• Title/Summary/Keyword: 도로융설시스템

Search Result 14, Processing Time 0.02 seconds

A Basic Study on the Performance CFD simulation of Road Snow-melting system by Ground Source Heat Pump (지열원 히트펌프를 이용한 도로융설시스템의 CFD 성능예측에 관한 기초연구)

  • Choi, Duk-In;Kim, Joong-Hun;Kim, Jin-Ho;Hwang, Kwang-Il
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.6 no.2
    • /
    • pp.23-28
    • /
    • 2010
  • Fluent ver.6.3 is used as CFD(Computational Fluid Dynamics) simulator to predict the performance of snow-melting system by geothermal pipes energy. As the results of this simulation, it is clearly shown that $50^{\circ}C$ of working fluid in to geothermal evaluated as more effect comparing to $45^{\circ}C$ of working fluid. The Surface temperature is come to $5^{\circ}C$ at 1m/s speed and $50^{\circ}C$ temperature of the working fluid.

Study about the Evaluation of Freezing Risk Based Road Surface of Solar Radiation (도로 노면 일조량에 따른 결빙 위험도 평가 방법에 관한 연구)

  • Lee, Dong-Hyun;Jeong, Won-Seok;Kim, Hong-Jin;Kim, Jiwon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.5
    • /
    • pp.130-135
    • /
    • 2013
  • Anti-icing system can reduce traffic accidents and congestion by quickly removing the frozen road surface area. there is no decision criteria for determining application of the Anti-icing system in Korea. In this study, we proposed the decision criteria for determining application of the anti-icing system based on weather and road conditions, i.e., geometric and topographic conditions. Regional climate survey, Solar Radiation analysis, and dynamic vehicle simulation considered road geometry was conducted to standardize the installation method of anti-icing system. Also, we have developed a software that can be determined an installation of anti-icing system.

Field Test to Investigate Heat Transferring Effect of Carbon Fiber Heating Wire on the Concrete Slab (현장시험을 통한 Carbon fiber heating wire의 콘크리트슬래브 열전달 효과)

  • Kim, Hee Su;Ban, Hoki
    • Journal of the Korean GEO-environmental Society
    • /
    • v.20 no.4
    • /
    • pp.31-38
    • /
    • 2019
  • Field tests with carbon fiber heating wire (CFHW) embedded inside concrete slab were performed to present the alternative heating material capable of avoid the adverse effects of traditional de-freezing salt on the structures and environment. The CFHW was inserted into the concrete slab in the shape of 'ㄷ' to improve the heat superposition and the temperature on the surface was measured using iButton. The results showed that the temperature where the CFHW's were faced with each other increased to above zero after 12-hour at outdoor air temperature of $-6^{\circ}C$. Comparatively, the temperature slightly increased where the CFHW was embedded on one side because the heat was not superimposed. Hence, it can be said that the CFHW is a suitable heating material to prevent the concrete road from being frozen.

Design Standard for Lane Operation in Bridges and Tunnels (교량 및 터널구간 차로운영 설계기준)

  • You, Ho-In;Oh, Young-Tae;Lee, Choul-Ki;Chung, Woo-Hyun
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.6 no.3
    • /
    • pp.33-44
    • /
    • 2007
  • Prohibition of lane changes in bridges and tunnels have been many problems in throughputs of expressways caused by heavy vehicles and slow-moving traffics. Nevertheless, those are constructed actively by the general trends, which are preservation of environment and ecosystem are more important, because mountainous districts are about 70% across the whole extent of Korea. In this paper, the proper design standards for permission of lane changes in bridges and tunnels classified into structure, safe, and driver's conveniences are suggested as follows. 1. Right shoulder should have more than 2.5m in bridges and tunnels. 2. Sufficient equipments of guidance like as directional signs, fingerposts, variable message signs, and markings should be established to smooth and safe lane changes of drivers. 3. Snow melting systems should be established in bridges worried about freezing. 4. Tunnels must be not only satisfied standards for prevention of disasters (2004.11) and lighting rules (KSA 3703), but also established anti-freezing facilities in entrance and exit. 5. The drivers should have honed on their car lights.

  • PDF