• Title/Summary/Keyword: 단열효과

Search Result 264, Processing Time 0.022 seconds

Structural Load Bearing Capacity of Wall System Framed by Studs and Runners using Square Steel Tubes (각형강관을 이용한 스터드-런너 골조형 벽체시스템의 구조내력 성능평가)

  • Kim, Ho Soo;Hong, Seok Il;Lim, Young Do
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.3 s.76
    • /
    • pp.253-262
    • /
    • 2005
  • Because the framed wall system using steel studs and runners with square steel tubes as structural elements is reinforced by the horizontal members called runners, it has more strength and load bearing capacity than the steel house wall system. Also, this system improves adiabatic and sound insulation performance by filling up the autoclaved lightweight concrete. We need to evaluate load bearing capacity according to the axial load and lateral load in case this system is applied in the housing system with 3~5 stories through variations in intervals for the runners under the placement effect of autoclaved lightweight concrete. Therefore, this study seeks to analyze axial and shear behavior of the framed wall system according to the placement effect of autoclaved lightweight concrete, and to secure safety for the vertical and lateral loads.

Ignition Suppression in Hydrogen/Air Mixtures Inhibited by Heptafluoropropane (HFP를 첨가한 수소/공기 혼합기의 발화억제)

  • Lee, Eui-Ju;Oh, Chang-Bo
    • Fire Science and Engineering
    • /
    • v.22 no.3
    • /
    • pp.234-238
    • /
    • 2008
  • Autoignition suppression of hydrogen/air premixed mixtures by $CF_3CHFCF_3(HFP)$ was investigated computationally. Numerical simulation was performed in isobaric and homogeneous system to evaluate the induction times. The detailed chemistry of 93 species and 817 reaction mechanism was introduced for hydrogen/air/HFP mixtures. The result of pure hydrogen/air mixture show that the resulting value of induction time depends relatively weakly on the definition used event though there are various criteria for defining the induction time such as the inflection of temperature, OH and $O_2$ concentrations generally. Also, the autoignition temperature of $H_2/air$ mixture is estimated to about 850K, which is corresponds to the literature value. In the case of HFP addition in $H_2/air$ mixture, the results shows that there are several inflection points of radical concentration, and hence it might be to use the temperature for defining ignition delay. When HFP is added to stoichiometric $H_2/air$ mixture, the effect of ignition delay is outstanding above 10% HFP concentration. As HFP concentration increases, both dilution and chemical effects contribute to delay the ignition. Also, the chemical effect on the ignition delay is more considerable with the higher HFP concentration.

A Numerical and Experimental Study of Heat Transfer through a Double Pane Window to Enhance Thermal Insulation of Building (건물 에너지 절약을 위한 수치해석적/실험적 이중창 열전달 연구)

  • 장동순;송은영;이상일
    • Journal of Energy Engineering
    • /
    • v.1 no.1
    • /
    • pp.66-75
    • /
    • 1992
  • The performance of heat transfer through double pane window has been investigated using experimental and numerical methods. The range of the gap distance between glasses are 0.5-10 cm. The convection heat transfer plays the dominant role for the case of the wide gap distance together with the large Rayleigh number and thereby, reduces the enhanced thermal resistance due to the increased air gap, while the conduction heat transfer does the major role for the case of small gap distance. In order to enhance the thermal insulation of the double pane window, the heat transfer of triple pane window, which is constructed to put one more glass at the middle of the double pane, is investigated to check the reduction of the convection heat transfer together with the effect of the radiation shield due to the presence of the additional glass. Further, a spacer is installed at the middle height of the double pane, and the effect of which on the suppression of the convective heat transfer is analyzed carefully, using experimental and numerical methods. For the case of the spacer-installation, the amount of energy saving is considered about 10%, but the energy saving increases a lot to 30-50% for the case of triple pane window, due to the substantial radiation shield effect of the presence of the additional glass.

  • PDF

Study on the Effect of Thermal Stratification on DME/n-Butane HCCI Combustion (열적성층화가 DME/n-Butane 예혼합압축자기착화연소에 미치는 영향에 관한 연구)

  • Lim, Ock-Taeck
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.12
    • /
    • pp.1035-1042
    • /
    • 2010
  • The thermal stratification effect has been thought as one of the way to avoid dramatically generating the heat from HCCI combustion. We investigate the effect of thermal stratification on HCCI combustion fueled by DME and n-Butane. The thermal stratification occurs in a combustion chamber of a rapid compression machine with premixture by buoyancy effect that is made of fuel and air. The premixture is then adiabatically compressed, and during the process, the in-cylinder gas pressure is measured and two-dimensional chemiluminescence images are prepared and analyzed. Under the thermal stratification, the LTR starting time and the HTR starting time are advanced than that of homogeneous case. Further, the LTR period and the luminosity duration under homogeneous conditions are shorter than the corresponding quantities under stratified conditions. Additionally, under stratified conditions, the brightest luminosity intensity is delayed longer than that of homogeneous condition.

