• Title/Summary/Keyword: 논문평가

검색결과 33,988건 처리시간 0.067초

A Study on the Distinct Element Modelling of Jointed Rock Masses Considering Geometrical and Mechanical Properties of Joints (절리의 기하학적 특성과 역학적 특성을 고려한 절리암반의 개별요소모델링에 관한 연구)

  • Jang, Seok-Bu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 한국지반공학회 1998년도 터널.암반역학위원회 박사학위 논문집
    • /
    • pp.35-81
    • /
    • 1998
  • Distinct Element Method(DEM) has a great advantage to model the discontinuous behaviour of jointed rock masses such as rotation, sliding, and separation of rock blocks. Geometrical data of joints by a field monitoring is not enough to model the jointed rock mass though the results of DE analysis for the jointed rock mass is most sensitive to the distributional properties of joints. Also, it is important to use a properly joint law in evaluating the stability of a jointed rock mass because the joint is considered as the contact between blocks in DEM. In this study, a stochastic modelling technique is developed and the dilatant rock joint is numerically modelled in order to consider th geometrical and mechanical properties of joints in DE analysis. The stochastic modelling technique provides a assemblage of rock blocks by reproducing the joint distribution from insufficient joint data. Numerical Modelling of joint dilatancy in a edge-edge contact of DEM enable to consider not only mechanical properties but also various boundary conditions of joint. Preprocess Procedure for a stochastic DE model is composed of a statistical process of raw data of joints, a joint generation, and a block boundary generation. This stochastic DE model is used to analyze the effect of deviations of geometrical joint parameters on .the behaviour of jointed rock masses. This modelling method may be one tool for the consistency of DE analysis because it keeps the objectivity of the numerical model. In the joint constitutive law with a dilatancy, the normal and shear behaviour of a joint are fully coupled due to dilatation. It is easy to quantify the input Parameters used in the joint law from laboratory tests. The boundary effect on the behaviour of a joint is verified from shear tests under CNL and CNS using the numerical model of a single joint. The numerical model developed is applied to jointed rock masses to evaluate the effect of joint dilation on tunnel stability.

  • PDF

Influence of the Increase of Dissolved $CO_2$ Concentration on the Marine Organisms and Ecosystems (해수중 용존 $CO_2$ 농도 증가가 해양생물 및 해양생태계에 미치는 영향: 국내외 사례 연구)

  • Lee, Jung-Suk;Lee, Kyu-Tae;Kim, Chan-Kook;Park, Gun-Ho;Lee, Jong-Hyeon;Park, Young-Gyu;Gang, Seong-Gil
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • 제9권4호
    • /
    • pp.243-252
    • /
    • 2006
  • Influence of the increasing carbon dioxide concentration in seawater on various marine organisms is assessed in this article with regard to the impacts of anthropogenic $CO_2$ introduced into surface or deep oceans. Recent proposals to sequester $CO_2$ in deep oceans arouse the concerns of adverse effects of increased $CO_2$ concentration on deep-sea organisms. Atmospheric introduction of $CO_2$ into the ocean can also acidify the surface water, thereby the population of some sensitive organisms including coral reefs, cocolithophorids and sea urchins will be reduced considerably in near future (e.g. in 2100 unless the increasing trend of $CO_2$ emission is actively regulated). We exposed bioluminescent bacteria and benthic amphipods to varying concentrations of $CO_2$ and also pH for a short period. The ${\sim}l.5$ unit decrease of pH adversely affected test organisms. However, amphipods were not influenced by decreasing pH when HCl was used for the seawater acidification. In this article, we reviewed the biological adverse effects of $CO_2$ on various marine organisms studied so for. Theses results will be useful to predict the potential risks of the increase of $CO_2$ concentrations in seawater due to the increase of atmospheric $CO_2$ emission and/or sequestration of $CO_2$ in deep oceans.

  • PDF

Simple Formulae for Buckling and Ultimate Strength Estimation of Plates Subjected to Water Pressure and Uniaxial Compression (수압(水壓)과 압축력(壓縮力)을 받는 평판(平板)의 좌굴(挫屈) 및 최종강도(最終强度) 추정식(推定式))

  • Jeom-K.,Paik;Chang-Y.,Kim
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • 제25권4호
    • /
    • pp.69-80
    • /
    • 1988
  • This paper proposes simple formulae for buckling and ultimate strength estimation of plates subjected to water pressure and uniaxial compression. For the construction of a formula for elastic buckling strength estimation, parametric study for actual ship plates with varying aspect ratios and the magnitude of water pressure is carried out by means of principle of minimum potential energy. Based on the results by parametric study, a new formula is approximately expressed as a continuous function of loads and aspect ratio. On the other hand, in order to get a formula for ultimate strength estimation, in-plane stress distribution of plates is investigated through large deflection analysis and total in-plane stresses are expressed as an explicit form. By applying Mises's plasticity condition, ultimate strength criterion is then derives. In the case of plates under relatively small water pressure, the results by the proposed formulae are in good agreement compared with those by other methods and experiment. But present formula overestimates the ultimate strength in the range of large water pressure. However, actual ship plates are subjected to relatively small water pressure except for the impact load due to slamming etc.. Therefore, it is considered that present formulae can be applied for the practical use.

