• Title/Summary/Keyword: 대한핵의학회

Search Result 3,358, Processing Time 0.041 seconds

Diagnostic Accuracy of $^{99m}Tc$-DISIDA Scintigraphy in Biliary Atresia (선천성 담도폐쇄증에서 $^{99m}Tc$ DISIDA 신티그라피의 진단정확성)

  • Hyun, In-Young;Lee, Dong-Soo;Lee, Kyung-Han;Kim, Jong-Ho;Chung, June-Key;Suh, Jung-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.3
    • /
    • pp.357-363
    • /
    • 1994
  • We evaluated the diagnostic accuracy of $^{99m}Tc$-DISIDA scintigrauhy as a mean of differentiating biliary atresia from neonatal hepatitis. $^{99m}Tc$-DISIDA scintigraphy was visually interpreted by assessing the presence or absence of radioactivity in the intestine or gall bladder. In patients without intestinal radioactivity, we measured the hepatic retention index and the hepatic uptake index. The hepatic retention Index was expressed as the amount of change of liver activity from 5 minutes to 30 minutes postinjection. The hepatic uptake Index was graded visually with 5 minute images using the following scoring scheme : grade 0(normal hepatic uptake), grade 1(decreased hepatic uptake), grade 2(hepatic uptake equal to cardiac uptake), and grade 3(hepatic uptake less than cardiac uptake). Age, total bilirubin, and hepatic uptake index were compared between the biliary atresia and the neonatal hepatitis group, between neonatal hepatitis patients with and without intestinal radioactivity, and between the biliary atresia and neonatal hepatitis patients with absent intestinal radioactivity. The results were as follows ; 1) None of the 30 biliary atresia patients showed intestinal radioactivity, while 31/40 neonatal hepatitis patients showed intestinal radioactivity. The sensitivity, specificity, and accuracy of the presence of intestinal radioactivity ?or the diagnosis of biliary atresia was 100%, 78%, and 87%, respectively. 2) In patients with absent intestinal radioactivity the mean hepatic retention index was $1.5{\pm}0.6$ in the 16 biliary atresia patients, and $1.1{\pm}0.2$ in the 7 neonatal hepatitis patients(p<0.01). All 7 patients with hepatic retention index over 1.5 had biliary atresia. But there were 9 patients with biliary atresia below 1.5. 3) No significant differences were found in age, total bilirubin, or hepatic uptake Index between biliary atresia and neonatal hepatitis patients. However there were differences in age, total bilirubin, and hepatic uptake index between neonatal hepatitis patients with and without intestinal radioactivity. The hepatic uptake index was significantly lower, age was old, and total bilirubin was low in the group with intestinal radioactivity compared the group without intestinal radioactivity(p<0.05). Relation between total bilirubin and the hepatic uptake index was that total bilirubin was relatively low at normal hepatic uptake index in biliary atresia and neonatal hepatitis patients. 4) When hepatic uptake index and hepatic retention index were high it suggest that biliary atresia is more likely, considered relation between hepatic uptake Index and the hepatic retention index. Thus, we conclude that $^{99m}Tc$-DISIDA scintigraphy is accurate in the differential diagnosis of biliary atresia and neonatal hepatitis. In patients without intestinal radioactivity, the hepatic retention index and hepatic uptake index, along with the patient's age and total bilirubin level may supplement diagnosis and improve diagnostic accuracy.

  • PDF

Comparison of Batch Assay and Random Assay Using Automatic Dispenser in Radioimmunoassay (핵의학 체외 검사에서 자동분주기를 이용한 Random Assay 가능성평가)

