• Title/Summary/Keyword: 단순 봉합술

Search Result 67, Processing Time 0.027 seconds

Arthroscopic Pull-out Suture Repair of Posterior Root Tear of the Medial Meniscus - Minimum 5 Years Follow-up Results - (내측 반월상 연골판 후방 부착부 파열의 관절경적 견인 봉합술 - 최소 5년 추시결과 -)

  • SaKong, Hyub;Shin, Hong Kwan;Lee, Young-Kook;Bae, Ki Cheor;Cho, Chul Hyun;Lee, Kyung Jae;Son, Eun-Seok;Kim, Doo Han
    • Journal of the Korean Arthroscopy Society
    • /
    • v.16 no.2
    • /
    • pp.153-159
    • /
    • 2012
  • Purpose: This study aims at evaluating our results with a 5-year follow up of arthroscopic pull-out suture repair of posterior root tear of the medial meniscus. Materials and Methods: This study enrolled 30 cases who underwent a arthroscopic pull-out suture repair to treat the posterior root tear of the medial meniscus from January 2001 to May 2005 and followed up at least 5 years. The average follow-up period was 76 months (range, 60-90 months). Clinical results by use of the Lysholm knee score and radiographic grade by use of the Kellgren-Lawrence classification were evaluated and second-look arthroscopy was done in all cases. The clinical results were compared with trauma history, obesity, varus deformity and time to operation. Results: At the last follow up, the Lysholm knee score improved from 55 points to 86 points. For the radiological results, 23 cases displayed maintenance or improvement of the medial joint space on the follow up X-ray, but 7 cases displayed decrease of the medial joint space, and 1 case was lately performed total knee replacement due to progressive osteoarthritic change. Conclusion: Arthroscopic pull-out suture repair has a good result at 27 cases (90%) in minimum 5 years follow-up. The clinical improvement was significantly reduced in more severe varus angle.

  • PDF

Arthroscopic Treatment of Symptomatic Shoulders with Minimally Displaced Greater Thberosity Fracture (상완골 대결절의 미세전위골절의 관절경적치료)

  • Kim Seung-Ho;Ha Kwon-Ick
    • Clinics in Shoulder and Elbow
    • /
    • v.2 no.2
    • /
    • pp.178-186
    • /
    • 1999
  • Twenty-three patients with chronic shoulder pain beyond 6 months after the fracture of the greater tuberosity underwent arthroscopic treatment and were retrospectively assessed after an average of 29 months(range, 22 to 40 months). There were 18 men and 5 women with the average age of 39 years(range, 24 to 61 years). Fourteen were isolated fractures and nine were related to acute anterior instability episode. The average displacement of the fracture was 2.3mm(range, 0 to 4mm) on the anteroposterior view of the plane radiographs. At the time of arthroscopy, all patients had partial thickness rotator cuff tears in the articular surface. The cuff tears were located on the tuberosity fracture area and were an Ellman's grade I to n in depth. With the arthroscopic debridement or repair of the tear depending on the condition of the tear itself, as well as the subacromial decompression, the UCLA score revealed good to excellent results in 20 and fair in 3 patients. Nineteen of the patients had returned to the previous level of activities. The patient with a higher activity demand revealed a lower level of activity return(p=0.034). The partial thickness rotator cuff tear should be considered in patients with chronic shoulder pain after the minimally displaced fracture of the greater tuberosity, and arthroscopic debridement or repair is an appropriate procedure.

  • PDF

3D analysis of soft tissue around implant after flap folding suture (Flap folding suture를 활용한 판막의 고정에 따른 임플란트 주변 연조직 3차원 부피 변화 관찰)