  • PDF

Effect of Package Size and Pasteurization Temperature on the Quality of Sous Vide Processed Spinach (Sous Vide 가공 시금치의 품질에 미치는 포장단위 및 살균온도의 영향)

  • 장재덕;김기태;이동선
    • Food Science and Preservation
    • /
    • 제11권2호
    • /
    • pp.195-200
    • /
    • 2004
  • Microbial lethal value and nutrient retention of sous vide processed spinach were evaluated with mathematical model prediction and experimental trial for different package sizes and pasteurization temperatures. The package size covers 500 g, 1 kg and 2 kg, while the pasteurization temperature includes 80, 90 and 97$^{\circ}C$. The basic process scheme consists of filling blanched spinach into barrier plastic film pouch, sealing under vacuum, pasteurization in hot water with over pressure and final cooling to 3$^{\circ}C$. Pasteurization condition was designed based on attainment of 6 decimal inactivation of Listeria monocytogenes at geometric center of the pouch package by heating cycle, which was determined by general method. Heat penetration property of the package and thermal destruction kinetics were combined to estimate the retention of ascorbic acid and chlorophyll. Smaller packages with shorter pasteurization time gave better nutrient retention, physical and chemical qualities. Larger package size was estimated and confirmed experimentally to give higher pasteurization value at center, lower ascorbic acid and chlorophyll contents caused by longer heat process time. Lower pasteurization temperature with longer process time was predicted to give lower pasteurization value at center and lower ascorbic acid, while chlorophyll content was affected little by the temperature. Experimental trial showed better retention of ascorbic acid and chlorophyll for smaller package and higher pasteurization temperature with shorter heating time. The beneficial effect of smaller package and higher pasteurization temperature was also observed in texture, color retention and drip production.

Evaluation of Organ and Effective Dose using A PC-Based Monte Carlo Program in AEC Mode and Fix Mode for the whole spine antero-posterior radiography (전 척추 전.후 방향 검사 시 AEC Mode와 Fix Mode에서 PC-Based Monte Carlo Program을 이용한 장기선량 및 유효선량 평가)

  • Kim, Jeong Jin;Jang, Seong Won;Park, Jang Heum;Lee, Kwan Seob;Ha, Dong Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • 제14권2호
    • /
    • pp.23-31
    • /
    • 2012
  • There are AEC mode and fix mode to exposure when the whole spine antero-posterior radiography is done by using DR equipment. This study compared the utility of fix mode to AEC mode, by evaluating organ dose and effective dose and by examining the quality of radiographic image. GE DEFINIUM 8000 and ART-200X Rando Phantom manufactured by Flukebiometical were used for this study. The Rando phantom was set in front of wall detector of X-rays equipment. AEC mode was set at 80kVp and Fix mode was set at 80kVp, 25mAs, 32mAs, 40mAs, and 50mAs. Whole spine AP image were aquired by combining C, T-L and L-S spine images obtained through 3 exposures. When obtaining C, T-L and L-S spine images, were checked for Air kerma (mGy) value calculated by UNFORS Xi meter attached at the phantom surface of center of radiation field. The effective and organ doses were compared by PCXMC program (PC-Based Monte Carlo Program). The quality of obtained radiographic image was evaluated visually by 3 radiologists using resolution chart. When the effective doses was calculated based on tissue weighting factor of ICRP-103, 1.278mSv was measured by AEC mode, and Fix mode measured 0.405mSv at 25mAs, 0.518mSv at 32mAs, 0.649mSv at 40mAs, and 0.810mSv at 50mAS. In addition, the organ dose measured with esposure at 25mAs by Fix mode was almost equivalent to the organ dose by AEC mode, at the esophagus, thyroid, oral mucosa, salivaly glands located at the cervical spine part, while the organ dose by Fix mode was in general lower than the organ dose by AEC mode at the other organs. When Fix mode at 32mAs, 40mAs, and 50mAs was compared to AEC mode for organ dose in 26 organs, AEC mode had higher measurement in 21 organs but not for than brain, trachea, thyroid, oral mucosa, and salivaly glands which are located at the cervical spine part. The image quality evaluated by resolution test chart was much higher with AEC mode than the quality with Fix mode at all exposure conditions. However, while the image quality of cervical spine exposured at 50mAs by Fix mode was lower than the quality of AEC mode, thoraco-lumbar spine and lumbo-sacral spine were calculated and the quality was similar to AEC mode. Scoliosis occurs mainly at thoraco-lumbar and lumbo-sacral spine, not at cervical spine. Compared to AEC mode, Using the appropriate protocol (80kVp, 50mAs) of fix mode for whole spine AP radiography was thought to be useful because the image quality of the thoraco-lumar and lumbo-sacral spine was similar on AEC mode, Also organ and effective doses can be decreased with Fix mode. Therefore, It is considered that fix mode can be used properly with AEC mode for whole spine AP radiography when considering patient's body posture.