  • Moon, Seung-Hwan;Lee, Ho-Young;Shin, Sun-Young;Min, Gyeong-Sun;Lee, Hyun-Joo;Jang, Su-Jin;Kang, Ji-Yeon;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.4
    • /
    • pp.323-329
    • /
    • 2009
  • Purpose: Radioimmunoassay (RIA) was usually performed by the batch assay. To improve the efficiency of RIA without increase of the cost and time, random assay could be a choice. We investigated the possibility of the random assay using automatic dispenser by assessing the agreement between batch assay and random assay. Materials and Methods: The experiments were performed with four items; Triiodothyronine (T3), free thyroxine (fT4), Prostate specific antigen (PSA), Carcinoembryonic antigen (CEA). In each item, the sera of twenty patients, the standard, and the control samples were used. The measurements were done 4 times with 3 hour time intervals by random assay and batch assay. The coefficient of variation (CV) of the standard samples and patients' data in T3, fT4, PSA, and CEA were assessed. ICC (Intraclass correlation coefficient) and coefficient of correlation were measured to assessing the agreement between two methods. Results: The CVs (%) of T3, fT4, PSA, and CEA measured by batch assay were 3.2$\pm$1.7%, 3.9$\pm$2.1%, 7.1$\pm$6.2%, 11.2$\pm$7.2%. The CVs by random assay were 2.1$\pm$1.7%, 4.8$\pm$3.1%, 3.6$\pm$4.8%, and 7.4$\pm$6.2%. The ICC between the batch assay and random assay were 0.9968 (T3), 0.9973 (fT4), 0.9996 (PSA), and 0.9901 (CEA). The coefficient of correlation between the batch assay and random assay were 0.9924(T3), 0.9974 (fT4), 0.9994 (PSA), and 0.9989 (CEA) (p<0.05). Conclusion: The results of random assay showed strong agreement with the batch assay in a day. These results suggest that random assay using automatic dispenser could be used in radioimmunoassay.

Development of Formulas for the Estimation of Renal Depth and Application in the Measurement of Glomerular Filtration Rate in Koreans (사구체 여과율 측정을 위한 한국인의 신장 깊이에 관한 방정식 도출과 이용)

  • Yoo, Ie-Ryung;Kim, Sung-Hoon;Chung, Yong-An;Jung, Hyun-Seok;Lee, Hae-Giu;Park, Young-Ha;Lee, Sung-Yong;Sohn, Hyung-Seon;Chung, Soo-Kyo;Kim, Hyun-Mi;Lee, Hyung-Goo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.5
    • /
    • pp.418-425
    • /
    • 2000
  • Purpose: There is no established formula for estimating renal depths in Korean. As a result, we undertook this study to develop a new formula, and to apply this formula in the calculation of glomerular filtration rate (GFR). Materials and Methods: We measured the renal depth (RD) on the abdominal CT obtained in 300 adults (M:F: 167:133, mean age 50.9 years) without known renal diseases. The RDs measured by CT were compared with the estimated RDs based on the Tonnesen and Taylor equations. New formulas were derived from the measured RDs in 200 out of 300 patients based on several variables such as sex, age, weight, and height by multiple regression analysis. The RDs estimated from the new formulas were compared with the measured RDs in the remaining 100 patients as a control. In 48 patients who underwent Tc-99m DTPA renal scintigraphy, GFR was measured with three equations (new formula, Tonnesen and Taylor equations), respectively, and compared with each other. Results: The mean values of the RDs measured from CT were 6.9 cm for right kidney of the men (MRK), 6.7 cm for left kidney of the men (MLK), 6.7 cm for right kidney of the women (WRK), and 6.6 cm for left kidney of the women (WLK). The RDs estimated from Tonnesen equation were shorter than the ones measured from CT significantly. The newly derived formulas were 12.813 (weight/height)+0.002 (age)+ 2.264 for MRK, 15.344 (weight/height)+0.011 (age)+0.557 for MLK, 12.936 (weight/height)+ 0.014 (age)+1.462 for WRK and 13.488 (weight/height)+0.019 (age)+0.762 for WLK. The correlation coefficients of the RD measured from CT and estimated from the new formula were 0.529 in MRK, 0.729 in MLK, 0.601 in WRK, and 0.724 in WLK, respectively. The GFRs from the new formula were significantly higher than those from the Tonnesen equation significantly, which was the most similar to normal GFR values. Conclusion: We generated new formulas for estimating RD in Korean from the data by CT. By adopting these formulas, we expect that GFR can be measured by the Gates method accurately in Korean.

