• Title/Summary/Keyword: 단열효과

Search Result 264, Processing Time 0.028 seconds

Effects of GTR and Unexpanded Expancel Powders on Thermal Conducting Characteristics of Rigid Polyurethane Foams (GTR 및 미발포 Expancel이 경질우레탄폼의 열전도특성에 미치는 영향)

  • Ahn, Won-Sool
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.6
    • /
    • pp.2846-2851
    • /
    • 2012
  • Effects of ground tire rubber(GTR) and unexpanded $Expancel^{(R)}$ powders on the thermal conducting characteristics of rigid polyurethane foams(PUFs) were studied. Sub-micron sized GTR powders and $Expancel^{(R)}$ powders were used as the foam nucleating agents to improve the thermal insulating properties of the rigid PUFs. As the results, while the thermal conductivities of the GTR filled-PUF samples were increased linearly with GTR contents, those of $Expancel^{(R)}$ filled-PUF samples were decreased a little bit. It was considered from the results that GTR powders might predominantly play a role as the extending fillers. On the other hand, $Expancel^{(R)}$ powders could act as the foam nucleating agents based on the polar surface, showing smaller cell sized PUF with improved insulating characteristics.

An Effect of Surface Dashpot for KC-1 Basic Insulation System Under Sloshing Loads (슬로싱 하중을 받는 KC-1 단열시스템의 표면 완충 효과)

  • Jin, Kyo Kook;Yoon, Ihn Soo;Yang, Young Chul
    • Transactions of the KSME C: Technology and Education
    • /
    • v.3 no.3
    • /
    • pp.193-199
    • /
    • 2015
  • Sloshing of LNG cargo can cause high impact loads on the supporting and containing structures. This is particularly critical for membrane-type tanks since these will have flat surfaces and corner regions which can lead to increased peak pressures for sloshing impacts. The membrane-type containment system is much more flexible compared to the steel hull structure. As a result, fluid-structure interaction plays an important role in the structural analysis of the containment system under sloshing load. This study is based on the direct calculation method of applying sloshing loads to the KC-1 basic insulation system using finite element analysis. The structural analysis of KC-1 basic insulation system considers the dashpot as fluid-structure interaction between liquid cargo and the LNG containment system. The maximum stress of the polyurethane form for KC-1 insulation system is 1.5 times lower than one without dashpot.

A Study on the Energy-saving Variation by the Reduction of Insulation Boundary in Mixed-use Building (주상복합건물에서 단열 경계구역 축소에 따른 에너지 절감량 변화에 관한 연구)

  • Kim, Dae-Won;Kim, Young-Il;Kim, Sung-Min;Cho, Jin-Hwan;Chung, Kwang-Seop
    • Journal of Energy Engineering
    • /
    • v.21 no.2
    • /
    • pp.152-157
    • /
    • 2012
  • Due to the global warming and energy exhaustion, energy efficiency improvement of construction is recognized the stream of times. To improve the efficiency of the building, in order to energy saving, passive elements should be applied. Then the first step be supposed that applying the new standards about the insulation boundary. The current insulation boundary standards are not reasonable as well as does not divide the purposes. As a result, energy is being wasted and many civil complaints are also occurred. To improve these problems, applying the insulation boundary need to divide the heating and non-heating and subdivide the purpose of construction. In this study, accurate real heating and air conditioning areas are presented that work on the new insulation boundary of purposes and applicable standards. This proposed, by the real heating and air conditioning areas, insulation boundary of purposes, matching the reasonable capacity and load of equipment, by working on standards by optimal maintenance can be energy saving, to present guidelines that environment improvement of actual residents as well as energy saving be expected.

Comparative Studies of Thermal Insulation Performance of Life Vests by Numerical Analysis and Experiment (보온 재료에 따른 구명 조끼 별 단열성능의 비교 실험 및 해석)

  • Kim, Sung-Chan;Lee, Kyung-Hoon;Hwang, Se-Yun;Jang, Ho-Sang;Lee, Jang-Hyun
    • Journal of Navigation and Port Research
    • /
    • v.40 no.1
    • /
    • pp.7-14
    • /
    • 2016
  • Although the life jacket can provide the buoyance with the drowner, heat loss can make the drowned individual be subject to the hypothermia. In this study, The thermal insulation of two types life jacket including inflatable and foam type were evaluate by both experiments and numerical analysis. To estimate the thermal resistance of the jackets, experiments on the heat flux were conducted by the thermal manikin exposed to cold water. Heat flux loss on the surface of thermal manikin were measured for both foam and inflatable type life jacket. Also, finite element method is applied to a body section in order to understand the level of hypothermia of each life jacket. The segmental of human thigh is represented by a multi-layered section which considers the heat conduction within tissue, bone and fat. As a result, the thermal resistance and hypothermia time of each jackets have been compared based on the finite element analysis. It was found that the insulation ability of suggested life jackets is better than that of conventional type.