  • PDF

Dynamic Traffic Assignment Using Genetic Algorithm (유전자 알고리즘을 이용한 동적통행배정에 관한 연구)

  • Park, Kyung-Chul;Park, Chang-Ho;Chon, Kyung-Soo;Rhee, Sung-Mo
    • Journal of Korean Society for Geospatial Information Science
    • /
    • 제8권1호
    • /
    • pp.51-63
    • /
    • 2000
  • Dynamic traffic assignment(DTA) has been a topic of substantial research during the past decade. While DTA is gradually maturing, many aspects of DTA still need improvement, especially regarding its formulation and solution algerian Recently, with its promise for In(Intelligent Transportation System) and GIS(Geographic Information System) applications, DTA have received increasing attention. This potential also implies higher requirement for DTA modeling, especially regarding its solution efficiency for real-time implementation. But DTA have many mathematical difficulties in searching process due to the complexity of spatial and temporal variables. Although many solution algorithms have been studied, conventional methods cannot iud the solution in case that objective function or constraints is not convex. In this paper, the genetic algorithm to find the solution of DTA is applied and the Merchant-Nemhauser model is used as DTA model because it has a nonconvex constraint set. To handle the nonconvex constraint set the GENOCOP III system which is a kind of the genetic algorithm is used in this study. Results for the sample network have been compared with the results of conventional method.

  • PDF

The Difference of the Cleaning and Wettability-maintaining Efficacy of Lens Care Solution to RGP Lens (관리 용품에 따른 RGP 렌즈의 세척효과 및 습윤성 차이)

  • Kim, Myoung-Hea;Park, Mi-Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • 제11권1호
    • /
    • pp.27-34
    • /
    • 2006
  • We investigated the question whether the efficacy of cleaning tear components on RGP lens and preserving the superior wettability of RGP lens depended on the different type of contact lens care system - RGP lens care solution, SCL care solution, combined solution both for SCL and RGP lens or saline solution. The removal efficacy of the deposited protein was examined by Lowry protein assay and Scanning Electro Microscope(SEM) and residual lipid concentration on RGP lens was determined by High Pressure Liquid Chromatology(HPLC). Wettability was assessed with an equilibrium water-in-air contact angle method. When cared by RGP lens solution, it was demonstrated that 62 percent out of the adhered protein on RGP lens were removed and the removal efficacy of RGP lens solution was not only 4 times than saline solution and the alternative but also higher twice than SCL solution. Contrarily, the SCL solution had the most excellent removal efficacy of the adhered protein on SCL. These results suggest that the cleaning efficacy is thought to be affected by the other factors like the viscosity of care solutions, which mutual contact between RGP lens and care solutions is on the increase due to the viscosity enhancer in RGP lens care solution. RGP lens solution had the greatest removing efficacy to cholesterol and the residual cholesterol concentration was decreased to 50%. It is significant for RGP lens to preserve the superior wettability which means the predictive value for comfortable wearing and it showed that the RGP lens solution offered the most excellent efficacy to maintain the surface wettability. Combined solution both for SCL and RGP lens had weak efficacy of cleaning and maintaining wettability for RGP lens compared to RGP lens care solution.

  • PDF

A Study on the Locational Decision Factors of Discount Stores : The Case of Cheonan (종합슈퍼마켓의 입지 결정 요인에 관한 연구 : 천안상권을 중심으로)

