• Title/Summary/Keyword: 누수관리

Search Result 241, Processing Time 0.033 seconds

Leakage Detection of Water Distribution System using Adaptive Kalman Filter (적응 칼만필터를 이용한 상수관망의 누수감시 기법)

  • Kim, Seong-Won;Choi, Doo Yong;Bae, Cheol-Ho;Kim, Juhwan
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.10
    • /
    • pp.969-976
    • /
    • 2013
  • Leakage in water distribution system causes social and economic losses by direct water loss into the ground, and additional energy demand for water supply. This research suggests a leak detection model of using adaptive Kalman filtering on real-time data of pipe flow. The proposed model takes into account hourly and daily variations of water demand. In addition, the model's prediction accuracy is improved by automatically calibrating the covariance of noise through innovation sequence. The adaptive Kalman filtering shows more accurate result than the existing Kalman method for virtual sine flow data. Then, the model is applied to data from two real district metered area in JE city. It is expected that the proposed model can be an effective tool for operating water supply system through detecting burst leakage and abnormal water usage.

Development of Standard Guideline for Water-leakage and Maintenance by parts of the Underground Structures in Multi-Family Housing - A Case Analysis of Water Leak Diagnosis - (공동주택 지하구조물의 부위별 표준 누수 진단 유지관리 지침 개발 - 누수 진단 사례 분석 -)

  • Kim, Soo Yeon;Lee, Jung Hun;Song, Je Young;Jang, Duk Bae;Oh, Sang Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.142-143
    • /
    • 2017
  • An analysis of the current water leak status of understand structure (underground parking lots, staircases, plumbing systems, water reservoirs, etc.) of multi-family housing in South Korea shows that water leaks are found from cracks in all areas of the underground structure caused by the degradation environment (water pressure by underground water, humidity, temperature, earth pressure, soil behaviour and vibration, etc.), which result in various problems, including mold, malodour, debonding of finishing materials, exfoliation, breakout, water leaks in electrical boxes, efflorescence, sedimentation of calcium hydroxide, decoloration, rusting, damages and pollution among others. Therefore, this study aims to analyse the current status of water leaks in underground structure and use the results as the basic data for developing a standard guideline for water leaks and maintenance by parts of the underground structure of multi-family housing.

  • PDF

A Study on the Flaw Prevention Countermeasure of Crack in Apartment House Underground Parking Area (아파트 지하주차장의 균열방지 대책 - 현장사례조사를 중심으로 -)

  • Jung Soon-Oh;Suh Sang-Wook
    • Korean Journal of Construction Engineering and Management
    • /
    • v.3 no.1 s.9
    • /
    • pp.115-123
    • /
    • 2002
  • Recently all basement floor of apartment site have utilized as parking area to use efficiently space and to ensure lawful parking car figure. And the top of parking area has used as working vehicle's path and materials' carrying area during construction. Thus because crack and leakage status in underground parking area of under construction or completion building generate excessively not only performance of structure is diminished but also flaw repair cost is put in a lot of. And abroad confidence is diminish. So this study is intended to diminish flaw focus on investigation of under construction and completion fields through examine closely cause of crack and leakage status of apartment house underground parking area and prepare countermeasure with respect to design, construction and maintenance.

Technical Index for the Maintenance of Watertightness of the Roof of a Large-Span Membrane Structure (대공간 막 구조물 지붕의 수밀성능 확보를 위한 유지관리 지표 연구)

  • Oh, Sang-Keun;Kim, Dong-Bum;Lee, Sun-Gyu
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.1
    • /
    • pp.51-59
    • /
    • 2011
  • With the increased demand for membrane structures in recent years, there have been many studies of their mechanical properties, to the extent that such structures have become recognized as independent structures with a level of safety and durability comparable to those of other general structures. But in reality, the study for the maintenance of membrane structures has not been as active. In particularly, the study of watertightness from the perspective of maintenance has been very limited. Accordingly, a study on securing watertightness performance and the guidelines for maintenance is necessary. In this study, through a case study of water leakage accidents in membrane structures overseas, causes of leakage were selected from the membrane material itself, joint parts and open door of roof part in membrane structure. The water leakage and deterioration elements were analyzed from those leakage causes. The degree of importance of the water leakage and deterioration index was also designated using the AHP (Analytic Hierarchy Process) method. As a result, the basic technical index was suggested for the maintenance of the roofs of large-span membrane structures to prevent water leakage. This index will be used to make a guideline for the long-term maintenance of the roofs of large-span membrane structures.

