• Title/Summary/Keyword: 누수신호

Search Result 32, Processing Time 0.031 seconds

Analysis on Signal Properties due to Concurrent Leaks at Two Points in Water Supply Pipelines (상수도 배관에서 두 지점의 동시 누수에 따른 신호특징 분석)

  • Lee, Young-Sup
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.1
    • /
    • pp.31-38
    • /
    • 2015
  • Intelligent leak detection is an essential component of a underground water supply pipeline network such as a smart water grid system. In this network, numerous leak detection sensors are needed to cover all of the pipelines in a specific area installed at specific regular distances. It is also necessary to determine the existence of any leaks and estimate its location within a short time after it occurs. In this study, the leak signal properties and feasibility of leak location detection were investigated when concurrent leaks occurred at two points in a pipeline. The straight distance between the two leak sensors in the 100A sized cast-iron pipeline was 315.6 m, and their signals were measured with one leak and two concurrent leaks. Each leak location was described after analyzing the frequency properties and cross-correlation of the measured signals.

Analysis of the effect of leakage on water head reduction in the pilot scale pipeline connected to the field pipeline. (현장 관망과 연결된 Pilot 스케일 관로에서 누수가 수두감쇠에 미치는 영향 분석)

  • Lee, Jeongseop;Ko, Dongwon;Lee, Taekwan;Yun, Seokjun;Choi, Dooyong;Kim, Sanghyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.400-400
    • /
    • 2022
  • 관로 내 빈번히 발생하는 수격압의 발생은 관망 구조물에 피로가 누적되고 관벽에 손상을 발생시켜, 관로 내 누수가 다양한 형태로 생성된다. 관 내 누수가 발생되는 경우 관 내부의 수격압의 발생 시 생성되는 부압으로 인하여 외부 물질이 관으로 흡수되거나 혼합되어 스케일과 미생물의 생성되는 등 관 내의 수질에 악영향을 끼치며 마찰을 증가시켜 통수능이 감소하고 관리에 추가적인 비용을 발생시킨다. 이러한 영향을 방지하기 위해 관 내에서 생성되는 누수를 탐지하기 위하여 수격압을 발생시켜 압력파를 분석하거나 추적을 수행하는 여러 가지 연구들이 수행되었다. 본 연구에서는 현장 관망과 연결된 100A 대구경 관로에 관로 수압 발생장치를 연결하여 기존의 수격압을 발생시켜 분석하는 방법 대신 안전하고 용이한 방법인 압력파를 주입하여 실험을 수행하였다. 실험을 통해 획득한 데이터를 시간상에서 분석하고 Fourier 변환을 통한 빈도상 분석과 Wavelet 분석으로 신호주기에서 누수가 미치는 영향을 파악하였다. 실험 결과에서는 누수에 의한 영향으로 반사파가 직접적으로 변형되는 형태보다 시스템 전체에서 반영되어 수두가 감쇠되는 형태로 나타났다. Fourier 변환을 통해 무누수 조건과 누수조건의 비교에서 누수의 유무에 따른 신호의 형태가 차이를 보였다. 앞선 연구들에서의 누수의 특정한 위치를 찾아내는 형태 대신 신호처리 후 분석을 통해 시스템 전체에서 일어나는 감쇠를 통해 누수 존재 유무를 판별하고자 한다.

  • PDF

A Fundamental Study on Leak Detection System for Water Supply Valve Using Smart Bolt (상수도 밸브 누수 탐지용 스마트 볼트 적용의 기초 연구)

  • Park, Chul;Kim, Young-seok;Jung, Hae-Wook;Choi, Sang-sik;Lee, Yong-Beom
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.1
    • /
    • pp.144-154
    • /
    • 2020
  • Purpose: This paper is a fundamental study on the applicability of the smart bolt developed for monitoring system to detect the leakage of water supply valve. Method: A leak detection experiments were conducted using the smart bolt having embedded strain sensors and accelerometer. The smart bolt used in study meets the allowable criteria of torque and tensile stress for water supply system, and it can be applied to a joint of the water supply valve by behaving well within the allowable limits. Result: As a result of the simulated leak tests, a leak signal at the valve leak point was detected in a band of 60Hz, and the main pipe leaking point was observed to produce a leak signal having much higher frequency than that of the valve leak point. This seems to result in a total coupled vibration under unconfined conditions of the pipes. Conclusion: The smart bolts appeared applicable to detecting a leaking signal from the water supply valve.

