• Title/Summary/Keyword: 단락보호

Search Result 125, Processing Time 0.035 seconds

Development of Silm Type ELCB For Airport Distribution Panel through Increased short Circuit Capacity (단락용량 증대를 통한 슬림형 공항 분전반용 누전 차단기 개발)

  • Joo, Nam-Kyu;Lee, Jong-Myong;Kim, Nam-Ho
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.2
    • /
    • pp.360-366
    • /
    • 2012
  • In the power distribution panel installed in airport or industrial facilities, MCCB has been used for main switch and ELCB for branch switch to perform human body and leakage-inducing fire protection as well as overcurrent and short circuit protection. Especially for the airport panel, increase in accident protection is needed for stable power supply due to rapid modernization with fast-growing users, higer capacity and diversification of equipment, the increase of power capacity and the breaker made slim is a main issue for now because the issue for installation space is standing out by making panel with two-row arrangement connection method, etc. due to a many use of branch ELCBs. In this thesis, we designed arc extinguishing mechanism, considered movement direction change of contact in mechanism design. Also, we designed the breaker to work stably in case of miniaturization of leakage detection circuit and reverse connection. We conducted short circuit test to verify its function and developed the breaker that can be improved protection against accidental current with slim size operating leakage function when reverse connection to help solve the problem in using space that is increasing in the airport distribution panel.

A Study on the Operation Characteristics for Protection Coordination Devices of Customer with PV Systems (태양광발전의 연계에 대한 수용가 보호기기의 운용특성에 관한 연구)

  • Kim, Byung-Ki;Lee, Bum-Tae;Jeon, Jin-Teak;Kim, Sub-Han;Rho, Dae-Seok
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.11a
    • /
    • pp.80-84
    • /
    • 2010
  • 본 논문에서는 기존의 배전계통에 연계된 태양광전원에서 발생하는 양방향 보호협조에 대한 문제점을 분석하였다. 모의배전계통과 통합 보호기기장치, 모의 태양광전원장치로 구성된 태양광전원용 보호협조시험장치를 제작하여, 단락사고시험(OCR)과 지락사고시험(OCGR)에 대한 보호기기의 특성시험을 수행하였다. 태양광전원 연계에 의한 사고전류 공급으로 보호기기의 정정치 변동과 보호기기의 오동작, 부동작에 대한 동작특성을 분석하여, 기존의 배전계통에 연계된 태양광전원의 문제점을 분석하고, 그 대안을 제시하였다.

  • PDF

The Thermal Rating of Metallic Case in Under Ground Cable System (지중 전력 케이블 금속보호관의 열적용량)

  • Ahn, M.K.;Kim, J.N.;Kim, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.154-157
    • /
    • 2006
  • 지중 전력케이블의 접속함은 금속보호관(Casing or Protective Tube)의 전기적 검토를 통해서 적정 단면적을 산정하여 고장시 고장전류론 흘려주어야 한다. 현재 국내외 금속보호관은 그 재료로서 Copper를 사용하고 있으나 현장에서의 시공성 및 취급 용이성 때문에 알루미늄 보호관으로 재질 변경이 이루어지고 있다. 본 논문에서는 기존의 Copper보호관과 Aluminium보호관에서의 비교검토를 통해서 Aluminium보호관의 유효성을 검토하고 구리에서 알루미늄으로 재질 변경이 이루어 졌을 때 열적 제약조건을 고려하여 적정단면적을 재 산정한다. 또한 산정된 단면적은 단락시험을 통해서 그 유효성을 입증하였다.

  • PDF

전력계통안정화 보호계전기술

  • 신대승
    • 전기의세계
    • /
    • v.43 no.4
    • /
    • pp.20-26
    • /
    • 1994
  • 전력계통은, 발전기, 변압기, 모선, 선로등을 주요소로 한 많은 설비요소로 구성되며, 이들이 일체로 되어 하나의 안정상태를 유지하면서 운용되고 있다. 전력계통 구성요소중, 특히 가공선로는 지역적으로 널리 분포되어 있으므로, 뢰, 풍우, 염분 등 자연 현상의 영향을 받아 단락, 지락등 계통사고 발생이 불가피하며, 또 다른 구성요소들도 각각 고유한 사고형태와 사고빈도를 가지고 있다. 보호방식은 이들 각종 설비에 사고가 발생하였을 때에, 신속히 사고설비를 계통에서 제거하여, 사고 전류의 계속으로 인한 설비손상을 방지하는 것을 그 기본목표의 하나로 하고 잇다. 그러나 사고발생은 단지 설비의 손상을 가져올 뿐만 아니라, 하나의 안정상태를 유지하고 운용되고 있는 전력계통 전체에 대해서, 이 안정을 무너뜨리는 방아쇠로 작용하며, 사고의 계속, 또는 사고제거에 따른 계통구성의 급변등은 주파수의 저하, 계통탈조, 설비과부하등으로 파급되어 전계통 붕괴로 확대될 가능성을 가지고 있다. 이러한 경향은 전원의 원격화와 집중대용량화, 선로조류의 증가등으로, 계통이 복잡화함에 따라 더 증대하고 있다. 이러한 배경을 바탕으로 하여 보호방식의 책무는, 종전의 설비보호 위주에서 사고파급방지에 의한 계통보호(protection for power system disturbance)로 그 중점목적이 옮겨가고 있으며, 이 사고 파급방지보호장치를 계통안정화장치라고도 한다.

