• 제목/요약/키워드: 다중 검출

검색결과 1,025건 처리시간 0.035초

Commissionning of Dynamic Wedge Field Using Conventional Dosimetric Tools (선량 중첩 방식을 이용한 동적 배기 조사면의 특성 연구)

  • Yi Byong Yong;Nha Sang Kyun;Choi Eun Kyung;Kim Jong Hoon;Chang Hyesook;Kim Mi Hwa
    • Radiation Oncology Journal
    • /
    • 제15권1호
    • /
    • pp.71-78
    • /
    • 1997
  • Purpose : To collect beam data for dynamic wedge fields using conventional measurement tools without the multi-detector system, such as the linear diode detectors or ionization chambers. Materials and Methods : The accelerator CL 2100 C/D has two photon energies of 6MV and 15MV with dynamic wedge an91es of 15o, 30o, 45o and 60o. Wedge transmission factors, percentage depth doses(PDD's) and dose Profiles were measured. The measurements for wedge transmission factors are performed for field sizes ranging from $4\times4cm^2\;to\;20\times20cm^2$ in 1-2cm steps. Various rectangular field sizes are also measured for each photon energy of 6MV and 15MV, with the combination of each dynamic wedge angle of 15o 30o. 45o and 60o. These factors are compared to the calculated wedge factors using STT(Segmented Treatment Table) value. PDD's are measured with the film and the chamber in water Phantom for fixed square field. Converting parameters for film data to chamber data could be obtained from this procedure. The PDD's for dynamic wedged fields could be obtained from film dosimetry by using the converting parameters without using ionization chamber. Dose profiles are obtained from interpolation and STT weighted superposition of data through selected asymmetric static field measurement using ionization chamber. Results : The measured values of wedge transmission factors show good agreement to the calculated values The wedge factors of rectangular fields for constant V-field were equal to those of square fields The differences between open fields' PDDs and those from dynamic fields are insignificant. Dose profiles from superposition method showed acceptable range of accuracy(maximum 2% error) when we compare to those from film dosimetry. Conclusion : The results from this superposition method showed that commissionning of dynamic wedge could be done with conventional dosimetric tools such as Point detector system and film dosimetry winthin maximum 2% error range of accuracy.

  • PDF

The Evaluation of the Radiation Dose and Image Quality Through the Change of the Tube Voltage in Cerebral CT Angiography (전산화단층촬영장치를 이용한 뇌 혈관조영 검사에서 관전압 변화에 따른 방사선량과 영상의 질 평가)

  • LEE, Ji-Won;Jung, Kang-Kyo;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • 제38권2호
    • /
    • pp.121-126
    • /
    • 2015
  • To image diagnosis in neurovascular diseases using Multi-Detector Computed Tomography(MDCT), injected the same contrast material when inspecting Brain Computed Tomography Angiography(BCTA) to examine radiation dose and Image quality on changing Cerebral Artery CT number by tube voltage. Executed an examination with same condition[Beam Collimation $128{\times}0.6mm$, Pitch 0.6, Rotation Time 0.5s, Slice Thickness 5.0mm, Increment 5.0mm, Delay Time 3.0sec, Care Dose 4D(Demension ; D)] except for tube voltage on 50 call patients for BCTA and divided them into two groups (25 people for a group, group A: 80, group B: 120kVp). From all the acquired images, set a ROI(Region of Interest) on four spots such as left cerebral artery, right cerebral artery, posterior cerebral artery and cerebral parenchyma to compare quantitative evaluation, qualitative evaluation and effective dose after measuring CT number value from Picture Archiving Communications System(PACS). Evaluating images with CT number acquired from BCTA examination, images with 80 kVp was 18% higher in Signal to Noise Ratio and 19% in Contrast to Noise Ratio than those with 120 kVp. It was seen that expose dose was decreased by over 50% with tube voltage 80 kVp than with 120 kVp. Group A (25 patients) was examination with tube voltage 80kVp while group B with 120 kVp to examine radiation dose and Image quality. It is considered effective to inspect with lower tube voltage than with conventional high kVp, which can reduce radiation dose without any affect on diagnosis.

