• Title/Summary/Keyword: 대퇴피질골두께

Search Result 10, Processing Time 0.025 seconds

Effect of Cortical Bone on Acoustic Properties of Trabecular Bone in Bovine Femur In Vitro (생체 외 조건의 소 대퇴골에서 해면질골의 음향특성에 대한 피질골의 효과)

  • Hwang, Kyo Seung;Lee, Kang Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.2
    • /
    • pp.181-189
    • /
    • 2013
  • The purpose of the present study is to investigate the effect of cortical bone on acoustic properties of trabecular bone, such as speed of sound (SOS) and normalized broadband ultrasound attenuation (nBUA), in bovine femur in vitro. Twelve trabecular bone samples and three cortical bone plates with thicknesses of 1.00, 1.47, and 2.00 mm were extracted from the proximal end of two bovine femurs. The correlations between acoustic properties and trabecular apparent bone density were also examined before and after attaching a cortical bone plate to the trabecular bone samples. SOS increased linearly with increasing thickness of the cortical plate attached to one side of ultrasonic incidence of the trabecular bone samples, whereas nBUA showed a nonlinear dependence on the thickness of the cortical plate. All the SOS (r = 0.95-0.97) and nBUA (r = 0.53-0.73) measurements with and without the cortical bone plate with various thicknesses were found to exhibit high correlations with the trabecular apparent bone density. These results imply that the acoustic properties measured in the femur with lateral cortical layers in vitro can be useful indices for the prediction of trabecular bone mineral density.

Influence of Cortical Endplates on Ultrasonic Properties of Trabecular Bone (피질골판이 해면질골의 초음파 특성에 미치는 영향)

  • Kim, Yoon Mi;Lee, Kang Il
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.2
    • /
    • pp.103-111
    • /
    • 2015
  • The present study investigated the influence of thick cortical endplates on the ultrasonic properties of trabecular bone in a femur with a high fracture risk. Twelve trabecular bone samples were prepared from bovine femurs, and acrylic plates with thicknesses of 1.25, 1.80, and 2.75 mm were manufactured to simulate the cortical endplates using acrylic with a density and a sound speed similar to cortical bone. Although the thickness of the acrylic plates attached to the two sides of the trabecular bone increased, high correlations were observed between the speed of sound and the apparent bone density of the trabecular bone, with Pearson's correlation coefficients of 0.80-0.86. High correlations were also observed between the attenuation coefficient at 0.5 MHz and the apparent bone density of the trabecular bone, with Pearson's correlation coefficients of 0.84-0.91. These results suggest that the speed of sound and attenuation coefficient at a specific frequency measured in a femur with relatively thick cortical endplates compared to the calcaneus could be used as indices for predicting the bone mineral density of the femur.

MECHANICAL AND HISTOMORPHOLOGIC CHANGES OF THE RAT FEMUR AFTER ADMINISTRATION OF SODIUM FLUORIDE (불화물에 의한 백서 대퇴골의 강도 및 조직형태학적인 변화)

  • Lee, Soo-Koung;Song, Keun-Bae;Jang, Hyun-Jung
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.4
    • /
    • pp.363-368
    • /
    • 2000
  • The purposes of the study was to examine changes in thickness and strength of the rat femur after administration of sodium fluoride in the drinking water. 48 female Sprague-Dawley rats were randomly divided into 4 groups, and they were supplied with 0(control), 1, 5 and 50 ppm of fluoride in the drinking water ad libitum for 6 weeks. Rats were killed and both sides of femur were dissected. Bone strength was measured as the stress of failure of femur at the middle point and femoral neck with Instron. Histologic slides were prepared from the femur shaft with routine processing of fixing, demineralizing, embedding and HE staining. Thickness and area of cortical bone and medullary cavity were measured by using Camera Lucida and Image Analyzer. All the collected data were analyzed with one-way ANOVA, Duncan's multiple range test for post-hoc tests and ANCOVA using the SAS 6.12 package at the level of 0.05. Bone strength increased significantly in the animals given 1 and 5 ppm of fluoride in the water, as compared to the control group. There were significant decreases of stress at fracture in 50 ppmF group compared to the 1 and 5 ppmF groups. The similar trends of bone strength at the femoral neck fracture test, but there were no statistical significances. Cortical bone thickness and area of the femur increased in the 1 and 5 ppmF groups compared to the control. However, the thickness of 50 ppmF group also decreased significantly as compared to 1 and 5 ppmF groups. On the other hand, medullary thickness and area increased in all fluoride groups than control group. All of the findings presented support the conclusion that, low fluoride dosage used in water fluoridation could increase the bone strength and might have preventive effect on femur fracture.

