• Title/Summary/Keyword: 단면 검사

Search Result 210, Processing Time 0.026 seconds

Evaluation of usefulness of multi directional angles oblique scan method in optic nerve MRI (시각신경 MR 검사 시 다중 각도 스캔 기법의 유용성 평가)

  • Cho, Moo-Seong;Cho, Jae-Hwan;Bae, Jae-Yeong;Kim, Jeong-Soo;Kim, Kyeong-Keun
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.4
    • /
    • pp.161-169
    • /
    • 2011
  • This research experimented on the change of the multiple colleague scan angle facing one scan object facet to many directions of the form of 3D about the visual angle nervous system forming the cubic distribution with the gradient magnetic field of the mri system and considered the existing basic angle oblique direction test coverage and comparison. MR system can freely select various pulse sequence and image slice. To oblique imaging for optic nerve viewing, we have studied the variation of scan angle between typical oblique scan method (sagittal-coronal plane) and multi directional angles oblique scan method (sagittal-coronal-axial plane) using gradient of MR system. In this study, the subjects of the experiment were normal adults in our country. As a result, we confirmed that multi directional angles oblique scan method can display anatomical information of more wider area than typical oblique scan method. In addition, to clearly display optic nerve, we also confirmed that image slice thickness and pulse sequence have effect on it.

Analysis of the Correlation Between Kidney Function Indicators and Kidney Size According Age Groups in Ultrasonography (신장 초음파 검사에서 연령대에 따른 신장 기능 지표와 신장 크기 간의 상관관계 분석)

  • Go, Ryo-won;Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.871-879
    • /
    • 2020
  • The purpose of this study was to analysis the correlation between kidneys function indicators and these size in ultrasonography. A total of 170 (male:86, female:84) patients of sex and age groups were examined by abdominal ultrasonography. The patients classified as those in their 20's, 30's, 40's, and over 50's. We measured the length, width, and cross-sectional height of the kidneys twice. At this time, the length of these were measured from the maximum upper to the maximum lower pole and the widest width in the same ultrasonography was measured to obtain the cross-sectional area. Other relevant indicators included body surface area, serum creatinine, glomerular filtration rate (GFR), MDRD (Modification of diet in renal disease) and C-G (Cockcroft-Gault). Significant comparisons of differences between relevant factors by age groups and sex were conducted with a one-way distribution analysis. Correlation analysis was also performed between relevant factors by using Pearson and Spearman correlation coefficient. It was defined as meaningful when the p-value was less than 0.05. As a result, the length, the width, and the cross-sectional area of kidneys were correlated with GFR, C-G, MDRD. Therefore, it is expected that the accuracy of diagnosis of kidneys disease will be increased if the relevant indicators are evaluated together rather than measuring only length of these in ultrasonography.

Development and Application of Photoacoustic Microscope using Accelerometer (가속도센서를 이용한 광음향현미경의 제작과 응용)

  • Kim, D.H.;Kwon, Oh-Yang
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.4
    • /
    • pp.219-227
    • /
    • 1995
  • A two-dimensional photoacoustic microscope utilizing photoacoustic signals generated by periodic heating of specimen surface with Argon ion laser and measured by accelerometer has been developed. Several aluminum specimens with various defects have been examined, characteristics of the microscope have been evaluated and optimal experimental conditions have been determined by examining the dependence on several experimental conditions including the modulation frequency and the beam width of laser.

  • PDF

Structural and Textural Characteristics of Egg Custard with Soused Shrimp Juice (새우젓국물 첨가에 따른 알찜의 구조 및 질감에 관한 연구)

  • 배영희
    • Korean journal of food and cookery science
    • /
    • v.9 no.4
    • /
    • pp.303-307
    • /
    • 1993
  • Structural and textural characteristics of egg custard with 1.5ft sodium chloride as salt or soused shrimp juice were investigated by SEM, texturometer and sensory evaluation.: 1. Egg custard without sodium chloride showed flat, crosslinkaged structure and no pores. : but the addition of salt or soused shrimp juice developed much of round pores and smooth walls. 2. There were significant difference in hardness between without sodium chloride group and boiled soused shrimp juice group. 3. there were significant difference in appearance, taste and texture, but flavor and total acceptability did not showed significant difference in preference test. In discriminating test, swellness, softness, flavor, color, holes and hardness were important factors affecting the preference to determine the characteristics of egg custard.