Characteristics of Fracture System in Precambrian Metamorphic Rocks and Mesozoic Granites from Seokmo-do, Ganghwa-gun (강화군 석모도 일대의 선캠브리아기 변성암류 및 중생대 화강암류에서 발달하는 단열계의 분포특성)

  • Park, Deok-Won;Lee, Chang-Bum
    • The Journal of the Petrological Society of Korea
    • /
    • v.19 no.2
    • /
    • pp.123-139
    • /
    • 2010
  • The properties of fracture system in Precambrian Jangbong schist and Mesozoic granites from Seokmo-do, Ganghwa-gun were investigated and analyzed. Most of the fractures measured at outcrops are nearly vertical or steeply dipping. Orientations of fracture sets in terms of frequency order are as follows: Set $1:N2^{\circ}E/77^{\circ}SE$, Set $2:N17^{\circ}E/84^{\circ}NW$, Set $3:N26^{\circ}E/64^{\circ}SE$, Set $4:N86^{\circ}W/82^{\circ}SW$, Set $5:N80^{\circ}W/77^{\circ}NE$, Set $6:N60^{\circ}W/85^{\circ}SW$, Set $7:N73^{\circ}E/87^{\circ}NW$, Set $8:N82^{\circ}W/53^{\circ}NE$, Set $9:N23^{\circ}W/86^{\circ}SW$, Set 10: $N39^{\circ}W/61^{\circ}NE$. Especially, the rose diagram of fracture strikes(N:240) indicates that there are two dorminant directions of N-S~NNE and WNW. These distribution pattern of fractures from Seokmo-do correponds with those of major lineaments from South Korea suggested in previous study. Meanwhile, the scaling properties on the length distribution of fracture populations have been investigated. First, fracture sets from Precambrian Jangbong schist and Mesozoic granites(north and south rock body) has been classified into five groups(group I~V) based on strike and frequency. Then, the distribution chart generalized the individual length-cumulative frequency diagram for above five groups were made. From the related chart, five subpopulations(group I~V) that closely follow a power-law length distribution show a wide range in exponents(-0.79~-1.53). These relative differences in exponent among five groups emphasizes the importance of orientation effect. From the related chart, the diagram of group III occupies an upper region among five groups. Finally, the distribution chart showing the chracteristics of the length frequency distribution for each rock body were made. From the related chart, the diagram of each rock body shows an order of porphyritic biotite granite < hornblende granodiorite < medium-grained biotite granite(south rock body) < medium-grained biotite granite(north rock body) < Precambrian Jangbong schist. From the related chart, the diagram of more older rock body in the formation age tends to occupy an upper region. Especially, the diagram of Precambrian Jangbong schist occupies an upper region compared with the diagrams of Mesozoic granites. These distributional chracteristics suggests that coexistence of new fracture initiation and growing of existing fractures corresponding with stress field acted since the formation of rock body.

A Fundamental Study on Development of a Wall Structure type Thermal Diode for Energy Saving (에너지 절약을 위한 벽체형 열다이오드 개발에 관한 기초)

  • Pak, E.T.;Chang, Y.G.;Chea, S.S.
    • Solar Energy
    • /
    • v.17 no.3
    • /
    • pp.67-73
    • /
    • 1997
  • In order to development of a new wall structure type thermal diode for energy saving, the numerical studies have been performed for natural convection across an rectangular enclosure with the various lengthes of the heat source and sink plate. The governing equations for the two-dimensional, laminar, natural convection process in an enclosure are discretized by the control volume approach which insures the conservative characteristics to be satisfied in the calculation domain, and solved by a elliptic SIMPLE algorithm. The momentum and energy equations are coupled through the buoyancy term.