  • PDF

Experimental Study on the Explosion and Fire Risks of Mobile Phone Batteries (휴대폰 배터리의 폭발 및 화재 위험성에 관한 실험적 연구)

  • Lee, Ho-Sung;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.111-120
    • /
    • 2016
  • This is an experimental study to analyze the explosion and fire hazards of mobile phone batteries. Using the lithium-ion batteries currently used on smart phone as the experiment samples, the experiments were conducted by overcharging, internal and external short circuit, and thermal shock with the potential of explosion and fire caused by careless use or abnormal conditions. The experiment results showed that, in the case of overcharging and external short circuit, there was no explosion and fire hazard in the normal operation of the protection circuit module (PCM), but there were big risks when the PCM faulted conditions were assumed. In the case of the experiments by internal short circuit and thermal shock, such risks varied depending on a battery charge state. In other words, it could be verified that there were low risks of explosion and fire in a full discharge state, but there were high risks in a full charge state. These experiment results suggest that to minimize the explosion and fire hazards of mobile phone batteries, an alarm device is necessary when the PCM fault occurs. In addition, a solid battery case should be made and safety equipment, such as a cooling device to avoid high temperature, is needed.

IGBT Gate Drive Design Using Pspice Simulation (Pspice 시뮬레이션을 이용한 IGBT 게이트 드라이브 디자인)

  • 박석인;남광희
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.444-446
    • /
    • 1998
  • Pspice을 사용하여 IGBT의 게이트 드라이브의 동작과 시스템의 단락에 의한 Fault 발생시 IGBT를 보호하기 위해서 밀러 효과에 의한 전류를 게이트 저항을 통하지 않고 이미터로 흐르게 하여 게이트 전압의 상승을 줄여주는 방법을 제안하고 게이트 전압을 낮게 클램핑하는 방법과 비교하였다.

  • PDF

K-D relay에 대한 소고

  • 이광우
    • 전기의세계
    • /
    • v.9
    • /
    • pp.56-57
    • /
    • 1962
  • 우리나라 송전선로중 154송전선의 보호는 새로 거리단전기가 설치됨으로서 과거의 과전류단전방식으로부터 거리단전방식으로 일부 개선하게 되어 앞으로의 기대가 자못크다. 거리단전기는 KD 및 HZ형의 이종이나 그중 대부분은 KD형이다. K-D Relay는 Compensator Relay라고도 불리울 정도로 Compensator의 역할이 중요하다. 이글은 1. 접점동작기구, 2 이종단락개장 검출회로에 대해 서술하였다.

  • PDF

Study on the Explosion and Fire Risks of Lithium Batteries Due to High Temperature and Short Circuit Current (고온 및 단락전류에 따른 리튬배터리의 폭발 및 화재 위험성에 관한 연구)

  • Sim, Sang-Bo;Lee, Chun-Ha;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.114-122
    • /
    • 2016
  • This study is to analyze the explosion and fire risks due to high temperature and short circuit current of Lithium batteries. This study selected the typical types of Li-polymer batteries and Li-ion batteries as the test samples. The result of explosion risk assessment due to the high temperature showed that, while a Li-polymer battery had $170^{\circ}C$ explosion on average, a Li-ion battery had $187^{\circ}C$ explosion. The measurement result of temperature increase due to short circuit current revealed that, in case that protection circuit module (PCM) was normally working, there was little of temperature increase due to over-current limitation. However, in case that PCM was out of order, the temperature of a Li-polymer battery increased up to an average of $115.7^{\circ}C$ and the temperature of a Li-ion battery increased up to an average of $80.5^{\circ}C$, which showed the higher risks of fire and burn.

A Study on Stator Differential Protection Relay (고정자 차동보호계전기에 관한 연구)

  • Park, Chul-Won;Ban, Woo-Hyeon;Gang, Mul-Gyeol;Lee, Won-Seop
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.758-759
    • /
    • 2011
  • 대용량 교류발전기는 전력계통의 중요한 요소이다. 발전기의 사고 중 가장 많이 발생하는 부위는 전기자 권선이다. 보호제어시스템의 효율적인 운용과 향후 차세대 ECMS를 위하여 교류발전기의 보호계전분야에 대한 연구가 필요하다. 해외에서 교류발전기의 단락 및 지락 보호에 관한 Standards들이 제정되었고 발전기의 상세 모델링과 내부권선 사고 모의에 대하여도 계속 연구 중에 있다. 본 논문에서는 고정자의 주보호인 비율차동계전방식의 검출방법, 동작영역 및 특성곡선과 정정치 등을 조사한 후 내부 외부고장의 경우 동작 시뮬레이션을 수행하였다.

  • PDF

The study of the complete protection for ground-fault of the generator stator winding based on the sihwa tidal power plant's hydraulic turbine generator (시화호조력발전소 수차발전기를 모델로 한 발전기 고정자권선 지락사고에 대한 100%보호방안 고찰)

  • Kang, Dong-Hyung;Park, Sung-Ho;Kim, Jong-Deug;Nam, Jin-Geuk;Choi, Hyeong-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.184-186
    • /
    • 2007
  • 절연물의 열화가 진행되면 최초로 1선 지락사고가 발생할 가능성이 많고 1선 지락사고는 2선 지락 및 단락사고로 파급되어 설비에 심각한 손상으로 이어지게 된다. 따라서, 1선지 락 사고에 대한 완전한 보호방식의 적용은 설비 신뢰성 증대라는 측면에서 매우 중요한 사항이라고 판단된다. 이에 시화호조력 발전소에 설치될 수차발전기는 고정자권선의 지락사고에 대한 100%보호방식을 적용하였으며 이 설계사례를 토대로 실제적으로 적용가능한 발전기 고정자권선의 지락보호증대방식을 공유코자 한다.

  • PDF