  • PDF

Comparative Study on Usefulness of SPAIR and STIR Fast SE T2-weighted 3T Magnetic Resonance Imaging (3T 고속스핀에코 T2강조영상에서 지방소거 반전회복기법의 유용성 연구 - SPAIR와 STIR와의 비교 -)

  • Lee, Hoo-Min;Yoon, Joon;Yeo, Young-Bok
    • Journal of radiological science and technology
    • /
    • v.33 no.1
    • /
    • pp.45-50
    • /
    • 2010
  • In this study, we compared the clinical usefulness of SPAIR (Spectral Adiabatic Inversion Recovery) and STIR (Short TI Inversion Recovery) to evaluate the fat tissues precisely. The images of brain axial (n = 20), lumber spine sagittal (n = 20), hip joint coronal (n = 17) and knee joint (n = 25) were obtained by turbo spin echo T2 weighted method on 3T magnetic resonance image. The signal intensity (SI) values were measured using region of interest in fat, muscle tissue, and background noise. The inhomogeneity values were measured using the standard deviation (SD) value divided by the mean values. SD signifies the amount of error which is similar to the imaging heterogeneity. In brain axial images, the SPAIR showed more superior SI and inhomogeneity results than the STIR. In spine, hip and knee images, STIR showed more excellent SI results, but poor inhomogeneity than the SPAIR.

Simulation of the Coating Thickness Measurement in the TRISO-coated Fuel Particle Image Reconstruction by the Filtered Backprojection (Filtered Backprojection에 의해 복원된 TRISO 핵연료입자 단층 영상을 이용한 코팅 두께 측정 시뮬레이션)

  • Kim, Woong-Ki;Lee, Young-Woo;Park, Ji-Yeon;Ra, Sung-Woong
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2005.11a
    • /
    • pp.713-716
    • /
    • 2005
  • 차세대 원자로로 부각되고 있는 고온가스냉각 원자로에서는 고온 안정성 및 핵분열생성물 차단 성능이 우수한 TRISO(Tri-Isotropic) 핵연료를 사용하고 있다. TRISO 핵연료 입자는 직경이 약 1mm인 구 형태로 입자의 중심에는 직경 $0.35^{\sim}0.6\;{\mu}m$의 핵연료 입자가 포함되며 입자 외곽을 코팅 층이 에워 싸고 있다. 이 코팅층은 완충(buffer) PyC 층, 내부 PyC 층, 외부 PyC 층으로 구성되어 있다. 각 코팅 층의 두께를 수십$^{\sim}$${\mu}m$ 범위이며 사양으로 정해져 있어 핵연료 입자 제조 후 사양을 만족하는지를 검사해야 한다. 본 연구에서는 TRISO 핵연료 입자 정보를 컴퓨터로 생성하고 가상의 X-선 래디오그래피 방법을 이용하여 투시 영상을 구성한 후 Filtered Backprojection 기법을 이용하여 단면 영상을 재구성하고 이 단면 영상을 이용하여 코팅 층의 두께를 정밀하게 측정하기 위한 모의 실험을 수행하였다. 경계선이 불명확한 투시영상이 아닌 경계선이 명확한 재구성 단면 영상을 이용하여 코팅 층의 두께를 약 2.3% 이내의 오차율로 정밀하게 측정하였다.

  • PDF

Objective in Vivo Quantification of Emphysema by Thin-Section CT: Correlation with Physiologic Findings (고해상 전산화단층촬영을 이용한 폐기종의 정량적 분석: 폐기능 검사와의 비교)

  • Lee, Jee-Young;Lee, Kye-Young;Choi, Eun-Kyoung;Kim, Sang-Joon;Choi, Young-Hi
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.5
    • /
    • pp.992-999
    • /
    • 1998
  • Background: To correlate the emphysema score for quantification of the overall extent of emphysema in both lungs by CT with physiologic fingings and to get more objective and simple method to assess the extent of emphysema. Method: Thin-section CT and pulmonary function test(PFT) were performed in 17 patients with emphysema (all males, mean age, 62 years). Emphysema score was obtained as percentage of emphysematous lung area, dividing the total area of the emphysema(voxels with attenuation value less than -880, -900, -920HU, respectively) by the overall area of both lungs(voxels with attenuation value less than -400HU) with highlighting voxels using "Density mask" program. Emphysema score was calculated from whole lung(ESV) and 5 representative scans(ESR) using "Density mask", Visual emphysema score(ESV) was obtained by visual assessment from 5 representative scans. Correlation of these emphysema scores(ESW, ESR, ESV) and physiologic findings were performed, comparing the ESW with ESR and ESV. Results: ESW had correlation with DLCO(r=0.53-0.64) and $FEV_1/FVC$(r=0.42-0.57) among PFT parameters. ESR had good correlation with ESW and with PFT parameters as well. ESV did not correlate with PFT parameters except DLCO. Conclusion: CT quantification of emphysema using "density mask" correlated well with physiologic findings. To assess the severity of emphysema, both ESW and ESR are more reliable than ESV, and ESR is recommended in routine practice as it is objective, simple and reliable.

