• Title/Summary/Keyword: 농도교류

Search Result 40, Processing Time 0.027 seconds

Characteristics of Electrical Properties, Ozone Generation and Decomposition of Volatile Organic Compounds by Nonthermal Plasma Reactor Packed with SBT Ferroelectric (SBT 강유전체 충전층 저온 플라즈마 반응기의 전기적 특성, 오존생성 및 휘발성유기화합물의 분해)

  • Eo, Joon;Kim, Il Won;Park, Jin Do;Lee, Joo Young;Lee, Hak Sung
    • Applied Chemistry for Engineering
    • /
    • v.22 no.3
    • /
    • pp.249-254
    • /
    • 2011
  • A nonthermal plasma reactor in conjunction with a tubular type with a ferroelectric (high-dielectric ceramic) pellet layer was designed and constructed. $SrBiTaO_9$ (SBT) pellets with 2.0 mm in diameter were held within the tube arrangement by two metal mesh electrodes (20 mm separation) connected to a high-voltage AC power supply. The dielectric constant of SBT pellets was 150 at room temperature and 500 at curie temperature ($335^{\circ}C$). The generation rate of ozone in the plasma reactor almost linearly increased with increasing applied voltage. In the case of the plasma reactor packed with SBT pellets the generation rate of ozone sharply increased at the applied voltage more than 20 kV. The ozone generation rate at the negative corona discharge was higher than that of the positive corona discharge. However, the destruction efficiency of toluene and methylene chloride was not increased in proportion to ozone concentration.

Electrode Characteristics of K+ Ion-Selective PVC Membrane Electrodes with AC Impedance Spectrum (AC 임피던스 분석법을 이용한 K+ 이온선택성 PVC막 전극 특성)

  • Kim, Yong-Ryul;An, Hyung-Hwan;Kang, An-Soo
    • Applied Chemistry for Engineering
    • /
    • v.9 no.6
    • /
    • pp.870-877
    • /
    • 1998
  • With impedance spectrum measurements, impedance was studied in the interface between sample solutions for $K^+-ion$ selective PVC membrane electrode containing neutral carriers [dibenzo-18-crown-6 (D18Cr6) and valinomycine (Val)]. Response characteristics of electrode were examined by measuring AC impedance spectra that were resulted from the chemical structure and the content of carrier, variation of plasticizer, membrane thickness, doping of base electrolytes, and concentration variation of sample solution. Transport characteristics of PVC membrane electrode were also studied. It was found that the equivalent circuit for the membrane in $K^+$ solution could be expressed by a series combination of solution resistance and a parallel circuit consisting of the bulk resistance and geometric capacitance of the membrane system. But the charge transfer resistance and Warburg resistance were overlapped a little in the low concentration and low frequency ranges. The carrier, D18Cr6 was best for electrode and impedance characteristics, and ideal electrode characteristics were appeared especially in case of doping of the base electrolyte[potassium tetraphenylborate(TPB)]. The optimum carrier content was about 3.23 wt% in case of D18Cr6 and Val. DBP was best as a plasticizer. As membrane thickness decreased the impedance characteristics was improved, but electrode characteristics were lowered for membrane thickness below the optimum. In the case of D18Cr6, the selectivity coefficients by the mixed solution method for the $K^+$ ion were the order of $NH_4{^+}>Ca^{2+}>Mg^{2+}>Na^+$.

  • PDF

Factors Affecting Electrofusion of Plant Protoplasts (식물 Protoplast의 전기자극 융합에 관여하는 인자)

