• Title/Summary/Keyword: 단열온도 상승 특성

Search Result 77, Processing Time 0.025 seconds

Properties of Adiabatic Temperature Rising of Concrete Using Coal Gasification Slag as Fine Aggregate (석탄 가스화 용융 슬래그를 잔골재로 사용한 콘크리트 단열온도상승 특성)

  • Han, Jun-Hui;Lim, Gun-Su;Chi, Il-Kyeung;Kim, Jung;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.114-115
    • /
    • 2021
  • The research team conducted a series of studies to use CGS as fine aggregate for concrete. In this paper, through the adiabatic temperature rising test, CGS' hydration heating performance and its usability as a mass concrete hydration heating agent were reviewed. According to the analysis, the maximum temperature of the mix of OPC 100 was 53.7℃, and the temperature of CGS 50% was 45.2℃, which was 8.5℃ lower than the OPC 100.

  • PDF

Models for Hydration Heat Development and Mechanical Properties of Ultra High Performance Concrete (초고성능 콘크리트의 수화발열 및 역학적 특성 모델)

  • Cha, Soo-Won;Kim, Ki-Hyun;Kim, Sung-Wook;Park, Jung-Jun;Bae, Sung-Geun
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.3
    • /
    • pp.389-397
    • /
    • 2010
  • Concrete has excellent mechanical properties, high durability, and economical advantages over other construction materials. Nevertheless, it is not an easy task to apply concrete to long span bridges. That's because concrete has a low strength to weight ratio. Ultra high performance concrete (UHPC) has a very high strength and hence it allows use of relatively small section for the same design load. Thus UHPC is a promising material to be utilized in the construction of long span bridges. However, there is a possibility of crack generation during the curing process due to the high binder ratio of UHPC and a consequent large amount of hydration heat. In this study, adiabatic temperature rise and mechanical properties were modeled for the stress analysis due to hydration heat. Adiabatic temperature rise curve of UHPC was modeled superposing 2-parameter model and S-shaped function, and the Arrhenius constant was determined using the concept of equivalent time. The results are verified by the mock-up test measuring the temperature development due to the hydration of UHPC. In addition, models for mechanical properties such as elastic modulus, tensile strength and compressive strength were developed based on the test results from conventional load test and ultrasonic pulse velocity measurement.

Hydration Heat Properties of High Flowing Self-Compacting Concrete with Normal Strength (보통강도 고유동 자기충전 콘크리트의 수화발열 특성)

  • Choi, Yun-Wang;Kim, Byoung-Kwon;Lee, Jae-Nam;Ryu, Deug-Hyun;Song, Yong-Kyu;Jung, Woo-Yong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.497-500
    • /
    • 2008
  • This research carries out experiments for hydration exothermic rate and adiabatic temperature rise of concrete to examine the characteristics of the hydration heat of high flowing self-compacting concrete with a normal strength. As a result of the hydration exothermic rate experiment, the high flowing self-compacting concrete that used Lime stone powder and fly ash as polymers shows that its hydration heat amount reduces due to the reduction of unit cement. The result measured the adiabatic temperature rise of concrete presents that high flowing self-compacting concrete having lots of binder contents has a good performance in temperature reduction due to the effect of polymer and that triple adding high flowing self-compacting concrete has a similar temperature rise speed with conventional concrete. As a result of the research, high flowing self-compacting concrete shows a better temperature reduction performance for the binder content per unit than conventional concrete. In addition, it is judged that triple adding high flowing self-compacting concrete with a specified concrete strength 30 MPa is more beneficial in temperature reduction and early hydration heat than double adding high flowing self-compacting concrete.

