• Title/Summary/Keyword: 뇌혈관 검사

Search Result 92, Processing Time 0.028 seconds

Analysis of the Entrance Surface Dose (ESD) and Contrast Usage of Trance Femoral Cerebral Angiography (TFCA) and Cerebral Computed Tomographic Angiography (CCTA) for Cerebrovascular Disease Examining (뇌혈관 질환 검사를 위한 뇌혈관 조영술(TFCA)과 뇌혈관 전산화 단층 촬영 검사(CCTA)의 입사표면선량(ESD) 및 조영제 사용량 분석)

  • Seo, Young-Hyun;Hong, Cheon-Gi;Song, Jong-Nam
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.495-502
    • /
    • 2019
  • A typical cerebrovascular disease among cerebrovascular diseases is vascular diseases such as cerebral infarction, cerebral hemorrhage, cerebral aneurysm, cerebrovascular stenosis. If the disease occurs and causes cerebral damage, it may be difficult to recover completely. So that, Must continue to perform health care through examination early. In particular, Because most cerebrovascular disease examining use radiation equipment and Thus this study was to find out how to select about the optimal examining method and X-ray dose decrease method among different examining method though comparison and analysis for the entrance surface dose (ESD) on cerebrovascular examining with Trance Femoral Cerebral angiography (TFCA) and Cerebral Computed Tomographic Angiography (CCTA). Also, want to find out how to select about the optimal examining method for worried patient that contrast medium side effect though measuring and evaluating for contrast usage. Data were collected from 70 patients (43 males and 27 females) who underwent CCTA at Yeosoo region hospital from June 2018 to December 2018 and 61 patients (34 males and 27 females) who underwent TFCA at Pyeongtaek region hospital from June 2018 to November 2018. ESD analysis method collected retrospective data though M-view and PACS PLUS program, Used contrast usage measuring method did reality measuring method. In the analysis using SPSS, the ESD of TFCA was $245.74{\pm}71.91$, which was $32.05{\pm}7.74$ lower than the dose of $277.79{\pm}79.65$ of CCTA ESD, and statistically significant at t = 3.249, p = 0.017 (p<0.05). As a result of the comparison of the total amount of contrast agent, the mean contrast agent used in TFCA was $55.05{\pm}17.68ml$, which was about 14.95 smaller than the amount of contrast agent used in CCTA, and statistically significant t = -4.548, p<0.001. In conclusion, the ESD of TFCA was statistically significantly lower than that of CCTA, and also the used contrast usage was significantly tiny than that of CCTA. Therefore, Select the method to increase the utilization of TFCA for cerebral disease examining, we can consider X-ray dose decrease method at the same time as to decrease side effect of contrast medium.

Comparative Evaluation of Single-Energy CT and Dual-Energy CT in Brain Angiography : Using a Rando Phantom and OSLD (뇌혈관조영검사 시 단일에너지 CT와 이중에너지 CT의 비교평가 : 화질 및 유효선량평가)

  • Byeong-Geun Shin;Seong-Min Ahn
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.809-817
    • /
    • 2023
  • Single source and dual source measurements using anthropomorphic phantoms in which the phantoms are lined up in human body equivalents use OSLD (Optically Stimulated Luminescence Dosimeter), so the effective dose is calculated using OSLD. For hospital images, SNR (Signal to Noise Ratio) and CNR (Contrast to Noise Ratio) were measured in MCA (Middle Cerebral Artery) for single source and dual source, and for phantom images, SNR and CNR were measured for brain parenchyma of single source and dual source. For hospital imaging, SNR and CNR were measured in MCA for both single-source and dual-source, and for phantom images, SNR and CNR were measured for brain parenchyma from single-source and dual-source. As a result of comparing the SNR and CNR of the hospital image and the phantom image, there was no statistical difference. Comparing patient doses in hospital images, the effective dose of the dual source was 53.53% less and the effective dose of the dual energy phantom was 57.94% less. The dose can be increased in other areas, but the cerebrovascular area is useful because the dose is small.

