• 제목/요약/키워드: 냉.난방

검색결과 154건 처리시간 0.031초

HadCM3를 이용한 서울 및 울산지역의 미래 냉.난방도일 예측 (The expectation of future cooling and heating degree day of the Seoul and Ulsan using HadCM3)

  • 이관호;유호천;노경환
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.160-165
    • /
    • 2008
  • The concern in energy reduction in the field of architecture which takes up a big weight in domestic energy consumption is gradually increasing. For this reason, a lot of research work on this matter is being carried out. Particularly, it is generally required that currently used system in a structure for energy reduction should be maximized in its efficiency. In addition, research on several energy reduction typed systems is underway. Such a research work should not only include the one in time of the present but also keep up with the trend for future-oriented research. This research paper forecasted and analyzed the trend for global warming and demand of a structure for energy in the future by applying climate scenarios to cooling degree-day and heating degree-day. Also, this research found out the decrease in heating degree-days and increase in cooling degree-days until this moment due to the progress of global warming. In addition, as for heating degree-days in the future forecasted on the basis of HadCM3, it is estimated that the range of decrease could be ever bigger starting 2040 in case of Seoul and also starting 2010 in case of Ulsan ever after respectively. In case of cooling degree-days, it is estimated that its increase range could be bigger abruptly starting 2050, and after 2080, its increase range would be much bigger.

  • PDF

전동차 출입문에 에어커튼 설치시 객실 온도 변화 연구 (The Study on the Effect of Passenger Coach temperature When Aircurtains Installed At Electrical Rolling Stock At Entrance Door)

  • 안종곤;김철호;박덕신
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.489-496
    • /
    • 2004
  • 전동차 출입문에 에어 커튼을 설치시 객실의 냉난방 효과에는 외부의 찬공기나 더운 공기를 차단하고 외부로부터의 먼지, 배기가스, 냄새, 연기 등의 침입을 방지함으로 위생에 좋으며 항상 쾌적하고 깨끗한 실내를 유지하며, 객실내의 온도 분포가 균일함으로써 건강에도 도움이 된다 냉방시의 냉기 난방시의 온기, 손실을 줄여 냉. 난방 유지비를 대폭 절감 할 수 있으며, (약 86$\%$) 설치 전보다 승객의 출입에 쾌적함을 주며 경영주에게는 경비 절감을 위한 필수품이 되며 예산 절감에 효과가 있다. 출입문 부근의 승객에게도 출입문의 개폐시 냉온의 온도 변동이 없어 승객에게 쾌적감을 느끼게 하며, 객실 온도는 출입문을 열거나 닫을 때 온도 차이가 있다. 연구의 주목적은 외풍 문제에 관계없는 만족스러운 열환경 상태를 유지하는데 있으며 전동차 출입문에 에어 커튼을 설치했을 때 온도의 변화 도를 연구하였다. 그리고 온도는 객실 바닥에서 0.1 0.5 1.3 1.7m 높이에서 측정하였으며 온도 병화의 원인은 외풍에 더 많은 영향을 받는다는 것을 발견하였다.

  • PDF

자동차 냉/난방 성능 향상을 위한 공기조화 덕트의 기류해석 (Aerodynamic Analysis of Automotive HVAC Duct for Enhancement of Cooling/Heating Performance)

  • 주재우;이기돈;허만웅;김광용;박준규;윤정환;김홍빈
    • 설비공학논문집
    • /
    • 제24권1호
    • /
    • pp.23-28
    • /
    • 2012
  • In the present work, numerical analyses of air flow in HVAC duct have been carried out for enhancement of cooling/heating performance. For the analyses, three-dimensional Reynolds-averaged Navier-Stokes equations have been solved with the shear stress transport turbulence model. The numerical results were validated in comparison with the experimental data. Based on the numerical results, the HVAC duct was designed to reduce the pressure loss. The modified duct geometry shows largely reduced pressure drop in comparison with the reference geometry. And, through modified duct shape, the performance of air conditioning has been enhanced.

