• Title/Summary/Keyword: 냉방에너지

Search Result 382, Processing Time 0.023 seconds

Solar Cooling Technology (태양열 냉방 시스템)

  • Baek, Nam-Choon
    • Solar Energy
    • /
    • v.18 no.2
    • /
    • pp.31-49
    • /
    • 1998
  • Four main solar cooling technologies have been developed over the past twenty years are considered in this paper. These technologies include absorption, vapor compression, desiccant, adsorption, etc. All of these solar cooling technologies considered here are solar thermal ones. The destails of the thermodynamic cycle of these solar cooling technologies are given. The general concept of these solar cooling and the relative advantages among them are also presented. At last, the status and outlook for each approach are summarized.

  • PDF

Effects of Control Methods of Outdoor Air Cooling System on Energy Consumption in Building (외기냉방 시스템의 제어방법이 에너지 소비량에 미치는 영향에 관한 연구)

  • Hwang, Jin-Won;Ahn, Byung-Cheon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4253-4259
    • /
    • 2015
  • In this study, the effects of various control methods of outdoor air cooling control system on control characteristics and energy consumption in building are researched by simulation. The system analysis modelling is done by using TRNSYS program package, and the control performances with existing outdoor air cooling methods are compared with the control ones without outdoor air cooling. As a result, appropriate operating temperature conditions of outdoor air cooling system according to outdoor temperature changes are required, and the outdoor air/return air dry bulb temperature comparison control method among the control methods shows best responses in energy savings.

Thermoeconomic Analysis of Hybrid Desiccant Cooling System Driven by District Heating (지역난방에 연계된 하이브리드 제습냉방시스템의 경제성 분석)

  • Ahn, Joon;Kim, Jaeyool;Kang, Byung Ha
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.9
    • /
    • pp.721-729
    • /
    • 2014
  • A hybrid desiccant cooling system (HDCS) that uses a heat pump driven by district heating instead of a sensible rotor can provide an increased energy efficiency in summer. In this paper, the summer operation costs and initial costs of both the HDCS and traditional systems are analyzed using annual equal payments, and national benefits are found from using the HDCS instead of traditional systems. In the analysis results, the HDCS reduces the operation cost by 30 compared to the traditional systems, and each HDCS unit has 0.079 TOE per year of primary energy savings and 0.835 $TCO_2$ per year of $CO_2$ emission reduction more than the traditional systems. If HDCSs were to be installed in 680,000 households by 2020, this would produce a replacement power effect of 463 MW. Despite this savings effect, HDCSs require a government subsidy before they can be supplied because the initial cost is higher than that of traditional systems. Thus, this paper calculates suitable subsidies and suggests a supply method for HDCSs considering the national benefits.

Projection of Future Heating and Cooling Degree Days over South Korea under the IPCC SRES Scenarios: An Experiment with CCSM3 and MM5 Models (IPCC SRES 시나리오에 따른 우리나라의 미래 냉난방도일 전망: CCSM3와 MM5 모델 활용)

  • Choi, Jin Young;Song, Chang Kun;Kim, Deok Rae;Hong, Sung Chul;Hong, Yoo Deog;Lee, Jae Bum
    • Journal of Climate Change Research
    • /
    • v.4 no.2
    • /
    • pp.141-158
    • /
    • 2013
  • In this study, the projection of future heating and cooling degree days (HDDs and CDDs) has been conducted over South Korea for the period 1996~2005 with 2046~2055 and 2091~2100, using CCSM3 and MM5 simulations driven by the six IPCC SRES emission scenarios (A2, A1B, A1FI, A1T, B1, and B2). Annual mean surface air temperature increases by $1.2{\sim}3.4^{\circ}C$ at the end of the 21st century comparing to the present-day (1996~2005) in South Korea. HDDs decrease by 8~25% and CDDs increase up to 242~1,448% with corresponding changes in temperature. These increases and decreases also change the duration of HDDs and CDDs. HDDs duration decreases by 1 month, while the expansion of CDDs duration is much longer than 2 months. Thus, projected future HDDs and CDDs changes appear that cooling energy demand in summer season would increase and heating energy demand in winter would decrease in the future. Especially, these remarkable changes would be obvious at high mountain area, Gangwon-do and at south area, Jeju island. In the sense of future energy supply and policy, electrical energy for cooling in summer could be getting much more its importance rather than fossil energy used for heating in winter.

R&D Trend in desiccant based dehumidification and hybrid cooling system (건조제(desiccant)를 이용한 제습 및 복합냉방 시스템의 기술개발동향)

  • 박문수
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.27 no.6
    • /
    • pp.533-540
    • /
    • 1998
  • 최근에 국내외 에너지 이용 효율성 증대 문제, CFCs등으로 인한 오존층 파괴문제, $CO_2$ 등으로 인한 지구온난화 문제, 실내공기질(IAQ)과 관련된 건물 환기량 증대요구로 인한 건물용 공조시스템(HVAC)의 설계변경 문제 등으로 인해 다양한 종류의 대체 냉방기기가 연구되어 오고 있다. 현재 미국에서는 ASHRAE Standard 62-1989에 의해 실내거주자의 필요한 IAQ와 쾌적함을 유지하기 위해 환기량을 기존의 경우보다 약 3배 이상이 되도록 권장하고 있고 또한 대다수의 미국 주 정부에서 건물설계에 관련된 조례로 ASHRAE Standard 62-1989를 적용하고 있다. 따라서 빌딩공조 설비관계자들은 늘어난 환기 요구량에 따라 잠열냉방용량이 크게 증대되므로 이를 처리하기 위한 새로운 냉방공조기기 시스템기술에 대해 관심이 증대하고 있다. 이에 따라 건조제를 x이용한 냉방 및 제습 시스템이 대체 냉방시스템 또는 기존의 냉방 시스템과 더불어 잠열부하를 처리하는 복합 시스템으로 최근에 다시 상당한 주목을 받고 있다.

  • PDF