• Title/Summary/Keyword: 누설파

Search Result 109, Processing Time 0.026 seconds

Noise Analysis and Measurement for a CW Bio-Radar System for Non-Contact Measurement of Heart and Respiration Rate (호흡 및 심박수 측정을 위한 비접촉 방식의 CW 바이오 레이더 시스템의 잡음 분석 및 측정)

  • Jang, Byung-Jun;Yook, Jong-Gwan;Na, Won;Lee, Moon-Que
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.9
    • /
    • pp.1010-1019
    • /
    • 2008
  • In this paper, we present a noise analysis and measurement results of a bio-radar system that can detect human heartbeat and respiration signals. The noise analysis including various phase noise effects is very important in designing the bio-radar system, since the frequency difference between the received signal and local oscillator is very small and the received power is very low. All of the noise components in a bio-radar system are considered from the point of view of SNR. From this analysis, it can be concluded that the phase noise due to antenna leakage is a dominant factor and is a function of range correlation. Therefore, the phase noise component with range correlation effect, which is the most important noise contribution, is measured using the measurement setup and compared with the calculated results. From the measurement results, our measurement setup can measure a closed-in phase noise of a free-running oscillator. Based on these results, it is possible to design a 2.4 GHz bio-radar system quantitatively which has a detection range of 50 cm and low power of 1 mW without additional PLL circuits.

Electrical Characteristics of High Power Multilayer Piezoelectric Transformer Fabricated using Atrrition Milling Method (Attrition Milling법으로 제작된 고출력 적층 압전변압기의 전기적 특성)

  • Oh, Young-Kwang;Seo, Byeong-Ho;Yoo, Ju-Hyun;Kim, In-Sung;Song, Jae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.18-18
    • /
    • 2010
  • 전기적 에너지를 기계적 에너지로 변환하고 또한, 기계적 에너지를 전기적 에너지로 변환할 수 있는 압전 세라믹스는 압전 변압기 (piezoelectric transformer), 초음파 모터, 센서 등과 같은 응용분야에 광범위하게 사용되고 있다. 특히, 전원장치에 있어서 현재 주요 전자제품에 사용되고 있는 권선형 변압기와 같은 전자 변환기의 대체품으로 압전 세라믹스 소재의 특성을 이용한 압전변압기의 개발과 응용연구는 국내외적으로 활발히 연구되어왔다. 압전변압기는 권선형 변압기와 비교 하였을 때 누설자속이 없어 노이즈 발생이 없고, 공진주파수만을 이용하므로 출력의 파형이 정현파에 가까워 고조파 잡음이 없으며, 불연성의 특징을 가지고 있다. 추가적으로 압전 변압기는 소형화, 슬림화, 경량화가 가능하며 90%이상의 높은 효율을 얻을 수 있다. 또한, 단판형 압전변압기의 출력한계를 개선하기 위해 높은 승압비와 고출력을 갖는 적층타입의 압전변압기가 제안되었다. 압전변압기용 조성 세라믹스는 높은 에너지 변환효율을 위해서 전기기계결합계수 ($k_p$)가 커야 하며, 발열에 의한 온도 상승을 억제하기 위하여 기계적 품질계수(Qm)가 큰 것이 바람직하다. 또한, 높은 전류를 발생하기 위해서는 유전상수가 커 압전변압기의 출력측 정전용량을 크게 하여야한다. 이러한 압전변압기의 제작 조건을 위해 우수한 압전 및 유전특성을 갖는 PZT계 세라믹스가 주로 사용 되어져 왔다. 그러나, PZT계 세라믹스의 우수한 압전 및 유전특성에도 불구하고 $1000^{\circ}C$에서 급격히 휘발하는 PbO의 성질 때문에 환경적으로나 인체의 건강문제로 인해 전세계적으로 그 사용량을 제한하고 있다. 또한 적층 압전변압기의 구조적 특성상 내부전극과 함께 소결하여야 하는데, 이때 소결온도가 높으면 값비싼 Pd합량이 높은 전극을 사용하여야 한다. Pd함량이 10%미만인 Ag/Pd 전극을 사용하기 위해서는 $950^{\circ}C$ 이하에서 저온소결이 가능한 세라믹스 제조가 필수적이라 할 수 있다. 소결온도를 낮추는 방법으로는 다른 물질들을 치환하여 소결온도를 낮추는 방법과 미세분말을 만들어 그레인사이즈를 미세화 하는 방법들이 있다. 많은 미세 분말 제조 방법 중에서 Attrition mill은 일반적인 ball mill에 비해 분말의 입도를 미세하게 할 수 있어 증가된 분말의 비표면적에 의하여 반응을 촉진시킴으로써 저온소결이 가능한 세라믹스를 만들 수 있다. 따라서 본 연구에서는 소결온도가 낮으면서도 유전 및 압전특성이 우수한 조성을 사용하여 적층 압전변압기를 제작하여 전기적 특성을 조사하였다.