A Hospital-based Case-control Study on the Risk Factors of Cerebrovascular Disease (뇌혈관질환의 위험요인에 대한 환자 - 대조군 연구)

  • Kim, Jang-Rak;Hong, Dae-Yong;Park, Sung-Hak
    • Journal of Preventive Medicine and Public Health
    • /
    • v.28 no.2 s.50
    • /
    • pp.473-486
    • /
    • 1995
  • A hospital-based, matched case-control study was carried out to evaluate the relation ship of various suspected risk factors including snoring and serum level of cholesterol to cerebrovascular disease in Korea. A total of 127 incident cases of cerebrovascular disease(74 cases of cerebral infarction and 53 cases of intracerebral hemorrhage) admitted to. the department of neurology in a university hospital from December, 1993 to March, 1995 were compared with 127 matched controls admitted to same hospital in same period. A multivariate analysis suggested that ECG abnormality(left ventricular hypertrophy and atrial fibrillation), family history of cerebrovascular disease, fundoscopic abnormality, previous history of transient ischemic attack and hypercholesterolemia were risk factors of cerebrovascular disease, ECG abnormality, fundoscopic abnormality, smoking and hypercholesterolemia were also suggested as risk factors of cerebral infarction.

  • PDF

Factor Analysis on Cerebrovascular Disease of Korean Police Officers (한국 경찰관들의 뇌혈관 질환 요인 분석)

  • Jeon, WooJin;Cho, Jaehwan
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.4
    • /
    • pp.293-299
    • /
    • 2013
  • The aim of this study is to investigate the correlation cerebrovascular disease factors in police officers, to provide basic data for a systematic and effective resource management of police officers in the future. This study was conducted on police officers who visited the national police hospital and who underwent MRI for the diagnosis of cerebrovascular diseases. In study result, the probability of cerebrovascular disease was 1.63 times higher in patients with a hypertension. And, the probability of cerebrovascular disease was 1.95 times higher in patients with a Cardiovascular disease. Beside, the probability of cerebrovascular disease was 0.54 times higher in patients with a drinking. And, the probability of cerebrovascular disease was 0.32 times higher in patients with a high homocysteine level.

Assessment of Image Quality of Dual Energy 256 MDCT Technique Focused on keV Changes for MCA Stroke in Cerebral Angiography : Single Energy CT Standard Reference Mode (뇌혈관 조영 검사 시 중대뇌동맥 뇌졸중에 대한 keV 변화를 중심으로 이중 에너지 256 MDCT 기법의 영상의 질 평가 : 단일에너지 CT 표준방식)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.961-968
    • /
    • 2019
  • The purpose of this study was to evaluate the usefulness of cerebral angiography in each energy level by using dual energy technique in CT. Methods were performed on 15 DE images and SE images of CT angiography. For the analysis of images, mean value, standard deviation, SNR and CNR value were determined by setting ROI on MCA, brain parenchyma tissue, and back ground. As a result of concurrent visual evaluation with Likert 5 point scale, the clearest MCA image was confirmed at DE 40 keV and SE 120 kVp(p>0.05). The SNR value of the SE image was measured to be similar to the 40 keV energy level of the DE image. The low energy level image of 40 keV and 50 keV was measured with a high SNR and the contrast ratio was higher than that of the high energy image.

A Study on Selection of Optimal Imaging Diagnostic Device for Cerebral Angiography: Focusing on MRA, CTA, and DSA Imaging Diagnosis Devices (뇌혈관 검사 시 최적의 영상 진단장치 선정에 관한 연구: MRA, CTA, DSA, 영상 진단장치 중심으로)