  • PDF

Impedance Analysis and Experimental Study of a Solenoid Eddy Current Sensor to Detect the Cross-sectional Area of Non-ferromagnetic Stranded Conductors (비자성 연선도체의 단면적을 검출하기 위한 솔레노이드 와전류 센서의 임피던스 해석 및 실험적 연구)

  • Kim, S.D.;Shim, J.M.
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.2
    • /
    • pp.87-94
    • /
    • 1997
  • Impedance analysis of a Solenoid sensor to detect the cross-sectional area of non-ferromagnetic stranded conductors is described in this paper. To inspect electromagnetic characteristics of conductive materials, a nondestructive test eddy current sensor with an encircling coil is chosen. As solving Maxwell equation, normalized impedance response of the sensor within a conducting rod is modeled and the results are expanded to the stranded wires. Geometrical property affecting on stranded structure is considered and a numerical and experimental study is also presented.

  • PDF

Effect on detecting signal according to transition of pipeline thickness in Magnetic Flux Leakage system (자기누설탐상시스템에서 배관의 두께 변화가 탐상신호에 미치는 영향)

  • Seo, Kang;Park, Gwan-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.643-644
    • /
    • 2006
  • 자기누설탐상시스템은 지하에 매설된 가스관에서 발생되는 부식이나 크랙 또는 기계적 변형을 탐지하기 위한 방법으로 비파괴검사 방법의 하나이다. 가스관은 Nd자석에 의해 착자가 되고, 가스관에 부식이 발생했을 경우 가스관의 단면적이 작아지게 되어 자기누설이 발생하며, 발생된 자기누설을 홀센서로 검출하여 부식의 유무, 크기, 모양 등을 판별하게 된다. 지하매설 배관은 배관의 직경은 같으나 배관의 두께는 다양하게 존재한다. 특히 30inch의 배관에는 배관의 두께가 11.1, 14.3, 17.5 mm 등이 있다. 자기누설탐상시스템은 배관의 단면적 변화를 감지하는 것이기 때문에 배관의 두께에 따라 그 특성이 변화하게 된다. 또한 두께에 따른 결함의 종류에 따라서 검출신호도 변화하게 된다. 따라서 본 논문에서는 배관의 두께 변화에 따른 검출신호를 분석하였으며, 두께 변화의 영향을 적용하여 검출신호를 보정하기 위한 방법을 제시하였다.

  • PDF

Z-Score를 이용한 관류영상과 조영전후 감산에 의한 역동영상의 뇌관류 양상의 비교 관찰

  • 최순섭;오종영;남경진;이영일
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.171-171
    • /
    • 2001
  • 목적: 뇌 자기공명영상에서 Z-score를 이용한 관류 영상과 조영전후의 감산에 의한 역동 영상의 관류 양상을 비교 관찰 하고자 한다. 대상 및 방법: 뇌 자기공명영상에서 이상 소견이 없는 젊은 환자 1명, Moya moya 환자 1, 중대뇌동맥 폐색 환자 1명, 외상후 증후군 1명, 뇌종양 1예를 대상으로 하여, 뇌의 routine 자기공명 영상과 함께 Gd-DTPA 0.1 mmol/kg를 급속 주사 후 자화율 대조 EPI 영상을 얻었다. 영상 기기는 Magnetom Vision(Siemens Medical Systems, Erlangen, Germany)이며, EPI 영상 지표들은 TR/TE는 0.8/29 msec, slice 두께 6 mm, slice 수 10, 화소수 128 $\times$ 128, FOV 215 $\times$ 215 mm, 영상획득 1 회, 1회 검사시간 1.32 초, 검사수 30 회로서, 총 검사시간은 40 초였다. 검사 후 영상처리(post processing)는 Magnetom Vision의 VB31D 자체 프로그램을 이용하였는데, 2-score를 이용한 관류영상은 조영제 유입전 영상들, 조영제 최대 유입기 영상들, 그리고 조영제 배출기 영상들 4-5 회를 각각 한 군으로 하여, Z-score 1.2에서 2.0 사이에서 여러번 반복하여 영상을 재구성하였다. 감산에 의한 역동영상은 조영제 도달 전의 영상으로부터 조영제 유입 후의 영상을 차례로 빼어서 영상을 재구성하였으며, 이들 영상을 재정리하여 각 단면의 시간 경과에 따른 관류 양상을 연속하여 관찰하였다 두 방법에 의한 영상 재구성은 각각 약 10분 정도가 소요되었다.

  • PDF