  • PDF

Prediction of Salvaged Myocardium in Patients with Acute Myocardial Infarction after Primary Percutaneous Coronary Angioplasty using early Thallium-201 Redistribution Myocardial Perfusion Imaging (급성심근경색증의 일차적 관동맥성형술 후 조기 Tl-201 재분포영상을 이용한 구조심근 예측)

  • Choi, Joon-Young;Yang, You-Jung;Choi, Seung-Jin;Yeo, Jeong-Seok;Park, Seong-Wook;Song, Jae-Kwan;Moon, Dae-Hyuk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.4
    • /
    • pp.219-228
    • /
    • 2003
  • Purpose: The amount of salvaged myocardium is an important prognostic factor in patients with acute myocardial infarction (MI). We investigated if early Tl-201 SPECT imaging could be used to predict the salvaged myocardium and functional recovery in acute MI after primary PTCA. Materials and Methods: In 36 patients with first acute MI treated with primary PTCA, serial echocardiography and Tl-201 SPECT imaging ($5.8{\pm}2.1$ days after PTDA) were performed. Regional wall motion and perfusion were quantified with on 16-segment myocardial model with 5-point and 4-point scaling system, respectively. Results: Wall motion was improved in 78 of the 212 dyssynergic segments on 1 month follow-up echocardiography and 97 on 7 months follow-up echocardiography, which were proved to be salvaged myocardium. The areas under receiver operating characteristic curves of Tl-201 perfusion score for detecting salvaged myocardial segments were 0.79 for 1 month follow-up and 0.83 for 7 months follow-up. The sensitivity and specificity of Tl-201 redistribution images with optimum cutoff of 40% of peak thallium activity for detecting salvaged myocardium were 84.6% and 55.2% for 1 month follow-up, and 87.6% and 64.3% for 7 months follow-up, respectively. There was a linear relationship between the percentage of peak thallium activity on early redistribution imaging and the likelihood of segmental functional improvement 7 months after reperfusion. Conclusion: Tl-201 myocardial perfusion SPECT imaging performed early within 10 days after reperfusion can be used to predict the salvaged myocardium and functional recovery with high sensitivity during the 7 months following primary PTCA in patients with acute MI.

Serial Changes of Serum Thyroid-Stimulating Hormone after Total Thyroidectomy or Withdrawal of Suppressive Thyroxine Therapy in Patients with Differentiated Thyroid Cancer (분화성 갑상선 암 환자에서 갑상선 전절제술후 또는 갑상선 호르몬 억제 요법 중단에 따른 갑상선 자극호르몬의 변화)

  • Bae, Jin-Ho;Lee, Jae-Tae;Seo, Ji-Hyoung;Jeong, Shin-Young;Jung, Jin-Hyang;Park, Ho-Yong;Kim, Jung-Guk;Ahn, Byeong-Cheol;Sohn, Jin-Ho;Kim, Bo-Wan;Park, June-Sik;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.6
    • /
    • pp.516-521
    • /
    • 2004
  • Background: Radioactive iodine (RAI) therapy and whole-body scanning are the fundamentals of treatment and follow-up of patients with differentiated thyroid cancer. It is generally accepted that a Thyroid-Stimulating Hormone (TSH) level of at least 30 ${\mu}U/ml$ is a prerequisite for the effective use of RAI, and that it requires 4-6 weeks of off-thyroxine to attain these levels. Because thyroxine withdrawal and the consequent hypothyroidism are often poorly tolerated, and occasionally might be hazardous, it is important to be certain that these assumptions are correct. We have measured serial changes in serum TSH after total thyroidectomy or withdrawl of thyroxine in patients with thyroid cancer. Subjects and Methods: Serum TSH levels were measured weekly after thyroidectomy in 10 patients (group A) and after the discontinuation of thyroxine in 12 patients (group B). Symptoms and signs of hypothyroidism were also evaluated weekly by modified Billewicz diagnostic index. Results: By the second week, 78% of group A patients and 17% of group B patients had serum TSH levels ${\geq}30{\mu}U/ml$. By the third week, 89% of group A patients and 90% of group B patients had serum TSH levels ${\geq}30{\mu}U/ml$. By the fourth week, all patients in two groups achieved target TSH levels and there were no overt hypothyroidism. Conclusion: in all patients, serum TSH elevated to the target concentration (${\geq}30{\mu}U/ml$) within 4 weeks without significant manifestation of hypothyroidism. The schedule of RAI administration could be adjusted to fit the needs and circumstances of individual patients with a shorter preparation period than the conventional.

