• Title/Summary/Keyword: 단조증가하중

Search Result 42, Processing Time 0.02 seconds

Seismic Repair of Damaged RC columns with Steel and CFRP Jackets (강판피복과 CFRP를 이용한 손상된 교각의 내진보수)

  • Choi, Sang-Hyun;Lee, Young-Ho;Lee, Hak-Eun;Youm, Kwang-Soo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.3 s.43
    • /
    • pp.69-75
    • /
    • 2005
  • In this paper, the comparative performance of repaired RC columns using steel and CFRP is presented. Also, the effect of transverse reinforcement ratio on the behavior of the steel and the CFRP repairing is investigated. Monotonic and cyclic load tests are conducted on nine RC column specimens with different repairing strategies and transverse reinforcement ratios to compare the load-displacement curves and the hysteretic behaviors. From the tests, it is observed that both steel and CFRP jacket repairings can significantly increase the displacement ductility and the ultimate load capacity of damaged columns.

Effect of Reverse Cyclic Loading on the Fracture Resistance Curve of Nuclear Piping Material (역사이클하중이 원자력 배관재료의 파괴저항곡선에 미치는 영향)

  • Weon, Jong-Il;Seok, Chang-Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.23 no.7 s.166
    • /
    • pp.1112-1119
    • /
    • 1999
  • Fracture resistance(J-R) curves, which are used for the elastic-plastic fracture mechanics analyses, are known to be dependent on the cyclic loading history. The objective of this paper is to study the effect of reverse cyclic loading on J-R curves in CT specimens. The effect of two parameters was observed on the J-R curves during the reverse cyclic loading. One was the minimum-to-maximum load ratio(R) and the other was the incremental plastic displacement(${\delta}_{cycle}/{\delta}_i$), which is related to the amount of crack growth that occurs in a cycle. Fracture resistance test on CT specimens with varying load ratio and incremental plastic displacement were performed. For the SA 516 Gr. 70 steel, the results showed that the J-R curves were decreased with decreasing the load ratio and the incremental plastic displacement. When the load ratio was set to -1, the results of the J-R curves and the $J_i$ value were about $40{\sim}50$ percent of those for the monotonic loading condition. Also on condition that the incremental plastic displacement reached 1/40, the J-R curves and the $J_i$ value were about $50{\sim}60$ percent of those for the incremental plastic displacement of 1/10.

Characterization of Cast-Forging Process in Hypereutectic Al-15wt.%Si alloy

  • Kim, Eok-Soo;Lim, Kyung-Mook;Hong, Young-Myung;Han, Yoon-Sung;Lee, Kwang-Hak
    • Journal of Korea Foundry Society
    • /
    • v.27 no.5
    • /
    • pp.212-216
    • /
    • 2007
  • 과공정 Al-15wt.%Si 합금의 주단조 공정의 적용을 위해 주조 예비성형체를 제작하는 과정에서 P와 Sr을 첨가하여 과공정 Al-Si 합금의 응고과정에서 발생하는 초정 Si과 공정 Si의 미세화 개량처리를 행하였다. 미세화 조직의 변화에 따른 기계적성질 및 단조성을 조사하였으며, 미세화제로 첨가된 0.075wt.% Sr과 0.1wt.% P의 첨가에서 가장 효과적인 미세한 조직을 얻을 수 있었고, 인장강도와 연신율은 이들 첨가원가의 증가에 따라 향상되는 결과를 보였으나 일정 이상의 첨가에서는 더 이상의 향상은 없었다. 단조성 평가를 위한 열간가공 재현실험에서는 $450^{\circ}C$에서 약60N/mm2의 하중이 필요함을 알 수 있었다. 열간단조 및 열처리 후의 인장강도와 연신율은 보다 많은 향상을 가져왔으며, 이는 압축가공에 의한 주조 예비성형체 내부에 잔존하던 주조결함의 제어와 열처리에 의한 조직의 개량 및 균질화 효과에 의한 것으로 판단된다.