  • Han, Sung-Kyu;U, Zang-Kual;Kang, Soon-Suon;Riu, Key-Zung;Oh, Sung-Gug
    • Applied Biological Chemistry
    • /
    • v.33 no.1
    • /
    • pp.93-100
    • /
    • 1990
  • The optimum conditions of electric stimulation for electrofusion of protoplasts of petunia, carrot and soybean, and the effects of calcium, magnesium, protease, trypsin, triton X-100, concanavalin A, dimethyl sulfoxide(DMSO), glycerol monooleate and spermine on fusion frequency and/or viability of petunia protoplast were investigated. The optimum frequencies(Hz)-amplitudes(V/cm) of AC Pulse for protoplast pearl-chain formation were 10 kHz-20 V/cm and 1 MHz-60 V/cm for petunia, 100 kHz-40 V/cm and $1\;MHz-40{\sim}60\;V/cm$ for carrot, and $1\;MHz-40{\sim}80\;V/cm$ for soybean, respectively. The optimum condition of DC pulse treatment at the 1 MHz-60 V/cm-15sec treatment of AC for electrofusion of petunia protoplasts was 2.5 kV/cm-40 sec, and under this condition the fusion frequency and viability of protoplasts were 45 % and 10 %, respectively, Both of the protoplasts of carrot and soybean were not fused under the AC and DC conditions tested in this experiment. The electrofusion of petunia protoplasts was stimulated by calcium, and the fusion frequency and the viability of the protoplasts were 43 % and 11 % , respectively at the calcium concentration of 140 mM. Although fusion frequency was not affected by magnesium only, magnesium stimulated fusion frequency in the presence of calcium, and the viability and fusion frequency of petunia protoplasts were 45 % and 13 %, respectively, at 140 mM of magnesium-140 mM of calcium. The relative fusion frequencies of petunia protoplasts to the controls were increased by 2.4, 2.1, 1.6, 1.4, 1.8, 1.5 and 2.2 folds, respectively, by the treatments of protease, trypsin, triton X-100, concanavalin A, DMSO, glycerol monooleate, and spermine. The viabilities of petunia protoplasts were decreased by these substances.

  • PDF

Provenance and Metallurgical Study on Bronze Mirrors Excavated from Mireuksaji Temple Site, Iksan (익산 미륵사지 출토 동경의 금속학적 연구 및 산지 추정)

  • Huh, Il-Kwon;Cho, Nam-Chul;Kang, Hyung-Tae
    • Journal of Conservation Science
    • /
    • v.20
    • /
    • pp.23-30
    • /
    • 2007
  • By analyzing the chemical compositions of bronze mirror presumably excavated from Mireuksaji temple site, Iksan, we have surveyed what alloy composition was used in casting the mirror, and also tried to estimate the manufacturing technique of the bronze mirror, through the observation of microstructure, as well as which region$^{\circ}{\emptyset}s$ galena the lead used in the mirror belonged to, by analyzing the ratio of the lead isotope. The content analysis result of bronze mirrors shows that it consists of 68.8 to 73.3wt% of Cu, 21.6 to 24.9wt% of Sn. In particular, the content of Pb of Mireuk 2 and 3 Samples are higher than those of Miruk 4. The observation result of microstructure demonstrates that Mireuk 2 and 3 consist of ${\alpha}$ and ${\alpha}+{\delta}$ eutectoide phase made through casting process. But Mireuk 4 show other process employed, such as quenching though martensite structure. In the analysis result of provenance though the lead isotope ratio, the origin of the used in bronze millers excavated from Mireuksaji temple site is presumed to be from galenas of Japen, like this those, the chemical competition, microstructure, and lead isotope ratio of bronze mirrors excavated from Mireuksaji can be utilized at fundamental data to compare mutually with other remains.

  • PDF

Electrical Discharge Plasma in a Porous Ceramic Membrane-supported Catalyst for the Decomposition of a Volatile Organic Compound (다공질 세라믹지지 촉매 상에서의 플라즈마 방전을 이용한 휘발성유기화합물의 분해)

  • Jo, Jin-Oh;Lee, Sang Baek;Jang, Dong Lyong;Mok, Young Sun
    • Applied Chemistry for Engineering
    • /
    • v.24 no.4
    • /
    • pp.433-437
    • /
    • 2013
  • Electrical discharge plasma created in a multi-channel porous ceramic membrane-supported catalyst was applied to the decomposition of a volatile organic compound (VOC). For the purpose of improving the oxidation capability, the ceramic membrane used as a low-pressure drop catalyst support was loaded with zinc oxide photocatalyst by the incipient wetness impregnation method. Alternating current-driven discharge plasma was created inside the porous ceramic membrane to produce reactive species such as radicals, ozone, ions and excited molecules available for the decomposition of VOC. As the voltage supplied to the reactor increased, the plasma discharge gradually propagated in the radial direction, creating an uniform plasma in the entire ceramic membrane above a certain voltage. Ethylene was used as a model VOC. The ethylene decomposition efficiency was examined with experimental variables such as the specific energy density, inlet ethylene concentration and zinc oxide loading. When compared at the identical energy density, the decomposition efficiency obtained with the zinc oxide-loaded ceramic membrane was substantially higher than that of the bare membrane case. Both nitrogen and oxygen played an important role in initiating the decomposition of ethylene. The rate of the decomposition is governed by the quantity of reactive species generated by the plasma, and a strong dependence of the decomposition efficiency on the initial concentration was observed.

