• Title/Summary/Keyword: 대형 건물

Search Result 331, Processing Time 0.024 seconds

Numerical Study on Air Egress Velocity in Vestibule Pressurization System : Damper Locationfor Uniform Air Egress Velocity in the case of Two Fire Doors (부속실 가압 시스템의 방연풍속에 관한 수치해석적 연구: 2개 출입문이 존재할 경우 균일한 방연풍속을 얻기 위한 댐퍼 위치 선정방법)

  • Seo, Chanwon;Shin, Weon Gyu
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.1-7
    • /
    • 2014
  • Vestibule pressurization system should produce uniform air egress velocity to prevent the intrusion of smoke into escape route when fire accidents occur inside a building and fire doors are open for evacuation of people. Air supplying units in the vestibule need to be arranged by taking account of the location of doors and the volume of the vestibule. In this study, computational fluid dynamics (CFD) simulations were conducted for the vestibule where two doors are installed varying the location of a damper and louver angle. From simulations, we found that when the damper in the vestibule is located at the center of the wall opposite to two fire doors, the uniform air egress velocity can be obtained.

Deregulation of the Fire Prevention Legislation; and Its Impact on Fire Occurrence - Case of the United Kingdom - (′화재예방법규′의 규제완화가 화재발생에 미치는 영향 -영국 사례분석 -)

  • 이재열
    • Fire Science and Engineering
    • /
    • v.15 no.2
    • /
    • pp.13-19
    • /
    • 2001
  • The OECD defines regulatory reform as both better regulation and deregulation, and emphasizes that governments must continue to regulate in areas such as environmental quality and safety. In contrast, Korean regulatory reform in fire services in the 1990s shows quite a strange trend, having been carried out only to the direction of softening and abolishing regulations. In the UK, fire prevention legislation has been strengthened since the enactment of the Fire Precautions Act 1971, and the Building Regulations 1991, which apply to all new buildings including a private house, require that there should be at least one smoke alarm on each floor. This research shows that the tightening of fire prevention legislation in the UK has promoted fire safety, which is very instructive for Korean fire services. In order for Korean fire services to protect citizens'lives and property from fires, one of basic directions of regulatory reform, to improve the quality of regulations relating to safety, health and the environment, should be observed strictly. Moreover, the flexibility of the basic direction of regulatory reform should be ensured so that the regulations concerning safety could be even increased under the overall reform strategy of reducing all regulations.

  • PDF

Integrated Command System for Firefight Satety in Special Disaster Area (특수재난현장 진압대원의 안전을 위한 통합 지휘시스템에 관한 연구)

  • Roh, Tae-Ho
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.98-108
    • /
    • 2015
  • An integrated command system is critical for the safety of firefighters and effective work in the headquarters of a special disaster areas such as natural disaster or large man-made hazard. The integrated command system requires environmental information such as temperature, humidity, and $CO_2$ levels, as well as personal physical information such as pulse and air respirator levels. An Analog to Digital Converter (ADC) chip converts sensed information into digital signals, and a Micro Controller Unit (MCU) transmits the digital signals to a transmission board using serial communication through a Serial Peripheral Interface (SPI). The digital signals are saved in a transmission board and transmitted to the integrated command system by a Radio Frequency (RF) unit. The location of fire-fighters in a building are determined using a gyro sensor and an inertial sensor. The collected information is applied to the integrated command system for firefighter safety and to ensure that they can effectively carry out their duties. Tthis study theoretically and experimentally investigated the technologies of RF transmission, indoor position, and an integrated command system that supports decision making using the transmitted information.

Flexural Capacity of Encased Composite Beam with Hollow Core PC Slabs (매입형 합성보의 휨 성능 평가 -속 빈 프리캐스트 콘크리트 슬래브와 비대칭 H형강 철골보-)

  • Heo, Byung Wook;Bae, Kyu Woong;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.5 s.72
    • /
    • pp.587-598
    • /
    • 2004
  • In this study, an experiment was conducted on the Slim Floor system, using a hollow core PC slab, which could reduce the over-all depth of a composite beam. The Slim Floor system is a method used in steel frame multi-story building construction, in which the structural depth of each floor is minimized after incorporating the steel floor beams within the depth of the concrete floor slab. This experimental study focused on the flexural behavior of the partially connected Slim Floor system with asymmetric steel beams encased in hollow core PC slabs. Ten full-scale specimens were constructed and tested in this study, with different steel beam heights, hollow core PC slabs, slab widths, and PC slab bearings. Observations made in line with the experiments indicated that the degree of shear connection without additional shear connection was 0.48-0.98 times more than that of the full shear connection, due to inherent mechanical and chemical bond stress.

Multiplexed Bend Loss Type Single-Mode Fiber-Optic Displacement Sensor Using Reflection Signals Generated at Optical Connectors (광커넥터의 반사를 이용한 다중화된 굽힘 손실형 단일모드 광섬유 변위센서)

  • Yoo Jung-Ae;Jo Jae Heung;Kwon Il-Bum
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.5
    • /
    • pp.415-422
    • /
    • 2004
  • We propose and present a new multiplexed bend loss type single-mode fiber-optic sensor system for displacement measurement in order to measure the displacement of several mm of civil engineering structures such as bridges and buildings. We make a bend loss type fiber-optic sensor for measuring displacements using the signal difference between two reflection signals due to various bend losses generating at a pair of optical connectors by using the optical time domain reflectometer. And we fabricate a multiplexed bend loss type fiber-optic sensor detecting linear displacements of 4 measuring positions of an object by setting these new 4 fiber-optic sensors on a single mode fiber simultaneously. We find that the multiplexed fiber-optics displacement sensor has linearity of 0.9942, maximum displacement of 6 mm, and accuracy of 6% for 4 measuring points.