  • PDF

Input and Output Characteristics of Input Current Controlled Inverter Arc Welding Machine with High Efficiency (입력전류 제어형 고효율 인버터아크용접시스템의 입력 및 출력 특성연구)

  • 최규하
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.4
    • /
    • pp.358-369
    • /
    • 2000
  • Shielded metal arc welding machines with AC transformer have been widely used for thin-plate welding applications. Because of being bulky, heavy and of tap-changing property, so the SMAW's are changing to new power electronic circuits such as inverter circuit in order to reduce the system size and also to improve the welding performances at input output sides. The PWM inverter arc welding machine with diode rectifier has better output welding performances but it is has the plentiful harmonics and the lower input power factor. To solve these problems, input current-controlled scheme is considered for PWM inverter arc welding system, and then total input power factor is maintained to be more than 99%. Also a new combined control is proposed which can control both instantaeous welding output voltage and current under constant power condition, and as a result the variations of instantaneous current and voltage can be reduced to very narrow range in the V-I curve relationship, and hence the variance of welding current and voltage become so reduced. In addition the spatter generated during welding process is greatly reduced up to 70%. And the overall effiency can be improved up to 10%, which becomes higher when the load is lower.

  • PDF

High-Efficiency CMOS Power Amplifier using Low-Loss PCB Balun with Second Harmonic Impedance Matching (2차 고조파 정합 네트워크를 포함하는 저손실 PCB 발룬을 이용한 고효율 CMOS 전력증폭기)

  • Kim, Hyungyu;Lim, Wonseob;Kang, Hyunuk;Lee, Wooseok;Oh, Sungjae;Oh, Hansik;Yang, Youngoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.2
    • /
    • pp.104-110
    • /
    • 2019
  • In this paper, a complementary metal oxide semiconductor(CMOS) power amplifier(PA) integrated circuit operating in the 900 MHz band for long-term evolution(LTE) communication systems is presented. The output matching network based on a transformer was implemented on a printed circuit board for low loss. Simultaneously, to achieve high efficiency of the PA, the second harmonic impedances are controlled. The CMOS PA was fabricated using a $0.18{\mu}m$ CMOS process and measured using an LTE uplink signal with a bandwidth of 10 MHz and peak to average power ratio of 7.2 dB for verification. The implemented CMOS PA module exhibits a power gain of 24.4 dB, power-added efficiency of 34.2%, and an adjacent channel leakage ratio of -30.1 dBc at an average output power level of 24.3 dBm.

Development of a Ranging Inspection Technique in a Sodium-cooled Fast Reactor Using a Plate-type Ultrasonic Waveguide Sensor (판형 웨이브가이드 초음파 센서를 이용한 소듐냉각고속로 원격주사 검사기법 개발)

  • Kim, Hoe Woong;Kim, Sang Hwal;Han, Jae Won;Joo, Young Sang;Park, Chang Gyu;Kim, Jong Bum
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.1
    • /
    • pp.48-57
    • /
    • 2015
  • In a sodium-cooled fast reactor, which is a Generation-IV reactor, refueling is conducted by rotating, but not opening, the reactor head to prevent a reaction between the sodium, water and air. Therefore, an inspection technique that checks for the presence of any obstacles between the reactor core and the upper internal structure, which could disturb the rotation of the reactor head, is essential prior to the refueling of a sodium-cooled fast reactor. To this end, an ultrasound-based inspection technique should be employed because the opacity of the sodium prevents conventional optical inspection techniques from being applied to the monitoring of obstacles. In this study, a ranging inspection technique using a plate-type ultrasonic waveguide sensor was developed to monitor the presence of any obstacles between the reactor core and the upper internal structure in the opaque sodium. Because the waveguide sensor installs an ultrasonic transducer in a relatively cold region and transmits the ultrasonic waves into the hot radioactive liquid sodium through a long waveguide, it offers better reliability and is less susceptible to thermal or radiation damage. A 10 m horizontal beam waveguide sensor capable of radiating an ultrasonic wave horizontally was developed, and beam profile measurements and basic experiments were carried out to investigate the characteristics of the developed sensor. The beam width and propagation distance of the ultrasonic wave radiated from the sensor were assessed based on the experimental results. Finally, a feasibility test using cylindrical targets (corresponding to the shape of possible obstacles) was also conducted to evaluate the applicability of the developed ranging inspection technique to actual applications.