The Evaluation of Recovery Rate of Radioimmunoassay Using Certified Reference Material (CRM) (인증표준물질(CRM)을 이용한 방사면역측정법의 회수율 평가)

  • Choi, Sung Hee;Shin, Sun Young;Lim, So Hee;Hong, Mee Kyung;Noh, Gyeong Woon;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.158-162
    • /
    • 2014
  • Purpose: Reference material (RM) is defined as material that is safe and homogeneous enough about specified characteristic that is made with a purpose of using test of measurement or nominal characteristic. Certified reference material (CRM), which is issued by authorized organization, is defined as reference material that provides characteristic value, link uncertainty and retroactivity. The purpose of this paper was to evaluate recovery of radioimmunoassay by Certified Reference Material enclosed with a certificate and therefore to enhance reliability of test. Materials and Methods: WHO certified reference material is purchased from NIBSC (National Institute for Biological Standard and Control, United Kingdom) and made of 3 levels that are C-1 (low concentration), C-2 (medium concentration) and C-3 (high concentration) and measured for kit at the Seoul National University Hospital. Recovery rate is evaluated after measurement at four different days. Results: Recovery rate results using WHO certified reference material are T4 90%, Ferritin 88%, PSA 94%, Prolactin 99%, AFP 94% and TSH 93%. Conclusion: A procedure that appropriate accuracy, precision, specificity, sensitivity, reproducibility, and validate on the subject of kit for radioimmunoassay is essential. Recovery rate assay as extraction efficiency of analysis process is percent about already measuring results of analysis result after all measuring process. This is very important assessment standards of performance evaluation of immunoassay kit. Recovery rate results of 6 type used WHO CRM are satisfactory to 88~99%. This demonstrates that the radioimmunoassay is a very accurate measurement, which is very effectively utilized in clinical practice.

  • PDF

A Study on the Precise End-Point Detection in Titration by Using the Phase Angle Measurements (위상각 측정에 의한 적정의 정확한 종말점 검출법에 관한 연구)

  • Park, Byung-Bin;Shin, Ho-Sang;Lee, Han-Hyoung
    • Analytical Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.290-298
    • /
    • 1999
  • A study on the application of impedance phase angle for redox titration, acid-base titration, chelate titration and precipitation titration has been carried out. A constant alternating current was passed between two platinum electrodes. One of them was a polarizable micro-electrode of $0.1cm^2$ or $0.026cm^2$ surface area and the other a non-polarizable large electrode of $1cm^2$ surface area dipped in the solution to be titrated. The impedance and the phase angle of the titration cell were measured with lock-in amplifier to obtain well behaved titration curve respectively. In titration of oxalic acid vs. potassium permanganate, the end-point was obtained successfully from the phase angle titration curve. In this experiment, the concentration of 0.0005 M to 0.05 M, the current of $50{\mu}A$ and the frequency of near 50 Hz were used. In titration of phosphoric acid vs. sodium hydroxide, the first end-point was obtained successfully on the optimum experimental condition of 0.001 M concentration, $50{\mu}A$ current and 25~97 Hz frequency. However, the end-point in titration of cupric sulfate vs. disodium-EDTA couldn't be obtained clearly. The end-point was obtained with the out-of-phase impedance curve on the experimental condition of 0.01 M concentration, $100{\mu}A$ current, 5~35 Hz frequency range. In titration of sodium chloride vs. silver nitrate, the end-point was obtained successfully on the experimental condition of 0.1 M concentration, $100{\mu}A$ current and 5~47 Hz frequency range. This study showed that the impedance phase angle was applicable for the detection of the end-points in redox titration curve, acid-base titration curve, chelate titration curve and precipitation titration curve.

  • PDF

Characteristics of Electrode Potential and AC Impendance of Perchlorate Ion-Selective Electrodes Based on Quaternary Phosphonium Salts in PVC Membranes (제4급 인산염을 이용한 과염소산 이온선택성 PVC막 전극의 전극전위와 AC 임피던스 특성)