  • PDF

Diagnostic Coincidence of Radiologic Measurement Methods of the Proximal Femur Anterior-posterior Projection for Assessment of Osteoporosis (근위대퇴부 정면 영상을 이용한 골다공증 평가 시 방사선적 계측의 진단일치도)

  • Kang, Yeong-Han;Cho, Kwang-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.6
    • /
    • pp.353-360
    • /
    • 2012
  • The purpose of this study was to determine whether there are relationships between radiologic parameters for osteoporosis by the proximal femur radiograhps and bone mineral density, as assessed by Dual Energy X-ray Absorptiometry(DEXA). Proximal femur anterior-posterior projection were taken from 112 individuals who undergoing DEXA. Radiographic parameters including canal-to-calcar ratio(CCR) and cortical thickness indices(CTI) were measured and compared with bone mineral density($g/cm^2$), T-score. The intramedullary femoral canal width(FW) and calcar width(CW) at osteoporosis group was significantly larger than that of control group. The CCR were correlated negatively with bone mineral density($g/cm^2$)(r=-0.340, p<0.01), and the CTI were correlated positively(r=0.624). The diagnostic accuracy of CCR for osteoporosis was 63.4%, and kappa value was 0.271. And the accuracy of CTI was 67.0%, and kappa value was the level of fair agreement(${\kappa}$=0.258). The proximal femur with large CCR and small CTI had lower T-scores. When evaluating proximal femur anterior-posterior radiographs, those patients with the thinnest femur diaphyseal cortices should be referred for further osteoporosis investigation.

Ultrasonic methods for measuring the cortical bone thickness in bovine tibia in vitro (생체 외 조건의 소 경골에서 초음파를 이용하여 피질골 두께를 측정하기 위한 방법)

  • Lee, Kang Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.5
    • /
    • pp.557-563
    • /
    • 2022
  • The cortical bone thickness of the tibia is related to fracture risk and overall bone status. The present study aims to investigate the feasibility of two different ultrasonic methods for measuring the cortical bone thickness in bovine tibia in vitro. In the reflection technique, the tibial cortical thickness was determined from ultrasonic reflections from the periosteum and the endosteum producing specific peaks in the signal envelope. In the axial transmission technique, the tibial cortical thickness was determined from ultrasonic guided wave velocities measured along the axial direction of the tibia. The cortical bone thickness determined by using the reflection technique correlated significantly with that measured by using a caliper, with a Pearson's correlation coefficient of r = 0.97 (p < 0.0001). In contrast, the correlation coefficients for the axial transmission technique were r = 0.92 (p < 0.0001) for the first arriving signal method and r = 0.89 (p < 0.0001) for the slow guided wave method. Clinical feasibility should be demonstrated with an in vivo application to address the question whether the ultrasonic methods presented here could be useful as a screening tool for osteoporosis and potentially could be applied to other skeletal sites such as the femur and the radius.

Correlations between the group velocity of time-reversed Lamb waves and cortical bone properties in tibial cortical bone in vivo (생체 내 경골의 피질골에서 시간역전 램파의 군속도와 피질골 특성 사이의 상관관계)

