• Title/Summary/Keyword: 대퇴스템

Search Result 7, Processing Time 0.016 seconds

Decision-Making and Principle of Management in Periprosthetic Femoral Fracture after Total Hip Arthroplasty (고관절 치환술 후 삽입물의 안정성 판단과 대퇴 삽입물 주위 골절의 치료 원칙)

  • Kim, Beom-Soo;Lee, Kyung-Jae;Min, Byung-Woo
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.3
    • /
    • pp.200-207
    • /
    • 2021
  • Periprosthetic femoral fractures remain as one of the most challenging complications following total hip arthroplasty. A thorough clinical and radiographic evaluation, precise classification, and understanding of modern management principles are essential to obtain optimal results for these fractures. The Vancouver classification system is a simple, effective, and reproducible method for the planning treatments of these injuries. The fractures associated with a stable femoral stem can be treated effectively with osteosynthesis, but periprosthetic femoral fractures associated with a loose stem require revision arthroplasty. This paper describes the principle of the treatment of patients with periprosthetic femoral fractures and how to assess the stability of the femoral stem.

Behavior Analysis of the Treated Femur and Design of Composite Hip Prosthesis (대퇴부 거동 해석 및 복합재료 보철물 설계)

  • 임종완;하성규
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.2
    • /
    • pp.119-130
    • /
    • 2002
  • The nonlinear finite element program has been developed to analyze the design performance of an artificial hip prosthesis and long term behavior of a treated femur with stems made of composite material after cementless total hip arthroplasty(THA). The authors developed the three dimentional FEM models of femoral bone with designed composite stem which was taken with elliptic cross section of 816 brick elements under hip contact load and muscle farce in simulating single leg stand. Using the program, density changes, stress distributions and micromotions of the material femoral bone were evaluated by changing fiber orientation of stems for selected manufacturing method such as plate cut and bend mold. The results showed that the composite materials such as AS4/PEEK and T300/976 gave less bone resorption than the metallic material such as cobalt chrome alloy, titanium alloy and stainless steal. It was found that increasing the long term stability of the prosthesis in the femur could be obtained by selecting the appropriate ply orientation and stacking sequence of composite.

A Study on Computer Aided Surgical Simulation Method for Total Hip Arthroplasty (컴퓨터 응용 인공고관절 모사 시술 방법 연구)

  • Kim Sang Hoo;Han Seung Moo
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.455-464
    • /
    • 2004
  • Total hip arthroplasty(THA) considerably depends on high-experienced doctors because of high difficulty of the operation. Selection of acetabular cup's and femoral implant's position is closely related with success or failure of THA. Nevertheless the selection has usually depended on doctor's eye measurement, which makes the position accuracy of artificial joint lower after THA, often resulting in revision of THA. The present study determined a method to select accurately the position of acetabular cup and femoral implant through surgical simulation with 3D characteristic geometrical information of patient's pelvis and femur. We examined the change of femoral anteversion angle and neck-shaft angle accompanied by the change of acetabular cup's position and the insertion position of femoral implant. As result of analyzing geometrical information through different surgical simulations, we found that it was possible to select the accurate position of acetabular cup and femoral implant. It is expected to help doctors get experienced in THA operation through repetitive surgical simulations using the method suggested in the study.

Biomechanical characteristics of the distal filling effects in cementless femoral stem (무시멘트형 대퇴스템에서 원위부 압박 정도에 따른 생체역학적 특성)

  • Park, Sang-eok;Park, Jae-Won;Chae, Soo-Won
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.387-392
    • /
    • 2000
  • In cementless total hip replacement(THR), an initial stability of the femoral component is important to long term fixation of femoral stem. The initial stability has close relationship with the relative displacement of prosthesis and spongy bone at the proximal of femur. After implantation of the prosthesis. the surrounding bone is partially shielded from load carrying and starts to resort. Stress shielding is the cause of the loss of proximal bone. Assessing stress distribution of femur is important to predict stress shielding. The initial stability and the stress shielding were investigated for two loading conditions approximating a single leg stance and a stair climbing. Three types of stems were studied by the finite element method to analyze the biomechanical effects of distal filling of cementless femoral stems, Three types of stems employed are a distal filling stem, a distal flexible stem, and a distal tapered stem.

  • PDF

Midterm Results of Bipolar Hemiarthroplasty for Unstable Intertrochanteric Femoral Fractures Using a Type 3C Cementless Stem (불안정성 대퇴골 전자간 골절에 3C형 무시멘트 대퇴 스템을 이용한 고관절 반치환술의 중기 결과)