A Study on the Possibility of using BIM in Automated Building Code Checking for Egress and Anti-disaster Regulations for Large-scale Buildings (BIM을 이용한 초대형 건축물 방재 및 피난 관련 법규 자동검토 가능성 연구)

  • Jeong, Ji-Yong;Lee, Ghang
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2008.11a
    • /
    • pp.690-693
    • /
    • 2008
  • Recently, the trend has been for buildings to become larger and more sophisticated, and this has created safety issues. Because the buildings are big it takes lots of time to check building codes related to anti-disaster and safety manually, and there is the high possibility of making mistakes. Due to these problems, according to a study, 83% of architecture and construction workers believe that an automated code-checking system is needed. This study researches past automated code checking systems and research activity, and using Building Information Model (BIM) technology, determines the feasibility of developing a system to automatically check domestic codes related to egress and anti-disaster. This paper describes the necessity of an automated building code checking system and expected effects. It then reports whether the methods used in previous studies can be deployed in domestic building code checking and discusses problems and limitations. It also suggests an alternative approach. Although this study covers limited codes related to egress, we need to find out what is needed for automatic general code checking system and do further studies for that.

  • PDF

Indoor Positioning System Using Fingerprinting Technique (Fingerprinting기법을 이용한 실내 위치측위시스템)

  • Nam, Doo-Hee;Han, Ho-Yeon
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.7 no.1
    • /
    • pp.1-9
    • /
    • 2008
  • According to the ubiquitous trend, the needs for the context based application service have been increased. These services take on Location Based Service which is based on the current location of users. It is widely used that localization techniques use GPS or ground wave and more efficient and accurate methods have been studied. Recently, not only services which targeted outdoor but also services which targeted indoor, for example home services and facility guidance of the building come into the spotlight. In case of the outdoor positioning area, COTH (Commercial Off-The-Shelf) has been released and used but relatively it doesn't produce an outcome in the indoor positioning area. Therefore, this paper Proposes the indoor positioning technique using wireless LAN (Local Area Network) which is one of the widely used wireless communication technique. It analyzes the typical WLAN location positioning methodology has been studied and their advantage and disadvantage also suggests how to design and implement the specific WLAN positioning system. In addition, it suggests new methods that progress the accuracy of the existing systems and improve the efficient computation.

  • PDF

Automatic Door System Performance Improvement Study by the disturbance compensation (외란보상을 통한 자동문 시스템 성능 개선연구)

  • Park, Won-Hyeon;Kim, Min;Jeong, Jae-Hoon;Lee, Dong Heon;Choi, Myoung Hoon;Lim, Jae Jun;Byun, Gi-Sik;Kim, Gwan-Hyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.734-736
    • /
    • 2016
  • Doors are in various buildings, such as large retail stores, hospitals, restaurants, government offices and is used as a door to provide convenience for customers, the convenience of security to control doors and exterior access Castle, etc. In the case of housing door facilities It has been used widely. However, the conventional automatic door controller Although the primary use of the PID control, the contact size and weight depending on the location to cause an instability in the system controller or the like, and disturbance of parameter variation and uncertain dynamics because of the wide variations. In this paper, we design a robust controller to compensate for uncertainties and to compensate for the disturbance.

  • PDF

Intelligent evacuation systems considering bottleneck (병목 현상을 고려한 지능형 대피유도 시스템)

  • Kim, Ryul;Joo, Yang-ick
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.69-70
    • /
    • 2017
  • As the industry develops, the size of buildings and ships are getting bigger and more complicated. In such a complex space, emergency evacuation systems are required because of the possibility of casualties when an accident situation occurs. However, because present systems are composed of basic devices, such as alarms, emergency exit signs, and announcement regarding the situation and inform only the least information to evacuees, evacuees are not able to judge objectively. To solve these problems, various evacuation algorithms have been proposed. However, these studies aim to search evacuation routes based on specific risk factors or to model the effects of bottlenecks in evacuation situations. Therefore, there is a limit to apply to real systems. Therefore, we propose algorithms to search the optimal evacuation route considering various risk factors such as fire and bottleneck in evacuation situations and to be applicable in actual situation in this paper. Performance evaluation using computer simulations showed that the proposed scheme is effective.

  • PDF

Design and Implementation of a Real-time Automatic Disaster and Information Broadcasting System (시뮬레이션 프로그램 기반 실시간 자동재난 및 안내방송시스템의 설계)

  • Lee, Byung-Mun;Park, Jung-In;Kang, Un-Gu
    • Journal of Digital Convergence
    • /
    • v.10 no.7
    • /
    • pp.141-152
    • /
    • 2012
  • The typical evacuation guidance system based on fire detectors, which is being widely used in theaters and large buildings, is often operated in an analog manner. In case of fire, it often causes the system to lose a wired line or wireless fire detection sensor, resulting in the difficulty of transmitting signals from a wired or wireless fire detection sensor to the main fire monitoring device. Accordingly, this paper has proposed the broadcasting system for disaster management, having an efficient evacuation guidance plan when a disaster occurs. The system reacts to an emergency situation along with fire alarm sirens in real time. We have implemented the above system by means of a simulation program that prints the evacuation guidance information (e.g., location and time of fire, and evacuation path) on an LCD located in a building through the fire sensor network in case of an emergency (e.g., actual fire). We have developed the simulation system by using mathematical algorithms, such as the optimal path search and the fire smoke diffusion algorithm. This simulation program considers the structure of a building and the location where the fire has initially occurred, applying it to the simulator.