• Title/Summary/Keyword: 대책 방안

Search Result 2,194, Processing Time 0.031 seconds

Design and Analysis of Data File Protection based on the Stream Cipher (데이터파일의 보호를 위한 스트림 암호방식 설계와 해석)

  • 이경원;이중한;김정호;오창석
    • The Journal of the Korea Contents Association
    • /
    • v.4 no.1
    • /
    • pp.55-66
    • /
    • 2004
  • Recently, as the personal computers are supplied rapidly, they formed the nucleus of the computer system. But, because of the easiness that anyone uses them to go near easily, it is the fact that the security of personal computer is weakness. So, in the paper, 1 propose the technical method that minimizes the loss and leakage of important data. This paper implemented a crypto system for security of data file on personal computer and assistance storage medium. The way of encryption/decryption is applied by complexity method which mixed Diffie-Hellman key exchange protocol, a typical RC4(Rivest Cipher version 4) algorithm of stream cipher and a typical MD5(Message Digest version 5) of Hash Function. For valuation implemented crypto system, three criteria is presented, which are crypto complexity, processing time and pattern matching. And according to analysis the three criteria the crypto system is verified the security, efficiency and usefulness. The crypto system is programmed with Visual C++ language of Microsoft. And so, as this is software system, we shall have a technical security system at a minimum cost for all personal computer.

  • PDF

The Influence of Information Security Behaviors on Information Security Performance in Shipping and Port Organization (해운항만조직의 정보보안이행이 정보보안성과에 미치는 영향)

  • Kang, Da-Yeon;Chang, Myung-Hee
    • Journal of Navigation and Port Research
    • /
    • v.40 no.4
    • /
    • pp.213-222
    • /
    • 2016
  • Recently, as cases of organizations' information disclosure occur continuously, it is urgent to manage security of information and establish measures to enhance security of information by an organization itself. Especially, members of an organization should be prepared with measures for information security, and an organization should do its efforts to raise its members' awareness toward information security. I set a research model to verify what effects an organization's fulfillment of regulations to secure information brings to performance of information security and selected members from maritime and port organizations and financial and insurance institutes as sample. Results of the analysis to identify factors affecting information security performance among members of maritime and port organizations are as follows. Firstly, I found that the factors affecting information security awareness are information security attitude and information security standards. Secondly, the factor giving influence on information security policy of an organization was found to be information security standards. In contrast, information security punishments and information security training were verified not to give influence on compliance of information security policy. Thirdly, information security awareness was identified to give significant influence on compliance of information security policy, information security competence and information security behavior. Fourthly, compliance of information security policy was verified to be those factors that give influence on information security competence and information security behavior. Lastly, information security competence and information security behavior were found to be such factors that give influence on information security performance.

The impact on earnings patent technology transfer business performance of the Industry-Academic Cooperation Foundation (산학협력단의 특허실적이 기술이전사업 성과에 미치는 영향)

  • Noh, Seong-Yeo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.394-399
    • /
    • 2016
  • This study examines how the patent results of the University Academic-Industrial Cooperation influence technology transfer. Statistical analysis was performed by using 2013 panel data from the Ministry of Education and Science Technology(MEST) National Research Foundation of Korea(NRF) and the results are as follows. The results show that the patent result factors that have a positive effect on the total number of technology transfers are domestic patent application numbers, foreign patent application numbers, future technology(6T) patent application numbers, science technology patent application numbers. The factors that have a positive effect on increasing royalty are the total number of technology transfers. Domestic patent application numbers, future technology(6T) patent application numbers and science technology patent application numbers have a positive effect on patent results. The results implicate that more research and development is needed for more patents to be applied, that the main focus should be on future technology(6T) and science technology fields, and that effort should be directed at planning negotiation strategies for the term of the contract. However, this study is the need to research, including primary research is so patent performance may be limited in having only been considered in future studies of human and material resources and operating system factors that may be presented to the essential elements of the Industry-Academic Cooperation Foundation this raises.

