Acknowledgement
이 논문은 2018년도 정부(교육과학기술부)의 재원으로 한국연구재단의 지원을 받아 수행된 연구사업(NRF-2018R1A6A1A03025542, NRF-2018R1D1A1B07050590)임. 본 연구가 이루어지도록 지원하여 준 한국연구재단에 대단히감사합니다.
References
- Housner, G. W., Bergman, L. A., Caughey, T. K., Chassiakos, A. G., Claus, R. O., Masri, S. F., Skelton, R. E., Soong, T. T., Spencer, B. H., and Yao, T. P. (1997), Structural control : Past, Present, and Future, Journal of Engineering Mechanics, ASCE, 123(9), 897-971 https://doi.org/10.1061/(ASCE)0733-9399(1997)123:9(897)
- Lim Q., Fan, J., Nie, J., Li, Q. and Chen, Y. (2010), Crowd-induced random vibration of footbridge and vibration control using multiple tuned mass dampers, Journal of Sound and Vibration, 329(19), 4068-4092. https://doi.org/10.1016/j.jsv.2010.04.013
- Banerji, P., Samanta, A. (2011), Earthquake vibration control of structures using hybrid mass liquid damper, Engineering Structures, 33(4), 1291-1301. https://doi.org/10.1016/j.engstruct.2011.01.006
- Kwon, Y. R., Choi, K. K. (2003), Study on the Vibration Control of Footbridge by Using Tuned Mass Damper(TMD), Journal of the Earthquake Engineering Society of Korea, 7(6), 9-15. https://doi.org/10.5000/EESK.2003.7.6.009
- Robert, J., McNamara. (1977) Tuned Mass Dampers for Buildings, Journal of Structural Division, ASCE., 103(9), 1785-1798. https://doi.org/10.1061/JSDEAG.0004721
- Kang, J. W., Kim, G. C., Kim, H. S. (2010), Seismic Control of Arch Structures using Semi-active TMD, Journal of the Korean Association for Spatial Structures, 10(1), 103-110.
- Kwon, H. C., Kim, M. C., Lee, J. H., Lee, I. W. (1996), Vibration Control of Bridges under Moving Loads, 16(1-3), 271-281.
- Debnath, N., Deb, S. K., Dutta, A. (2016), Multi-modal vibration control of truss bridges with tuned mass dampers under general loading, Journal of Vibration and Control, 22(20), 4121-4140. https://doi.org/10.1177/1077546315571172
- Min, K. W., Lee, Y. U. (1995), Free Vibration of Torsionally-coupled Buildings with Tuned Mass Dampers, Journal of the Architectural Instutute of Korea, 11(12), 245-251.
- Den Hartog, J. P. (1956), Mechanical Vibrations, McGraw-Hill, New York.
- Kim, H. J., Choi, S. Y., Jo, S. W., Hwang, J. S., Yu, E. J. (2011), Wind Response Monitoring of a Building with TMD, Journal of the Architectural Institute of Korea Structure&Construction, 27(12), 83-90.
- Park, K. S., Koh, H. M., Park, W. S., Ok, S. Y. (2002), Optimal Design of Multiple Tuned Mass Damper Considering Model Uncertainly of Structural System, Journal of Korean Society of Civil Engineers, 22(3A), 533-543.
- Abe. .M., Fujino, Y. (1994), Dynamic characterization of multiple tuned mass dampers and some design formulas, Earthquake Engineering and Structural Dynamics, 23(8), 813-835. https://doi.org/10.1002/eqe.4290230802
- Kareem, A., andvKline, S. (1995), Performance of Multiple Mass Dampers under Random Loading", Journal of Structural Engineering, 121(2), 349-361.
- Hayashikawa, T., Watanabe, N. (1981), Dynamic Behavior of Continuous Beams with Moving Loads, Journal of Engineering Mechanics Division, 107(1), 229-246. https://doi.org/10.1061/JMCEA3.0002694
- Gu, M., Chen, S. R. (2001), Chang CC. Parametric study on multiple tuend mass dampers for buffeting control of Yangpu Bridge, Journal of Wind Engineering and Industrial Aerodynamics, 89(11-12), 987-1000. https://doi.org/10.1016/S0167-6105(01)00094-0
- Nishitani, A., Inoue, Y. (2001), Overview of application of active/semiactive control to building structures in japan, Earthquake Engineering and Structural Dynamics, 30(11), 1565-1574. https://doi.org/10.1002/eqe.81