Hot Forging Simulation of Outer Tie Rod for Reducing Forming Load (성형하중을 감소시키기 위한 아우터 타이로드의 열간 단조해석)

  • Kim, Young-Jun;An, Kyo-Jin;Lee, Kwon-Hee;Park, Young-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.1652-1657
    • /
    • 2015
  • Recently the improvement in vehicle performance trend to increase in accordance with the weight of this part. Outer tie rod is small when compared to the other vehicle part by weight, but there is a need to reduce the weight of the outer tie rod in order to improve fuel efficiency of the vehicle. Therefore, from previous studies, a model of outer die rod is proposed using Design of Experiments and Meta model satisfying the buckling performance. Outer tie rod are manufactured through forging process, in this study, we compare the size of the forming load in accordance with the change in the moving speed through the die forging analysis of the outer tie rod on the basis of the actual molding process.

An Analytical Study on the Elasto-Plastic Behavior of Reinforced Concrete Structure under Monotonic & Cyclic Load (단조 증가 및 반복 하중을 받는 철근 콘크리트 구조물의 탄소성 거동에 대한 해석적 연구)

  • 김화중;박정민;마은희
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1993.10a
    • /
    • pp.131-138
    • /
    • 1993
  • To analysis machanical behavior for RC frame under monotonic & Cyclic load, it is needed to investigate elasto-plastic behavior for steel & concrete. Therefore, in this study, we idealized material model(steel and concrete) to take into account elasto-plastic, limit state, and developed structural analysis program that consider complex non-linearity. We investigated simple beam and portal frame under cyclic & monotonic loading, so we confirmed the propriety.

  • PDF

An Effect of Steel Corrosion on Bond Stress-slip Relationship under Repeated Loading (반복하중하의 부착응력-슬립 관계에 미치는 철근 부식의 영향)

  • Kim, Chul-Min;Park, Jong-Bum;Chang, Sung-Pil;Kim, Jee-Sang
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.2
    • /
    • pp.179-186
    • /
    • 2010
  • The bond between steel and concrete in reinforced concrete members is essential to resist external load, but the bond mechanism in reinforced concrete beams deteriorated by steel corrosion has not been clearly known yet. Most existing researches have dealt with the bond behavior of corroded steel under monotonic loading, but scarce are researches dealing with bond behavior of corroded steel under repeated loading. This study includes the experimental investigation on the bond behavior with respect to the various degrees of steel corrosion under repeated loading. According to the test results, the bond strength of corroded steel under monotonic loading increases as the rate of steel corrosion increases unless the splitting crack occurs. The slip versus number of load cycles relation was found to be approximately linear in double logarithmic scale, not only in specimens without steel corrosion but also in specimens with steel corrosion. The test results also show that the steel corrosion does not negatively affect the bond strength of corroded steel after repeated loading unless the splitting crack occurs. But the fatigue life decreases sharply after splitting crack occurs. This research will be helpful for the realistic durability design and condition assessment of reinforced concrete structures.

Load-Displacement Relationship of Passive Vibration Units Composed with a Spring and Vibration-Proof Rubbers (스프링과 방진고무가 융합된 제진장치의 하중-변위 관계)

  • Mun, Ju-Hyun;Im, Chae-Rim;Wang, Hye-Rin;Yang, Keun-Hyeok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.226-234
    • /
    • 2021
  • The objective of this study is to establish the fundamental design data for axial load-displacement relationship under axial monotonic or cyclic responses of seismic damping·isolation (SDI) units developed for ceiling structures. The main parameters include the installation of a spring, the number of rubber layer, prestress stress of bolts for connector between the spring and rubbers, and loading type. Test results showed that SDI units with a spring in the core and higher prestress stress of bolts tended to be higher stiffness at the ascending branch and more ductile behavior at the descending branch. This trends more notable for the specimens under monotonic load rather than cyclic loads. Consequently, the energy dissipation of SDI unit can be optimally designed with the following conditions: installation of a spring within 3-layer rubbers and prestress applied to the bolts at 10% of their yielding strength . When compared with the experimental tension capacity of the developed SDI units, the predictions by JIS B 2704-1 and KDS 31 00 are conservative under monotonic loading but higher by approximately 10% under cyclic loading.