A Efficient Network Security Management Model in Industrial Control System Environments (산업제어시스템 환경에서 효과적인 네트워크 보안 관리 모델)

  • Kim, Il-Yong;Lim, Hee-Teag;Ji, Dae-Bum;Park, Jae-Pyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.664-673
    • /
    • 2018
  • The industrial control system (ICS) has operated as a closed network in the past, but it has recently been linked to information and communications services and has been causing damage due to cyber attacks. As a countermeasure, the Information Communication Infrastructure Protection Act was enacted, but it cannot be applied to various real control environments because there is only a one-way policy-from a control network to a business network. In addition, IEC62443 defines an industrial control system reference model as an international standard, and suggests an area security model using a firewall. However, there is a limit to linking an industrial control network, operating as a closed network, to an external network only through a firewall. In this paper, we analyze the security model and research trends of the industrial control system at home and abroad, and propose an industrial control system security model that can be applied to the actual interworking environments of various domestic industrial control networks. Also, we analyze the security of firewalls, industrial firewalls, network connection equipment, and one-way transmission systems. Through a domestic case and policy comparison, it is confirmed that security is improved. In the era of the fourth industrial revolution, the proposed security model can be applied to security management measures for various industrial control fields, such as smart factories, smart cars, and smart plants.

A study on Safety Management and Control in Wet-Etching Process for H2O2 Reactions (습식 에칭 공정에서의 과산화수소 이상반응에 대한 안전 대책 및 제어에 관한 연구)

  • Yoo, Heung-Ryol;Son, Yung-Deug
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.650-656
    • /
    • 2018
  • The TFT-LCD industry is a kind of large-scale industrial Giant Microelectronics device industry and has a similar semiconductor process technology. Wet etching forms a relatively large proportion of the entire TFT process, but the number of published research papers on this topic is limited. The main reason for this is that the components of the etchant, in which the reaction takes place, are confidential and rarely publicized. Aluminum (Al) and copper (Cu), which have been used in recent years for the manufacture of large area LCDs, are very difficult materials to process using wet etching. Cu, a low-resistance material, can only be used in the wet etching process, and is used as a substitute for Al due to its high speed etching, low failure rate, and low power consumption. Further, the abnormal reaction of hydrogen peroxide ($H_2O_2$), which is used as an etching solution, requires additional piping and electrical safety devices. This paper proposes a method of minimizing the damage to the plant in the case of adverse reactions, though it cannot limit the adverse reaction of hydrogen peroxide. In recent years, there have been many cases in which aluminum etching equipment has been changed to copper. This paper presents a countermeasure against abnormal reactions by implementing safety PLC with a high safety grade.

A Study for Reliability Improvement of Belt Type Door System using FMECA (FMECA 적용을 통한 벨트식 도어시스템 신뢰성 향상에 관한 연구)

  • An, Cheon-Heon;Lee, Do-Sun;Son, Young-Jin;Lee, Hi-Sung
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.1
    • /
    • pp.58-64
    • /
    • 2010
  • As a modem urban train is getting complex in terms of high-technology in its systems and components, the failure management should be performed with scientific and systematic technique. FMEA is a technique to analyze the failure trends of component parts and influences to the higher level system in order to discover the design incompleteness and potential defects, which is for improving reliability. Especially, FMECA (Failure Mode Effects, and Criticality Analysis) is used in case that the criticality that has an immense influence to the system is important. In case of urban train, in its design and manufacturing steps, FMEA is frequently used as an analysis technique to meet the safety objectives and eliminate potential hazards/failures since the concepts of reliability of train is introduced these days. Though, FMEA technique in the maintenances steps lacks in its investigation and applications yet. FMEA is also not applied to the trains operated by Seoul metro in the design and manufacture steps excepts the newest trains. In this paper, through analyzing the failures/maintenance data of the belt-type door systems used in trains operated in Seoul metro Line 1, which is accumulated in RIMS (Rolling-stock Information Maintenance System), FMEA procedures to the belt-type door engines are proposed. Especially, an effort is made, to approach the detailed FMECA procedures to the door magnet valve and switch and door engine devices which vastly influences the customer safety and satisfaction.