Reviews of Radiation Protection and Shielding for Computed Tomography in Foreign Countries (외국의 컴퓨터 단층촬영 장치의 방어시설 문헌 조사)

  • Jahng, Geon-Ho;Yang, Dal-Mo;Sung, Dong-Wook;Lee, Kwang-Yong;Kim, Hyeog-Ju
    • Progress in Medical Physics
    • /
    • 제19권4호
    • /
    • pp.276-284
    • /
    • 2008
  • A computed tomography (CT) is a powerful system for the effectively fast and accurate diagnosis. The CT system, therefore, has used substantially and developed for improving the performance over the past decade, resulting in growing concerns over the radiation dose from the CT. Advanced CT techniques, such as a multidetector row CT scanner and dual energy or dual source CT, have led to new clinical applications that could result in further increases of radiation does for both patients and workers. The objective of this study was to review the international guidelines of the shielding requirements for a CT facility required for a new installation or when modifying an existing one. We used Google Search Engine to search the following keywords: computed tomography, CT regulation or shield or protection, dual energy or dual source CT, multidetector CT, CT radiation protection, and regulatory or legislation or regulation CT. In addition, we searched some special websites, that were provided for sources of radiation protection, shielding, and regulation, RSNA, AAPM, FDA, NIH, RCR, ICRP, IRPA, ICRP, IAEA, WHO (See in Table 1 for full explanations of the abbreviations). We finally summarized results of the investigated materials for each country. The shielding requirement of the CT room design was very well documented in the countries of Canada, United States of America, and United Kingdom. The wall thickness of the CT room could be obtained by the iso-exposure contour or the point source method. Most of documents provided by international organizations were explained in importance of radiation reduction in patients and workers. However, there were no directly-related documents of shielding and patient exposure dose for the dual energy CT system. Based international guidelines, the guideline of the CT room shielding and radiation reduction in patients and workers should be specified for all kinds of CT systems, included in the dual energy CT. We proposed some possible strategies in this paper.

  • PDF

Evaluation of Radiation Exposure Dose for Examination Purposes other than the Critical Organ from Computed Tomography: A base on the Dose Reference Level (DRL) (전산화단층촬영에서 촬영 목적 부위와 주변 결정장기에 대한 피폭선량 평가: 선량 권고량 중심으로)

  • Lee, Seoyoung;Kim, Kyunglee;Ha, Hyekyoung;Im, Inchul;Lee, Jaeseung;Park, Hyonghu;Kwak, Byungjoon;Yu, Yunsik
    • Journal of the Korean Society of Radiology
    • /
    • 제7권2호
    • /
    • pp.121-129
    • /
    • 2013
  • In this study measured patient exposure dose for purpose exposure area and peripheral critical organs by using optically stimulated luminescence dosimeters (OSLDs) from computed tomography (CT), based on the measurement results, we predicted the radiobiological effects, and would like to advised ways of reduction strategies. In order to experiment, OSLDs received calibration factor were attached at left and right lens, thyroid, field center, and sexual gland in human body standard phantom that is recommended in ICRP, and we simulated exposure dose of patients in same condition that equal exposure condition according to examination area. Average calibration factor of OSLDs were $1.0058{\pm}0.0074$. In case of left and right lens, equivalent dose was measure in 50.49 mGy in skull examination, 0.24 mGy in chest, under standard value in abdomen, lumbar spine and pelvis. In case of thyroid, equivalent dose was measured in 10.89 mGy in skull examination, 7.75 mGy in chest, 0.06 mGy in abdomen, under standard value in lumber spine and pelvis. In case of sexual gland, equivalent dose was measured in 21.98 mGy, 2.37 mGy in lumber spine, 6.29 mGy in abdomen, under standard value in skull examination. Reduction strategies about diagnosis reference level (DRL) in CT examination needed fair interpretation and institutional support recommending international organization. So, we met validity for minimize exposure of patients, systematize influence about exposure dose of patients and minimize unnecessary exposure of tissue.

