• Title/Summary/Keyword: 다공성콘크리트

Search Result 91, Processing Time 0.03 seconds

Engineering Properties for Planting of Porous Concrete Block Containing Rice Straw Ash (볏짚재를 혼입한 다공성콘크리트 블록의 식생을 위한 공학적 특성)

  • Sung Chan-Yong;Kim Young-Ik
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.3 s.81
    • /
    • pp.311-318
    • /
    • 2004
  • This study was performed to examine engineering properties for planting of porous concrete block containing rice straw ash. Tests for void ratio, compressive and flexural strength, pH by neutralization treatment time and curing method were peformed. As results, the void ratio tends to decrease with increasing rice straw ash content. But, the compressive and flexural strength tends to increase with Increasing rice straw ash content. When the neutralization was treated at the curing age 6 days, the greatest strength was showed. The pH of porous concrete without neutralization treatment in dry and water curing are shown in 10.32 ${\~}$ 10.55 and 9.41${\~}$9.59, respectively. The pH of porous concrete by neutralization treatment in dry and water curing were shown in 9.74${\~}$10.10 and 8.13${\~}$9.32, respectively. The porous concrete block size was 23 ${\times}$ 23 ${\times}$ 4 cm, and species of planting were Tall fescue, Lespedeza cyrtobotrya and Lespedeza cuneata. At the 6 months after seeding, germination ratio and grown-up length of Tall fescue, Lespedeza cyrtobotrya and Lespedeza cuneata were shown in 90, 60, $50\%$, and 40${\~}$50, 90${\~}$110, 65${\~}$75 cm, respectively. These porous concrete block containing rice straw ash could be used for planting.

Evaluation of Mechanical Properties of Porous and Pervious Light-weight Concrete by Mixing Proportion (다공성, 투수성 경량콘크리트의 배합비에 따른 물리적 특성 평가)

  • Ahn, Hwi-Soon;Shin, Hyun-Oh;SeonWoo, Yoon-Ho;Song, Si-Bum;Jung, Kwang-Sik;Yoon, Young-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.305-306
    • /
    • 2010
  • Recently, concrete have been used not only for structural purpose but also for various other purposes. The goal of this research is to develop porous and pervious light-weight concrete in order to apply to filters, which primarily treats rain water. Because Porous and pervious light-weight concrete is discontinuum with large amount of porosity, its physical characteristic is completely different from that of ordinary concrete. The basic properties such as the change in porosity rate depending on mixing proportion and the mechanical characteristics of porous and pervious light-weight concrete were experimentally evaluated.

  • PDF

Estimation of Water Purification Ability with Applying Porous Concrete to Weir and Riverbed Materials (다공성 콘크리트의 보 및 하상재료 적용에 따른 하천 수질정화 능력 평가)

  • Choi, I-Song;Kim, Jin-Hong;Choi, Gye-Woon;Oh, Jong-Min
    • Journal of Korea Water Resources Association
    • /
    • v.36 no.6
    • /
    • pp.1013-1023
    • /
    • 2003
  • This study was performed to improve water quality of stream by applying hydraulic structures (weir and river bed material) made of porous concrete. The physical and chemical characteristics of porous concrete were measured to estimate application possibility of it in hydraulic structures and it was considered as a proper material for the hydraulic structures. In the results of comparison for the component of matters attached on the hydraulic structures made of porous and ordinary concrete, DW (dry weight) amount attached on porous concrete was 1.6 times higher than that on ordinary concrete under the condition of the same flow rate but influence by flow rate (difference of 10 times) was not shown. Therefore, we could understand that the material of media was more important in DW amount than flow rate. The rate of AFDM (ash free dry mass) to DW also was more at porous concrete than at ordinary concrete. Especially, the high rates of nitrogen and phosphorous in matters attached on porous concrete verify that they were removed by assimilation, adsorption and metabolism of periphyton. The removal percentage of SS, BOD, COD, T-N and T-P by hydraulic structures applying porous concrete compared with ordinary concrete was increased by 34.6%, 36.9%, 33.9%, 18.3% and 21.6%, respectively. Therefore, applying porous concrete to hydraulic structure is expected to contribute to improvement of stream water quality.

An Experimental Study on Thermal Property of Porous Concrete Containing Bottom Ash (바텀애시를 활용하는 다공성 콘크리트의 열전도 특성에 관한 실험 연구)

  • Jeong, Seung-Tae;Kim, Bum-Soo;Park, Ji-Hun;Yang, In-Hwan
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.4
    • /
    • pp.625-632
    • /
    • 2021
  • In this paper, the applicability of bottom ash to insulation concrete was investigated to increase the utilization of bottom ash. Bottom ash was used as the aggregates in porous concrete and extensive experiments were conducted to investigate the characteristics of porous concrete using two types of bottom ash aggregates. The water-binder ratios of 0.25 and 0.35 were chosen and concrete specimens was produced with the compaction of 0.5, 1.5, and 3.0MPa to analyze the material properties at different compaction conditions. After concrete specimens were cured for 28 days at water tanks, unit weight, total void ratio, and thermal conductivity were measured. Based on the measured experimental results, the relationships between the unit weight, total void ratio, and thermal conductivity of porous concrete containing bottom ash was presented.