Characteristics of turbid water on watershed in rainy season (하천유역의 강우기 탁수발생 특성)

  • Lee, Yo-Sang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.1944-1947
    • /
    • 2008
  • 강우기에 하천 유역에서의 탁수 발생은 대상 지역의 토양, 토지 이용형태와 식생 분포, 강우의 강도, 토지의 경사 등에 따라 큰 영향을 받게 된다. 본 연구에는 토지의 이용형태에 따른 강우 시 탁수 발생량을 평가하고자 용담댐 유역의 탁수 발생특성 조사를 실시하였다. 2005년의 조사지점은 유역면적이 가장 작은 주자천 유역과 구량천, 금강본류를 대상으로 하였다. 구량천과 금강본류는 용담댐 유역을 구성하는 가장 큰 두 소유역이며 다를 지역에 비해 오염원이 많아 용담댐수질에 많은 영향을 주는 하천이다. 현장조사는 6월 27일부터 7월 3일 까지 실시하였다. 2007년 조사 대상 지역은 주자천 유역의 주천교 지점과 금강본류 유역의 월곡교 지점을 선정하였다. 현장조사는 6월21${\sim}$22일, 9월14${\sim}$15일 2회에 걸쳐 실시하였으며 시간별 현장 탁도 측정 및 시료 채취를 통한 분석을 병행하였다. 2005년에 실시한 조사결과 오염원이 많고 유역이 넓은 천천은 7월 1일에 유입량이 최대로 348.16CMS였으며, 그날 탁도는 오후 2시 10분조사시에 최대 2060NTU를 나타냈다. 구량천은 같은날 조사를 실시하여 유량은 최대 200.33CMS였고, 최대 탁도는 763NTU를 나타냈다. 반면 주자천에서는 최대 탁도가 98.4NTU를 나타내 가장 탁도가 높은 금강본류와는 약 13배의 차이를 나타냈다. 2007년 1차 조사는 6월 21${\sim}$22일에 걸쳐 이루어 졌다. 주천교 지점은 시간최대 강우 17mm가 발생한 시점에 최대 92NTU의 탁도를 나타내었고 그 이후 감소하여 20NTU이하의 탁도를 유지하였다. 반면, 월곡교 지점은 시간최대 23mm의 강우가 발생하였고, 최대 탁도는 3,610NTU에 도달하였으며 1,000NTU이상의 고탁도가 6시간 이상 유지된 후, 시간이 지남에 따라 점차 감소하였다. 이러한 결과는 미개발지역인 주천교 지점의 경우 강우에 의한 탁수 발생이 상대적으로 적음을 보여주고 있으며 월곡교 지점과 같이 개발로 인해 노출된 토양의 경우 강우에 의해 쉽게 침식이 일어나 고탁도의 탁수를 발생시킴을 보여준다. 그러나 주천교지점에서 2005년에 조사한 자료와 비교해 보면 2007년이 적은 강우임에도 불구하고 탁도는 높게 나타난 결과를 나타내고 있으며 이는 토지이용의 고도화에 따른 영향으로 판단되었다. 연구 결과 유역내에서 탁수 발생은 같은 강도의 강우에 있어서 큰 차이를 보이고 있음을 확인할 수 있었다. 따라서 강우기에 저수지에서의 탁수 문제의 해결을 위해서는 상류 유역의 탁수 발생원 관리가 중요함을 보여주고 있으며, 토지 이용 형태에 따른 토양 침식 방지 대책이 강우기의 댐 내 탁도 문제를 개선할 수 있는 중요한 방안으로 판단된다.

