• Title/Summary/Keyword: 대퇴 간섭 나사

Search Result 13, Processing Time 0.02 seconds

Removal of a Femoral Interference Screw that Migrated Posteriorly after ACL Reconstruction, Using Posterior Trans-septal Portal - A Case Report - (전방 십자 인대 재건술 후 후방으로 전위된 대퇴 간섭 나사의 후방 경격막 도달법을 이용한 제거 - 증례 보고 -)

  • Ahn, Jin-Hwan;Lee, Sang-Hak;Ha, Hae-Chan
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.2
    • /
    • pp.187-191
    • /
    • 2006
  • Few cases have been reported in which the femoral interference screw has migrated into the posterior compartment after an ACL reconstruction. It usually requires removal, because it leads usually to mechanical symptom. However, the arthroscopic removal of a screw is a technically demanding procedure, especially in the case of an intact integrated ACL graft or one that is encapsulated around the screw. We present a case in which a displaced femoral interference screw migrated within the posterior compartment 11 years postoperatively, after the graft had been successfully incorporated at the femoral site and showed good continuity on MRI and arthroscopic examination. Although it is often technically challenging, through the use of a posterior trans-septal portal, we can successfully remove a displaced femoral interference screw even in the most difficult locations in the posterior compartment without damage to ACL graft.

  • PDF

Cross-Pin and Interference Screw Femoral Fixation in Anterior Cruciate Ligament Reconstruction using Hamstring Tendon -Technical Note- (슬괵건을 이용한 전방십자인대 재건술시 횡고정 핀과 간섭나사를 이용한 대퇴터널 고정술 -수술 수기-)

  • In Yong;Bahk Won-Jong;Park Jong-Beom;Hong Seung-Hwan
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.1
    • /
    • pp.60-63
    • /
    • 2002
  • Purpose : The purpose of this study was to introduce new femoral fixation technique using a cross-pin and a bioabsorbable interference screw in hamstring ACL reconstruction. Method : Semitendinosus and gracilis were harvested for quadrapled graft. After tibial tunnel had been made, femoral tunnel was made 35 mm in depth. Then the graft passed through the tunnels. Cross-pin was fixed through the drill hole which had been made through upper sleeve of the Rigidfix system. While pulling the graft, bioabsorbable interference screw was fixed through the anteromedial portal. Conclusion : We introduced the new femoral fixation technique using a cross-pin and a bioabsorbable interference screw as a good method with high fixation strength and tight graft-bone contact.

  • PDF

The Delayed Inflammatory Reaction after Anterior Cruciate Lligament Reconstruction with a Bioabsorbable Interference Screw Fixation - A Case Report - (생분해성 간섭나사를 이용한 전방십자인대 재건술 후 발생한 지연성 염증반응 - 증례 보고 -)

  • Lim, Hong-Chul;Noh, Kyoung-Sun;Yang, Jae-Hyuk
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.1
    • /
    • pp.87-90
    • /
    • 2006
  • The complication caused by a bioabsorbable interference screw is rare after anterior cruciate ligament reconstruction. We report a case of delayed inflammatory reaction at the tibial tunnel and femoral tunnel where the graft tendon had been fixed with a bioabsorbable interference screw ($Bioscrew^{(R)}$) for anterior cruciate ligament reconstruction using bone-patellar tendon-bone autograft.

  • PDF

Comparison of Results of ACL Reconstruction According to the Fixation Materials (Metal & Bioabsorbable Interference Screw and RIGIDfix) (금속, 흡수성 간섭 나사못 및 RIGIDfix를 이용한 전방 십자 인대 재건술의 결과 비교)

  • Lim Hong Chul;Wang Joon Ho;Rho Young Jin;Hwang Jin Ho
    • Journal of the Korean Arthroscopy Society
    • /
    • v.7 no.2
    • /
    • pp.206-214
    • /
    • 2003
  • Purpose : To analysis each clinical results after arthroscopic ACL reconstruction with using variable fixatives which are metallic and bioabsorbable interference screw, and RIGIDfix. Therefore, We reported the clinical reliability and safty of ACL reconstruction using RIGIDfix. Materials and Methods : We evaluated the results of arthroscopic ACL resconstruction with patellar tendon autograft among three groups, of which group 1 is used metal interference screw for 44 patients, group 2 used bioabsorbable interference screw for 47 patients, group 3 used RIGIDfix for 42 patients. We compared the clinical results by physical examination (anterior drawer test, Lachman test and pivot shift test), Lysholm score and KT-2000 arthrometer and compared the radiological results by measurement of tunnel and fixatives position and widening and by MRI findings. We analyzed the results by SAS 8.2 Ducan. Tukey and paired t-test Results : Physical instability was in 5 cases, which group 2 had 4 cases and group 3 had 1 case. Lysholm score improved from 59.8. 64.4, 61 to 90.1, 92.3. 92. KT-2000 arthrometer instability improved from 9.20, 10.2, 9.5 to 1.43. 1.62. 2.00 (p=0.478). Radiologically, all cases had excellent tunnel position and cyst change was observed the 8 cases in the group 2, but, all 20 cases 2nd MRI had signal change of peri-fixatives. But, no correlation of clinical results. Conclusion : No statistical difference of clinical instability was found among three groups. And femoral tunnel changes were much observed in group I, II than III. We considered the RIGIDfix has much advantages because the short operation time, better fixation position and much bone contact surface. But, further long term follow up study was needed.

