• Title/Summary/Keyword: 단로기

Search Result 25, Processing Time 0.027 seconds

Development of Evaluating Technology for the Capability of Carrying Short-Circuit Current at Electrical Contacts in EHV Disconnecting Switches (초고압 단로기 접점의 단락전류 통전성능 평가기술 개발)

  • Oh, Yeon-Ho;Song, Ki-Dong;Chong, Jin-Kyo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.1
    • /
    • pp.46-51
    • /
    • 2008
  • Extra-high voltage(EHV) disconnecting switch(DS) consists of the electrical contacts and mechanical parts which actuate the contacts. When the short-circuit condition occurs, a large amount of current flows through the electrical contact in disconnecting switches and this causes considerable temperature rise due to Joule heating. If the temperature rise is higher than the melting point of contact material, the DS contact becomes melting and cannot be usable anymore. For this reason, the analysis for capability of carrying short-circuit current in DS contacts must be performed at a design stage. Here, we proposed a numerical technique for evaluating the capability of carrying short-circuit current at electrical contacts in EHV DS. In this numerical approach, the mechanical and thermal analyses were simulated to check the capability of carrying short-circuit current. First, the applied pressure at contact parts was analyzed considering the mechanical properties, and then contact resistance was calculated by an empirical equation. Finally, thermal analysis was performed with resistance variation at electrical contacts. To verify these numerical results, the distributions of temperature in DS were experimentally measured and compared with each other. The results from experiments were agreed well with those from the proposed numerical simulations.

Experimental Study on Temporary Overvoltage Characteristics of MOV Based Surge Protective Devices (MOV 기반 서지보호기의 일시과전압 특성에 대한 실험적 연구)

  • Shim, Hae-Sup;Jeon, Tae-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.71-77
    • /
    • 2010
  • Protection against lightning surge is an essential part of almost any electrical and electronic equipment today. Metal Oxide Varistor(MOV) is the single most important component in the overwhelming majority of the Surge Protective Devices(SPD) designated to provide such protection. In this paperr various types of MOV based SPD are inspected and experiments are carried out on the side effects of the low Measured Limiting Voltage(MLV) characteristics. Experiment results show that a lower MLV could cause a higher Temporary Overvoltage(TOV)-induced SPD failure rate in the field, and SPD are more likely to be victims rather than protectors in a TOV scenario. This means that from a safety perspective, the SPD should be specified with higher TOV withstand capability(UT) and faster SPD disconnector.

Fatten Analysis of Trouble Signal on DS for GIS using Neural Network (신경회로망을 이용한 GIS용 단로기의 이상신호 패턴분석)

  • 김종서;이은석;천종철
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.12S
    • /
    • pp.1310-1315
    • /
    • 2003
  • GIS(Gas Insulated Switchgear) is power equipment with excellent dielectric strength and is economy merit in high confidence and stability. But, because of structural characteristics, this is difficult to monitor externally and provide much loss in the event of an accident. Recently, because equipment of GIS is occurring problem of confidence used for a long time, development of diagnosis technique have been importantly recognized. therefore, measurement and analysis of PD much has been generally used for equipment of GIS. But, in case of measurement of PD at field, real trouble signals is difficult to classify noise. Accordingly, a variety of trouble conditions for DS are simulated, and detected signals are analyzed by the application of electrical and mechanical methods. For this analysis, detected signals are accumulated according to phase-magnitude with the application of induction sensor, and then we analyzed the characteristics. For the simulation experiment, we make DS for 170KV GIS and analyze the characteristics of detected signals with the application of neural network algorithm. last, we have measured DS for GIS at field, and then have analyzed detected signals.

Fault Diagnosis Technology of Power Supply Insulation System in Metro Substation (도시철도 절연기기의 진단데이터 획득 기술)

  • Park, Young;Jung, Ho-Sung;Kim, Hyung-Chul;Oh, Seok-Yong;Song, Joon-Tae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.266-266
    • /
    • 2009
  • This paper describes important parameters used to evaluate the insulation performance of power supply components in metro substations. For online fault diagnosis of power supply components, we have developed a new remote condition monitoring system using wireless technology. Our developed system can continuously monitor electric power equipment such as transformers, circuit brakers, and rectifiers and have powerful wireless networking functions.

  • PDF

Trends in standards of low voltage circuit breaker and activities of IEC SC17B, SC17D (저압차단기 규격동향 및 IEC SC17B, SC17D 활동에 관한 고찰)

  • Lee, Dong-Jun;Roh, Chang-Il;Jung, Heung-Soo;Kim, Sun-Koo;Kim, Won-Man;Kim, Sun-Ho;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.951-952
    • /
    • 2007
  • International Electrotechnical Commission (IEC)은 국제 규격을 제 개정하는 단체로서, 1906년에 설립된 조직이다. 2006년 말 기준으로 67개국의 회원 국가를 보유하고 있으며 총 5,613개의 규격을 제 개정하고 있다. IEC는 많은 수의 규격을 제 개정하기 위하여 100개의 Technical Committee (TC)와, 각 TC 산하에 Subcommittees(SC)를 두고 있다. SC는 다시 산하에 Working group(WG)을 두어 실제적으로 해당 국제규격의 제 개정은 바로 이 WG에서 작업을 하게 된다. 본 논문에서는 IEC TC17내의 SC17B와 SC17D의 구성, 현황 및 활동과 현재 진행되고 있는 저압차단기의 규격동향에 대하여 고찰하였다. IEC TC17은 차단기, 개폐기(스위치), 단로기, 버스관로 및 배전반등과 관련된 IEC 규격의 제 개정을 담당하고 있다. TC17 산하의 SC17B는 저압 차단기, SC17D는 저압배전반제품과 관련된 규격을 관리하고 있다. 한국은 SC17B와 SC 17D의 P-member(Participant)로서 투표권을 갖고 있으며, 한국전기연구원이 운영간사를 맡고 있다. 현재 국내기업체 전문가와 연구원들의 의견을 수렴하여 국가의견으로서 IEC에 제출하고 있지만 앞으로 더 많은 전문가들의 참여가 시급한 실정이다.

  • PDF