  • Chung, Woochull;Cho, Hong Man;Kim, Sun do;Park, Jiyeon;Kwon, Kihyun;Lee, Young
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.6
    • /
    • pp.503-510
    • /
    • 2020
  • Purpose: Bipolar hemiarthroplasty is used as an alternative to open reduction and internal fixation for unstable intertrochanteric fractures in elderly patients. Recent advances in medical systems and technologies have resulted in increased survival rates after intertrochanteric fractures of the femur, requiring selection of the appropriate femoral stems considering the mid- to long-term duration of survival. Hemiarthroplasty was performed for unstable intertrochanteric fractures using a double tapered quadrilateral femoral stem (C2 stem), and the clinical and radiological results were evaluated as a five-year follow-up post-surgery. Materials and Methods: From January 2004 to December 2013, 43 patients (43 hips) who underwent hemiarthroplasty with a C2 stem were enrolled in this study. Their mean age was 78.6 years (range, 70-84 years), and the mean follow-up period was 85.4 months (range, 60-96 months). During the follow-up period, clinical parameters, such as the changes in pain, walking ability, and functional status, were examined. Radiologically, changes in the proximal femur, such as osteoporosis and bone resorption of cortical bone, were noted. Complications that occurred during the follow-up period, such as dislocation and prosthetic features, were also reviewed. Results: Initially, the pain was relieved postoperatively, but it increased four years after surgery. The walking ability was reduced by two steps in nine patients after 60 months, and the Harris hip score was reduced significantly postoperatively after two to three years. Radiologically, cortical osteoporosis occurred in 14 patients. Five patients developed cortical bone resorption. Four of them showed nonunion of the trochanteric fracture fragments, and three of them suffered reverse oblique fractures. Conclusion: Careful selection considering the general health condition and remaining lifespan of the patient would be necessary for primary hip hemiarthroplasty using a 3C type cementless femoral stem for unstable intertrochanteric fractures in elderly patients with osteoporosis.

Cementless Total Hip Arthroplasty Using Ceramic Femoral Head on Cross-Linked Ultra-High-Molecular Weight Polyethylene Liner in Patients Older than 65 Years: Minimum Five-Year Follow-Up Results (세라믹 대퇴 골두 및 교차결합 초고분자량 폴리에틸렌 라이너를 이용한 65세 이상 무시멘트형 인공 고관절 전치환술: 최소 5년 중기 추시 결과)

  • Yun, Ho Hyun;Cheong, Ji Young;Sim, Hyun Bo;Park, Jae Hong
    • Journal of the Korean Orthopaedic Association
    • /
    • v.53 no.6
    • /
    • pp.490-497
    • /
    • 2018
  • Purpose: To evaluate the utility of ceramic-on-polyethylene articular bearing surface when cementless total hip arthroplasty is performed in patients older than 65 years through an analysis of the minimum five-year follow-up results using the ceramic femoral head and cross-linked polyethylene liner. Materials and Methods: From March 2010 to September 2012, 51 patients (56 hips) who were older than 65 years were enrolled in this retrospective study. The mean age at surgery was $70.9{\pm}5.1years$ old. A clinical assessment was analyzed using the Harris hip score. For the radiographic assessment, the cup inclination and anteversion, stem alignment, and wear amount were measured. The postoperative complications were also determined. Results: The mean Harris hip score was improved from preoperative 48 points to postoperative 87 points (p<0.05). The mean cup inclination was $40.9^{\circ}{\pm}6.4^{\circ}$ and the mean cup anteversion was $20.3^{\circ}{\pm}8.1^{\circ}$. The mean cup anteversion of the elevated liner-used group (16 cases) was $14.3^{\circ}{\pm}7.9^{\circ}$ and the mean cup anteversion of the neutral liner used group (40 cases) was $22.4^{\circ}{\pm}9.1^{\circ}$ (p<0.05). The mean stem alignment angle was $0^{\circ}$ (range, varus $4^{\circ}$-valgus $4^{\circ}$). The mean linear wear amount was $0.458{\pm}0.041mm$ and the average annual linear wear rate was $0.079{\pm}0.032mm/yr$. Six cases (10.7%) of intraoperative periprosthetic femoral fractures were encountered. Conclusion: Based on these results, the use of a ceramic-on-polyethylene articular bearing surface in elderly patients with cementless total hip arthroplasty is beneficial. On the other hand, careful effort is needed to prevent intraoperative periprosthetic femoral fractures.

Development of Hip Joint Mechanical Stem for Minimally Invasive Surgery (최소침습술을 위한 고관절 메커니컬 스템의 개발)

  • Lee, Sunghyun;Bae, Ji-Yong;Jeon, Insu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.7
    • /
    • pp.703-708
    • /
    • 2013
  • Conventional total hip joint replacement(THR) surgery requires a long incision and long rehabilitation time. The stem used in THR is inserted into the cancellous bone of the femur where it plays the role of the artificial joint. Minimally invasive surgery(MIS) has been devised to reduce muscle damage to patients. In this study, a mechanical stem was developed on the basis of MISto reduce the incision length through the principle of the gear. The mechanical stem consists of six components. A prototypical model for a mechanical stem was fabricated using an acryl-based polymer, and its workability was confirmed. To actualize the mechanical stem, a three-dimensional Bio-CAD modeling technique was applied. The hip joint area based on computed tomography(CT) was reconstructed. The safety of the mechanical stem by applying more load than the weight of a man under virtual surgery environment conditions was confirmed by finite element analysis.