  • PDF

The Effect of Cyclic Load on Different Femoral Fixation Techniques in Anterior Cruciate Ligament Reconstruction (전방십자인대 재건시 이식건의 대퇴골측 고정에 대한 주기성인장부하의 효과)

  • Song Eun-Kyoo;Kim Jong Seok
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.2 no.1
    • /
    • pp.28-36
    • /
    • 2003
  • Purpose: To determine and to compare the effects of cyclic loading on the fixation strength of different femoral fixation methods in ACL reconstruction. Materials and Methods: Biomechanical test using an Instron(R) machine (Model No.5569. Mass, U.S.A) were carried out to compare the pull out strength of six different femoral fixation techniques after a cyclic loading in 72 Yorkshire pig knees. The graft-bone complex was cyclically loaded between 30N and 150N at 50 mm/min rate for 1000 cycles and maximal tensile testing was performed. A preload of 30N was applied to the graft along the axis of the tunnel 15 minutes. ANOVA and the Duncan multiple comparison test was used for the statistical analysis. Results: The mean maximum tensile strength of femoral fixation before and after the cyclic loading test were 1003.4$\pm$145N and 601.1$\pm$154N in hamstring-LA screw(R) group, 595.5$\pm$104N and 360.7$\pm$56N in hamstring-Bioscrew(R) group, 1431.7$\pm$135N and 710.7$\pm$114N in hamstring-Semifix(R) group, 603.6$\pm$54N and 459.1$\pm$46N in hamstring-Endobutton(R) fixation group, 1067.4$\pm$145 and 601.8$\pm$134N in the BPTB-Titanium interference screw group, and 987.1$\pm$168N and 588.7$\pm$124N in the BPTB-Bioscrew(R) group. And these data illustrated that cyclic loading reduces the maximum tensile strength by 40 $\%$, 39 $\%$, 50 $\%$, 24 $\%$, 44 $\%$, 40 $\%$ respectively. Conclusions: With the results of these experiments it should be emphasized that rehabilitation exercises after anterior cruciate ligament reconstruction should be executed with precaution as the repetitive flexion and extension of the knee would compromise the maximum tensile strength of the graft tendon.

  • PDF

Widening of Bony Tunnel after ACL Reconstruction Using Hamstring Tendon with Ligament Anchor(LA) Screw (슬괵건 및 LA나사를 이용한 관절경적 전방 십자 인대 재건술 후 골터널의 확장)

  • Song Eun Kyoo;Yoon Taek Rim;Jung Jong Wook;Jeong Kwang Cheul
    • Journal of the Korean Arthroscopy Society
    • /
    • v.5 no.2
    • /
    • pp.69-73
    • /
    • 2001
  • Purpose : To evaluate the clinical results and widening of bony tunnel after anterior cruciate ligament(ACL) reconstruction using hamstring tendon with Ligament Anchor(LA) screw, which is newly designed fur fixation of graft into femur. Materials and Methods : Fifty eight patients who were followed up at least more than 2 years after ACL reconstruction with four strands of Hamstring tendon were included in this study. The graft was fixed with LA screw at femoral tunnel and with bioabsorbable interference screw at tibial tunnel. The average period of follow-up was 28 months. The clinical results such as physical examination and Lysholm knee score and radiological results. widening of bony tunnel and instrumented anterior laxity test with $Telos^{\circledR}$(Telos stress device; Austin & Associates, Inc., Polston, US) were evaluated. Results . The Lysholm knee score was 60.0 in average preoperatively and improved to 94.0 in average at follow up. On the Lachman test, there were mild(+) instability in 16 cases, moderate(++) in 24, severe(+++) in 18 preoperatively. 50 cases were converted to negative and 8 to mild instability at follow up. On instrumented anterior laxity test with $Telos^{\circledR}$, side to side difference in 20 lb was 12.9mm in average preoperatively, and was decreased to 3.1mm in average follow-up. The femoral tunnel was widened from 10.6mm postoperatively to 12.7mm$(21.1\%)$ at follow up on antero-posterior plane and from 10.7mm to 12.4mm$(16.5\%)$ on lateral plane. Tibial tunnels was also widened from 9.8mm to 11.8mm$(20.7\%)$ on antero-posterior plane and from 9.9mm to 11.7mm$(18.9\%)$ in lateral plane. Conclusion : ACL reconstruction with hamstring tendon and LA screw was one of the choice of grafts and fixatives in restoring knee stability and in improving clinical results with little complications such as excessive widening of bony tunnel.