The Effect of Ar/O2 Partial Pressure Ratio on the Ferroelectric Properties of (Pb0.92La0.08)(Zr0.65Ti0.35)O3 Thin Films Deposited by RF Magnetron Sputtering Method (RF Magnetron Sputtering법으로 제작된 (Pb0.92La0.08)(Zr0.65Ti0.35)O3 박막의 Ar/O2 분압비에 따른 강유전 특성연구)

  • Kim, Sang-Jih;Yoon, Ji-Eon;Hwang, Dong-Hyun;Lee, In-Seok;Ahn, Jung-Hoon;Son, Young-Guk
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.2
    • /
    • pp.141-146
    • /
    • 2009
  • PLZT ferroelectric thin films were deposited on Pt/Ti/$SiO_2$/Si substrate with $TiO_2$ buffer layer in between by rf magnetron sputtering method. In order to investigate the effect of Ar/$O_2$ partial pressure ratio on the ferroelectric properties of PLZT thin films, PLZT thin films were deposited at various Ar/$O_2$ partial pressure ratio ; 27/1.5 seem, 23/5.5 seem, 21/7.5 seem and 19/9.5 seem. The crystallinities of PLZT thin films were analyzed by XRD. The surface morphology was observed using FE-SEM. The P-E hysteresis loops, the remanent polarization characteristics and the leakage current characteristics were obtained using a Precision LC. The crystallinity and elaborateness of PLZT thin films were decreased as increasing the oxygen partial pressure ratio. And preferred orientation of PLZT thin films changed from (110) plane to (111) plane. The oxygen partial pressure ratio affects the thin film surface morphology and the ferroelectric properties.

Human Effect for Commercial Wireless Power Transfer System Operating at Low Frequency (상용 자기유도방식 무선전력전송 시스템의 인체영향 분석)

  • Kang, Jun-Seok;Lee, Seungwoo;Hong, Ic-Pyo;Cho, In-Kui;Kim, Nam
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.5
    • /
    • pp.382-390
    • /
    • 2017
  • In this paper, we consider particular exposure scenarios to evaluate human effects for inductive commercial wireless charging device operating at low frequency. The coil used in this study is the A10 model in Qi standard proposed by WPC(Wireless Power Consortium), and input power is 5 W to the operating frequency of 155 kHz. In perfectly aligned condition, the max leakage magnetic field is $257.58{\mu}T$ which is obtained at the side of the device, and it is exceeded about 7.4 times of the ICNIRP 1998 reference level. The SAR is evaluated with homogeneous phantom which has electric constants of wet skin. The max value of the SAR is $134.47{\mu}W/kg$ which is obtained at the side of the device also, and it is much lower than the international guidelines. Especially, it showed higher SAR values in case of misalignment condition, so we will need to consider the misalignment condition importantly when we evaluate human effects for wireless power transfer system.

Electrical Characteristics Measurement of Eddy Current Testing Instrument for Steam Generator in NPP (원전 증기발생기 와전류검사 장치의 전기적 특성 측정)

  • Lee, Hee-Jong;Cho, Chan-Hee;Yoo, Hyun-Joo;Moon, Gyoon-Young;Lee, Tae-Hun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.5
    • /
    • pp.465-471
    • /
    • 2013
  • A steam generator in nuclear power plant is a heatexchager which is used to convert water into steam from heat produced in a nuclear reactor core, and the steam produced in steam generator is delivered to the turbine to generate electricity. Because of damage to steam generator tubing may impair its ability to adequately perform required safety functions in terms of both structural integrity and leakage integrity, eddy current testing is periodically performed to evaluate the integrity of tubes in steam generator. This assessment is normally performed during a reactor refueling outage. Currently, the eddy current testing for steam generator of nuclear power plant in Korea is performed in accordance with KEPIC & ASME Code requirements, the eddy current testing system is consists of remote data acquisition unit and data analysis program to evaluate the acquired data. The KEPIC & ASME Code require that the electrical properties of remote data acquisition unit, such as total harmonic distortion, input & output impedance, amplifier linearity & stability, phase linearity, bandwidth & demodulation filter response, analog-to-digital conversion, and channel crosstalk shall be measured in accordance with the KEPIC & ASME Code requirements. In this paper, the measurement requirements of electrical properties for eddy current testing instrument described in KEPIC & ASME Code are presented, and the measurement results of newly developed eddy current testing instrument by KHNP(Korea Hydro & Nuclear Power Co., LTD) are presented.

Detection of Cavities Behind Concrete Walls Using a Microphone (마이크로폰을 이용한 콘크리트 벽체 배면의 공동 탐사)

  • Kang, Seonghun;Lee, Jong-Sub;Han, WooJin;Kim, Sang Yeob;Yu, Jung-Doung
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.12
    • /
    • pp.19-28
    • /
    • 2022
  • Cavities behind concrete walls can adversely affect the stability of structures. Thus study aims to detect cavities behind concrete structures using a microphone in a laboratory model test. A small-scale concrete wall is constructed in a chamber, which is composed of a reinforced concrete plate and dry soil. A plastic bowl is then placed between the plate and soil to simulate a cavity behind the concrete structure. Leaky surface acoustic waves are generated by impacting the concrete plate using a hammer and are measured using a microphone. The measured signals are analyzed using natural frequencies, and cavity-free sections are evaluated. The test results show that the first natural frequency decreases at the cavity section due to the flexural vibration behavior of the plate. In addition, the amplitude corresponding to the first natural frequency decreases as the measurement location becomes farther from the cavity center and significantly decreases at the measurement locations near the rebars. This study demonstrates that a microphone may be useful to detect cavities behind concrete walls.