• Title/Summary/Keyword: 덕트장치

Search Result 81, Processing Time 0.024 seconds

A Design of Effective Architecture for Constructing Services Systems (서비스 시스템 구축을 위한 효율적 아키텍처 설계)

  • La, Hyun-Jung;Kim, Sung-Ahn;Kim, Soo-Dong
    • Journal of KIISE:Software and Applications
    • /
    • v.35 no.3
    • /
    • pp.137-148
    • /
    • 2008
  • Services system which has been emerging as a new way of application development utilizes services as fundamental units for developing a system. Services system can offer services within web environment as well as the ubiquitous environment where mobile devices are connected to wired or wireless network. In order to provide the functionality that meets users' requirements, the most appropriate service should be selected among candidate services by taking requests and context information into account. Therefore, it is important that the service system should provide services to users by dynamically adapting to users' requirements and context information. Since different users request same functionality with different context information, one service can be differently offered to users so that variability can happen to the service systems. Most researches on context-aware systems have a tendency to solve dynamic adaptation by using more or less ad hoc manner In this paper, we consider various types of services which are performed according to context information as variability and propose adaptable architecture by applying concepts of product line architecture in order to deal with variabilities systematically.

NUMERICAL STUDY ON FLOW CHARACTERISTIC IN THE HEAT RECOVERY STEAM GENERATOR (배열회수장치의 유동특성에 관한 수치적 연구)

  • Choi, H.K.;Yoo, G.J.;Shin, B.J.;Kim, C.H.
    • Journal of computational fluids engineering
    • /
    • v.15 no.1
    • /
    • pp.17-23
    • /
    • 2010
  • Performance improvements of the heat recovery steam generator(HRSG) can be achieved by improving the flow distribution of exhaust gases for a various type of different equipments. A number of design parameters are systematically investigated and their effects on an index of velocity deviation established. The parameters include the three shape of the transition duct and the wide range of the guide vane angles. The numerical results clearly reveal feature of the flow pattern in the transition duct, velocity deviation and pressure drop at tube bank part.

Development of silencer for apartment floor between bathroom noise (공동주택 화장실 층간 소음 저감기 개발)

  • Kim, Young-Su;Lee, Jae-Kuck;Kim, Chang-Yeol
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.715-721
    • /
    • 2008
  • 공동주택에서의 음환경 성능은 실내환경의 질과 연관시켜 설계단계부터 충분한 검토가 필요한 성능항목이다. '국토해양부'는 '공통주택 성능등급 표시제도'에서 Air Duct를 통해 상하층간 전파되는 소음을 제어하기 위한 대책을 요구하고 있다. 이에 화장실에 적합한 구조 및 재질로 소음 저감기를 개발하고, 소음기 성능평가 장치를 구성하여 이론과 비교평가하고, 실제 현장에 설치 시 적용효과를 분석하였다.

  • PDF

TURBULENCE HEAT TRANSFER ENHANCEMENT TECHNIQUE FOR SQUARE DUCT WITH HIGH ASPECT RATIO (종횡비가 큰 사각 덕트내 난류 유동의 대류 열전달 증진 기술에 대한 연구)

  • Lee, Chan-Yong;Shin, Seung-Won;Chung, Ha-Seung;Park, Seung-Ho
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.305-307
    • /
    • 2010
  • In this study, we develop a method to achieve heat transfer enhancement inside a square duct with high aspect ratio without changing any inner structures. Especially, a method to lower the possible maximum temperature is suggested if constant heat flux is provided to single surface of square duct. Knowing the fact that heat transfer rate is inversely proportional to flow area, we proposed tapered channel concept which uses narrower gap toward the flow exit where the maximum temperature is expected. To maintain equivalent power consumption, inlet section has been enlarged. To verify the proposed concept, experimental tests have been performed.

  • PDF

Effect of Pitch Angle Variations On Performance Of Pod Type Waterjet (로터 피치각 변화에 따른 Pod형 워터제트 성능비교)

  • Kim J. H.;Park W. G.;Chun H. H.;Kim M. C.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.30-34
    • /
    • 2005
  • 고속 선박을 추진하는 한 방법으로 널리 사용되는 물분사 추진은 물을 내부 덕트로 빨아들여 임펠러로 물을 가속시켜 노즐을 통해 분사시킴으로써 입출구의 운동량차이에 의해 추력을 얻는 추진장치이다. 선박의 목적에 따라 사용되는 다양한 형태의 물분사 추진기의 개발을 위하여 모형실험을 통하여 그 성능을 검증하는 부분에서 로터의 피치각 변화에 따른 추진기의 성능 실험을 하는 것은 많은 비용과 시간이 따른다. 따라서 이러한 문제를 해결하기 위하여 본 연구에서는 추진기 내부의 유동장을 4가지 피치각에 따라 추진력을 3차원 비압축성 Navier-Stokes 방정식을 이용하여 해석하였다. 로터의 회전을 고려하여 슬라이딩 다중 격자기법을 적용하였고 추력계수, 토크계수, 그리고 모멘텀을 해석 결과와 비교 분석을 통하여 추진기의 성능과 효율을 추정하였다.