  • PDF

Mathematical Modeling of Degree of Hydration and Adiabatic Temperature Rise (콘크리트의 수화도 및 단열온도상승량 예측모델 개발)

  • 차수원
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.1
    • /
    • pp.118-125
    • /
    • 2002
  • Hydration is the main reason for the growth of the material properties. An exact parameter to control the chemical and physical process is not the time, but the degree of hydration. Therefore, it is reasonable that development of all material properties and the formation of microstructure should be formulated in terms of degree of hydration. Mathematical formulation of degree of hydration is based on combination of reaction rate functions. The effect of moisture conditions as well as temperature on the rate of reaction is considered in the degree of hydration model. This effect is subdivided into two contributions: water shortage and water distribution. The former is associated with the effect of W/C ratio on the progress of hydration. The water needed for progress of hydration do not exist and there is not enough space for the reaction products to form. The tatter is associated with the effect of free capillary water distribution in the pore system. Physically absorption layer does not contribute to progress of hydration and only free water is available for further hydration. In this study, the effects of chemical composition of cement, W/C ratio, temperature, and moisture conditions on the degree of hydration are considered. Parameters that can be used to indicate or approximate the real degree of hydration are liberated heat of hydration, amount of chemically bound water, and chemical shrinkage, etc. Thus, the degree of heat liberation and adiabatic temperature rise could be determined by prediction of degree of hydration.

Numerical analysis of solar pond with insulation layer (단열층을 가지는 솔라 폰드의 수치해석)

  • Yu, Jik-Su;Mun, Soo-Beom
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.4
    • /
    • pp.264-269
    • /
    • 2016
  • This paper reports a fundamental study of temperature characteristics of a solar pond with an insulation layer. Further, these characteristics were compared with those of a solar pond without the insulation layer. The governing equation was discretized via finite difference method. The governing equations are two-dimensional unsteady-state second-order partial differential equations. The conclusions of the study are as follows: 1) If the depth of the solar pond was increased, the desired effect of increase in temperature was not produced because the amount of solar insolation received by the bottom of the solar pond decreased. 2) As the temperature of the soil during winter is higher than the temperature of the water in a solar pond, heat was transferred from the soil to the solar pond. 3) For the case of the solar pond with insulation layer, it was estimated that the dependence rate of solar energy was 83.3% and that of the boiler was 16.7%.

A Comparative Study on Strength Development, Chloride Diffusivity and Adiabatic Temperature Rise of Marine Concrete Depending on Binder Type (결합재 종류에 따른 해양 콘크리트의 강도 발현, 염화물 확산 및 단열온도 상승 특성에 대한 비교 연구)

  • Bae, Jun-Young;Cho, Sung-Hyun;Shin, Kyung-Joon;Kim, Yun-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.4
    • /
    • pp.411-418
    • /
    • 2013
  • Recently, in order to reduce a damage of chloride attack and hydration heat in marine concrete structures, blended cement in mixing the marine concrete is widely used. Long term strength development is distinct in concrete with blended cement and it also has excellent resistance to chloride attack and reduction of hydration heat. However, blended cement has a characteristic of relatively low compressive strength in early age of 28 days. On the other hand, a high level of compressive strength is required in the Standard Specification for marine concrete mix design. Such concrete mix design satisfying Standard Specification is effective to chloride attack but disadvantageous for hydration heat reduction due to large quantity of binder. In this study, the material properties of marine concrete considering water-binder ratio and binder type are experimentally investigated. Through the research results, compressive strength in blended cement at the age of 56 days is similar although it has smaller compressive strength at the age of 28 days compared with result of OPC (ordinary portland cement). Even though blended cement has a large water-binder ratio and small unit of binder content, chloride ion diffusion coefficient is still small and hydration heat is also found to be reduced. For meeting the required compressive strength in Standard Specification for marine concrete at 28 days, the increased unit content of binder is needed but the increased hydration heat is also expected.