  • Kang Il Lee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.6
    • /
    • pp.559-564
    • /
    • 2023
  • It is known that change in the bone strength of cortical bone constituting the outer shell of long bones such as the tibia or radius due to aging and osteoporosis is a risk factor for fracture. In this study, the group velocity of time-reversed Lamb waves generated in tibial cortical bone in vivo was measured using a time reversal method, and the correlations of the group velocity with the cortical bone thickness (cTh) and cortical bone mineral density (cBMD) closely related to the bone strength were investigated. It was found that the group velocity of time-reversed Lamb waves measured in the right tibia of 7 subjects showed a very high correlation, r = 0.90 (p < 0.0001), with the cTh and a relatively low correlation, r = 0.69 (p < 0.0001), with the cBMD. A limitation of this in vivo study is that the group velocity of time-reversed Lamb waves was measured for a normal group consisting of only 7 healthy adults. In the future, if the clinical usefulness of the time-reversed Lamb wave is demonstrated by follow-up studies on normal and osteoporotic groups consisting of a large number of healthy adults and osteoporotic patients, respectively, it is expected to improve the reliability of quantitative ultrasound technology for osteoporosis diagnosis. In addition, it is necessary to expand the skeletal site for measuring the group velocity of time-reversed Lamb waves not only to the tibia but also to the femur or radius.

ACL Reconstruction with Remnant Preserving Technique - Technical Note - (잔류조직 보존 술기를 이용한 전방 십자 인대 재건술 - 수술 술기 -)

  • Cho, Sung-Do;Youm, Yoon-Seok;Jeong, Ji-Young;Jeon, Hyung-Min
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.1
    • /
    • pp.82-85
    • /
    • 2009
  • Purpose: In anterior cruciate ligament (ACL) reconstruction, preservation of the remnant original tissue might promote graft healing and be helpful in proprioception. But this procedure is difficult and causes the notch impingement. So we introduce a surgical technique that makes a transtibial femoral tunnel at 10 or 2 o'clock position with preservation of remnant tissue. Surgical approach: We tried to preserve the remnant tissue and synovium as much as possible, especially those of tibial attachment and extending to the posterior cruciate ligament (PCL), so as to have some tension and to prevent notch impingement. We set the tibial drill guide at 40~45 degrees and the intra-articular guide tip was 1 mm anterior and medial to the conventional site. The starting point of tibial guide pin was proximal to the pes anserinus and anterior to the medial collateral ligament. When the reamer approached the cortical bone of the tibial articular surface, the reamer must be advanced very carefully to minimize injury to the remnant tissue. The tibial and femoral tunnel at 10 or 2 o'clock position were made with the reamer, the diameter of which was same with that of the graft. Conclusion: We report a remnant preserving technique in ACL reconstruction that makes a transtibial femoral tunnel at 10 or 2 o'clock position

  • PDF

Comparison of Gap Pressure in Opening Wedge High Tibial Osteotomy versus Compressive Strength of Allogenous Wedge Bone Blocks (경골 근위부 개방 절골술 시 개방부 압력과 동종 쐐기 골편의 최대압축하중 비교)

  • Yoon, Kyoung Ho;Kim, Jung Suk;Kwon, Yoo Beom;Kim, Eung Ju;Lee, Myeong-Kyu;Kim, Sang-Gyun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.2
    • /
    • pp.127-134
    • /
    • 2020
  • Purpose: The aims of this study were (1) to investigate the relationship between the characteristics of allogenic bone block and the compressive strength of an allogenic bone block measured by biomechanical experiments, and (2) to compare the maximum pressure load of allogenic bone block with the gap pressure measured at the high tibial opening osteotomy. Materials and Methods: Ten patients who provided informed consent for gap pressure measurements during opening wedge high tibial osteotomy (OWHTO) were included. The gap pressures were measured at 1 mm intervals while opening the osteotomy site from 8 mm to 14 mm. Seventeen U-shaped allogenous wedge bone blocks were made from the femur, tibia, and humerus. The height, width, cross-sectional area, and cortex thickness of the bone blocks were measured, along with the maximum compressive load just before breakage. The relationship between these characteristics and the maximum pressure load of the bone blocks was evaluated. The gap pressures measured in OWHTO were compared with the maximum pressure loads of the allogenous wedge bone blocks to evaluate the possibility of inserting allogenous wedge bone blocks into the osteotomy site without a distractor in OWHTO. Results: The OWHTO gap pressure increased with increasing osteotomy site opening. The mean gap pressure, which occurred at a 14-mm opening, was 282±93 N; the maximum pressure was 427 N. The maximum pressure load of the allografts was 13,379±6,469 N (minimum, 5,868; maximum, 29,130 N) and was correlated significantly with the cortical bone thickness (correlation coefficient=0.693, p=0.002) and cross-sectional area (correlation coefficient=0.826, p<0.001). Depending on the sterilization method, the maximum pressure loads for the bone blocks were 13,406±5,928 N for freeze-dried and 13,348±7,449 N for fresh frozen. The maximum compressive load of the allogenous wedge bone blocks was 13.7-times greater than that in OWHTO opened to 14 mm (5,868 N vs. 427 N). Conclusion: The compressive strength of allogenous wedge bone blocks was sufficiently greater than the gap pressure in OWHTO. Therefore, allogenous wedge bone blocks can be inserted safely into the osteotomy site without a distractor.

