 유출수의 수질에 대하여)

  • HAN Ung-Jun;HAN Yeong-Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.12 no.3
    • /
    • pp.175-179
    • /
    • 1979
  • One of the major problems in tile activated sludge system has been difficulty in separating the microbial solids from the treated effluent and in returning them to the aeration tank. Another problem has been the digestion of the excess activated sludge. In constrast, it has not been difficult to separate the microbial solids from the treated effluent from the biological fixed-film systems(RBC process, Trickling Filter, FAST process). These systems have also featured less sludge production. Recently, it was proposed to experiment with the RESMAS process in order to eliminate the settling tank and sludge concentration facilities and to reduce the quantity of excess sludge for final disposal. The effluent quality could be predicted by .the concept of the maximum accumulation capacity. However, the hydraulic characteristics of the screen media in the RESMAS reactor were not dynamic. The object of the present study is to evalute the sludge accumulation rate and effluent quality prediction in the REMSMAS process designed in the dynamic hydraulic structure. This process can eliminate the final sedimentation tank and sludge concentration tank needed in the RBC, CMAS, Trickling Filter and FAST processes. Also, the effluent quality is desirable to compare with other processes. It appeared that the value of the sludge holding capacity was higher than those of the RESMAS and FAST processes, and the periods of the critical operating time were proportional to the substrate hydraulic loadings.

  • PDF