  • Jung, Sae-Young;Kang, Dae-Young;Shin, Hyun-Seung;Park, Jung-Chul
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.3
    • /
    • pp.130-137
    • /
    • 2021
  • Purpose: The various suture techniques can be utilized in order to maximize the keratinized tissue healing around dental implants. The aim of this study is to compare the soft tissue healing pattern between two different suture techniques after implant placement. Materials and Methods: 15 patients with 18 implants were enrolled in this study. Simple implant placement without any additional bone graft was performed. Two different suture techniques were used to tug in the mobilized flap near the healing abutment after paramarginal flap design. Digital intraoral scan was performed at baseline, post-operation, stitch out, and 3 months after operation. The scan data were aligned using multiple points such as cusp, fossa of adjacent teeth, and/or healing abutment. After subtracting scan data at baseline with other time-point results, closed space indicating volume increment of peri-implant mucosa was selected. The volume of the close space was measured in mm3. The volume between two suture techniques at three time-points was compared using nonparametric rank-based analysis. Results: Healing was uneventful in both groups. Both suture technique groups showed increased soft tissue volume immediately after surgery. The amount of volume increment significantly decreased after 3 months (P < 0.001). Flap folding suture group showed higher median of volume increment than interrupted suture group after 3 months without any statistical significance (P > 0.05). Conclusion: After paramarginal flap reflection, the raised flaps stabilized by flap folding suture showed relatively higher volume maintenance after 3-month healing period. However, further studies are warranted.

Transection of the posterior horn of the medial meniscus at the posterior tibial attachment - Clinical features and A new repair technique (Pullout suture) - (내측 반월상 연골 후각의 후방 경골 부착부위의 절단 파열 - 임상 양상 및 새로운 봉합 수기(pullout suture) -)

  • Ahn, Jin-Hwan;Ha, Chul-Won;Kim, Ho;Kim, Sung-Min
    • Journal of the Korean Arthroscopy Society
    • /
    • v.3 no.2
    • /
    • pp.109-114
    • /
    • 1999
  • Purpose : The importance of meniscal repair is well recognized. But transeciton of the posterior horn of the medial meniscus at the posterior tibial attachment is rarely documented and known irreparable. We experienced 9 cases of transection, and present clinical features and pull out suture technique. Methods and Materials : There were 9cases of transection of the posterior horn of medial meniscus from September 1998 to July 1999 in our hospital. Age was 59.3 years in average and ranged from 38 to 70years. Clinical features and MRI made diagnosis in all cases. We confirmed the diagnosis with arthroscopy and repaired the transection with pullout suture technique. Clinical features : Transection of the posterior horn of the medial meniscus at the posterior tibia attachment occurred frequently in middle aged people. They complained posterior knee pain, but they have no history of definitive trauma. Characteristically they had difficulty in full flexion of the knee and in having a squatting position. MRI is very important in diagnosis of transection, especially in coronal view, there is separation of the posterior horn of the meniscus from the posterior tibial attachment. Surgical technique : Pullout suture technique includes debridement of fibrous or scar tissue, exposure of the subchondral bone of the posterior tibial attachment site, suture the transected end of the meniscus with PDS suture, bone tunnel formation from the anteromedial aspect of the proximal tibia, insertion of wire loop through the tibia tunnel, pull the PDS suture through the tibia tunnel out of the joint and stabilize the PDS with post-tie technique to the proximal tibia. Conclusion : Transection of the posterior horn of the medial meniscus at the posterior tibial attachment is not common clinically and rarely documented. Clinical features and MRI are very important in diagnosis of this type tear. Arthroscopic pullout sutures is useful for treatment of this type tear of the meniscus.

  • PDF

Alternative Technique of Aortic Valve Replacement -Implantation of Mechanical Aortic Valve at a Supra-Annular Level- (기계판막을 판륜상연에 위치시킨 대동맥판 치환술)

  • 최종범;이삼윤
    • Journal of Chest Surgery
    • /
    • v.29 no.5
    • /
    • pp.504-509
    • /
    • 1996
  • When a valve prosthesis is to be implanted in the aortic position, simple interrupted suture, figure-of- eight suture, or horizontal mattress suture technique is used as a suture method. However, the suture techniques may be unacceptable for aortic valve replacement in patients with friable annulus caused by some lesions, such as endocarditis and degenerative change. We used an alternative technique for the aortic vlave replacement in 4 patients with valve endocarditis, ) patients with degenerative valvular lesion, and 1 with rheumatic valvular disease. Mattress sutures through the annulus were placed with pledgets on the ventricular side of the annulus, whi h resulted in implantation of the prosthesis at a supra-annular level. Mechanical valves of 21 mm or larger were implanted in the supra-annular position in all patients and there was no impeded motion of leaflets during the follow-up period of mean 13.3 mouths. The transvalvular pressure gradient was less than 6 mm Hg in 3 patients and 20 to 40 mm Hg in 5 patients. The supra-annular implantation of mechanical aortic valve using a vertical mattress suture technique may be a useful alternative method of aortic valve replacement for the selected patients with friable or destroyed aortic annulus.

