• Title/Summary/Keyword: 단열효과

Search Result 264, Processing Time 0.026 seconds

Characterization of Insulation Finish Material Using Inorganic Wet Treatment Fly Ash (무기성 습식 처리 플라이애시를 활용한 단열 외피 마감재의 특성 평가)

  • Ryu, Hwa-Sung;Shin, Sang-Heon;Song, Sung-Young;Kim, Deuak-Mo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.4
    • /
    • pp.389-394
    • /
    • 2019
  • In this study, a functional inorganic insulation as TiO2 and inorganic wet fly ash were used to evaluate the physical performance and thermal environment of an exterior finish that can improve the thermal environment of a building. The performance evaluation of the finish was based on the KS F 4715 thin coating material and the thermal environment. When TiO2 was added, the physical performance was lowered at 10% or more, and the inorganic wet-treated fly ash increased the physical performance by 10%. In the thermal environmental evaluation, the surface temperature reduction effect of the inorganic wet-treated fly ash was low, but when used in combination with TiO2, it was effective to reduce the surface temperature and the internal temperature. As a result, the optimum combination of TiO2 and inorganic wet-treated fly ash for thermal environment control was found to be optimal when 5% of each mixture was used.

Bench Scale Performance Test of WGS and $CO_2$ PSA for $H_2$ Recovery from Syn Gas (합성가스로부터 수소회수를 위한 WGS 및 $CO_2$ PSA 성능평가)

  • Jeong, Seong-Jae;Cha, Jae-Jun;Kim, Young-Suk
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.206.1-206.1
    • /
    • 2010
  • 폐기물 등을 열분해 가스화한 합성가스로부터 효과적으로 고순도의 수소를 회수하기 위하여 WGS(수성가스전환반응) 및 $CO_2$ 회수 PSA 공정을 적용하였다. 벤치스케일 열교환형 WGS반응기를 개발하여 기존 단열방식에 비하여 단순화한 반응시스템을 구축하였으며 출구 CO농도 4%대를 달성하였다. 또한 3베드로 구성된 벤치스케일의 $CO_2$ PSA운전을 수행한 결과, 2.5barg 흡착 및 진공재생단계를 적용하여 회수되는 $CO_2$의 농도가 95%이상, 회수율 80%이상을 기록하는 효율적인 $CO_2$ 회수공정을 개발하였다. 한편, 흡탈착 모사프로그램인 ADSIM을 통해서도 실험과 비교적 일치한 결과를 얻을 수 있었는데 향후 스케일업 설계자료 확보시 유용할 것으로 판단되었다.

  • PDF

Surface Temperature Control of an Insulated Horizontal Pipe under Thermal Radiation Environment (복사효과를 포함하는 수평관 표면의 온도제어)

  • Kang, Byung-Ha;Pi, Chang-Hun;Kim, Suk-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.1
    • /
    • pp.54-60
    • /
    • 2011
  • Procedures for estimation of insulation thickness for a horizontal pipe for condensation control or personnel protection has been investigated, parallel to the previous work of a vertical wall case. Parameters include pipe diameter, emissivity, thermal conductivity, and operating temperatures. The results indicated that the surface emissivity plays a very important role in the design of insulation, specially for the case of high temperature application with low Bi. The effect of surface radiation in such case could be up to 65% of the total. Required insulation thickness for the surface temperature control increases as pipe diameter increases and as surface emissivity decreases. Adequate revision of specifications or standards to include newly invented insulation materials with high emissivity has been also suggested.

이슈 & 이슈 - 원하는 만큼 고쳐쓰는 '아파트 리모델링'

  • 대한설비건설협회
    • 월간 기계설비
    • /
    • s.277
    • /
    • pp.48-55
    • /
    • 2013
  • 국토교통부(장관 서승환)는 수직증축 리모델링 허용 등을 포함한 '공동주택 리모델링 제도개선 방안'(6.5 발표)의 후속조치로 노후 공동주택 거주 주민이 부담 가능한 범위에서 불편사례를 선택적으로 개선할 수 있도록 '맞춤형 리모델링' 활성화를 위한 연구용역을 마무리하고, 조만간 가이드라인을 제작 발표할 계획이라고 밝혔다. 가이드라인에는 주차장 부족, 배관 노후화 등 노후 공동주택 거주 주민들의 주요 불편사항(급 배수관 노후화, 주차장 부족, 난방효율 저하, 승강기 부족 등)을 효과적으로 해소할 수 있도록 단지 동 세대 내에서 각각 시행할 수 있는 총 39가지의 리모델링 아이템에 대한 소개와 공사비 등의 정보가 포함될 예정이다. 먼저, 단지내 리모델링에는 데크 지하주차장 신설, 녹지 보육시설 및 헬스장 등 확충, 노후상가 철거 후 별동 증축 등이 포함되며, 아파트 개별 동 내에서는 급 배수관/전기 통신/소방 등 노후 설비 교체, 승강기 신설, 코어증축(복도${\rightarrow}$계단식 변경) 등이, 세대 내에는 문 창호 및 내장재 교체, 단열 기밀 등 에너지 성능 향상, 실내공간 재배치 등이 포함된다. 특히, 아이템별 이주기간을 재실형과 이주형으로 구분하여 주민 선택의 폭을 한층 더 넓힐 것으로 기대된다.