  • PDF

Comparative Biomechanical Study of Stiffness on Ligamentous Attached Sites of Distal Femur - Experimental Laboratory Study on Cadaver Femora - (원위 대퇴골 인대 부착부의 강도 비교 - 사체의 대퇴골에 행한 실험적 연구 -)

  • Kwak, Ji-Hoon;Sim, Jae-Ang;Yang, Sang-Hoon;Kim, Dong-Hee;Lee, Beom-Koo
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.8 no.1
    • /
    • pp.26-32
    • /
    • 2009
  • Purpose: This study was performed to compare the strength of ligamentous attached sites of cadaveric distal femur and to obtain reliable biomechanical data to use in ligamentous reconstruction or augmentation. Materials and Methods: Fifteen cadaveric distal femurs were used for this study. After measuring the bone density, 5.0 mm cannulated screw (Experiment 1) or reconstructed porcine ligament (Experiment 2) was inserted into the each ligamentous attached sites of anterior cruciate ligament (ACL), posterior cruciate ligament (PCL), medial collateral ligament (MCL) and lateral collateral ligament (LCL). In experiment 2, reconstructed porcine graft was fixed with bioabsorbable screw in ligamentous insertion sites. And we measured the maximal pullout force of each ligamentous attached sites of cadaveric distal femur. Results: Average bone mineral density was $1.205{\pm}0.137\;g/cm^2$ in experiment 1, $1.236{\pm}0.089\;g/cm^2$ in experiment 2, which showed no statistically significant differences. In experiment 1, average pull-out strength of ACL, PCL, MCL and LCL group were $519.1{\pm}111.7$ N, $638.9{\pm}144.4$ N, $169.7{\pm}56.0$ N, $225.6{\pm}61.5$ N respectively. In experiment 2, the average pull-out strength were $310.6{\pm}31.0$ N, $379.9{\pm}47.4$ N, $104.0{\pm}14.4$ N, $131.5{\pm}21.9$ N respectively. In experiment 1, there was no significant difference between ACL and PCL group and between MCL and LCL group. However, the maximal pullout strength of MCL and LCL group were significantly lower than that of ACL and PCL group (p<0.01). Experiment 2 showed the same results of experiment 1. Conclusion: Because stiffness of MCL and LCL attached sites are much lower than that of ACL and PCL attached sites, we may consider augmented fixation in ligamentous reconstructions of MCL and LCL.

  • PDF

Clinical Results of Anterior Cruciate Ligament Reconstruction Using Hamstring Tendon (슬괵건을 이용한 전방십자인대 재건술의 임상적 결과)

  • Song Eun Kyoo;Lee Keun Bae;Shin Sang Gyoo;Kim Hyun Jong
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.1 no.1
    • /
    • pp.21-25
    • /
    • 2002
  • Purpose: To evaluate the clinical results after anterior cruciate ligament (ACL) reconstruction with hamstring tendon and Ligament Anchor (LA) screw, which is newly designed for fixation of graft into femur. Materials and Methods: Fifty eight patients who were followed up at least more than 2 years after ACL reconstruction with four strands of Hamstring tendon and LA screw were included in this study. The graft was fixed with LA screw at femoral tunnel and with only bioabsorbable interference screw at tibial tunnel. The mean follow-up period was 28 months. The clinical results were evaluated by physical examination and Lysholm knee score. Widening of bony tunnel and anterior laxity difference compared with normal side by instrumented anterior laxity test with Telos(R) (Telos stress device; Austin & Associates, Inc., Polston, US) were evaluated. Results: The Lysholm knee score improved from 60.0 points preoperatively to 94.0 points at last follow up. On the Lachman test, there were mild (+) instability in 16 cases, moderate (++) in 24,severe (+++) in 18 preoperatively. 50 cases were converted to negative and 8 to mild instability at postoperative follow up. On instrumented anterior laxity test with Telos(R), difference between normal and affected knee on 20 lb was 12.9 mm in average preoperatively, and was decreased to 3.1mm at last follow-up. The femoral tunnel was widened from 10.6 mm postoperatively to 12.7 mm (21.1$\%$) at follow up on antero-posterior plane and from 10.7 mm to 12.4 mm (16.5$\%$) on lateral plane. Tibial tunnels was also widened from 9.8mm to 11.8mm (20.7$\%$) on antero-posterior plane and from 9.9mm to 11.7 mm ($18.9\%$) on lateral plane. Complications were: anterior knee crepitus in 17 case, quadriceps muscle atrophy(>3 cm) in 6, penetration of screw over the lateral femoral cortex in 5, saphenous nerve paresthesia in 2.Conclusions: ACL reconstruction with hamstring tendon and LA screw was one of the choice of grafts and fixation devices in restoring knee stability and in improving clinical results with little complications such as excessive widening of bony tunnel and anterior knee pain

