Evaulation of Adiabatic Temperature Rise for Concrete with Blast-Furnace Slag replacement (고로슬래그 미분말 치환율에 따른 콘크리트의 단열온도상승 평가)

  • Kim, Joo Hyung;Lee, Do Heun;Jung, Sang Hwa
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.1
    • /
    • pp.18-24
    • /
    • 2013
  • Recently, the interest is increasing about the eco-friendly concrete. Accordingly, the blast furnace slag(BFS), a by-product of industry is known for improving the durability through compaction in concrete and is expanding the use. The research about BFS in concrete be accomplished frequently. In this study, we should know the hydration characteristic of BFS concrete the through the adiabatic temperature rise test due to the replacement of a variety of BFS. In addition, we produced the regression analysis factors through the test result and analyzied the effect for the replacement of BFS. According to test results, the compressive strength showed a slight degradation or equal and the the adiabatic temperature rise figure and rising factors are went down for rising replacment of BFS. In the future, the study about the adiabatic temperature rise equation for the various replacement of BFS and binder is considered necessary.

  • PDF

The Influence of Specimen Volume on the Adiabatic Temperature Rise of Concrete (콘크리트 단열온도 상승량에 미치는 시험체 용적의 영향)

  • Bae, Jun-Young;Cho, Sung-Hyun;Shin, Kyung-Joon;Kim, Yun-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.6
    • /
    • pp.659-666
    • /
    • 2012
  • To secure the thermal crack resistance of mass concrete, researches and the field applications of low heat portland cement (LPC), ternary blended cement (TBC) which is produced by blending ordinary portland cement with blast furnace slag and fly ash, and early strength low heat blended cement (EBC) increased in recent years. Although the model for adiabatic temperature rise is necessary for estimating the risk of thermal cracking of concrete structures, sufficient data have not been accumulated for these mixtures. In addition, the differences in adiabatic test results have been reported for the volume of test specimens. Therefore, the present study evaluated the characteristics of adiabatic temperature rise based on the type of binder and the volume of the adiabatic test specimen. Test results indicated that the maximum temperature rise ($Q_{\infty}$) and the reaction factor (r) of TBC were the lowest. Test results also showed that $Q_{\infty}$ and r changed with respect to the volume of test specimen. $Q_{\infty}$ and r obtained from 6l equipment were lower than those of 50l equipment. Therefore, corrections with respect to this phenomenon was confirmed and the corrections factors are presented.

Equipment for Measuring the Adiabatic Temperature Rise of Concrete by Compensating Heat Loss (열손실량 보정을 통한 콘크리트 단열온도상승량 예측 장치)

  • Jin, Eun-Woong;Kim, Chin-Yong;Kim, Jin-Keun
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.5
    • /
    • pp.535-542
    • /
    • 2012
  • Adiabatic temperature rise test for predicting heat of hydration in mass concrete is especially inconvenient in the field. In order to overcome the problem, the equipment to effectively and conveniently measure semi-adiabatic temperature change was developed. The main objective of this paper is to propose a new and simple equipment for measuring semi-adiabatic temperature rise by using insulation bottles. In order to predict exact heat loss of concrete using this device, it is required to assume the specific heat loss coefficient of the device by water temperature change inside the experimental device. According to experimental and analytical results, the adiabatic temperature rise does not have significant differences in changes of temperature and humidity of air, as well as initial temperature of water. By comparing adiabatic temperature rise tests, the equipment for measuring semi-adiabatic temperature change can be used to predict the hydration heat of concrete within sufficient accuracy.

An Experimental Study on the Semi-Adiabatic Temperature Rise Test of Concrete Considering Outside Temperature and Specimen Size (외기온도 및 시험체 크기를 고려한 콘크리트의 간이-단열온도 상승시험에 관한 실험적 연구)

  • On, Jeong-Kwon;Kim, Young-Sun;Moon, Hyoung-Jae;Nam, Jeong-Soo;Kim, Gyu-Yong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.6
    • /
    • pp.563-571
    • /
    • 2021
  • Recently, due to the increase in high-rise apartment and residential-commercial complex buildings, a number of mega-class mass concrete members with a thickness of 3m or more have been designed. As the construction of mass concrete such as transfer beam and slab is increasing not only in foundation members but also in special structures, research on reducing temperature cracks in mass concrete is being conducted. To review temperature cracks in mass concrete, it is important to review the thermal properties of concrete, but it is difficult to use an adiabatic temperature rise tester in the field, so the semi-adiabatic temperature rise test is mainly used. In this study, to improve the accuracy of the results of concrete heat characteristics gained by the semi-adiabatic temperature rise test, various factors affecting heat loss compensation and methods were reviewed and presented.

An Experimental Study on the Evaluation of Adiabatic Temperature Rise of Concrete (콘크리트의 단열온도 상승량의 정량화에 관한 실험적 연구)

  • 강석화;이용호;정한중;박칠림
    • Magazine of the Korea Concrete Institute
    • /
    • v.7 no.6
    • /
    • pp.186-196
    • /
    • 1995
  • In this study, parameters such as unit cement weight and placing temperature which influence on temperature rise and temperature rise velocity are investigated through adiabatic tests for the domestic ordinary portland cement(0PC). Adiabatic temperature rise suggested by Korean Concrete Spec. are compared with that from this experimental results. As a result of this study, adiabatic temperature rise of OPC suggested spec. is overestimated. Also it is shown that 2-parameter equation suggested in the spec. overestimate heat evolution at early age and reasonable prediction of heat evolution can be obtained by using 3-parameter equation. Results of numerical analysis by using the input data from this test and the suggested values from spec. shows similar temperatures. However thermal stresses pridicted using input value from spec. may result 20% more than that from this test in case of externally restricted state.