Effect of Reinforcing Fiber on Mechanical Properties and Chemical Resistance of Porous Concrete with Hwang-toh (황토를 포함한 다공성 식생콘크리트의 역학적 특성 및 내약품성에 미치는 보강섬유의 효과)

  • Lee, Jin-Hyung;Park, Chan-Gi;Park, Jong-Sik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.2A
    • /
    • pp.105-113
    • /
    • 2011
  • This study evaluated the effects of fibers on the mechanical properties and chemical solution resistance of porous concrete with fiber type (jute, pulp, PVA and nylon fiber) and fiber volume fraction (0.0%, 0.1%, 0.2%, 0.3%). The tests that were carried out to analysis the properties of porous concrete included compressive strength, void ratio, pH value, and chemical solution exposure with varying type and volume fraction of fiber were conducted. The type and volume fraction of fiber also affected the void ratio, compressive strength, flexural strength and chemical solution exposure. Increased volume fractions of fiber resulted in improved properties of the compressive strength, flexural strength and void ratio. However, the difference between the measured pH value and chemical resistance of porous concrete with fiber type and volume fraction was not significant.

Correlation Analysis between Unit Weight and Thermal Conductivity in Porous Concrete Containing Natural Fine and Bottom Ash Aggregates (바텀애시와 천연 잔골재를 혼입한 다공성 콘크리트의 단위질량과 열전도도의 상관분석)

  • Seung-Tae Jeong;In-Hwan Yang
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.4
    • /
    • pp.542-551
    • /
    • 2023
  • In this paper, the thermal properties of porous concrete containing natural fine aggregates in bottom ash aggregates were analyzed. In this study, natural fine aggregates were used for bottom ash aggregates to understand the material properties of each aggregate and then used as an aggregate for porous concrete. A porous concrete specimen was manufactured by fixing the water-binder ratio at 0.25 and designating the compaction at 0.5, 1.5, and 2.5 MPa. Unit weight, total void ratio and thermal conductivity test were measured and discussed. As the compaction increased and the mixing ratio of natural fine aggregates increased, the unit weight and thermal conductivity increased, and the total void ratio decreased. In addition, the correlations between unit weight, total void ratio and thermal conductivity of porous concrete with previous experimental data were presented and the correlation coefficient (R2) was also analyzed.

Evaluation of Load Capacity and Toughness of Porous Concrete Blocks Reinforced with GFRP Bars (GFRP 보강 다공성 콘크리트 블록의 내력 및 인성 평가)

  • Jung, Seung-Bae;Yang, Keun-Hyeok
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.5
    • /
    • pp.403-409
    • /
    • 2017
  • In this study, mix proportioning of porous concrete with compressive strength and porosity exceeding 3MPa and 30%, respectively, was examined and then load capacity and flexural toughness of the porous concrete block were evaluated according to the different arrangements of the GFRP bars. To achieve the designed requirements of porous concrete, it can be recommended that water-to-cement ratio and cement-to-coarse aggregate ratio are 25% and 20%, respectively, under the aggregate particle distribution of 15~20mm. The failure mode of porous concrete blocks reinforced with GFRP bars was governed by shear cracks. As a result, very few flexural resistance of the GFRP was expected. However, the enhanced shear strength of porous concrete due to the dowel action of the GFRP bars increased the load capacity and toughness of the blocks. The porous concrete blocks reinforced with one GFRP bar at each compressive and tensile regions had 2.1 times higher load capacity than the companion non-reinforced block and exhibited a high ductile behavior with the ultimate toughness index ($I_{30}$) of 43.4.

바이오 폴리머를 사용한 친환경 포장의 적용

  • Lee, Tae-Hyeong;O, Yeong-Tak;Gang, Mu-Seok;Lee, Jung-U
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2018.11a
    • /
    • pp.43-45
    • /
    • 2018
  • 근래 국내 해안에서도 해수면의 상승에 따른 파랑에너지의 증가로 인해 해안침식 현상에 대처하기 위한 연구를 계속해오고 있다. 본 연구는 다공성 골재 포장 재료인 투수 바이오 콘크리트를 해안의 침식사면에 적용하고 현장 모니터링을 통해 파력저감 및 세굴방지와 식생이 복원된 효과를 확인하였다. 호안 사면의 시공과 함께 생겨날 수 있는 바닷가 친수공간에 다공성 포장으로 산책로를 시공하여 오염물질의 해안 유입을 저감하여 해안 생태계를 보호하는데 기여한다. 또한, 하천에서 적용한 사례를 제시하여 해안으로 연결되는 하천을 보호하는데 다공성 포장을 적용할 수 있음을 제시하였다.

  • PDF

Strength Properties of Porous Concrete Containing Natural Fine Aggregate and Bottom Ash Aggregate (천연 잔골재와 바텀애시 골재를 활용한 다공성 콘크리트의 강도 특성)

  • Seung-Tae Jeong;Ji-Hun Park;In-Hwan Yang
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.3
    • /
    • pp.192-201
    • /
    • 2023
  • In this paper, the strength properties of porous concrete containing natural fine aggregates and bottom ash aggregates were investigated, The material properties of natural fine aggregates and bottom ash were identified then used as aggregates for porous concrete. The water-binder ratio was constant at 0.25, and the com paction level of 0.5, 1.5, and 2.5 MPa was applied to produce a porous concrete specimen. Test of unit weight, ultrasonic velocity, compressive strength, and flexural tensile strength were perform ed and analyzed. The unit weight, ultrasonic velocity, com pressive strength, and flexural tensile strength increased as the compaction level increased and also the replacement rate of bottom ash with sand(fine aggregate) increased. In addition, through regression analysis, the correlation between the unit weight, compressive strength, and flexural tensile strength of bottom ash porous concrete was presented. Unit weight and strength properties are proportional to each other and showed an increasing correlation. In addition, the correlation coefficient (R2) value of regression analysis was calculated based on the experimental results of this study and those of other research papers.