  • PDF

Comparision of Trans-Tibial and Anteromedial Portal Approach in Femoral Tunneling of Anterior Cruciate Ligament Reconstruction (전방십자인대 재건술의 대퇴골 터널 굴착시 경경골 접근법과 전내측통로 접근법의 비교)

  • Sohn, Sung-Keun;Chang, Yun-Suk;Chung, ll-Kwon;Kim, Kyung-Taek
    • Journal of the Korean Arthroscopy Society
    • /
    • v.8 no.2
    • /
    • pp.75-81
    • /
    • 2004
  • Purpose: Recent development and advances in arthroscopic surgical techniques for Anterior Cruciate Ligament(ACL) reconstruction have led to the ideal location for the etric point from 10 o'clock (in right knee) and 13:30 (in left knee) to 10:30 (in right knee) and 14 o'clock (in left knee) in the frontal plane. This study was performed to compare operative methods and the radiologic results of femoral tunnels made through the tibial tunnel(trans-tibial approach) and the anteromedial portal. Material and Methods: From January 2003 to May 2004, one-hundred reconstructions of anterior cruciate ligament were performed. Group I (femoral tunnel through tibial tunnel) was composed of 50 cases and group ll (femoral tunnel through anteromedial portal) was consisted of 50 cases. The study was performed to compare the radiographic results of femoral tunnels made through the tibial tunnel and the anteromedial portal and operative methods. Results: In operative methods at Group II, femoral tunnel was made more easily at isometric point than Group I, a good visual field was achived because 100$^{\circ}$ flxion of knee, they can be reduced risk of posterior cortical breakage and tunnel-graft mismatching and decreased divergence of femoral interference screw in radiology (P<0.05). The angle between femoral tunnel and longitudinal axis of ACL wae increased at Group ll. Conclusion: Aanteromedial portal technique was more useful in ACL reconstruction for femoral tunnel toward 10 o'clock to10:30(in right) or 1:30 to 2 o'clock(in left).

  • PDF

Revision Anterior Cruciate Ligament Surgery Using Hamstring Autograft (슬괵건을 이용한 전방 십자 인대 재 재건술)

  • In Yong;Bahk Won-Jong;Kwon Oh-Soo;Suh Young-Wan;Im Dong-Sun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.7 no.2
    • /
    • pp.183-188
    • /
    • 2003
  • Purpose : The purpose of this study is to evaluate the results of revision surgery for failed anterior cruciate ligament (ACL) reconstruction using quadruple hamstring tendon autograft. Materials and Methods : From May 2000 to July 2002, six patients received ACL revision surgery using quadruple hamstring autograft for failed ACL reconstruction. Femoral tunnels were made 40 mm in depth and fixed with a cross pin and a bioabsorbable interference screw to fill the bone defect. In tibial tunnels, the grafts were fixed with Intrafix(Mitek, Norwood, MA). In case of tibial tunnel widening, additional screw-washer fixation was done. Follow up was at least 12 months postoperatively. Clinical assessments consisted of Lysholm knee scores, International Knee Documentation Committee(IKDC) evaluation form and manual maximal side to side difference using KT-2000 arthrometer. Results : The average Lysholm knee score improved from 77.2 preoperatively to 87.7 postoperatively. At the final IKDC evaluation, 1 case was graded as normal, 4 nearly normal, 1 abnormal. Mean side to side difference of manual maximum anterior displacement using the KT-2000 arthrometer was 1.8mm. The success rate was $83\%$. Conclusion : ACL revision surgery using quadruple hamstring autograft with double fixation is considered good procedure with successful results.

  • PDF