Determination of Therapeutic Dose of I-131 for First High Dose Radioiodine Therapy in Patients with Differentiated Thyroid Cancer: Comparison of Usefulness between Pathological Staging, Serum Thyroglobulin Level and Finding of I-123 Whole Body Scan (분화 갑상선암 수술 후 최초 고용량 방사성옥소 치료시 투여용량 결정: 병리적 병기, 혈청 갑상선글로불린치와 I-123 전신 스캔의 유용성 비교)

  • Jeong, Hwan-Jeong;Lim, Seok-Tae;Youn, Hyun-Jo;Sohn, Myung-Hee
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.4
    • /
    • pp.301-306
    • /
    • 2008
  • Purpose: Recently, a number of patients needed total thyroidectomy and high dose radioiodine therapy (HD-RAI) get increased more. The aim of this study is to evaluate whether pathological staging (PS) and serum thyroglobulin (sTG) level could replace the diagnostic I-123 scan for the determination of therapeutic dose of HD-RAI in patients with differentiated thyroid cancer. Materials and Methods: Fifty eight patients (M:F=13;45, age $44.5{\pm}11.5\;yrs$) who underwent total thyroidectomy and central or regional lymph node dissection due to differentiated thyroid cancer were enrolled. Diagnostic scan of I-123 and sTG assay were also performed on off state of thyroid hormone. The therapeutic doses of I-131 (TD) were determined by the extent of uptakes on diagnostic I-123 scan as a gold standard. PS was graded by the criteria recommended in 6th edition of AJCC cancer staging manual except consideration of age. For comparison of the determination of therapeutic doses, PS and sTG were compared with the results of I-123 scan. Results: All patients were underwent HD-RAI. Among them, five patients (8.6%) were treated with 100 mCi of I-131, fourty three (74.1%) with 150 mCi, six (10.3%) with 180 mCi, three (5.2%) with 200 mCi, and one (1.7%) with 250 mCi, respectively. On the assessment of PS, average TDs were $154{\pm}25\;mCi$ in stage I (n=9), $175{\pm}50\;mCi$ in stage II (n=4), $149{\pm}21\;mCi$ in stage III (n=38), and $161{\pm}20\;mCi$ in stage IV (n=7). The statistical significance was not shown between PS and TD (p=0.169). Among fifty two patients who had available sTG, 25 patients (48.1%) having below 2 ng/mL of sTG were treated with $149{\pm}26\;mCi$ of I-131, 9 patients (17.3%) having $2{\leq}\;sTG\;<5\;ng/mL$ with $156{\pm}17\;mCi$, 5 patients (9.6%) having $5{\leq}\;sTG\;<10\;ng/mL$ with $156{\pm}13\;mCi$, 7 patients (13.5%) having $10{\leq}sTG\;<50\;ng/mL$ with $147{\pm}24\;mCi$, and 6 patients (11.5%) having above 50 ng/mL with $175{\pm}42\;mCi$. The statistical significance between sTG level and TD (p=0.252) was not shown. Conclusion: In conclusion, PS and sTG could not replace the determination of TD using I-123 scan for first HD-RAI in patients with differentiated thyroid cancer.