An Experimental Study on the Mechanical Properties of Carbon Fiber Reinforced Concrete under Uni-Axial Compression Loading (탄소섬유보강콘크리트의 일축압축재하시의 역학적 특성에 관한 실험적 연구)

  • 부척량;김화중;이상재
    • Magazine of the Korea Concrete Institute
    • /
    • v.2 no.3
    • /
    • pp.55-64
    • /
    • 1990
  • With the increasing use of Fiber Reinforced Concrete as a structural material. More information on its mechanical properties is needed. This paper reports the results of experiments on the behavior of Carbon Fiber Reinforced Concrete under monotonic and cyclic compressive loading. The results are that (1) CFRC does improve its compressive strength by adding fibers to a concrete matrix. (2) Adding any fiber to a concrete matrix produced a substaintial change in its stress-strain response. This change is characterized by a significant increase in ductility as described by the descending portion of the stress-strain curve. (3) As compare with plain concrete, the normalized cyclic behavior of CFRC has a much stability. A higher fiber"" content produes a lesser steep descending portion, which results in a higher ductlity of the material.

Application of Headed Bars with Small Head in Exterior Beam-Column Joints Subjected to Reversed Cyclic Loads (반복하중을 받는 외부 보-기둥 접합부에서 작은 헤드를 사용한 Headed Bar적용)

  • Ha, Sang-Su;Choi, Dong-Uk;Lee, Chang-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.4
    • /
    • pp.411-420
    • /
    • 2007
  • The applicability of headed bars in exterior beam-column joints under reversed cyclic loading was investigated. A total of ten pullout tests were first performed to examine pullout behavior of headed bars subjected to monotonic and cyclic loading with test variables such as connection type between head and bar stem (weld or no weld), loading methods (monotonic or cyclic loading), and head shape (small or large circular head and square head). Two full-scale beam-column joint tests were then performed to compare the structural behavior of exterior beam-column joints constructed using two different reinforcement details: i.e. $90^{\circ}$ standard hooks and headed bars. Both joints were designed following the recommendations of ACI-ASCE Committee 352 for Type 2 performance: i.e. the connection is required to dissipate energy through reversals of deformation into inelastic range. The pullout test results revealed that welded head to the stem did not necessarily result in increased pullout strength when compared to non-welded head. Relatively large circular head resulted in higher peak load than smaller circular and square head. Both beam-column joints with conventional $90^{\circ}$ hooks and headed bars behaved similarly in terms of crack development, hysteresis curves, and peak strengths. The joint using the headed bars showed better overall structural performance in terms of ductility, deformation capacity, and energy dissipation. These experimental results demonstrate that the headed bars using relatively small head can be properly designed far use in external beam-column joint.

Bond Behavior of GFRP Rebars Embedded in Concrete Under Cyclic Loading (반복하중을 받는 GFRP 보강근의 부착특성)

  • Cheong, Yeon-Geol;Yi, Chong-Ku;Lee, Jung-Yoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.101-104
    • /
    • 2008
  • The cost of repairing the deterioration of concrete structures due to corrosion of the reinforcement steel has been the prominent figure in the maintenacne of the reinforced-concrete infrastructures. As an alternative material to steel reinforcement, the use of Fiber Reinforced Polymer (FRP) bar in concrete is being actively studied for the high resistance of chemical environment and high strength to weight ratio properties of FRP. However, there remain various aspects of FRP properties that still need to be studied before the standard design criteria can be established. One of the imminent issues is the bond between FRP and concrete. In this study, the bond-behavior of FRP bars in concrete is investigated via the pullout test with three varying parameters: surface condition of FRP bars, concrete compression strength, and cyclic loading patterns. As a result of experiment, the bond strength of GFRP increased with the concrete compression strength increasing and decreased with applying cyclic load.

  • PDF