Effect of Dietary Supplementation of Garlic and May Flower Powder on CO2 and CH4 Emission by Hanwoo Cow (산사 및 마늘 분말이 한우암소의 이산화탄소 및 메탄 발생량에 미치는 영향)

  • Kim, Du Ri;Ha, Jae Jung;Song, Young Han
    • Journal of Animal Science and Technology
    • /
    • 제54권5호
    • /
    • pp.363-368
    • /
    • 2012
  • This study was conducted to investigate the effects of dietary garlic and may flower powder on $CO_2$ and $CH_4$ emission by Hanwoo cows fed TMR (Total Mixed Ration) based diet. Animals were housed in a hood-type respiration chamber and the environmental temperature was maintained at $20^{\circ}C$. Gases were measured for 24 hours using the multi-detector instrument gas monitoring system (Mamos-300, Australia). The treatments composed of groups with no intake of garlic and may flower powder (Control), with intake of garlic at 0.5% of DM (T1), with intake of garlic at 1% of DM (T2), with intake of may flower at 0.5% of DM (T3), with intake of may flower at 1% of DM (T4), with intake of garlic and may flower at 0.5% of DM (T5) and with intake of garlic and may flower at 1% of DM (T6). The results indicated that $CO_2$ emission in T3 was 53% lower than that of control (p<0.05), and $CH_4$ emissions was 57% lower than control (p<0.05). Also, the hourly pattern of $CO_2$ and $CH_4$ emissions in T3 showed the least difference with all treatments. Gas emissions pattern peaked after 1 hour of feeding and this gap was wider in the afternoon than in the morning hours.

Surgical Experiences for Non-ST-segment Elevation Acute Coronary Syndrome (ST분절의 상승을 동반하지 않은 급성 관동맥 증후군의 수술 치험)

  • Yu Song-Hyeon;Lim Sang-Hyun;Chang Byung-Chul;Yoo Kyung-Jong;Hong You-Sun
    • Journal of Chest Surgery
    • /
    • 제39권10호
    • /
    • pp.754-758
    • /
    • 2006
  • Background: Surgical role for acute coronary syndrome has been reduced in recent years due to development of drug eluting stent. We evaluated the surgical results of acute coronary syndrome in our hospital. Material and Method: Between January 2001 and August 2005, 416 patients underwent coronary artery bypass grafting (CABG) under diagnosis of non-ST-elevation acute coronary syndrome (NSTE ACS). Mean age was $61.8{\pm}9.0$ years and 276 (66.3%) patients were male. 324 (77.9%) patients had triple vessel disease and 92 (22.1%) had left main disease at angiographic study. 236 (56.7%) patients had hypertension and 174 (41.8%) had diabetes mellitus. Conventional on-pump CABG was performed in 194 patients (46.6%) and off-pump CABG in 222 (53.4%). Total arterial revascularization with no touch technique was done in 97 patients (23.3%). The number of total distal anastomosis was 1,306 and the number per patient was $3.21{\pm}1.71$. Result: Surgical mortality rate was 1.0% (4 patients) and postoperative complication rate was 15.6% (65 patients). Graft patency was checked at mean $3.7{\pm}7.6$ months (from 1 to 37 months) postoperatively with multi-directional computed tomography in 152 patients. Left internal mammary artery was patent in 95.3%, right internal mammary artery in 98.1%, radial artery in 92.2% and saphenous vein in 89.0%. Conclusion: The surgical treatment of NSTE ACS showed relatively low mortality rate and good graft patency rate. Further study is needed to compare the long term results with drug eluting stent.

Added Value of 3D Cardiac SPECT/CTA Fusion Imaging in Patients with Reversible Perfusion Defect on Myocardial Perfusion SPECT (심근관류 SPECT에서 가역적인 병변을 보인 환자의 3차원 심장 SPECT/CTA 퓨전영상의 유용성)