  • PDF

Coating of heat-acupuncture needle using an $Al_2O_3$ material to improve a heat insulation (한방침의 단열효과를 위한 $Al_2O_3$를 이용한 코팅연구)

  • Chung, Hyup-Jae;Rhee, Kyong-Yop
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.4
    • /
    • pp.114-119
    • /
    • 2009
  • In this research, heat-acupuncture needle was coated with $Al_2O_3$ by applying a plasma spray coating method to prevent a skin burn. $Al_2O_3$, which is one of the representative bioceramics, does not have an influence on the chemical change in the body system. The ceramic coating thickness was about $100{\mu}m$. The experiments of heat conduction were performed for uncoated needle and coated needle. The results showed that the surface temperature of needle decreased as the needle was coated with $Al_2O_3$. The surface temperature of uncoated needle was about $48^{\circ}C$, while that of needle coated with $Al_2O_3$ was about $39^{\circ}C$.

Estimation on the Durability of Metakaolin Concrete According to the W/B Ratio (물결합재비를 달리하여 제작한 메타카올린 혼입 콘크리트의 내구성능 평가)

  • Kim, Chun-Ho;Kim, Nam-Wook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.4
    • /
    • pp.84-91
    • /
    • 2014
  • In this study, in order to find the improvement effect of metakaolin for using improvement of strength in concrete structures, it is investigated the diffusion coefficient of chloride ions and adiabatic temperature rise test. As a result, due to the mixing of metakaolin, it has been confirmed reducing diffusion coefficient of chloride ions and could prevent down of slump for use of adding fly ash. Therefore, ensuring resistance to chloride ion penetration into concrete, it is possible to enlarge the W/B ratio and reduce the adiabatic temperature rise by mixing of metakaolin. So, it is confirmed that the durability of concrete structures is increased.

Analysis of the Energy Saving Effect for the External Insulation Construction by Building Load Calculation Method (건물 부하계산 프로그램을 이용한 외단열 시공의 에너지 절감 효과 분석)

  • Park, Jaejoong;Myeong, Jemin;Song, Doosam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.3
    • /
    • pp.97-104
    • /
    • 2017
  • Reinforcement of insulation in apartment buildings reduces the heating and cooling energy consumption by lowering the heat transfer in the building envelope. There are differences between internal and external insulation methods in heat transmission properties. However, some building load calculation programs cannot analysis the differences between the two. This is because these programs do no account for the timelag or thermal storage effect of the wall according to the location of insulation. In this study, the heat transmission characteristics of internal and external insulation were analyzed by EnergyPlus, and heating and cooling energy demand was compared. The results showed that external insulation system had lower heating and cooling loads than internal insulation system. Also the heat transfer rate of external insulation is steadier than internal insulation. About 13.6% of heating and cooling energy demand decreased when the outdoor wall was finished with external insulation compared to the demand with internal insulation.

An Alternative Effectiveness Analysis on Anti-Dew Road Sign (도로표지판의 결로 방지 대안별 효과 분석)

  • Park, Jae-Hong;Yun, Duk-Geun;Sung, Jung-Gon;Kang, Weon-Eui
    • International Journal of Highway Engineering
    • /
    • v.14 no.2
    • /
    • pp.55-61
    • /
    • 2012
  • Road signs are important facilities in terms of providing information to driver, they are helpful for driver's judgment as deliver it's own information. However if there is occurrence dew on the road sign because of the change of temperature and humidity, it can be cause of accidents. Therefore it is necessary to develop anti-dew or dew resistance technology. In this research the anti-dew technologies such as insulation road sign and anti-dew film were compared with normal road sign, and the effectiveness analysis was conducted for each alternatives. The quantity of dew on the road sign was check using ANOVA and Tukey HSD and the relation between the retro-reflectivity and quantity of dew on the sign was check using Pearson correlation coefficient. As a result, the sample of anti-dew film attached road sign showed lesser quantity of dew compared with normal road sign. After 90 seconds, the difference of dew quantity for anti-dew film and insulation road sign showed statistically significant result. The relation of between quantity of dew and retro-reflectivity was inverse correlation. As a result, when analyzed the quantity of dew and retro-reflectivity a point of view anti-dew effectiveness, the anti-dew film and insulation road sign showed meaningful result.