  • PDF

Clinical Analysis of Patch Repair of Ventricular Septal Defect in Infant (영아기 심실중격결손 봉합술의 임상적 고찰)

  • Jung, Tae-Eun;Lee, Jang-Hoon;Lee, Dong-Hyup;Lee, Jung-Cheul;Han, Sung-Sae;Kim, Sae-Yeun;Ji, Dae-Lim
    • Journal of Yeungnam Medical Science
    • /
    • v.19 no.2
    • /
    • pp.99-106
    • /
    • 2002
  • Background: Simple ventricular septal defect(VSD) is the most common congenital heart disease. Although closure of VSD is currently associated with a relatively low risk, experience with younger and smaller infants has been variably less satisfactory. We assessed the results of surgical closure of VSD in infant. Materials and Methods: Between 1996 and 2000, 45 non-restrictive VSD patients underwent patch repair and retrospective analysis was done. Patients were divided into two groups based on weight: group I infants weighed 5kg or less(n=16), and group II infants weighed more than 5kg(n=29). Both groups had similar variation in sex, VSD location, aortic cross clamp time and total bypass time. But combined diseases (ASD, PDA, MR) were more in group I. We closed VSD with patch and used simple continuous suture method in all patients. Results: There were no operative mortality, no reoperation for hemodynamically significant residual shunt and no surgically induced complete heart block. As a complication, pneumonia(group I: 2 cases, group II: 2 cases), transient seizure(group II: 2), wound infection(group I: 1, group II: 1), urinary tract infection(group I: 1) and chylopericardium(group I: 1) developed, and there was no significant difference between two groups(p>0.05). Conclusion: Early primary closure with simple continuous suture method was applicable in all patients with non-restrictive VSD without any serious complications.

  • PDF

Follow-Up of Residual Shunt after Repair of Ventricular Septal Defect (심실중격결손 봉합 후 잔류 단락의 추적관찰)

  • 정태은;이장훈;김도형;백종현;이동협;이정철;한승세;이영환
    • Journal of Chest Surgery
    • /
    • v.35 no.8
    • /
    • pp.580-583
    • /
    • 2002
  • Background: Obtaining precise hemodynamic and morphological information in the early postoperative period after surgical correction of congenital heart disease is important in determining the need for future medical or surgical intervention. We investigated the residual shunting after surgical repair of simple ventricular septal defect in order to know the incidence of residual shunting in the postoperative period and the natural history of small residual shunts located in the peripatch area. Material and Method: Forty three consecutive patients under one year of age who underwent patch repair of a simple ventricular septal defect were evaluated for incidence of residual shunts by echocardiography. Result: Eleven patients had echocardiographic residual shunt in the peripatch area at immediate postoperative period, however, there were no patients who needed reoperation due to deteriorated hemodynamic effect of residual shunt. The incidence of residual shunts was not significantly different with type of ventricular septal defect and material used for closure. During follow up period, two patients were lost and remaining nine patients no longer showed evidence of residual shunt. The mean time of last evidence of shunt was $4.2{\pm}3.6$ months after operation. Conclusion: Residual peripatch shunt flow was frequently noted in the immediate postoperative period following surgical repair of ventricular septal defect, however, most of them were disappeared within six months.