A Study on the Thermal Conductivity Measurement for Planting Mats of Landscaping (조경용 식생매트의 열전도율 측정에 관한 연구)

  • Cha, Uk Jin;Yang, Geon Seok
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.46 no.6
    • /
    • pp.85-96
    • /
    • 2018
  • Developed nations have implemented various policies to reduce greenhouse gases since the 1997 Kyoto Protocol in order to minimize the effects of global warming. Korea should also reduce energy consumption in the industrial sector, and the transportation and building sectors in order to achieve its greenhouse gas reduction target of 37 percent compared to the Business As Usual levels. The government implements various laws and regulations for reducing energy consumption. To reduce energy consumption in the building sector, in particular, the Energy Conservation Design Standards are enforced according to the 'Enforcement Support for Green Building Construction'. The amount of electricity used to maintain room temperature at $28^{\circ}C$ in these buildings have a 30% reduction (measured on the walls and rooftop) in power usage compared to buildings not required to meet these standards. Although the effect of these energy savings on landscaping is proven, this demonstration is not effective for energy saving since it is not a suitable method for the 'Energy Saving Design Standards of Buildings'. For landscaping to be effective as far as a component of energy reduction, the perfusion rate of the building should be calculated based on the thermal conductivity of the component materials for the energy saving designs with respect to the basis of Article 14 of the Green Building Act. Therefore, the purpose of this study is to ensure that the planting-based mats currently being widely used in the landscape industry can have insulating performance suitable for the 'Energy Saving Design Standards' of Buildings according to the 'Enable Green Building Construction Methods'.

Experimental Study of Liquid Oxygen Sub-cooling by Helium Injection (헬륨분사를 통한 액체산소 과냉각에 관한 실험적 연구)

  • Kwon Oh-Sung;Cho Nam-Kyung;Chung Yong-Gahp;Ha Seong-Up;Lee Joong-Youp;Kim Hyun-Joong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • v.y2005m4
    • /
    • pp.179-182
    • /
    • 2005
  • Test of liquid oxygen sub-cooling by helium injection, which is one of the method of temperature conditioning of cryogenic propellant in liquid propulsion rocket, is performed. The sub-cooling effect at different He injection flow rate with the same initial liquid oxygen mass is compared. Test results showed liquid oxygen temperature decrease of $5\sim6^{\circ}C$ under test condition. And the required time for cooling is inversely proportional to He injection flow rate.

  • PDF

Engineering Characteristics of the Light Weight Soil Used Recycled Stylofoam Beads and Disposal Soils (폐스티로폴 입자와 현장 발생토를 활용한 경량혼합토의 공학적 특성)

  • Shin, Bang-Woong;Lee, Jong-Kyu
    • Journal of the Korean GEO-environmental Society
    • /
    • v.1 no.1
    • /
    • pp.43-50
    • /
    • 2000
  • This paper presents the engineering property of light weight soil made of soil mixed with recycled stylofoam and stabilizer. Recycled stylofoam beads is able to use by lightweight fill materials because it is light, adiabatic, and effective for vibration interception. Especially, recycled stylofoam beads is easy to supply because stylofoam have been recycle item in 1996. In this study, physical and geotechnical properties of the light weight mixed soil(weathered granite soil mixed with Stylofoam Beads) were analyzed by laboratory experiments to examine its suitability for backfill materials. Laboratory tests were performed to evaluated strength, bearing capacity, weight, permeability, microphotograph analysis with variation of mixing ratio. Based on the results, it is concluded that the use of recycled stylofoam beads is acceptable lightweight fill.

  • PDF

A Study on the Design Technique for Energy Performance Indicators of Existing Office Buildings (기존 오피스건물 에너지성능지표에 따른 설계기법 연구)

  • Jung, Hyungtae;Lee, You Na;Kim, Insoo;Ahn, Jong-Wook
    • Journal of Energy Engineering
    • /
    • v.27 no.3
    • /
    • pp.28-35
    • /
    • 2018
  • Guidelines and institutional support for buildings are being promoted around the world as measures for environmental pollution and energy conservation. In Korea, standards are prepared according to the energy saving design standards of new buildings as amended in 2013.09.01 and the zero energy building for new buildings mandatory process is being prepared from the recommendations. Nevertheless, the government's binding power on smaller buildings is insufficient. Energy savings were analyzed for the recently constructed office buildings (application of external insulation technique) and propose a dual envelope techniques were proposed for energy reduction.

Preparation of Alumina Sol Coated BOPP Composites and Their Gas Permeation Characteristics (Alumina Sol을 코팅한 BOPP 복합체의 제조 및 기체 투과 특성)

  • Hong, Seong-Uk;Oh, Jae-Won;Ko, Young-Deok;Song, Ki-Chang
    • Membrane Journal
    • /
    • v.19 no.1
    • /
    • pp.19-24
    • /
    • 2009
  • Sol-gel process is relatively simple, easy to use, cheap to install, and results in thin coating layers with superior physical and gas barrier properties. Films coated by the sol-gel process can be used as insulating films or packaging films for foods, chemicals, drugs, and beverages, etc. In this study, alumina sol was synthesized from aluminum isopropoxide and silane coupling agent was added to make coating solutions. In addition, biaxially oriented polypropylene (BOPP) was coated using several alumina sol solutions and their oxygen permeabilities were measured. The experimental results indicate that in the best case, the oxygen permeability of coated film was reduced by 85% compared to that of pure BOPP.

Compaction and Leaching Characteristics of the Light Weight Soil Used Recycled Styrofoam Beads and Disposal soils (폐 Styrofoam 혼합토의 다짐 및 용출 특성)

  • Shin, Bang-Woong;Lee, Bong-Jik;Lee, Jong-Kyu
    • Journal of the Korean GEO-environmental Society
    • /
    • v.3 no.2
    • /
    • pp.61-70
    • /
    • 2002
  • This paper presents the engineering property of light weight soil made of soil mixed with recycled Styrofoam and stabilizer. Recycled Styrofoam is widely used for lightweight fill material because it has important geotechnical characteristics which are light, adiabatic, and effective for vibration interception. It is very easy to get the disposal styrofoam. For this study, dynamic compaction test, static compaction test and pH and leaching tests were performed. Based on the test results, it is concluded that the static compaction method is recommened to prevent from crushing materials and pH values of embankment materials are satisfied with these of domestic and RCRA configuration.

  • PDF