• Title/Summary/Keyword: 노이즈 감소

Search Result 297, Processing Time 0.024 seconds

Dose Distribution and Image Quality in the Gantry Aperture for CT Examinations (전산화단층촬영 검사 시 Gantry Aperture 내의 선량분포와 영상의 질)

  • Cho, Pyong-Kon;Kim, You-Hyun;Choi, Jong-Hak;Lee, Ki-Yeol;Kim, Hyung-Cheol;Kim, Jang-Seob;Shin, Dong-Chul;Lee, Sung-Hyun;Lee, Jun-Hyub;Shin, Gwi-Soon
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.453-460
    • /
    • 2009
  • The purpose of this study was to determine the dose distribution and image quality according to slice thickness and BC(beam collimation) in the gantry aperture. CT scans were performed with a 64-slice MDCT(Brilliance 64, Philips, Cleveland, USA) scanner. To determine the dose distribution according to BC, a ionization chamber was placed at isocenter and 5, 10, 15, 20, 25 and 30 cm positions from the isocenter in the 12, 3, 6 and 9 o'clock directions. The dose distribution for phantom scan was also measured using CT head and body dose phantom with five holes at the center of the phantom and the positions of the 12, 3, 6 and 9 o'clock directions. The image noise measurement for different BCs was performed using an AAPM CT phantom. Water-filled block of the phantom was moved by 5 cm or 10 cm to the 12 o'clock direction, and the image noise was measured at the center of the phantom, and the points of 12, 3, 6 and 9 o'clock direction respectively. Some points were placed beyond the scan field of view (SFOV), so that measurement was not possible at that points. The results are as follows: The CTDIw showed a larger decrease as the source goes farther from the iso-center or the BC became wider. The CTDIw depends on the BC width more than the number of the channel of a detector array. The value of CTDIW decreased with increasing BC, but the value decreased 16.6~31.9% in the head phantom scan in air scan and 51.0~64.5% in the body phantom scan. The value of the noise was 3.9~5.9 in the head and 5.3~7.4 in the body except for BC of $2{\times}0.5\;mm$, regardless of the degree of deviation from the iso-center. When a subject was located within the SFOV, the position did not significantly affect image quality even if the subject was out of the center.

  • PDF

Radiation Dose Reducing Effect during the AEC System in the Chest and Abdomen of the MDCT Scanning (흉부 및 복부에서 AEC 적용에 따른 MDCT의 선량 감소 효과)

  • Lee, Jong-Seok;Kweon, Dae-Cheol;You, Beong-Gyu
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.3
    • /
    • pp.225-231
    • /
    • 2009
  • The purpose of the current study was to compare radiation dose of 64MDCT performed with automatic exposure control (AEC) with manual selection fixed tube current. We evaluated the CT scans of phantom of the chest and abdomen using the fixed tube current and AEC technique. Objective image noise shown as the standard deviation of CT value in Hounsfield units was measured on the obtained images. Compared with fixed tube current, AEC resulted in reduction of the chest and abdomen in the CTDIvol (35.2%, 5.9%) and DLP (49.3%, 3.2%). Compared with manually selected fixed tube current, AEC resulted in reduced radiation dose at MDCT study of chest and abdomen.

A study on the relationship between acoustic modes in tire-wheel guard space and high frequency road noise (타이어-휠가드 공간의 음장모드와 고주파성 로드노이즈의 상관성 연구)

  • Lee, Jong Hyun;Ku, Yo Cheon;Lee, Jin Mo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.4
    • /
    • pp.288-294
    • /
    • 2016
  • The space between tire and wheel guard acts as a path for tire pattern noise transmission. In this study, acoustic phenomenon occurring in the tire-wheel guard space is investigated using acoustic mode analysis and visualization of the sound pressure distribution over the wheel guard surface. We introduced a cavity over the wheel guard surface to reduce the tire pattern noise, where the cavity acts as an acoustic damper. The interior noise was reduced by 2 dB(A), and the noise control measures treated in this study may provide an efficient method to improve interior sound quality without increasing cost and weight at the final stage of the vehicle development.