Surgical Treatment for Common Iliac Arteriovenous Fistula after Lumbar Laminectomy (요추궁절제술 후에 발생한 총장골동맥의 동정맥루에 대한 수술)

  • Ryu, Kyoung-Min;Ryu, Jae-Wook;Park, Seong-Sik;Kim, Seok-Kon;Seo, Pil-Won
    • Journal of Chest Surgery
    • /
    • v.40 no.6 s.275
    • /
    • pp.455-458
    • /
    • 2007
  • A 40 year-old male patient admitted for dyspnea and edema of the lower extremities. A pulsatile abdominal mass with a bruit was palpable in the right lower quadrant. Four months previously, he had underwent left partial lam-inectomy ($L4{\sim}5$) and discectomy at the L4 level due to disc protrusion, Computed tomography showed an ilio-iliac AV fistula with pseudoaneurysm at the L5 level. Because massive bleeding occurred when the aneurysm was entered, we closed the aneurysm and performed resection and suture of the aorta and both iliac arteries very near the aneurysm. After exclusion of the arterial side, we performed reduction angioplasty at the aneurysm and aorto-biiliac reconstruction with an artifcial graft. Twenty-four months after operation, he is doing well and hasn't had any complications on the follow-up.

Analysis of Octyl-2-Cyanoacrylate as a Dressing Material after Pediatric Urological Procedures (소아비뇨기과 관혈적 수술 시 피부봉합제로 사용된 Octyl-2-Cyanoacrylate (Dermabond$^{TM}$)의 효용성)

  • Lee, Hahn-Ey;Min, Sun Ho;Kim, Kwang Myung
    • Childhood Kidney Diseases
    • /
    • v.16 no.2
    • /
    • pp.115-120
    • /
    • 2012
  • Purpose: We aimed to evaluate the efficacy of Octyl-2-cyanoacrylate (Dermabond$^{TM}$) as a topical skin adhesive for pediatric urologic open surgery. Methods: From August 2010 to August 2011, we retrospectively evaluated pediatric patients who underwent urologic open surgery at our institution. A total of 128 pediatric patients with 210 incisions used Dermabond$^{TM}$ for skin closure. Results: We divided the 128 patients into 3 groups according to type of surgery. Group 1 underwent hydrocelectomy (55 cases, 41.3%), Group 2 underwent orchiopexy (43 cases, 32.3%), Group 3 underwent penoplasty (35 cases, 26.4%). One hundred and twenty eight patients who underwent 133 surgeries in total, with a total of 210 incisions visited our outpatient department postoperatively, and a total of 5 wound complications (2.3%) occurred, but were simple inflammations and no dehiscence was observed. When analyzed according to groups, no wound problems occurred in Group 1 (0/55, 0%), one occurred in Group 2 (1/43, 2.3%) and four cases occurred in Group 3 (4/35, 11.4%) respectively. When re-analyzed according to wound locations, one occurred in an inguinal wound (1/120, 0.83%), none occurred in scrotal wounds (0/55, 0%), and four occurred in penile wounds (4/35, 11.4%). In Group 3, the incidence of penile wounds was significantly increased compared to other groups (P=0.008). All 5 wound problems were inflammatory and healed at an average of 13.8 days (13-15 days) with antibiotic ointment application only. Conclusion: Dermabond$^{TM}$ is feasible and safe topical skin adhesive alternative to standard skin suture in pediatric urologic surgery. However, further research about its efficacy and safety could be valuable in the future.

Covered Self-expandable Metallic Stent Insertion as a Rescue Procedure for Postoperative Leakage after Primary Repair of Perforated Duodenal Ulcer (십이지장 궤양 천공 단순 봉합수술 후 완전 피막형 자가확장 금속 스텐트 삽입술로 치료된 봉합 부위 누출)

  • Yoo, Young Jin;Lee, Yong Kang;Lee, Joong Ho;Lee, Hyung Soon
    • The Korean Journal of Gastroenterology
    • /
    • v.72 no.5
    • /
    • pp.262-266
    • /
    • 2018
  • Surgery has been the standard treatment for perforated duodenal ulcers, with mostly good results. However, the resolution of postoperative leakage after primary repair of perforated duodenal ulcer remains challenging. There are several choices for re-operation required in persistent leakage from perforated duodenal ulcers. However, many of these choices are complicated surgical procedures requiring prolonged general anesthesia that may increase the chances of morbidity and mortality. Several recent reports have demonstrated postoperative leakage after primary repair of a perforated duodenal ulcer treated with endoscopic insertion using a covered self-expandable metallic stent, with good clinical results. We report a case with postoperative leakage after primary repair of a perforated duodenal ulcer treated using a covered self-expandable metallic stent.