Assessment of Cerebral Hemodynamic Changes in Pediatric Patients with Moyamoya Disease Using Probabilistic Maps on Analysis of Basal/Acetazolamide Stress Brain Perfusion SPECT (소아 모야모야병에서 뇌확률지도를 이용한 수술전후 혈역학적 변화 분석)

  • Lee, Ho-Young;Lee, Jae-Sung;Kim, Seung-Ki;Wang, Kyu-Chang;Cho, Byung-Kyu;Chung, June-Key;Lee, Myung-Chul;Lee, Dong-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.3
    • /
    • pp.192-200
    • /
    • 2008
  • To evaluate the hemodynamic changes and the predictive factors of the clinical outcome in pediatric patients with moyamoya disease, we analyzed pre/post basal/acetazolamide stress brain perfusion SPECT with automated volume of interest (VOIs) method. Methods: Total fifty six (M:F = 33:24, age $6.7{\pm}3.2$ years) pediatric patients with moyamoya disease, who underwent basal/acetazolamide stress brain perfusion SPECT within 6 before and after revascularization surgery (encephalo-duro-arterio-synangiosis (EDAS) with frontal encephalo-galeo-synangiosis (EGS) and EDAS only followed on contralateral hemisphere), and followed-up more than 6 months after post-operative SPECT, were included. A mean follow-up period after post-operative SPECT was $33{\pm}21$ months. Each patient's SPECT image was spatially normalized to Korean template with the SPM2. For the regional count normalization, the count of pons was used as a reference region. The basal/acetazolamide-stressed cerebral blood flow (CBF), the cerebral vascular reserve index (CVRI), and the extent of area with significantly decreased basal/acetazolamide- stressed rCBF than age-matched normal control were evaluated on both medial frontal, frontal, parietal, occipital lobes, and whole brain in each patient's images. The post-operative clinical outcome was assigned as good, poor according to the presence of transient ischemic attacks and/or fixed neurological deficits by pediatric neurosurgeon. Results: In a paired t-test, basal/acetazolamide-stressed rCBF and the CVRI were significantly improved after revascularization (p<0.05). The significant difference in the pre-operative basal/acetazolamide-stressed rCBF and the CVRI between the hemispheres where EDAS with frontal EGS was performed and their contralateral counterparts where EDAS only was done disappeared after operation (p<0.05). In an independent student t-test, the pre-operative basal rCBF in the medial frontal gyrus, the post-operative CVRI in the frontal lobe and the parietal lobe of the hemispheres with EDAS and frontal EGS, the post-operative CVRI, and ${\Delta}CVRI$ showed a significant difference between patients with a good and poor clinical outcome (p<0.05). In a multivariate logistic regression analysis, the ${\Delta}CVRI$ and the post-operative CVRI of medial frontal gyrus on the hemispheres where EDAS with frontal EGS was performed were the significant predictive factors for the clinical outcome (p =0.002, p =0.015), Conclusion: With probabilistic map, we could objectively evaluate pre/post-operative hemodynamic changes of pediatric patients with moyamoya disease. Specifically the post-operative CVRI and the post-operative CVRI of medial frontal gyrus where EDAS with frontal EGS was done were the significant predictive factors for further clinical outcomes.

Small Animal PET Imaging with [$^{124}I$]FIAU for Herpes Simplex Virus Type 1 Thymidine Kinase Gene Expression in a Hepatoma Model (간암 동물 모델에서 2'-fluoro-2'-deoxy-1-${\beta}$-D-arabinofuranosyl-5-[$^{124}I$iodo-uracil ($[^{124}I]FIAU$) 소동물 PET 영상 연구)