Microwave Absorbing Properties of Fe-Si-Al Alloy Flaky Powder-Rubber Composites (Fe-Si-Al 합금 분말 · 고무 복합 자성체의 전파 흡수 특성)

  • Lee Kyung-Sub;Yoon Yeo-Choon;Choi Gwang-Bo;Kim Sung-Soo;Lee Jun-Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.2 s.93
    • /
    • pp.228-234
    • /
    • 2005
  • A magnetic composite as noise absorber of quasi-microwave band was developed. The Fe-Si-Al alloy powder were forged by attrition mill to get flaky shape. The magnetic composite sheet was fabricated in which powders are dispersed in polymer and aligned in the direction perpendicular to electromagnetic wave propagation. The permittivity of magnetic composite is increased as forging time increasing, while the permeability is decreased slightly. The maximum attenuation peak of reflection loss is shifted to lower fiequency range as milling time increasing, and the value of maximum attenuation peak is to get smaller gradually. From these result, we could designed a noise absorber sheet (t=1.0 mm) for quasi-microwave band, which is impedance matched at 1.4 GHz with respect to -8.2 dB reflection 1055.

An Estimate of Image Quality and Radiation Doses of Coronary Artery in MDCT Using Prospective and Retrospective ECG Gating Scan Mode (MDCT 관상동맥 조영 검사에서 전향적 동조화 및 후향적 동조화 기법의 화질과 선량 관계)

  • Oh, Jong-Kap
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.315-321
    • /
    • 2011
  • The goal of this study is to reduce patient exposure dose by providing image quality and radiation dose according to inspection methods. Volume Computed Tomography Dose Index(CTDIvol) and Dose Length Product(DLP) of prospective and retrospective ECG gating snapshot segment of Coronary CT angiography(CTA) were measured each snapshot segment methods. CT number, noise, uniformity, and resolution were also measured using phantom under the same condition of coronary CTA. The results showed that CT number, noise, uniformity and resolution are similar to each other. In terms of CTDIvol and DLP, however, measurement dose of prospective ECG gating snapshot segment was lower than the retrospective case by 37.5% and 40.3%. Therefore, it is highly recommended that in the coronary CTA, prospective ECG gating scan mode should be chosen to reduce patient dose.

Pipe Leak Detection System using Wireless Acoustic Sensor Module and Deep Auto-Encoder

  • Yeo, Doyeob;Lee, Giyoung;Lee, Jae-Cheol
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.2
    • /
    • pp.59-66
    • /
    • 2020
  • In this paper, we propose a pipe leak detection system through data collection using low-power wireless acoustic sensor modules and data analysis using deep auto-encoder. Based on the Fourier transform, we propose a low-power wireless acoustic sensor module that reduces data traffic by reducing the amount of acoustic sensor data to about 1/800, and we design the system that is robust to noise generated in the audible frequency band using only 20kHz~100kHz frequency signals. In addition, the proposed system is designed using a deep auto-encoder to accurately detect pipe leaks even with a reduced amount of data. Numerical experiments show that the proposed pipe leak detection system has a high accuracy of 99.94% and Type-II error of 0% even in the environment where high frequency band noise is mixed.

Efficiency of Median Modified Wiener Filter Algorithm for Noise Reduction in PET/MR Images: A Phantom Study (PET/MR 영상에서의 팬텀을 활용한 노이즈 감소를 위한 변형된 중간값 위너필터의 적용 효율성 연구)

  • Cho, Young Hyun;Lee, Se Jeong;Lee, Youngjin;Park, Chan Rok
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.225-229
    • /
    • 2021
  • The digital image such as medical X-ray and nuclear medicine field mainly contains noise distribution. The noise degree in image degrades image quality. That is why, the noise reduction algorithm is efficient for medical image field. In this study, we confirmed effectiveness of application for median modified Wiener filter (MMWF) algorithm for noise reduction in PET/MR image compared with median filter image, which is used as conventional noise redcution algorithm. The Jaszczak PET phantom was used by using 18F solution and filled with NaCl+NiSO4 fluids. In addition, the radioactivity ratio between background and six spheres in the phantom is maintained to 1:8. In order to mimic noise distribution in the image, we applied Gaussian noise using MATLAB software. To evlauate image quality, the contrast to noise ratio (CNR) and coefficient of variation (COV) were used. According to the results, compared with noise image and images with MMWF algorithm, the image with MMWF algorithm is increased approximately 33.2% for CNR result, decreased approximately 79.3% for COV result. In conclusion, we proved usefulness of MMWF algorithm in the PET/MR images.