A Study on the Effects of Variables in Temperature Distribution of Mass Concrete (매스 콘크리트의 온도분포에 영향을 주는 주요 변수에 관한 연구)

  • 정철헌;강석화;정한중;박칠림;오병환
    • Magazine of the Korea Concrete Institute
    • /
    • v.6 no.5
    • /
    • pp.203-212
    • /
    • 1994
  • The setting and hardening of concrete is accompanied by nonlinear temperature distribution caused by developing heat of cement hydration. This leads to tensile stresses that may exceed the strength of the young concrete, and cracks occur. In this present study, the heat of hydration characteristics are obtained from a study in which insulated concrete cubes were tested. Based on test results, concrete heat of hydration characteristics according to unit weight cement and flyash replacement quantity are determined, then employed in a numerical temperature analysis that consider both environmental interaction and concreting phases. The numerical results are performed by ADINA - T. The analytical results are in good agreement with experimental data.

The Properties of Internal Temperature of Paste and Concrete according to Component Ratio Variation of Ternary System Cement (3성분계 시멘트의 구성비 변화에 따른 페이스트 및 콘크리트의 내부온도 특성)

  • Kim, Yeon-Seung;Kim, Dong-Hyeok;Jee, Nam-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.6
    • /
    • pp.797-807
    • /
    • 2008
  • For this study, the semi-adiabatic temperature rising test is accomplished by using ternary system cement (OPC, BFS, FA) reducing temperature crack. Two tests are conducted; one is for the paste test, and the other is for the concrete test. As the results of paste tests, using fly ash is better to reduce hydration temperature than doing blast furnace slag. In the case of the paste mixed ternary system cement, the more fly ash is mixed and the less blast furnace slag is used, the lower the temperature is. The less the mixture ratio of blast furnace slag is and the more the mixture ratio of fly ash is, the later the temperature rising velocity and descending velocity are. Besides, the temperature is lower if water/binder ratio is high. The use of ternary system cement has the retardation effect of temperature rising because the time to reach the maximum temperature is in the order of OPC100, binary system cement, and ternary system cement. From the test, the maximum temperature of concrete used ternary system cement is $8{\sim}11^{\circ}C$ lower than that of concrete used OPC100. Moreover, temperatures rising velocity and descending velocity of ternary system cement range $47{\sim}51%$ and $37{\sim}42%$ compared with OPC100. The specimen of concrete shows remarkable low internal temperature and slow temperature rising velocity and descending velocity compared with the specimen of paste because it is that temperature loss of concrete is much more than paste specimen according to aggregates.

Hydration heat and autogenous shrinkage properties of silica-fume included mass concrete (실리카퓸을 사용한 매스콘크리트의 수화열과 자기수축 특성)

  • Kim, Chin-Yong;Kim, Jin-Keun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.489-492
    • /
    • 2008
  • Adiabatic temperature rise and autogenous shrinkage experiments were performed for three silica-fume included mass concrete mixtures and a reference mixture without silica-fume, in order to investigate the influence of silica-fume on the hydration heat and autogenous shrinkage properties of mass concrete, and to examine applicability of silica-fume to mass concrete. It was revealed from the experiment that, for mass concrete, the rate of hydration was hardly increased while the maximum adiabatic temperature rise decreased about 5$^{\circ}$C by the addition of silica-fume, and the amount of autogenous shrinkage was almost the same regardless of silica-fume replacement. These facts imply that silica-fume can enhance the resistance of mass concrete to temperature cracking as well as the durability.

  • PDF

Mix Design and Physical Properties of Concrete Used in Yeoju-Bo Mass Concrete ("한강살리기" 4공구 여주보 매스콘크리트의 배합설계 및 역학적 특성)

  • Ha, J.D.;Park, K.W.;Shin, D.S.;Lee, C.K.;Kim, B.L.
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.189-190
    • /
    • 2010
  • Yeoju-Bo is a large massive concrete structures that require the reduction of working period of construction. In this study, we optimized the mix proportion of internal/external concrete and physical properties like compressive strength, semi adiabatic temperature rise in laboratory. And we also performed thermal analysis to verify the thermal cracking. Lastly we measured the hydration heat and the thermal cracking in site to verify the safety of massive concrete structure.

  • PDF