  • Chae, Min-Jeong;Lee, Tae-Sup;Kim, June-Youp;Woo, Gwang-Sun;Jumg, Wee-Sup;Chun, Kwon-Soo;Kim, Jae-Hong;Lee, Ji-Sup;Ryu, Jin-Sook;Cheon, Gi-Jeong;Choi, Chang-Woon;Lim, Sang-Moo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.3
    • /
    • pp.235-245
    • /
    • 2008
  • Purpose: The HSV1-tk gene has been extensively studied as a type of reporter gene. In hepatocellular carcinoma (HCC), only a small proportion of patients are eligible for surgical resection and there is limitation in palliative options. Therefore, there is a need for the development of new treatment modalities and gene therapy is a leading candidate. In the present study, we investigated the usefulness of substrate, 2'-fluoro-2'-deoxy-1-${\beta}$-D-arabino-furanosyi-5-[$^{124/125}I$]iodo- uracil ([$I^{124/125}I$]FIAU) as a non-invasive imaging agent for HSV1-tk gene therapy in hepatoma model using small animal PET. Material and Methods: With the Morris hepatoma MCA cell line and MCA-tk cell line which was transduced with the HSV1-tk gene, in vitro uptake and correlation study between [$^{125}I$]FIAU uptake according to increasing numeric count of percentage of MCA-tk cell were performed. The biodistribution data and small animal PET images with [$^{124}I$]FIAU were obtained with Balb/c-nude mice bearing both MCA and MCA-tk tumors. Results:, Specific accumulation of [[$^{125}I$]FIAU was observed in MCA-tk cells but uptake was low in MCA cells. Uptake in MCA-tk cells was 15 times higher than that of MCA cells at 480 min. [$^{125}I$]FIAU uptake was linearly correlated (R2 =0.964, p =0.01) with increasing percentage of MCA-tk numeric cell count. Biodistribution results showed that [$^{125}I$]FIAU was mainly excreted via the renal system in the early phase. Ratios of MCA-tk tumor to blood acting were 10, 41, and 641 at 1 h, 4 h, and 24 h post-injection, respectively. The maximum ratio of MCA-tk to MCA tumor was 192.7 at 24 h. Ratios of MCA-tk tumor to liver were 13.8, 66.8, and 588.3 at 1 h, 4 h, and 24 h, respectively. On small animal PET, [$^{124}I$]FIAU accumulated in substantial higher levels in MCA-tk tumor and liver than MCA tumor. Conclusion: FIAU shows selective accumulation to HSV1-tk expressing hepatoma cell tumors with minimal uptake in normal liver. Therefore, radiolabelled FIAU is expected to be a useful substrate for non-invasive imaging of HSV1-tk gene therapy and therapeutic response monitoring of HCC.

A Study on the Individual Radiation Exposure of Medical Facility Nuclear Workers by Job (의료기관 핵의학 종사자의 직무 별 개인피폭선량에 관한 연구)

  • Kang, Chun-Goo;Oh, Ki-Baek;Park, Hoon-Hee;Oh, Shin-Hyun;Park, Min-Soo;Kim, Jung-Yul;Lee, Jin-Kyu;Na, Soo-Kyung;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.9-16
    • /
    • 2010
  • Purpose: With increasing medical use of radiation and radioactive isotopes, there is a need to better manage the risk of radiation exposure. This study aims to grasp and analyze the individual radiation exposure situations of radiation-related workers in a medical facility by specific job, in order to instill awareness of radiation danger and to assist in safety and radiation exposure management for such workers. Materials and Methods: 1 January 2007 to 31 December 2009 to work in medical institutions are classified as radiation workers Nuclear personal radiation dosimeter regularly, continuously administered survey of 40 workers in three years of occupation to target, Imaging Unit beautifully, age, dose sector, job function-related tasks to identify the average annual dose for a deep dose, respectively, were analyzed. The frequency analysis and ANOVA analysis was performed. Results: Imaging Unit beautifully three years the annual dose PET and PET/CT in the work room 11.06~12.62 mSv dose showed the highest, gamma camera injection room 11.72 mSv with a higher average annual dose of occupation by the clinical technicians 8.92 mSv the highest, radiological 7.50 mSv, a nurse 2.61 mSv, the researchers 0.69 mSv, received 0.48 mSv, 0.35 mSv doctors orderly, and detail work employed the average annual dose of the PET and PET/CT work is 12.09 mSv showed the highest radiation dose, gamma camera injection work the 11.72 mSv, gamma camera imaging work 4.92 mSv, treatment and safety management and 2.98 mSv, a nurse working 2.96 mSv, management of 1.72 mSv, work image analysis 0.92 mSv, reading task 0.54 mSv, with receiving 0.51 mSv, 0.29 mSv research work, respectively. Dose sector average annual dose of the study subjects, 15 people (37.5%) than the 1 mSv dose distribution and 5 people (12.5%) and 1.01~5.0 mSv with the dose distribution was less than, 5.01~10.0 mSv in the 14 people (35.0%), 10.01~20.0 mSv in the 6 people (15.0%) of the distribution were analyzed. The average annual dose according to age in occupations that radiological workers 25~34 years old have the highest average of 8.69 mSv dose showed the average annual dose of tenure of 5~9 years in jobs radiation workers in the 9.5 mSv The average was the highest dose. Conclusion: These results suggest that medical radiation workers working in Nuclear Medicine radiation safety management of the majority of the current were carried out in the effectiveness, depending on job characteristics has been found that many differences. However, this requires efforts to minimize radiation exposure, and systematic training for them and for reasonable radiation exposure management system is needed.