  • PDF

Analysis and Performance Test for the Fan of a Wide Area Sprayer of Livestock Farm (축산 농가용 광역방제기 팬의 성능실험 및 분석)

  • Hong, J.T.;Min, B.R.;Kim, D.W.;Seo, K.W.;Kim, W.;Lee, S.K.;Kim, S.Y.;Lee, D.W.
    • Journal of Animal Environmental Science
    • /
    • v.13 no.2
    • /
    • pp.105-112
    • /
    • 2007
  • This research was carried out to test and analyse the capability of a fan for development of a sprayer in actual livestock farm. A fan was designed and made to be able to spray agricultural chemicals within 140mm in a maximum scattering range and 100m in an effective scattering range. Accordingly, its' flow rate was $3,600\;m^3/min$, and static pressure was 100 mmAq for a wide area sprayer to be sprayed widely and far. Fan performance, which was given $600\;m^3/min$ flow rate and 500 mmAq total pressure, was tested fur basic experiment. As the result, the axial power showed minimum error, which be designed to keep the fan performance. And power efficiency was the maximum. Sound level was 92.1dB that wasn't enough to environmental standard. If we take the sealed place into consideration, sound level is suitable for environmental standard.

  • PDF

Prediction of Performance of Waterjet Propulsors by Surface Panel Method (패널법에 의한 물 분사 추진장치의 성능해석)

  • Moon, II-Sung;Lee, Chang-Sup;Song, In-Haeng;Kim, Ki-Sup
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.34 no.4
    • /
    • pp.31-41
    • /
    • 1997
  • This paper describes a potential-based panel method formulated for the prediction of the steady performance of a waterjet propulsor. The method employs normal dipoles and sources distributed on the solid surfaces such as the impeller/stator blades, hub and duct, and normal dipoles in the shed wakes trailing the impeller and stator to represent the potential flow around the waterjet propulsor. To define a closed boundary surface, the inlet and outlet open boundary surfaces are introduced where the sources and dipoles are distributed. The kinematic boundary condition on the solid boundary surface is satisfied by requiring that the normal component of the total velocity should vanish. On the inlet surface, the total inflow flux into the duct is specified, and on the outlet surface the conservation of mass principle is applied to evaluate the source strength. The solid surfaces are discretized into a set of quadrilateral panel elements and the strengths of sources and dipoles are assumed constant at each panel. Applying this approximation to the boundary conditions leads to a set of simultaneous equations. Systematic numerical tests show that the present numerical method is fast and stable. In order to validate the present method, sample computations are carried out first for the case of a conventional axial flow fan which has a similar geometry as the waterjet propulsor, and then for the case of a waterjet propulsor on which experiments are carried out at KRISO(Korea Research Institute of Ships and Ocean Engineering).

  • PDF

Optimized Design of Air Controlling System in Air Defense Gun Systems of Wheeled Vehicle (차륜형 대공포의 냉방기 최적화 설계)

  • Jeon, Ki-Hyun;Lee, Boo-Hwan;Lee, Dong-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.11
    • /
    • pp.1047-1051
    • /
    • 2013
  • A modern combat vehicle needs to have a separate air-conditioning unit, although new combat systems tend to employ an integrated heating, cooling, and ventilating system. In this study, we investigated an air conditioning unit for an armored combat wheeled vehicle as a special use and military specification and performed a case study of a unique military combat vehicle. By using Fluent software, we tried to determine a suitable air ducting method and its location in the armored combat vehicle. The results show that an air-conditioning unit is one of the best solutions for wheeled vehicles that are not equipped with a cooling unit for their crews, and it can be applied to similar types of armored vehicles.

Design and Performance Analysis of Ring Stator for Crude Oil Carriers (원유운반선용 Ring Stator 설계 및 성능 연구)

  • Kang, Jin Gu;Byun, Tae Young;Kim, Moon Chan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.2
    • /
    • pp.369-376
    • /
    • 2021
  • The International Maritime Organization has developed the Energy Efficiency Design Index, an index related to carbon dioxide emissions, to enforce regulations on newly built ships. In this study, a new type of energy-saving device called the ring stator was used for 158k crude oil carriers, whose hull form was developed as a very thin after-body hull to reduce the resistance by delaying separation. The Energy-Saving Device (ESD) particularly involving the duct, is not adapted to the thin-after body hull form-like container ship. This new ring stator was developed considering these characteristics. A parametric study was conducted through Computational Fluid Dynamics (CFD) analysis using the Star-CCM+ program, and approximately 3.4 % improvement in propulsion efficiency was achieved. Further optimization investigations and experimental studies should be conducted in the future.

A Study on Regulation Improvement of Local Ventilation System (국소배기장치의 규제개선에 관한 연구)

  • kim, Nam Suk;Kim, Young Suk;Woo, In Sung
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.3
    • /
    • pp.74-83
    • /
    • 2018
  • Anyone who wants to install local ventilation system must obtain a permission from the Ministry of Employment and Labor even if he has permission from the Ministry of Environment. This is because not only the Atmospheric Environmental Protection Act, but also the manufacturing industry's hazardous risk prevention plan under Article 48 Clause 2 of the Industrial Safety and Health Act is to be submitted by 15 days before the construction. Under the current Environmental Protection Act, the Ministry of Environment regulates only the emission of pollutants from local exhaust ventilation systems into the atmosphere and the contents of workers' safety and health within industrial sites are managed by the Ministry of Employment and Labor. Even with the approval of the Ministry of Environment, the number of unsuccessful cases by the Ministry of Employment and Labor has increased, causing a growing discontent among the sites due to production delays and additional costs of improvement. In addition, local exhaust systems that are at greater risk of fire explosion have increased the risk of severe industrial accidents due to fire explosion. This is due to insufficient design of air volume, control speed, return speed, duct size, and risk of fire explosion. This is because the criteria and procedures for approval of local exhaust ventilation systems are similar, but the Industrial Safety and Health Act adds additional screening items for safety and safety of workers and fire and explosion. In this study, the Environment Ministry and the Employment and Labor Ministry seek to find a reasonable way to operate the system by comparing local exhaust ventilation system installation approval standards.