  • Kong, Eun-Jung;Cho, Ihn-Ho;Kang, Won-Jun;Kim, Seong-Min;Won, Kyoung-Sook;Lim, Seok-Tae;Hwang, Kyung-Hoon;Lee, Byeong-Il;Bom, Hee-Seung
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제43권6호
    • /
    • pp.513-518
    • /
    • 2009
  • Purpose: Integration of the functional information of myocardial perfusion SPECT (MPS) and the morphoanatomical information of coronary CT angiography (CTA) may provide useful additional diagnostic information of the spatial relationship between perfusion defects and coronary stenosis. We studied to know the added value of three dimensional cardiac SPECT/CTA fusion imaging (fusion image) by comparing between fusion image and MPS. Materials and Methods: Forty-eight patients (M:F=26:22, Age: $63.3{\pm}10.4$ years) with a reversible perfusion defect on MPS (adenosine stress/rest SPECT with Tc-99m sestamibi or tetrofosmin) and CTA were included. Fusion images were molded and compared with the findings from the MPS. Invasive coronary angiography served as a reference standard for fusion image and MPS. Results: Total 144 coronary arteries in 48 patients were analyzed; Fusion image yielded the sensitivity, specificity, negative and positive predictive value for the detection of hemodynamically significant stenosis per coronary artery 82.5%, 79.3%, 76.7% and 84.6%, respectively. Respective values for the MPS were 68.8%, 70.7%, 62.1% and 76.4%. And fusion image also could detect more multi-vessel disease. Conclusion: Fused three dimensional volume-rendered SPECT/CTA imaging provides intuitive convincing information about hemodynamic relevant lesion and could improved diagnostic accuracy.

Conditions for Artificial Culture of Lemna Paucicostata and Potentiality as an Alternative Biomass Source (바이오매스 자원으로서의 Lemna Paucicostata의 인공배양조건과 이화학적 특성에 관한 연구)

  • Kwag, Jung-Hoon;Lee, Jin-Eui;Kim, Ki-Hye;Eum, Hye-Yeong;Shin, Jong-Suh;Ra, Chang-Six
    • Journal of Animal Environmental Science
    • /
    • 제16권2호
    • /
    • pp.143-152
    • /
    • 2010
  • Conditions for artificial culture of Lemna Paucicostata and its nutritional values were examined in this study. Lemna P. was cultured using artificial wastewater and a bioreactor (total volume $2,630\;cm^3$, working volume $2,240\;cm^3$) was operated at conditions of 6,250 lux and $28^{\circ}C$. Water flow affected the growth of Lemna P.: growth rate was very high (more than $1.1\;d^{-1}$) at a condition of no-water movement, but it was very low (less than $0.15\;d^{-1}$) when water moved slowly. The growth of Lemna P. was higher in $16h\;d^{-1}$ light cycle than in Sand $24h\;d^{-1}$, and it was also severely affected by the initial $NH_4$-N levels of wastewater. The growth rate of Lemna P. was high in lower $NH_4$-N level, indicating that the growth rate is in inverse proportion to $NH_4$-N concentration in wastewater. However, the contents of crude protein (CP) of Lemna P. were proportional to the initial $NH_4$-N concentration. The CP contents of Lemna P. cultured at 2, 10, 50 and 100 $NH_4$-N mg $L^{-1}$ was 18, 24, 37, 43%, respectively, showing the Lemna P. cultured at 50 and $100\;mg\;L^{-1}$ had similar protein contents to linseed (CP 35%), cottonseed (CP 38%) and soybean (CP 45%). Fat, protein, fiber, NDF and ADF contents of Lemna P. harvested at conditions of $16h\;d^{-1}$ light cycle and less than $2\;mg\;L^{-1}$ of $NH_4$-N level was 2.8, 18, 27, 20, 41 and 65.7%, respectively. Since the growth rate of Lemna P. was very high (more than $1.1\;d^{-1}$) at those conditions, it was convinced that mass production of valuable protein and fiber sources are feasible. In particular, since the Lemna P. has unsaturated fatty acids found mainly in animal fat as well as beneficial fatty acids to health such as C18:ln9c, C18:2n6c, C20:5n3 and C22:2, the Lemna P. biomass would be a highly valuable alternative feed source to grains.

