Operation of Brushless DC Motor without a Rotor Magnet Position Sensor (회전자극 위치센서 없는 Brushless DC전동기의 운전에 관한 연구)

  • 서석훈;엄우용
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.36T no.3
    • /
    • pp.50-55
    • /
    • 1999
  • Brushless DC Motor(BLDCM) has high efficiency. But this type of motor needs a rotor sensor which complicates the motor configuration. Rotor position sensor degrades system reliability in the severe environmental condition. In this paper, we study a controller which permits the determination of the rotor position by the back EMF to eliminate the rotor position sensor Also, since the back EMF is zero at standstill, a starting technique which permits the starting of an asynchronous motor without a sensor is described. The controller is implemented using microcontroller for minimal external component.

  • PDF

Evaluation of Software Diagnostics for Secure Operational Environment in Nuclear I&C systems (원전 계측제어 시스템 보안성환경을 위한 진단기능 평가)

  • Yoo, Sung Goo;Seul, Namo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.8
    • /
    • pp.107-112
    • /
    • 2016
  • Safety Critical Instrumentation and Control Systems perform those functions to maintain nuclear power plants' parameters within acceptable limits established for a design basis events and anticipated operating occurrence to ensure safety function. Those digitalized systems shall protect inadvertent and non-malicious behavior to ensure the reliable operation of systems, known as a Secure Development and Operational Environment(SDOE). SDOE would be established through managerial and technical controls. The objective of this paper is to evaluate the effectiveness of Cyclic Redundancy Checksum diagnostic, which is one of technical controls for SDOE, that can confirm the integrity of software of I&C systems to establish the secure environment. The results of this assessment would be the practical implementation of design and safety review of nuclear I&C systems.

Transformation of Antagonistic Pseudomonas stutzeri YPL-1 against Root Rotting Fungi Fusarium solani by Plasmid DNA (생물방제균 Pseudomonas stutzeri YPL-1의 형질전환 조건)

  • 김용수;김상달
    • Microbiology and Biotechnology Letters
    • /
    • v.18 no.5
    • /
    • pp.454-459
    • /
    • 1990
  • For the genetic multipurpose of antagonistic abilities of Pseudomom etutzeri YPL-1 aganist Fusarium solani causing root rot of many important crops by genetic engineering, optimal conditions for transformation of P-stutzeri YPL-1 by pKT230 were investigated. Maxium frequency of the transformation was achieved when cells were harvested at early exponential growth phase. The highest transformation efficiency was obtained when the competent cells were exposed to chilled transformation buffer containing 20 mM RbCI, 100 mM $CaCl_2$ and added l${\mu}g$/ml of plasmid DNA. The pH optimum for transformation was 6.5. When the bacterial cells that were incubated during 60 minutes for the competence were brought in contact with plasmid DNA, the transformations were obtained in the best frequency. It was formed that transformation frequency was 2 ~$6 \times 10^{-6}$ under the optimal conditions.

  • PDF

The Fundamental Studies of the New Glow Discharge/Inductively Coupled Plasma Interface: Part Ⅰ. Preliminary Studies (새로운 글로우 방전/유도결합 플라스마 장치(GD/ICP Interface)에 대한 기초 연구: Part Ⅰ. 기초 연구)

  • Lee, Gae Ho;Kil, Hyo Shik;Kim, Hyung Seung;Gary M. Hieftje
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.2
    • /
    • pp.182-192
    • /
    • 1999
  • The new GD/ICP-AES quick change over system has been developed and characterized. Within less than 15 minutes, ICP-AES could be switched to GD-AES and vise a versa. As a result, both solid and liquid samples could be analyzed in a very short period of time by the ICP/GD-AES quick change over system developed in our laboratory. The influences of the experimental variables, such as flow rate of coolant gas, flow rate of auxiliary gas, flow rate of sample carrier gas, sampling depth, orifice size of sampling cone, and rf (radio frequency) power on emission intensity have been presented. The detection limits of Cd(I) 228.8 nm, Mn (II) 257.61 nm, and Fe(II) 259.95 nm were found to be 3.86, 1.49, and 5.79 ppb, respectively. And linealities of the calibration curves were measured to be unity.

  • PDF

Development of In-Service Inspection Techniques for PGSFR (PGSFR 가동중검사기술 개발)

  • Kim, Hoe Woong;Joo, Young Sang;Lee, Young Kyu;Park, Sang Jin;Koo, Gyeong Hoi;Kim, Jong Bum;Kim, Sung Kyun
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.12 no.1
    • /
    • pp.93-100
    • /
    • 2016
  • Since the sodium-cooled fast reactor is operated in a hostile environment due to the use of liquid sodium as its coolant, advanced techniques for in-service inspection are required to periodically verify the integrity of the reactor. This paper presents the development of in-service inspection techniques for Proto-type Generation IV Sodium-cooled Fast Reactor. First, the 10 m long plate-type ultrasonic waveguide sensor has been developed for in-service inspection of reactor internals, and its feasibility was verified through several under-water and under-sodium experiments. Second, the combined inspection system for in-service inspection of ferromagnetic steam generator tubes has been developed. The remote field eddy current testing and magnetic flux leakage testing can be conducted simultaneously by using the developed inspection system, and the detectability was demonstrated through several damage detection experiments. Finally, the electro-magnetic acoustic transducer which can withstand high temperature and be installable in the remote operated vehicle has been developed for in-service inspection of the reactor vessel, and its detectability was investigated through damage detection experiments.

