• Title/Summary/Keyword: 단순보실험

Search Result 556, Processing Time 0.022 seconds

An Experimental Study on the Structural Performance of Openings at End Steel Beams (강재 단순보 단부에 근접한 개구부의 구조성능에 관한 실험적 연구)

  • Han, Dong-Ho;Yoon, Sung-Kee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.6
    • /
    • pp.138-145
    • /
    • 2020
  • This study was conducted to identify the structural performance of the opening in a location close to the support point in the perforated beam system of steel beams. In addition, structural performance was determined through experiments on reinforced openings using vertical and horizontal steel plates. In the steel simple beam, it was found that the opening was in a position closer to the support point, half the height of the steel beam (D/2), which was more appropriate than the height of the steel beam (D). In addition, the reinforcement effect of horizontal steel plate was greater than that of vertical steel plate reinforcement. Structural performance was improved when there was no gap between openings and steel plates.

An Experimental study on the Bolted Moment Connection between H-Beam and CFT Column (CFT기둥과 H-형강보의 볼트 접합부에 관한 실험적 연구)

  • Park, Soon Kyu;Roh, Hawn Kewn
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.4 s.37
    • /
    • pp.789-799
    • /
    • 1998
  • The purpose of this study is to propose the prototypes of bolted end plate moment connection between CFT column and H-beam sections. Nine different types of bolt are designed in this study. The shapes of those bolt are straight. bent, hooked or stud-type. The end plate moment connection between CFT column and H-beam sections which are jointed by those bolts are studied experimentally to compare their performances. The simple beam bending tests are carried out to investigate the structural behavior of beam-to-column connections. The experimental results show that some of the bolted end plate connection types have quite good performance in the structural behavior but still have a lot of week points to be solved for the efficiency of construction.

  • PDF

An Experimental Study on the Flexural Stiffness and Plastic Hinge Ratation Capacity of Reinforced High Performance Concrete Beams (고성능 철근콘크리트 보의 휨강성 및 소성힌지의 회전능력에 관한 실험적 연구)

  • 고만영;김상우;김용부
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.4
    • /
    • pp.93-100
    • /
    • 1998
  • This paper presents a study on the flexural stiffness, plastic hinge length and plastic hinge rotation capacity of reinforced high performance concrete beams. 15 beams with different strength of concrete, reinforcement ratio and the pattern of loadings were tested. From the test results of reinforced normal strength concrete beams and reinforced high performance concrete beams with the concrete which has cylinder compressive strength of 700kg/${cm}^2$, slump value of 20~25cm and slump-flow value of 60~70cm. It is found that an extreme fiber concrete compressive strain of ${\varepsilon}_{cu}=0.0047$ may be used in ultimate curvature computations of reinforced high performance concrete beams. An empirical equation is proposed to estimate the effective moment of inertia. length and rotation capacity of plastic hinge of simply supported reinforced high performance concrete beams. The estimated deflections using this equation agree well with the experimental values.

Experimental Evaluation on Effective Moment of Inertia of Reinforced Concrete Simple Beams and Continuos Beams Considering Tension Stiffening Effect (인장증강효과를 고려한 철근콘크리트 단순보와 연속보의 유효 단면2차모멘트에 대한 실험적 검증)

  • Lee, Seung-Bae;Yoon, Hyeong-Jae;Kim, Kang-Su;Kim, Sang-Sik
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.285-288
    • /
    • 2008
  • A model for the effective moment of inertia $I_{\epsilon}$ as expressed in Branson's equation, in which reduction of the flexural rigidity of RC beams due to cracking are aptly taken into accoun,t is presented. However, KCI Code isn`t considered tension stiffening as it is in debonding of reinforcing bar. Therefore, this equation need to set up suitable to our design Code. The experimental work consisted of casting and testing a total of 6 simply supported reinforced concrete beams and a total of 4 continuos reinforced concrete beams under two point concentrated loads. Main parameters are concrete strength, coverage, bond between concrete and reinforcing bars, are known as have an effect on deflection and tension stiffening. Every test beams had the same $250{\times}350$mm rectangular section, with a simply supported clear span of 4,400 mm and a continuos clear span of 6,500 mm. Comparison of the test results with values obtained using the KCI Code equation of the effective moment of inertia showed a noticeable difference.

  • PDF

Control of Bending Behavior of Simple Beams Using CTMD (CTMD의 질량비에 따른 단순보의 휨거동 제어효과)

  • Heo, Gwang-Hee;Seo, Sang-Gu;Kim, Chung-Gil;Jeon, Seung-Gon;Kim, Min-Ki
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.12-18
    • /
    • 2021
  • The purpose of this study is to effectively mitigate the bending displacement that occurs in the bridge due to forced vibration. We developed CTMD (Combine Tuned Mass Damper) that combines the relationship between spring and mass to control the bending behavior of simple beams. The experiment was conducted to confirm the control effect according to the change in the mass ratio of the developed CTMD. The developed CTMD is designed and manufactured so that the mass ratio can be adjusted according to the characteristics of the bridge. The maximum load of the spring applied to CTMD was fixed at 33.15 N. In order to evaluate the performance of the developed CTMD, a simple beam composed of hinges and rollers as boundary conditions was fabricated. In the experimental method, a CTMD was installed in the center of a simple beam and the deflection displacement according to the mass ratio was measured. The shaking condition was shaken at 3 Hz to induce the maximum bending behavior of the simple beam. As a result of the experiment, it was confirmed that when the optimal mass ratio was 2.1, the damping rate of the bending behavior displacement was about 71.2 %, indicating the best control effect.