The Usefulness of Multidetector CT Arthrography in the Diagnosis of Shoulder Pathology -Comparison with MR Arthrography and Arthroscopic Findings in the Same Patient- (견관절 병변의 진단에서 다중 검출 전산화 단층촬영을 이용한 관절조영술의 유용성 - 동일 환자에서 시행한 자기공명 관절조영술 및 관절경 소견과의 비교 -)

  • Kim, Dong-Soo;Park, Kyoung-Jin;Kim, Yong-Min;Choi, Eui-Sung;Shon, Hyun-Chul;Cho, Byung-Ki;Park, Ji-Kang;Kim, Seok-Won
    • Clinics in Shoulder and Elbow
    • /
    • 제12권2호
    • /
    • pp.115-125
    • /
    • 2009
  • Purpose: The purpose of the study is to evaluate the usefulness of CT arthrography (CTA) by conducting a comparative study of CTA and MR arthrography (MRA) with the arthroscopic findings in the same patients. Materials and methods: Forty nine patients who suffered from shoulder disease underwent MRA and CTA concurrently. The sensitivity and specificity of CTA was evaluated, as compared to MRA, in the case of four types of shoulder pathological lesions. The accuracy of CTA was evaluated by analyzing the arthroscopic findings of thirty four patients. Results: Compared to MRA, CTA showed a sensitivity of 90% and a specificity of 100% for diagnosing supraspinatus tendon (SST) full thickness tear, and CTA showed a sensitivity of 100% and a specificity of 97.5% for making the diagnosis of superior labrum anterior to posterior (SLAP) lesion. For diagnosing partial articular side supraspinatus avulsion (PASTA) lesion, some studies have shown the usefulness of CTA with a sensitivity of 71.4% and a specificity of 97.7%. However, for diagnosing SST bursal side partial tear, the sensitivity of CTA was as low as 10%. CTA has been shown to be relatively accurate when the diagnoses were verified with the arthroscopic findings; diagnosing SST full thickness tear and SLAP lesion with CTA has shown an accuracy of 100% and87.5% respectively, and CTA showed 71.4% diagnostic accuracy for PASTA lesion. Conclusion: CTA was a useful tool and it was equivalent to MRA for the assessment of SST full thickness tear, SLAP lesion and PASTA lesion, but not bursal side partial tear. Thus, it may be used preferably to diagnose shoulder pathology and for follow up as an inexpensive tool after operation.

Determination of plasma C16-C24 globotriaosylceramide (Gb3) isoforms by tandem mass spectrometry for diagnosis of Fabry disease (패브리병(Fabry) 진단을 위한 혈장 중 Globotriaosylceramide (Gb3)의 탠덤매스 분석법 개발과 임상 응용)

  • Yoon, Hye-Ran;Cho, Kyung-Hee;Yoo, Han-Wook;Choi, Jin-Ho;Lee, Dong-Hwan;Zhang, Kate;Keutzer, Joan
    • Journal of Genetic Medicine
    • /
    • 제4권1호
    • /
    • pp.45-52
    • /
    • 2007
  • Purpose : A simple, rapid, and highly sensitive analytical method for Gb3 in plasma was developed without labor-ex tensive pre-treatment by electrospray ionization MS/ MS (ESI-MS/MS). Measurement of globotriaosy lceramide (Gb3, ceramide trihex oside) in plasma has clinical importance for monitoring after enzyme replacement therapy in Fabry disease patients. The disease is an X-linked lipid storage disorder that results from a deficiency of the enzyme ${\alpha}$-galactosidase A (${\alpha}$-Gal A). The lack of ${\alpha}$-Gal A causes an intracellular accumulation of glycosphingolipids, mainly Gb3. Methods : Only simple 50-fold dilution of plasma is necessary for the extraction and isolation of Gb3 in plasma. Gb3 in diluted plasma was dissolved in dioxane containing C17:0 Gb3 as an internal standard. After centrifugation it was directly injected and analyzed through guard column by in combination with multiple reaction monitoring mode of ESI-MS/MS. Results : Eight isoforms of Gb3 were completely resolved from plasma matrix. C16:0 Gb3 occupied 50% of total Gb3 as a major component in plasma. Linear relationship for Gb3 isoforms w as found in the range of 0.001-1.0 ${\mu}g$/mL. The limit of detection (S/N=3) was 0.001 ${\mu}g$/mL and limit of quantification was 0.01 ${\mu}g$/mL for C16:0 Gb3 with acceptable precision and accuracy. Correlation coefficient of calibration curves for 8 Gb3 isoforms ranged from 0.9678 to 0.9982. Conclusion : This quantitative method developed could be useful for rapid and sensitive 1st line Fabry disease screening, monitoring and/or diagnostic tool for Fabry disease.

  • PDF