  • PDF

A Study on the Determination of Scan Speed in Whole Body Bone Scan Applying Oncoflash (Oncoflash를 적용한 전신 뼈 영상 검사의 스캔 속도 결정에 관한 연구)

  • Yang, Gwang-Gil;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.56-60
    • /
    • 2009
  • Purpose: The various studies and efforts to develop program are in progress in the field of nuclear medicine for the purpose of reducing scan time. The Oncoflash is one of the programs used in whole body bone scan which allows to maintain the image quality while to reduce scan time. When Those applications are used in clinical setting, both the image quality and reduction of scan time should be considered, therefore, the purpose of this study was to determine the criteria for proper scan speed. Materials and Methods: The subjects of this study were the patients who underwent whole body bone scan at the departments of nuclear medicine in the Asan Medical Center located in Seoul from 1st to 10th, July, 2008. The whole body bone images obtained in the scan speed of 30cm/min were classified by the total counts into under 800 K, and over 800 K, 900 K, 1,000 K, 1,500 K, and 2,000 K. The image quality were assessed qualitatively and the percentages of those of 1,000K and under of total counts were calculated. The FWHM before and after applying the Oncoflash were analyzed using images obtained in $^{99m}Tc$ Flood and 4-Quadrant bar phantom in order to compare the resolution according to the amount of total counts by the application of the Oncoflash. Considering the counts of the whole body bone scan, the dosed 2~5 mCi were used. 152 patients underwent the measurement in which the counts of Patient Postioning Monitor (PPM) were measured with including head and the parts of chest which the starting point of whole body bone scan from 7th to 26th, August, 2008. The correlations with total counts obtained in the scan speed of 30cm/min among them were analyzed (The exclusion criteria were after over six hours of applying isotopes or low amount of doses). Results: The percentage of the whole body bone image which has the geometric average of total counts of under 1,000K among them obtained in the scan speed of 30cm/min were 17.6%(n=58) of 329 patients. The qualitative analysis of the image groups according to the whole body counts showed that the images of under 1,000K were assessed to have coarse particles and increased noises. The analysis on the FWHM of the images before and after applying the Oncoflash showed that, in the case of PPM counts of under 3.6 K, FWHM values after applying the Oncoflash were higher than that before applying the Oncoflash, whereas, in the case of that of over 3.6 K, the FWHM after applying the Oncoflash were not higher than that before applying the Oncoflash. The average of total counts at 2.5~3.0 K, 3.1~3.5 K, 3.6~4.0 k, 4.1~4.5 K, 4.6~5.0 K, 5.1~6.0 K, 6.1~7.0 K, and 7.1 K over (in PPM) were $965{\pm}173\;K$, $1084{\pm}154\;K$, $1242{\pm}186\;K$, $1359{\pm}170\;K$, $1405{\pm}184\;K$, $1640{\pm}376\;K$, $1,771{\pm}324\;K$, and $1,972{\pm}385\;K$, respectively and the correlations between the counts in PPM and the total counts of image obtained in the scan speed of 30 cm/min demonstrated strong correlation (r=.775, p<.01). Conclusions: In the case of PPM coefficient over 3.6 K, the image quality obtained in the scan speed of 30cm/min and after applying the Oncoflash was similar to that obtained in the scan speed of 15 cm/min. In the case of total counts over 1,000 K, it is expected to reduce scan time without any damage on the image quality. In the case of total counts under 1,000 K, however, the image quality were decreased even though the Oncoflash is applied, so it is recommended to perform the re-image in the scan speed of 15 cm/min.

  • PDF