천장 카세트형 냉·난방기에 의해 형성되는 학교 교실의 실내 열환경 및 공기환경의 개선에 대한 연구 (A Study on the Improvement of Indoor Thermal and Air Environment Made by Ceiling Cassette Type Cooling and Heating Unit in Classrooms)

  • 장현재;이하영
    • 한국태양에너지학회 논문집
    • /
    • 제32권6호
    • /
    • pp.141-148
    • /
    • 2012
  • Ceiling cassette type air conditioner has been a main stream as a heating/cooling system recently in school, Korea. In this study, indoor thermal environments made by ceiling cassette type air conditioner were investigated by CFD simulation. Concentrations of $CO_2$ were investigated by a field measurement. Indoor thermal environment with the velocity inlet angle of $45^{\circ}$ from the ceiling in heating season was very ununiform so that thermal area was divided into two parts those the one is window side which is cold, and the other is corridor side which is hot. In cooling season under the same condition, there are areas too hot or too cold. If the velocity inlet angle is set in $30^{\circ}$ from the ceiling, indoor thermal environments was improved greatly in cooling season and heating season, too. Also, from the field measurement of $CO_2$ concentrations, it was suggested to install ventilators with proper air volume considered the number of class students.

전문 ESCO 지정제 평가방안 연구 (A Study on the Evaluation Method for Professional ESCO)

  • 임기추
    • 에너지공학
    • /
    • 제22권2호
    • /
    • pp.90-95
    • /
    • 2013
  • 기술 중심의 ESCO 전문화를 위한 전문 ESCO 지정제 평가기준 마련이 요청되어 왔다. 이에, 본 연구는 전문 ESCO 지정제도에 관한 평가기준을 설정하기 위해 5가지 목적을 전제하였다. 즉, 에너지 절감의 우수성, 경영지표의 건전성, 고객만족도, 원천기술 보유업체의 참여 유도, 절약성과 보증계약 중시 등이다. 이를 바탕으로 전문가 자문을 통해 전문 ESCO 지정을 위한 평가배점(안)을 전문성(40점), 경영상태(15점), 고객만족도(20점), 기술능력(25점) 등 평가지표로 구성하고, 각각 세부 평가항목의 선정 및 배점기준을 설정하였다. ESCO 업계 설문조사를 통해 비교적 높은 동의율을 보였다. 전문 ESCO 지정제도의 적용 시 기업규모를 중소기업으로 한정하고 적용기술 대상을 조명, 열병합발전, 공정개선, 폐열회수, 냉 난방설비 등 5개의 특정 기술분야로 지정하는 것이 가능할 것이다.

지열원 열펌프 시스템의 냉${\cdot}$난방 성능 평가 (Cooling and Heating Performance Evaluation of a GSHP System)

  • 손병후;조정식;신현준;안형준
    • 설비공학논문집
    • /
    • 제17권1호
    • /
    • pp.71-81
    • /
    • 2005
  • The main objective of the present study is to investigate the performance characteristics of a ground-source heat pump(GSHP) system with a 130 m vertical and 62 mm nominal diameter U-tube ground heat exchanger. In order to evaluate the performance analysis, the ground-source heat pump connected to a test room with $90\;m^2$ floor area in the Korea Institute of Construction $Technology(37^{\circ}39'N,\;126^{\circ}48'E)$ was designed and constructed. This ground-source heat pump system mainly consisted of ground heat exchanger, indoor heat pumps and measuring devices. The cooling and heating loads of the test room were 5.5 and 7.2 kW at design conditions, respectively. The experimental results were obtained from July 2, 2003 to July 1, 2004. The cooling and heating performance coefficients of the system were determined from the measured data. The average cooling and heating COPs for the system were obtained to be 4.90 and 3.96, respectively. The temperature variations in ground and the ground heat exchanger pipe surface at different depths were also measured.

냉.난방 및 조명에너지를 통합 고려한 DSSC BIPV창호의 사무소건물 적용 효과 연구 (A Study on the Application Effect of DSSC BIPV Window System in Office Building Considering Cooling.Heating.Lighting Energy)

  • 심세라;윤종호;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제31권3호
    • /
    • pp.67-72
    • /
    • 2011
  • The aim of this study is to evaluate how much would the building energy consumption be saved by applying DSSC BIPV window which is possible to control the transmittance and express the color in the office building. For this, physical characteristics such as transmittance and reflectance, U-factor of DSSC areanalyzed and an annual energy consumption that is connected to dimming control is calculated when DSSC BIPV window is applied by alternate clear window system. As a result, It is possible to reduce the anannual energy consumption as much as4.1% by just change the clear double window system to DSSC BIPV double window system because the major factor to reduce energy consumption in the office that has much cooling load than other building is SHGC. When the thermal insulation properties of DSSC BIPV window with low-e coating and making triple window are improved, energy saving ratio is about 9%. Plus, energy saving ratio of 25~28% in lighting energy consumption is possible when the dimming control system with DSSC BIPV window is adopt.