Improvement of SOC Estimation based on Noise Parameter Differential Design of Extended Kalman Filter according to Non-linearity of LiFePO4 Battery (LiFePO4 배터리의 비선형성에 따른 확장 칼만 필터 노이즈 파라미터 차등 설계 기반 SOC 추정 향상 기법)

  • Park, Jinhyeong;Kim, Jaeho;Jang, Min-Ho;Jang, Sung-Soo;Kim, Jonghoon
    • Proceedings of the KIPE Conference
    • /
    • 2018.11a
    • /
    • pp.121-122
    • /
    • 2018
  • 리튬 인산철(LFP, $LiFePo_4$) 배터리의 경우 다른 종류의 배터리에 비해 내부 파라미터가 비선형적인 단점이 있다. 일반적인 배터리 등가회로 모델을 적용 시, 비선형성으로 인해 추정 성능이 감소한다. 배터리 등가회로 모델을 기반인 확장 칼만 필터(EKF, Extended Kalman Filter)를 통해 SOC (State of Charge) 추정 시 추정성능이 감소할 수 있다. 따라서 본 논문은 LFP 배터리의 SOC 추정 성능 향상을 위해 실시간 파라미터 관측기를 통한 배터리 등가회로 모델을 기반으로 EKF의 내부 파라미터를 분석하고 이에 따른 차등 모델을 제안한다.

  • PDF

Edge Detection System for Noisy Video Sequences Using Partial Reconfiguration (부분 재구성을 이용한 노이즈 영상의 경계선 검출 시스템)

  • Yoon, Il-Jung;Joung, Hee-Won;Kim, Seung-Jong;Min, Byong-Seok;Lee, Joo-Heung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.21-31
    • /
    • 2017
  • In this paper, the Zynq system-on-chip (SoC) platform is used to design an adaptive noise reduction and edge-detection system using partial reconfiguration. Filters are implemented in a partially reconfigurable (PR) region to provide high computational complexity in real-time, 1080p video processing. In addition, partial reconfiguration enables better utilization of hardware resources in the embedded system from autonomous replacement of filters in the same PR region. The proposed edge-detection system performs adaptive noise reduction if the noise density level in the incoming video sequences exceeds a given threshold value. Results of implementation show that the proposed system improves the accuracy of edge-detection results (14~20 times in Pratt's Figure of Merit) through self-reconfiguration of filter bitstreams triggered by noise density level in the video sequences. In addition, the ZyCAP controller implemented in this paper enables about 2.1 times faster reconfiguration when compared to a PCAP controller.

Degradation Evaluation of 1Cr-0.5Mo Steel using Barkhausen Noise (바크하우젠 노이즈에 의한 1Cr-0.5Mo 강의 열화도 평가)

  • Kim, Min-Gi;Park, Jong-Seo;Lee, Yun-Hee;Kim, Cheol-Gi;Ryu, Kwon-Sang
    • Journal of the Korean Magnetics Society
    • /
    • v.21 no.4
    • /
    • pp.136-140
    • /
    • 2011
  • Mechanical properties of degraded materials must be measured for evaluating the integrity of the facilities operating at high temperature. In fact it is complicated to obtain the different degraded specimens from an operating facility. Specimens of 1Cr-0.5Mo steel prepared by the isothermal heat treatment at $700^{\circ}C$ were tested, which has been widely used as tubes for heat exchangers and as plates for pressure vessels. The magnetic properties and Rockwell hardness (HRB) were measured at room temperature. The peak interval of Barkhausen noise envelope (PIBNE), coercivity, and hardness decreased with the increase of degradation. The magnetic and mechanical softening of matrix is likely to govern the properties of the specimen more than the hardening of grain boundary by carbide precipitations. The degradation of test material may be determined by the linear correlation of PIBNE and HRB. Degradation of 1Cr-0.5Mo steel could well be nondestructively evaluated by PIBNE measured with surface type probe.