  • Byun, Jung-Su;Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.637-645
    • /
    • 2017
  • The objective of this study was to find the optimum test device for the cerebral blood vessels by comparing and analyzing the SNR and CNR methods for images of three devices (i.e., MRA, CTA, and DSA). The study targeted 90 patients who underwent cerebral angiography from November 2016 to May 2017. The measuring parts were measured by using Rt MCA, Lt MCA, and ACA Image J. The results of quantitative analysis showed that the mean SNR of MRA, the CNR of MRA, the signal strength of MRA, the mean SNR of CTA, the CNR of CTA, the signal strength of CTA, the SNR of DSA, the CNR of DSA, and the signal strength of DSA were evaluated as 254.87, 178.13, 326.81, 74.75, 62.2, 356.66, 26.85, 25.89, and 4400.69, respectively (p<0.05). As a result, both SNR and CNR methods measured it in the order of MRA>CTA>DSA. Statistical significance was determined by using ANOVA analysis at p<0.05 and Bonferroni method was used as a post-hoc analysis SPSS. In conclusion, the results of this study revealed that the optimum imaging devices were MRA, CTA, and DSA after evaluating randomly selected patients with cerebrovascular disease.

당뇨병의 뇌혈관질환

  • Son, Hyeon-Sik
    • The Monthly Diabetes
    • /
    • s.194
    • /
    • pp.28-31
    • /
    • 2006
  • 뇌졸증 예방을 위해서는 대부분의 당뇨병환자에서 혈당조절 이외에 동반된 여러 위험인자들을 같이 교정해주는 것이 중요하다. 또한 환자에게 당뇨병이 뇌졸증의 위험인자임을 인식하도록하고 이에 상응하는 증상이 발생할 경우에는 적절한 시간 내에 병원을 방문하여 검사를 받도록 하여야 한다.

  • PDF

A Study on the Clinical Usefulness of MMSE and BCRS for Cognitive Function Test in Patients with Non-Traumatic Subcortical Cerebrovascular Disease (비외상성 피질하 뇌혈관질환 환자에서 인지평가도구로서 정신상태소검사(MMSE)와 간이인지평가척도(BCRS)의 임상적 유용성에 대한 연구)

  • Choi, Hong;Lee, Young-Ho;Choi, Young-Hee;Ko, Dae-Kwan;Chung, Young-Cho;Park, Byoung-Kwan;Kim, Soo-Ji;Chung, Sook-Haui;Ko, Byoung-Hee;Song, Il-Byoung;Park, Kun-Woo;Lee, Dae-Hie
    • Sleep Medicine and Psychophysiology
    • /
    • v.3 no.1
    • /
    • pp.68-78
    • /
    • 1996
  • Objective : The Mini-Mental State Examination(MMSE) and Brief Cognitive Rating Scale(BCRS) are frequently using screening tests fur evaluating the cognitive function in clinical practice and research. The authors tried to evaluate the clinical usefulness of these tests for the patients with non-traumatic subcortical cerebrovascular disease. Method : We administered the MMSE and BCRS to 85 patients and 195 normal control group. In order to compare the test results according to the lesion site, we divided patients into left sided lesion group(21 patients), right sided lesion group(31 patients) and both sided lesion group(13 patients). Their cognitive function was evaluated by the BNA and daily living functional activity was examined by the IADLs(Instrumental Activities of Daily Living Scale)and GERRI(Geriatric Evaluation by Relative's Rating Instrument). Results : The results are as follows : 1) In the BNA, the patients scored significantly lower than control group at all items(except Right-Left Orientation and Motor Impersistence), but there were no difference in the MMSE(total score and all 5 items), and only 2 items(recent memory and self-care) were significantly different between two groups in the BCRS. 2) In the comparison by lateralization, there were significant differences among three groups at 3 items(Left Tactile Form Perception, Left Finger Localization and Right Finger Localization) in the BNA. But, there were no difference in the MMSE and BCRS. 3) In the correlation between daily living functioning and the MMSE/BCRS, control group showed no relation(except item of cognitive functioning), but patient group was significantly correlated with 3 items(social functioning, instrumental activities of daily living and cognitive functioning). Conclusions : These findings suggest that MMSE and BCRS are not useful as the test for cognitive function and discrimination of lateralization in patients with non-traumatic subcortical cerebrovascular disease. However, scores of these tests may be related with the functional level(such as daily living function) of patients.

  • PDF