  • PDF

Economic Analysis of Dam Operation Improvement by Dam Downstream River Improvement Works (II)-Economic Benefit and Cost Allocation Analysis (댐하류하천정비사업의 댐 운영개선 효과 경제성 분석 (II) -경제적 편익 및 비용분담률 분석)

  • Yoo, Seung-Hoon;Lee, Gwang-Man;Lee, Eul-Rae
    • Journal of Korea Water Resources Association
    • /
    • v.44 no.9
    • /
    • pp.765-776
    • /
    • 2011
  • Flood discharge capacity in a dam downstream reach has been decreased after dam construction because of the river cross section reduction impacted by farm lands, sand-bars and parking lots, etc. in river flood plains. Those obstacles being in the river inside areas have caused negative influences to the dam operation policy. Therefore, the dam downstream river improvement work associated with the dam operation improvement plan is under construction for removing reduction factors on the dam effective storage, assuring flood safety in the dam downstream river and incrementing dam operation benefits. But the project has issued some problems such as project feasibility, economic evaluation, cost allocation and benefit share, etc. Since a dam enterpriser has not committed such kind of project before, it is necessary to set up an objective analysis process and a quantitative financial valuation. This study examines the measurable economic benefits and the cost allocation of the project for the fairness between benefit owners (central government and water electricity enterprisers). As a result, the total economic benefit from 3 dams (Imha, Daechung and Youngdam Dam) accounts for 14.41 Billion Won/year. The financial valuation of K-water as a project enterpriser is approximately estimated at 40% of the total value and the government is 60%.

Vascular Plants in Jinhae-si of Southern Coastal Area (남해안 진해시에 분포하는 관속식물상)

  • You, Ju-Han;Jung, Sung-Gwan;Kim, Kyung-Tae;Choi, Won-Young;Park, Jong-Wan;Kwon, Do-Gyun;Lee, Woo-Sung;Kim, Ji-Sung;Park, Kyung-Hun
    • Korean Journal of Plant Resources
    • /
    • v.20 no.2
    • /
    • pp.155-167
    • /
    • 2007
  • This study was carried out to offer the raw data for environment conservation by surveying and analysing the flora distributed over Jinhae-si, and to present the frame for preparing the method of obtaining the bioresource in approach to plant resource. The period of survey was from May, 2005 to June, 2006, and the routes were A(Mt. Jangbok), B(Ahnmin hill) C(Mt. Hwa). The results as follows. The vascular plants were summarized as 447 taxa; 98 families, 286 genera, 394 species, 49 varieties, and 4 forma. The rare plants designated by Korea Forest Service were 2 taxa; Tricyrtis dilatata and Viola albida. The Korean endemic plants were 11 taxa; Tricyrtis dilatata, Salix caprea, Carpinus coreana, Melandryum seoulense, Clematis trichotoma, Thalictrum uchiyamai, Deutzia coreana, Spiraea prunifolia for. simpliciflora, Lespedeza maritima, Forsythia koreana and Weigela subsessilis.

Analyzing Site Characteristics and Suitability for Wind Farm Facilities in Forest Lands (산지 내 풍력발전단지 입지 특성 및 적합성 분석)

  • Kwon, Soon-Duk;Joo, Woo-Yeong;Kim, Won-Kyung;Kim, Jong-Ho;Kim, Eun-Hee
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.17 no.4
    • /
    • pp.86-100
    • /
    • 2014
  • The purposes of this study are to provide a guideline for the suitability of wind farm facilities in forest lands and to suggest improvement plans of policies and systems to minimize the damage of forest lands. First, we implemented a literature review and field surveys to examine and select factors for the suitability of wind farm facilities in forest lands. Spatial database for selected location factors of wind farm facilities in forest lands was constructed to develop the suitability model for locating wind farm facilities focusing on Gangwon-do. Data used in this study include wind power resource, legal mountainous preserved area, forest roads, developed areas, forest class, and other spatial data. In order to find specific-sized potential areas for a certain number of wind farm turbines, we used block statistics and focal statistics methods. As a result, the areas for potential wind farm locations were 1,261ha from a block statistics method and 1,411ha from a focal statistics method. Based on the outputs of this research, it is required to make an urgent solution for the prevention of forest disaster and to prepare reduction measures for the destruction of ridge landscape.