  • PDF

Study on Coherent Anti-Stokes Raman Spectroscopy for Measuring Temperature Profile in a Flame (CARS를 이용한 화염내부 온도분포 측정연구)

  • 한재원;박승암;이은성;이충희;강경태;정석호
    • Korean Journal of Optics and Photonics
    • /
    • v.3 no.4
    • /
    • pp.266-272
    • /
    • 1992
  • A coherent anti-Stokes Raman spectroscopy (CARS) technique is applied to measure temperature profile in a flame. The CARS signal is obtained with BOXCARS phase matching to get better spatial resolution. A program routine for calculating temperature of the flame from the measured CARS spectra is studied. The routine includes the line broadening mechnism of the molecules described with a modified energy gap (MEG) law by using the perturbation theory. We have found that the temperature profile obtained with the MEG law is properly fit with the results measured with a thermocoulpe and calculated with the adiabatic theory.

  • PDF

Development of Energy Efficient Smart Module with Variable Direction of Heat Flow, Heat Capacity and Surface Absorptivity (Thermo-Diode식 태양열 이용 모듈(Smart Module)개발)

  • Lee, K.J.;Chun, W.G.
    • Solar Energy
    • /
    • v.18 no.3
    • /
    • pp.119-128
    • /
    • 1998
  • This study has been carried out to develop a thermo-diode system capable of adjusting heat flow direction, solar absorptivity and thermal capacity. What we call "Smart Module" here has emerged from a series of repeated processes involving design, construction and test. In all, it is found that liquid thermo-diode systems are viable in harnessing the sun's energy. The module can be applied for space heating in winter and reduce the cooling load of buildings in summer.

  • PDF

Broadband Interference Patterns in Shallow Water with Constant Bottom Slope (해저면 경사가 일정한 천해에서의 광대역 간섭 유형)

  • 오철민;오선택;나정열;이성욱
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.5
    • /
    • pp.485-493
    • /
    • 2002
  • Broadband interference patterns are studied using ship as an acoustic source in shallow waters with varying bathymetry. Waveguide invariant index (β) indicating the pattern of constructive (or destructive) interference in range-frequency domain is derived in a waveguide with constant bottom slope based on adiabatic mode theory. Using this invariant, changes of the interference patterns resulting from the variation of bottom bathymetry are analyzed. Results of the analytic interpretation is compared with those from sea experiments and numerical simulations.

A Study on the Flame Retardant Effect for Metal Complexes-Cellulose Hybrid Insulator (금속착물-셀룰로오스 복합 단열재의 난연 효과 연구)

  • Kim, Hong;Kang, Young-Goo
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.3
    • /
    • pp.62-67
    • /
    • 1995
  • The combustion characteristics of cellulose Insulation treated with several metal complexes such as Aluminium hydroxide, Cupric sulfate pentahydrate, Magnesium sulfate heptahydrate, Manganese chloride tetrahydrate and Tnisodium phosphate dodecahydrate are studied to evaluate the effectiveness as a potential flame retardant for cellulosic materials. In this study, we found that LOI values of cellulosic materials treated with the metal complexes are generally increased with the increase of their content. At high concentration, CS(24% ) and SP(24% ) show high LOI values, suggesting resistance to flame spread, The materials examined in this study were found to be relatively more resistance to smouldering and flaming combustion in comparision with untreated cellulosic material. The flammability behavior of the materials exhibits combustion process as follows : LOI$\rightarrow$smouldering region$\rightarrow$smouldering-flaming spread region$\rightarrow$flame spread region.

  • PDF

Adiabatic wall temperature distribution on a plate as under-expanded ratio and impinging angle (과소팽창비와 경사각에 따른 평판에서의 단열벽면온도분포)

  • Sun Yu Man;Cho Hyung Hee;Hwang Ki Young;Bae Ju Chan;Lee Jang Woo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.113-118
    • /
    • 2004
  • Experiments are conducted to get basic information of under-expanded impinging jet in the near field. Experimental parameters are impinging angle and under-expanded ratio. As the under-expanded ratio increases, the maximum surface pressure decreases and the reducing effect of recovery factor increases. As the impinging angle decreases, the peak of surface pressure is displaced slightly from the geometric center of the plate to the upward region and the cooling region is expanded in the downward region, whereas it is contracted in the upward region.

  • PDF

Improving Groundwater Recovery by Hydrofracturing (인공수압파쇄기법에 의한 지하수 양수량 증대)

  • 한정상;안종성;윤윤영;김형수;백건하
    • Journal of Soil and Groundwater Environment
    • /
    • v.7 no.2
    • /
    • pp.23-33
    • /
    • 2002
  • There are two case history. One is the case of 3 wells-group well system-drilled and artificially hydrofractured for dewatering to help to excavate and treat deep building foundation. The recoveries of groundwater of 3 wells are increased 29%, 42% and 110% respectively through hydrofracturing. Simultaneous pumping test reveals that 3 wells are geohydrologically interconnected considering lowered specific capacity comprising influence of additional drawdown effect by other 2 wells compared to single well test. Response time effect during single well test shows that dorminant lineaments are more expandable to other geological structures. The other one is the case of 28% increasing of groundwater productivity for domestic use by hydrofracturing.