Wireless Water Leak Detection System Using Sensor Networks (센서네트워크를 이용한 무선 누수 탐지 시스템)

  • Choi, Soo-Hwan;Eom, Doo-Seop
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.48 no.3
    • /
    • pp.125-131
    • /
    • 2011
  • Water leak detection system is a system based on wireless sensor networks(WSNs) which detect a leak on water supply, localize the leak position and finally inform a water management center. A traditional leak detection method is to use experienced personnel who walk along a pipeline listening to the sound that is generated by the leaks and their effectiveness depend on the experience of the user. Also making more successful detection, it should be processed at middle of the night when people do not use water, as the result users have to operate the leak detection system at midnight. In this paper, we propose a new method for the water leak detection system based on the WSNs and describe it in detail. Leak detection devices which detect a leakage of water transmit and receive the result of water leak detection with each other by configuring WSNs to improve reliability of the detection result. Also, we analyzed the sound from water flowed in pipeline, proposed the pre-signal processing to separate a leakage sound from noisy sound. And lastly, It is especially important to make a time synchronization with water leak detection devices that are installed on the pipeline, we used 1PPS(1 Pulse Per Second) signal generated by GPS, therefore we could get a precise time synchronization. The proposed system set up in Namyangju and performances were evaluated.

Leak Location Detection of Underground Water Pipes using Acoustic Emission and Acceleration Signals (음향방출 및 가속도 신호를 이용한 지하매설 상수도배관의 누수지점 탐지연구)

  • Lee, Young-Sup;Yoon, Dong-Jin;Jeong, Jung-Chae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.3
    • /
    • pp.227-236
    • /
    • 2003
  • Leaks in underground pipelines can cause social, environmental and economical problems. One of relevant countermeasures against leaks is to find and repair of leak points of the pipes. Leak noise is a good source to identify the location of leak points of the pipelines. Although there have been several methods to detect the leak location with leak noise, such as listening rods, hydrophones or ground microphones, they have not been so efficient tools. In this paper, acoustic emission (AE) sensors and accelermeters are used to detect leak locations which could provide all easier and move efficient method. Filtering, signal processing and algorithm of raw input data from sensors for the detection of leak location are described. A 120m-long pipeline system for experiment is installed and the results with the system show that the algorithm with the AE sensors and accelerometers offers accurate pinpointing of leaks. Theoretical analysis of sound wave propagation speed of water in underground pipes, which is critically important in leak locating, is also described.

Determination of Phase Velocity Dispersion Curve and Group Velocity of lamb Waves Using Backward Radiation (후방복사를 이용한 램파의 위상속도 분산과 군속도의 측정)

  • 송성진;권성덕;정용무;김영환
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.1
    • /
    • pp.61-68
    • /
    • 2003
  • The guided wave has been widely employed to characterize thin plates and layered media. The dispersion curves of phase and group velocities are essential for the quantitative application of guided waves. In the present work, a fully automated system for the measurement of backward radiation of LLW has been developed. The specimen moves in two dimensional plane as well as in angular rotation. The signals of backward radiation of LLW were measured from an elastic plate in which specific modes of Lamb wave were strongly generated. Phase velocity of the corresponding modes was determined from the incident angle. The generated Lamb waves propagated forward and backward with the leakage of energy into water. Backward radiated LLW was detected by the same transducer and its frequency components were analyzed to extract the related information to the dispersion curves. The dispersion curves of phase velocity were measured by varying the incident angle. Moving the specimen in the linear direction of LLW propagation, group velocity was determined by measuring the transit time shift in the ultrasonic waveform.

The leak signal characteristics and estimation of the leak location on water pipeline (상수도관의 누수신호 특성 및 누수지점 추정에 관한 연구)

  • Park, Sangbong;Kim, Kibum;Seo, Jeewon;Kim, Jueon;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.5
    • /
    • pp.461-470
    • /
    • 2018
  • In this study, the leak signal was measured by using an accelerometer to analyze the basic data and methodology for the development of the leak point estimation method in the water supply pipe. The measured results were analyzed by frequency analysis and cross-correlation analysis for leakage signals, and the error range was compared and analyzed with the actual leak point distance. As a result, it was confirmed that the vibration intensity due to leakage from the water leakage point was attenuated according to the distance. In the case of the ductile iron casting used in the experiment, the intensity of the signal at the 945 Hz, 1,500 Hz, 2,300 Hz band was increased with the change of the pressure in the pipe at 4mm of leakage hole. Also, it was confirmed that as the water pressure increases, the intensity of the leak signal increases but the similarity of the signal decreases. The results of this study confirm that the accelerometer sensor can be used efficiently for leak detection and it can be used as a basic data for the analysis for the development of leak point estimation method in the future.