편의성을 고려한 HEMS 전기온수기 최적스케줄링에 관한 연구 (Optimal Scheduling of Electric Water Heater Considering User Comfort For HEMS)

  • 이현승;신제석;오도은;이정일;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.501-502
    • /
    • 2015
  • 매년 증가되는 전력소비량에 대응하여 스마트그리드 기술을 기반으로 수용가 측의 에너지관리 중요성이 부각되고 있으며, 홈 에너지관리시스템(HEMS, Home Energy Management System)은 전기요금 절감과 효율적인 전력소비의 중요한 체계로써 기대되고 있다. 일반적으로, 가정에서 높은 전력소비를 가진 가전제품은 계절성 부하로 전기온수기, 냉/난방기를 일컫는다. 즉, 계절성 부하에 적절한 에너지관리, '최적부하 스케줄링'은 전기요금 절감과 직결되는 것을 의미한다. 본 논문은 Modified Branch-and-Bound 기법을 사용하여 사용자의 편의성을 고려한 전기온수기(EWH, Electric Water Heater)의 스케줄링을 실시하겠다. 여기서 사용자의 편의성이란, 외부의 온도변화 또는 습관에 따라 그 부하를 사용하는 것을 의미한다. 온수사용량, 수온 설정온도 변화의 편의성 제약조건을 고려하여 온수기를 효과적으로 운영하는 스케줄링을 실시한다. 이러한 편의성 내에서 온수기를 운영하며, 작동모드는 3가지(정지, 일반/급속가열) 모드가 존재하며, 다양한 요금제도에서의 스케줄링 결과를 절감된 전기요금으로 비교하겠다.

  • PDF

공동구내 분무분포에 관한 연구 (A Study on the Water Spray Distribution in Underground Culvert)

  • 김엽래
    • 한국방재학회 논문집
    • /
    • 제4권3호
    • /
    • pp.83-87
    • /
    • 2004
  • 지하공동구내에는 전력, 통신, 가스 냉 난방배관 등 생활에 필요한 공작물이 수용되어 있다. 미래에 지하 공동구의 사용은 확대되며, 화재의 위험이 증가될 것이므로 미연에 화재에 대비해야 하며, 지하공동구내 최대한의 연소방지효과를 가져오게 할 수 있는 소화시스템의 연구가 필요하다. 본 논문은 지하공동구내 화재를 진압하기 위한 노즐의 분무분포를 해석하고, 이에 따라 지하공동구의 화재안전성능을 확보하고자 한다. 앞으로 화재 및 재해예방을 위해 국내기술로서 국내 환경에 맞은 소화시스템 연구가 지속적으로 이루어져야 할 것이다.

대형 Community 건물의 연료전지 구동 지열원 히트펌프 냉.난방 시스템 성능에 관한 해석적 연구 (Analytical Study on the Performance of Fuel Cell Driven Ground Source Heat Pump Heating and Cooling System of a Large Community Building)

  • 변재기;정동화;최영돈;조성환
    • 설비공학논문집
    • /
    • 제21권6호
    • /
    • pp.355-366
    • /
    • 2009
  • In the present study, fuel cell driven ground source heat pump system is applied to a large community building and performance of the heat pump system is computationally analyzed. Conduction heat transfer between brine pipe and ground is analyzed by TEACH code to predict the performance of heat pump system. Predicted COP of the heat pump system and the energy cost were compared with variation of the location of the objective building the water saturation rate of soil and the driven powers of heat pump system. Significant reduction of energy cost can be accomplished by employing the fuel cell driven heat pump system in comparison with the late-night electricity driven system. It is due to the low electricity production cost of fuel cell system and the application of recovered waste heat generated during electricity production process to the heating of large community building.