An Experimental Study on the Fundamental and Adiabatic Temperature Rise Properties of High Volume Fly Ash Concrete (HVFA 콘크리트의 기초물성 및 단열온도상승 특성에 관한 실험적 연구)

  • Kim, Sung-Su;Choi, Se-Jin;Jeong, Yong;Lim, Keun-Chang;Park, Dae-Gyun;Cho, Yun-Gu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.309-310
    • /
    • 2010
  • In this study we investigated the properties of the fundamental and adiabatic temperature rise of the concrete using high volume fly-ash. For this, the fly ash was used to replace cement at replacement ratio of 40% and 50% by mass, and then the slump, air content, bleeding, compressive strength and adiabatic temperature rise test of concrete were performed.

  • PDF

Characteristics of Adiabatic Temperature Rise for Concrete according to FA Cement and CGS Replacement Rate (FA시멘트 및 CGS 치환율에 따른 콘크리트의 단열온도상승 특성)

  • Baek, Sung-Jin;Hu, Yun-Yao;Kim, Su- Hoo;Han, Jun-Hui;Yoon, Chee Whan;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.117-118
    • /
    • 2022
  • In this study, adiabatic temperature rise of concrete depending on binder compositions and CGS contents is studied to provide informations for CGS low-heating aggregate and mixture designs for upper and lower placement lifts. Test nresults indicate that it is desirable to apply the combination of binders between top and bottom lift. For top lift, SESC or ESC is recommended, and for bottom lift, FAC+CGS 50 % is good for material composition.

  • PDF

The Properties of Internal Temperature of Paste and Concrete according to Component Ratio Variation of Ternary System Cement (3성분계 시멘트의 구성비 변화에 따른 페이스트 및 콘크리트의 내부온도 특성)

  • Kim, Yeon-Seung;Kim, Dong-Hyeok;Jee, Nam-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.6
    • /
    • pp.797-807
    • /
    • 2008
  • For this study, the semi-adiabatic temperature rising test is accomplished by using ternary system cement (OPC, BFS, FA) reducing temperature crack. Two tests are conducted; one is for the paste test, and the other is for the concrete test. As the results of paste tests, using fly ash is better to reduce hydration temperature than doing blast furnace slag. In the case of the paste mixed ternary system cement, the more fly ash is mixed and the less blast furnace slag is used, the lower the temperature is. The less the mixture ratio of blast furnace slag is and the more the mixture ratio of fly ash is, the later the temperature rising velocity and descending velocity are. Besides, the temperature is lower if water/binder ratio is high. The use of ternary system cement has the retardation effect of temperature rising because the time to reach the maximum temperature is in the order of OPC100, binary system cement, and ternary system cement. From the test, the maximum temperature of concrete used ternary system cement is $8{\sim}11^{\circ}C$ lower than that of concrete used OPC100. Moreover, temperatures rising velocity and descending velocity of ternary system cement range $47{\sim}51%$ and $37{\sim}42%$ compared with OPC100. The specimen of concrete shows remarkable low internal temperature and slow temperature rising velocity and descending velocity compared with the specimen of paste because it is that temperature loss of concrete is much more than paste specimen according to aggregates.

Hydration Heat Properties of High Flowing Self-Compacting Concrete with Normal Strength (보통강도 고유동 자기충전 콘크리트의 수화발열 특성)

  • Choi, Yun-Wang;Kim, Byoung-Kwon;Lee, Jae-Nam;Ryu, Deug-Hyun;Song, Yong-Kyu;Jung, Woo-Yong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.497-500
    • /
    • 2008
  • This research carries out experiments for hydration exothermic rate and adiabatic temperature rise of concrete to examine the characteristics of the hydration heat of high flowing self-compacting concrete with a normal strength. As a result of the hydration exothermic rate experiment, the high flowing self-compacting concrete that used Lime stone powder and fly ash as polymers shows that its hydration heat amount reduces due to the reduction of unit cement. The result measured the adiabatic temperature rise of concrete presents that high flowing self-compacting concrete having lots of binder contents has a good performance in temperature reduction due to the effect of polymer and that triple adding high flowing self-compacting concrete has a similar temperature rise speed with conventional concrete. As a result of the research, high flowing self-compacting concrete shows a better temperature reduction performance for the binder content per unit than conventional concrete. In addition, it is judged that triple adding high flowing self-compacting concrete with a specified concrete strength 30 MPa is more beneficial in temperature reduction and early hydration heat than double adding high flowing self-compacting concrete.

  • PDF

Hydration heat properties of ternary system concrete using rejct fly ash (잔사회를 활용한 3성분계 시멘트의 수화열과 콘크리트의 단열온도 특성)

  • Lee, Seung-Heun;Lee, Seung-Tae;Lee, Jae-Man;Ryu, Deun-Hyun;Kim, Do-Kyun;Seo, Chan-Won
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.331-332
    • /
    • 2009
  • The purpose of this study was to evaluate the effect of rejct fly-ash and blast-furnace slag on hydration heat and strength development of ternary system cement and concrete. Main experimental variables were performed fly-ash contenes (20%) and rejct fly-ash contents (20%) and slag contents (50%, 55%). The hydration heat and insulation temperature, strength development were measured to analyze the concrete of ternary system cement

  • PDF