Nonlinear Analysis of Reinforced Concrete Simple Beam Subjected by Bending Moment (휨을 받는 철근콘크리트 단순보의 비선형 해석)

  • Han, Jae-Ik;Lee, Kyeong-Dong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.2
    • /
    • pp.129-136
    • /
    • 2001
  • 본 연구의 목적은 휨을 받는 철근콘크리트 단순보의 비선형 거동을 해석을 통하여 파악하기 위하여 보의 단면을 Layer로 분할하여 각 Layer에 사용된 재료의 특성을 부여하고, 작용하중에 의한 비선형 특성을 응력-변형도 모델을 통하여 반영할 수 있도록 알고리즘을 작성하는 것이다. 본 연구에서 제안한 알고리즘을 사용하면 실험을 위한 보(beam)를 제작하지 않고도 사용재료의 압축 및 인장 실험을 위한 몰드 만을 제작하여 재료에 대한 정확한 응력-변형도 모델을 작성함으로써 합성보의 거동을 수치해석을 통하여 간단하게 파악할 수 있을 것으로 기대된다.

  • PDF

Elasto-Plastic Behavior of Steel Beams with High Strength Bolted Splices (고력볼트 접합이음 철골보의 탄소성거동)

  • Choi, Sung Mo;Kim, Jin Ho;Roh, Won Kyoung
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.5 s.66
    • /
    • pp.531-539
    • /
    • 2003
  • Unlike field-welded moment frames damaged during the Northridge earthquake, a column-tree moment frame has a tool to control and reduce its seismic behavior. The tool is the girder splice. Girder splices could be designed to be sufficiently ductile and to have a prescribed bending moment capacity. In such a design, during earthquakes, the girder splices would act as ductile "fuses" and limit the magnitude of forces including the bending moment that could be developed in the frame. In Korea, most moment frames arc composed of a column-tree moment frame. Therefore, the elasto-plastic behavior of steel beams with high strength bolted friction splice should be clarified. Furthermore, structural capacities, including energy absorption capacity, must be quantitatively found. This paper discusses an experimental study to clarify elasto-plastic behavior of steel beams with high strength bolted friction splices. A total of 5 specimens were tested. A specimen was fabricated to have a beam splice designed by a full strength method. Other specimens were fabricated to have beam splices with 75%, 50% and 0% capacities compared with the specimen.

Strength and Deformation of Exterior HSC column-Steel beam Joints (고강도 콘크리트 기둥-강재 보 외부 접합부의 강도 및 변형)

  • 조순호;선성규
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.4 no.3
    • /
    • pp.35-44
    • /
    • 2000
  • 전편의 실험적 연구에 이어서, 기 수행된 4개의 외부 접합부 시험체에 현존하는 여러 강도 예측식을 사용하여 콘크리트 기둥-강재 보 접합부의 내진 성능을 결정하는 패널 전단 및 지압 강도를 평가하였다. 또한, 접합부 패널지역의 변형특성을 묘사할 수 있는 일련의 스프링을 사용한 macro 형태의 해석모델이 논의되었으며, 이에 따라 Drain-2DX 및 IDARC 등의 상용프로그램을 사용하여 접합부의 패널전단 및 지압 파괴형태의 변형을 포함하는 단순해석이 수행되었다. 강도 예측결과에 의하면 본 연구에서 제시하는 수정된 내부 콘크리트 패널 전단 강도식을 포함하고 있는 ASCE 방법이 실험결과에 가장 근접한 것으로 나타났으며, 본 연구에서 검토된 패널지역 변형을 고려한 단순해석모델은 향후 전체 건물해석에 사용할수 있는 것으로 판단되었다.

  • PDF

An Analytical Study on the Flexural Behavior of RC Beams Strengthened with High Tension Bars (고장력 인장봉으로 보강된 RC보의 휨거동에 관한 해석적 연구)

  • Shin, Kyung Jae;Kim, Byung Jun
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.3
    • /
    • pp.259-270
    • /
    • 2007
  • This paper presents an analytical method of evaluating the flexural behavior of RC (reinforced concrete) beams strengthened with high-strengh bars. The former experimental results were used to compare with the analytical results. The experimental results also outline the advantages of externally strengtheng method with high-strenght bars. To evaluate the flexural behavior of RC beams strenghtend with unbonded high-strength bars, this paper proposes a method involving a simple strength-summation method. This method basically assumes that the total strength of RC beams strengthened with high-strength bars is equal to the sum of the strengths of the RC beams and the high-strength bars. This analytical method also includes the effects of compressive force due to the tension from high-strength bars. A comparison of the analytical and experimental results leads to the conclusion that the simple strength-summation mothod can simulate the flexural behavior of RC beams strengthened with high-strength bars with a good level of accuracy.

Load Distribution Ratios of Indeterminate Strut-Tie Models for Simply Supported RC Deep Beams - (II) Validity Evaluation (단순지지 RC 깊은 보 부정정 스트럿-타이 모델의 하중분배율 - (II) 적합성 평가)

  • Kim, Byung Hun;Jeung, Chan Haek;Yun, Young Mook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.2A
    • /
    • pp.269-279
    • /
    • 2008
  • In this study, the ultimate strengths of 229 simply supported reinforced concrete deep beams tested to shear failure were evaluated by the ACI 318-05's strut-tie model approach implemented with the presented indeterminate strut-tie model and its load distribution ratio. The ultimate strengths of the deep beams were also estimated by the experimental shear equations, design codes that were based on experimental and theoretical shear strength models, and current strut-tie model design codes. The validity of the present strut-tie model and its load distribution ratio was examined through the comparison of the strength analysis results classified according to the prime design variables of the shear span-to-effective depth ratio, flexural reinforcement ratio, and compressive strength of concrete.