  • 안형환
    • Membrane Journal
    • /
    • v.9 no.4
    • /
    • pp.230-239
    • /
    • 1999
  • Perchlorate ion-selective electrodes in PVC membranes that respond linearly to concentration 106 M were developed by incorporating the quaternary phosphonium salts as a canier. The effects of the chemical structure, the contents of canier, the kind of plasticizer and the membrane thickness on electrode characteristics such as the electrode slope, the linear respone range and the detection limit were studied. With this results, the detectable pH range, selectivity coefficients and AC impedance characteristics were compared and investigated. The perchlorate ion substituents of the quaternary phosphonium salts like tetraoctylphosphonium perchlorate (TOPP) , tetraphenylphosphonium perchlorate(TPPP), and tetrabutylphosphonium perchlorate(TBPP) as a canier were used. The electrode characteristics were better in the ascending order of TBPP < TPPP < TOPP, with the increase of carbon chain length of the alkyl group. Dioctylsebacate(OOS) was best as a plasticizer, the canier contents were better with 11.76 wt% and the optimum membrane thickness was 0.19 mm. Under the above condition, the electrode slope was 56.58 mV/$^P{ClO}_4$,the linear response range was $10^{-1}$\times$10^{-6}$ M, the detection limit was 9.66 x $10^{-7}$ M. The performance of electrode was better than Orion electrode. The electrode potential was stable within the pH range from 3 to 11. The order of the selectivity coefficients for the perchlorate ion was sol < F < Br < 1. With the result of impedance spectrum, it was found that the equivalent circuit for the electrode could be expressed by a series combination of solution resistance, parallel circuit consisting of the double layer capacitance and bulk resistance and Warburg impedance. And solution resistance was almost not appeared and Warburg impedance was highly appeared by diffusion. Then Warburg coefficient was 1.32$\times$$10^74 $\Omega$ $\cdot$ ${cm}^2/s^{1/2}$.

  • PDF

Microbiological Study on the Preservation of Marine Environments I. Distribution of vitamin $B_{12}$, thiamine and biotin in the sea water of Kunsan (해양환경보전에 있어서의 미생물학적 연구 I. 군산 앞바다에 있어서의 Vitamin $B_{12}$, Thiamine 및 Biotin의 분포)

  • Kim Jong Myeon;Cho In Ho;Park Chung Ung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.16 no.1
    • /
    • pp.25-30
    • /
    • 1983
  • The concentrations of dissolved vitamin $B_{12}$, thiamine and biotin in the water of Gyokpo coast, were determined by microbiological assay methods. Also the relations between the distribution of B group vitamin and other environmental factors were studied. Vitamin $B_{12}$ was assayed with Euglena gracilis strain Z, thiamine with Cryptococous albidus and biotin with Achromo bacter sp. yH-51. It was found that the concentration of B group vitamin in the water of Gyokpo coast were normal level : vitamin $B_{12}$; 1.36-3.95 ng/l, thiamine ; u-0.4 ng/l and biotin; 1.40-14.60 ng/l. The concentration of B group vitamin was high in summer than in winter. In the water of Gyokpo coast during summer, B group vitamin occurred slightly lower level than normal, the concentration suficiently neccessary for phytoplankton development. The concentration of biotin was positively correlated with abundance of phytoplankton, but not aerobic heterotrophic bacteria. It was suggested that the concentration of biotin in water might be much more influenced with the growth of phytoplankton and any environmental factors than bacteria and the other vitamin, especially.

  • PDF

Treatment of Liquid Waste Containing Highly Concentrated Ethylenediaminetetraaceticacid by Using Underwater Electrical Discharge (수중 전기방전을 이용한 에틸렌디아민테트라아세트산 폐액의 처리)

  • Jo, Jin-Oh;Mok, Young-Sun;Kang, Duk-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.5
    • /
    • pp.564-570
    • /
    • 2007
  • This study investigated the treatment of liquid waste containing highly concentrated iron(III)-ethylenediaminetetraaceticacid (Fe(III)-EDTA) of 70,000 mg/L by an underwater electrical discharge process using low voltage and high current. When AC voltage is applied to the discharging electrode with the other electrode grounded, the temperature of the liquid waste around the discharging electrode rapidly increases, and at the same time, hydrogen and oxygen gases are formed at the electrode as a result of electrochemical reactions. Ultimately, gases formed by vaporization of water and electrochemical reactions cover the electrode. Since the liquid waste is electrically conductive, it elongates the ground electrode up to the border of the gas layer, where electrical discharge occurs. Without hydrogen peroxide, electrical discharge was able to remove about 50% of Fe(III)-EDTA. As the concentration of hydrogen peroxide added increased, the removal efficiency of Fe(III)-EDTA increased. When the molar ratio of hydrogen peroxide to the initial Fe(III)-EDTA was higher than 24.7, more than 80 g of Fe(III)-EDTA was removed with an energy of 1 kWh. A comparison between tungsten and steel electrodes showed that electrode material did not affect the Fe(III)-EDTA removal. In the present underwater electrical discharge process, the removal of Fe(III)-EDTA was completed within 30 min at molar ratios of hydrogen peroxide to the initial Fe(III)-EDTA higher than 24.7.