Detection of the Pipe Leak for Water Distribution System Using Ground Penetrating Radar (GPR을 이용한 상수관로의 누수 탐사)

  • Park, In-Chan;Cho, Won-Cheol
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1271-1274
    • /
    • 2006
  • 지하레이다(Ground Penetrating Radar, GPR)를 이용하여 지표하의 상수관로를 지표에서 송신안테나와 수신안테나를 이용해서 손쉽게 측정하게 된다. 송신안테나는 지표하에 전자기파를 송신하고 지하 매질을 투과한 파가 수신안테나에 도달하는 시간을 측정하여 지표하 매질의 특성을 파악할 수 있다. 수신파의 도달시간은 지표하 매질의 특성에 따라서 변화하며, 이를 통해 지표하 매질과 매질 깊이 등을 파악할 수 있다. 일반적으로 상수관로를 매설할 경우 관로 주변의 토양은 균등하게 되므로 기 매설된 상수관로 주변에 누수가 발생하게 되면, 관로 주변의 토양은 포화상태이거나 수압으로 인해서 공동이 형성될 경우가 많다. 이때 반사에너지의 유전율 증가 혹은 감소 특성으로 인해서 주변 매질과는 매우 상이한 결과를 보이게 된다. GPR탐사는 단순히 반사된 신호진폭의 크기를 나타내며 이러한 반사에너지의 크기에 관계되는 것은 매설물의 유전율이 주위 지반이 갖는 유전율과의 차이에서 기인하기 때문이다. 탐사 대상 상수관로에 대한 정보를 확보하여 GPR 탐사를 수행한 결과 관로 탐사를 위한 GPR의 결과는 매우 유용하게 사용될 것으로 판단되며, 이를 바탕으로 누수 발생 이력이 있는 다양한 관로주변 조건을 대상으로 탐사를 실시할 경우 상수관망시스템의 효율적인 관리 및 보수에 매우 유용한 방법이 될 수 있을 것으로 판단된다.

  • PDF

Memory Leak Detection Using Adaptive Cyclic Memory Allocation (동적 순환 메모리 할당 기법을 이용한 메모리 누수 검출)

  • Lim, Woo-Sup;Han, Hwan-Soo;Lee, Sang-Won
    • Journal of KIISE:Software and Applications
    • /
    • v.37 no.10
    • /
    • pp.760-767
    • /
    • 2010
  • There are many memory leak detection tools. However, programmers, who develop very large programs, tend to avoid testing their programs with memory leak detection tools since these tools require runtime and space overheads. Thus, we present a memory leak detection technique which enables programmers to test their modules in their unit test phase with low overheads. To achieve this goal, we extend the existing cyclic memory allocation technique and evaluate our memory leak detection technique on a tiny DBMS. In our experiments, we find our tool has reasonably low runtime and space overheads and it reports only a small number of false positives.

Reduction Techniques of the Pipe Line net Using According to DVGW (DVGW이론에 따른 상수관망의 부식방지를 위한 정수처리방안)

  • Choo Tai-Ho;Kim Ha-Il
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2005.11a
    • /
    • pp.115-118
    • /
    • 2005
  • Leakage of waterworks pipe line net cause loss of water resources, additional foundation of pressurization facilities from pressure loss and soil weakening near leaked pipe line, etc. This is difficult to maintain and manage waterworks pipe line net and to cause serious economic loss. Rate of accounted water is better by monitoring always water pressure and flux, etc. from isolated region, positively dealing with leakage accident and preventing leakage from occurring. Actually after isolating region, average rate of accounted water in this region is 88.94% by continuously monitering control of water pressure and inflow rate. It is about 9.44% more than that of Busan metropolitan city in 2003, 79.5%.

  • PDF

Model Development of Event Detection System Software in Water Distribution Networks (상수관망 수리이상감지시스템 SW(K-EDS) 모델 개발)

  • Noh, Joon Woo;Shin, Eun Her;Yoo, Do Guen
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.270-270
    • /
    • 2017
  • 스마트워터그리드와 같은 첨단 정보통신기술을 활용한 물 관리 기술의 도입으로 수도운영사업에서도 누수와 같은 이상사건인지 목적의 효율적 빅 데이터 분석기법의 중요성이 증대되고 있다. 국내외적으로 누수인지를 위한 다양한 연구기법, 범위, 계측항목, 샘플링 주기 등이 제시된 바 있으나, 이상감지시스템(Event Detection System, EDS)은 대상지역 특정적 특성을 가지고 있어 범용적인 모델을 구축하는 데는 어려움이 있다. 본 연구에서는 소블럭 단위의 유량자료 분석을 통한 이상감지시스템의 적용가능여부를 판별하고 적합 모델구축자료 방안을 제시하는 K-EDS 모델을 개발하였다. 모델분석의 절차는 자료획득, 자료 전처리, 탐색적 자료해석, 그리고 각 기법 평가로 진행된다. 개발된 모델을 다양한 특성을 가지는 실제 지방상수도시스템에 적용하여 분석하였으며, 최종적으로 모델적용 가능성과 영향인자 등을 도출하였다. 개발된 모델은 소블럭별 현장계측자료 기반의 이상감지모델 적용 적합도 판별에 활용될 수 있으며, 향후 누수 인지 및 누수지속시간 감소를 위한 SW로 개발이 가능하다.

  • PDF