Development of leakage test facility for leak signal characteristic analysis in water pipeline (상수도관로 누수신호의 특성 분석을 위한 누수 실험시설 개발)

  • Park, Sanghyuk;Kwak, Philljae;Lee, Hyundong;Choi, Changho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.5
    • /
    • pp.459-469
    • /
    • 2017
  • A real scale leakage test facility was developed to study the leak signal characteristics of water supply pipelines, and then leak tests were carried out. The facility was designed to overcome the limited experimental circumstances of domestic water supply pipeline experimental facilities. The length of the pipeline, which was installed as a straight line, is 280m. Six pipes were installed on a 70m interval with different pipe material and diameters that are DCIP(D200, D150, D100, D80), PE(D75) and PVC(D75).The intensity of the leakage is adjusted by changing the size of the leak hole and the opening rate of ball valve. Various pressure conditions were simulated using a pressure reducing valve.To minimize external noise sources which, deteriorate the quality of measured leak signal, the facility was built at a quiet area, where traffic and water consumption by customers is relatively rare. In addition, the usage of electric equipment was minimized to block out noise and the facility was operated using manual mode. From the experimental results of measured leakage signal at the facility, it was found that the signal intensity weakened and the signal of high frequency band attenuated as the distance from the water leakage point increased.

Development of TDR-based Water Leak Detection Sensor for Seawater Pipeline of Ship (시간영역반사계를 이용한 해수배관시스템의 누수 탐지용 센서 개발 연구)

  • Hwang, Hyun-Kyu;Shin, Dong-Ho;Kim, Heon-Hui;Lee, Jung-Hyung
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.6
    • /
    • pp.1044-1053
    • /
    • 2022
  • Time domain reflectometry (TDR) is a diagnostic technique to evaluate the physical integrity of cable and finds application in leak detection and localization of piping system. In this study, a cable-shaped leak detection sensor was proposed using the TDR technique for monitoring leakage detection of ship's engine room seawater piping system. The cable sensor was developed using a twisted pair arrangement and wound by an absorbent material. The availability and performance of the sensor for leak detection and localization were evaluated on a lab-scale pipeline set up. The developed sensor was installed onto the pipes and flanges of the lab-scale set up and various TDR waveforms were acquired and analyzed according to the dif erent variables including the number of twists and sheath thickness. The result indicated that the twisted cable sensor was able to produce clear and smooth signal as compared to the TDR sensor with a parallel arrangement. The optimal number of twist was determined to be above 10 per the unit length. The optimal diameter of sheath thickness that results in the desired sensitivity was determined to be ranging from 80% up to 120% of the diameter of the conductor. The linear regression analysis for estimation of leak localization was carried out to estimate the location of the leakage, and the result was a determination coefficient of 0.9998, indicating a positive relationship with the actual leakage point. The proposed TDR based leak detection method appears to be an effective method for monitoring leakage of ship's seawater piping system.

Improved Estimation of Leak Location of Pipelines Using Frequency Band Variation (주파수 대역 변화를 이용한 배관의 누수지점 추정 개선 연구)

  • Lee, Young-Sup;Yoon, Dong-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.1
    • /
    • pp.44-52
    • /
    • 2014
  • Leakage is an important factor to be considered for the management of underground water supply pipelines in a smart water grid system, especially if the pipelines are aged and buried under the pavement or various structures of a highly populated city. Because the exact detection of the location of such leaks in pipelines is essential for their efficient operation, a new methodology for leak location detection based on frequency band variation, windowing filters, and probability is proposed in this paper. Because the exact detection of the leak location depends on the precision of estimation of time delay between sensor signals due to leak noise, some window functions that offer weightings at significant frequencies are applied for calculating the improved cross-correlation function. Experimental results obtained by applying this methodology to an actual buried water supply pipeline, ~ 253.9 m long and made of cast iron, revealed that the approach of frequency band variation with those windows and probability offers better performance for leak location detection.