The effect of steroid for fibrous dysplasia of the humerus combined with multiple cystic lesion (낭종성 병변을 동반한 상완골의 섬유성 골이형성증에서 steroid의 효과 - 증례 보고 -)

  • Hahn, Soo-Bong;Shin, Kyoo-Ho;Kim, Bo-Hyun;Won, Jung-Hoon
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.8 no.1
    • /
    • pp.20-26
    • /
    • 2002
  • Fibrous dysplasia is a benign pathologic condition in which the normal cancellous bone is replaced by the fibro-osseous tissue. It is found mostly in the femur, tibia, skull, rib, and humerus. Clinically it may develops pain, progressive deformity, and pathologic fracture. Curettage with bone graft has been the most popular treatment method thesedays. A 17-year-old female who had fibrous dysplasia of the humerus combined with multiple cystic lesion was treated by intralesional steroid injection into the lesion total 2 times. The follow-up plain X-ray which was taken 11 months after steroid injection reveals decrease in size and increase in bone density and cortex thickness. The follow-up MRI reveals significant decrease in size and signal intensity. The signal intensity was decreased to that of normal bone marrow in T2 weighted image. She complains no pain and lives symptom free in last follow-up at 2 years and 8 months after steroid injection.

  • PDF

Anterior Cruciate Ligament Double Bundle Reconstruction with Hamstring Tendon Autografts - Technical Notes (자가 슬괵건을 이용한 전방 십자 인대 이준 다발 재건술 - 수술 술기 -)

  • Ahn, Jin-Hwan;Lee, Sang-Hak;Ahn, Hyung-Kwon;Kang, Hong-Jae
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.2
    • /
    • pp.222-231
    • /
    • 2005
  • Purpose: This article describes a double-bundle ACL reconstruction technique using a five-strand hamstring tendon autograft with conventional anteromedial bundle reconstruction and additional posterolateral bundle reconstruction. Operative technique: For the tibial tunnel, the conventional single tunnel technique is performed and for the femoral tunnel, the double tunnel technique is performed with the anteromedial and posterolateral bundle. After minimal notchplasty, the anteromedial femoral tunnel is prepared with leaving one milimeter of posterior femoral cortex within the over-the-top, which if positioned at the 11-o'clock orientation for the right knee or at the 1-o'clock position for the left knee. The posterolateral femoral tunnel that is located 5 to 7 mm superior to the inner margin of the lateral meniscus anterior horn at $90^{\circ}$ of flexion is prepared with tile outside-in technique using a 4.5 cannulated reamer. The graft material for the double bundle reconstruction is made of the conventional four-strand hamstring autograft in the anteromedial bundle and of a single-strand semitendinosus tendon in the posterolateral bundle. The anteromedial bundle is fixed with using a rigid fix system on the femoral side and the posterolateral bundle is fixed to tie with the miniplate from the outside femur. Then, with the knee in $10^{\circ}\;to\;20^{\circ}$ of flexion, a bioabsorbable screw is simultaneously applied to achieve tibial fixation with tensioning of both bundles. Conclusion: A double bundle reconstruction with five-strand hamstring autograft, which is designed with a favorable conventional anteromedial bundle and an additional posterolateral bundle to restore rotation stability, seems to be a very effective method for the treatment for ACL instabilities.

  • PDF