  • So, Jang-Hoon;Hwang, Hee-Joong
    • Journal of Distribution Science
    • /
    • 제10권5호
    • /
    • pp.37-44
    • /
    • 2012
  • In this paper, we investigate several factors that affect the locational decision of discount stores by using previous studies on the marketing area and the location of commercial facilities. We selected 21 primary variables that are expected to influence the decision of store location and, by factor analysis, grouped them into five underlying factors. Among these, the demographic factor, which shows the potential purchasing power level, had the greatest impact on the locational decision for the store. However, we found individual stores positioned according to unique locational characteristics in addition to the demographic factor. It means that we have to additionally consider if the vicinity of the market is based on any physical properties. Many previous studies proposed four decision factors for store location: the economic factor, the demographic factor, the land utilization factor, and traffic factor. However, the fivefold factors-our distinctive contribution-are more concrete and persuasive according to Korean reality. We show that location preference is based on the following criteria: (1) the area is densely populated, (2) houses stand close together, (3) residents have a high income level, (4) road traffic is developed and easy to access, and (5) public transportation is well developed. The demographic factor has the greatest impact on the location of a discount store. The number of households has a greater relevance to the demographic factor than does the individual consumer. Second, discount stores relatively prefer places where houses are located close together because such places offer easy access to the market. Third, a place whose residents have a high income level will be preferred, with its large cars and excellent traffic conditions. Fourth, a location would be highly rated if the roads around commercial facilities are well developed and their accessibility is good. Finally, discount stores must be located close to bus stops because female consumers, including housewives-the most important customers-evaluate stores based on distance. In this research, the variable of consumer attitude and preference was excluded, and the location factors of discount stores were analyzed according to a microscopic view through physical spatial data. In the future, the opening of new discount stores based on the five factors indicated above will require a comparatively shorter time from the first project feasibility analysis. In addition, the result of our study can be applied to the field of public policy for constructing and attracting large-scale distribution facilities.

  • PDF

Evaluating Impact Resistance of Externally Strengthened Steel Fiber Reinforced Concrete Slab with Fiber Reinforced Polymers (섬유 보강재로 외부 보강된 강섬유 보강 콘크리트 슬래브의 충격저항성능 평가)

  • Yoo, Doo-Yeol;Min, Kyung-Hwan;Lee, Jin-Young;Yoon, Young-Soo
    • Journal of the Korea Concrete Institute
    • /
    • 제24권3호
    • /
    • pp.293-303
    • /
    • 2012
  • Recently, as construction technology improved, concrete structures not only became larger, taller and longer but were able to perform various functions. However, if extreme loads such as impact, blast, and fire are applied to those structures, it would cause severe property damages and human casualties. Especially, the structural responses from extreme loading are totally different than that from quasi-static loading, because large pressure is applied to structures from mass acceleration effect of impact and blast loads. Therefore, the strain rate effect and damage levels should be considered when concrete structure is designed. In this study, the low velocity impact loading test of steel fiber reinforced concrete (SFRC) slabs including 0%~1.5% (by volume) of steel fibers, and strengthened with two types of FRP sheets was performed to develop an impact resistant structural member. From the test results, the maximum impact load, dissipated energy and the number of drop to failure increased, whereas the maximum displacement and support rotation were reduced by strengthening SFRC slab with FRP sheets in tensile zone. The test results showed that the impact resistance of concrete slab can be substantially improved by externally strengthening using FRP sheets. This result can be used in designing of primary facilities exposed to such extreme loads. The dynamic responses of SFRC slab strengthened with FRP sheets under low velocity impact load were also analyzed using LS-DYNA, a finite element analysis program with an explicit time integration scheme. The comparison of test and analytical results showed that they were within 5% of error with respect to maximum displacements.

Studies of Short-Term Variability of Methane in the Moo-Ahn Observatory Site in Korea (무안지역 메탄가스의 단주기적 농도변화에 대한 평가)

  • Choi, Gyoo-Hoon;Youn, Yong-Hoon;Kim, Chang-Hee;Cho, Young-Min;Kim, Ki-Hyeon
    • Journal of the Korean earth science society
    • /
    • 제22권4호
    • /
    • pp.327-338
    • /
    • 2001
  • In this study, the short-term variability of methane concentrations were investigated over 24-hr scale. The data obtained form the Moo-Ahn (MAN) station located in the western coastal area of Korea were analyzed from various respects to describe its distribution characteristics over short term scale. The MAN data were compared with those obtained from the two major background observatory sites: Point Barrow (Alaska) and Mauna Loa (Hawaii). The mean concentration of methane for the whole study period, when computed using the daily mean values, was found to be 1898${\pm}$85.3ppb (N=812). The mean values for the two comparable sites were observed to be 1832${\pm}$29.6ppb (N=823) for Point Barrow and 1745${\pm}$14.8ppb (N=818) for Mauna Loa. According to the analysis of frequency distribution. the mode value for the MAN area is found to be 1900ppb, but the mean concentration for Point Barrow and Mauna Loa are shown to have relatively low values of 1850 and 1750ppb, respectively. When examined over diurnal scale, the CH$_4$data for the MAN area exhibit a rather consistent trend; CH$_4$level is low during the daytime (after 6:00 A.M) and rises during the nighttime. The findings of the generally enhanced methane concentration in the MAN station may be explained form various respects. One of the most important reasons is that the MAN area is under the influence of various source processes relative to all the other stations under consideration. The short-term distribution patterns for the MAN station are hence characterized not only by the high methane concentration but also by the high oscillation in its CH$_4$concentration level.

  • PDF