Preliminary Leak-before Break Assessment of Intermediate Heat Transport System Hot-Leg of a Prototype Generation IV Sodium-cooled Fast Reactor (소듐냉각고속로 원형로 중간열전달계통 고온배관의 파단전누설 예비평가)

  • Lee, Sa Yong;Kim, Nak Hyun;Koo, Gyeong Hoi;Kim, Sung Kyun;Kim, Yoon Jea
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.12 no.1
    • /
    • pp.126-133
    • /
    • 2016
  • Recently, the research and development of Sodium-cooled Fast Reactors (SFRs) have made progresses. However, liquid sodium, the coolant of an SFR, is chemically unstable and sodium fire can be occurred when liquid sodium leaks from sodium pipe. To reduce the damage by the sodium fire, many fire walls and fire extinguishers are needed for SFRs. LBB concept in SFR might reduce the scale of sodium fire and decrease or eliminate fire walls and fire extinguishers. Therefore, LBB concept can contribute to improve economic efficiency and to strengthen defense-in depth safety. The LBB assessment procedure has been well established, and has been used significantly in light water reactors (LWRs). However, an LBB assessment of an SFR is more complicated because SFRs are operated in elevated temperature regions. In such a region, because creep damage may occur in a material, thereby growing defects, an LBB assessment of an SFR should consider elevated temperature effects. The procedure and method for this purpose are provided in RCC-MRx A16, which is a French code. In this study, LBB assessment was performed for PGSFR IHTS hot-leg pipe according to RCC-MRx A16 and the applicability of the code was discussed.

Design and Fabrication of Low Cost Infrared Optical System Using Precision Glass Molding Lens Made by Chalcogenide Glass (칼코게나이드 유리 소재의 PGM 가공 렌즈를 사용한 저가의 적외선 광학계 설계와 제작)

  • Oh, Seung Eun;Lee, Sun Kyu;Choi, Joong Kyu;Song, Kook Hyun;Baek, Jong Sik
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.4
    • /
    • pp.154-158
    • /
    • 2012
  • In this paper, for low cost infrared optical equipment, we design and fabricate an infrared optical system for an uncooled detector using PGM(Precision Glass Molding) lenses. The designed infrared optical system has a good athermalization, and the material of all of its lenses is a chalcogenide glass suitable for the PGM method. In addition, we also fabricate the same infrared optical system using SPDT(Single Point Diamond Turning) lenses in order to measure the optical performance of PGM lenses. We measure the MTF(Modulation Transfer Function) of the two infrared optical systems which use the PGM lenses and the SPDT lenses. And then we compare and analyze the images of them both. As a result, we find that they have only a very small difference in optical performance. If the use of PGM lenses increases, we expect to reduce the cost of infrared optical equipment.

Synthesis and Crystal Structure of Asymmetric Dimer of 1,2-Benzothiazine Derivatives Using Silver Oxide (Silver Oxide를 이용한 1,2-벤조티아진 유도체의 비대칭 중합체 합성 및 결정 구조)

  • Park, Myung Suk
    • Journal of the Korean Chemical Society
    • /
    • v.42 no.6
    • /
    • pp.657-663
    • /
    • 1998
  • New asymmetric dimer, 7,7'-substituted (or H)-4-oxo-2,2'- dialkyl-l,l',2,2'-dibenzothiazine-3,3'dicarboxylic acid methyl ester-1,1,1',1'-tetraoxide 3,4'-yl ethers 2a-d were synthesized through the oxidative dimerization of 7-substituted (or H)-4-hydroxy-2-alkyl-1,2-benzothiazine-3-carboxylic acid methyl ester 1,1-dioxides la-d using silver oxide($Ag_2O$). 4-Oxo-2,2'-dialkyl-1,1'2,2'-dibenzothiazine-3,3'-dicarboxylic acid methyl ester-1,1,1',l'-tetraoxide 3,4'-yl ether 2c was identified by X-ray crystal structure determination.

  • PDF

Application of Response Surface Method for Modeling of Room Temperature Resistivity of $(Ba_{0.8-x}Sr_{0.2})Y_xTiO_3$ ($(Ba_{0.8-x}Sr_{0.2})Y_xTiO_3$의 상온비저항을 모델링하기 위한 반응표면분석법의 적용)

  • Moon, Hyung Chul;Noh, Tae Yong;Kim, Seung Won;Lee, Chul
    • Journal of the Korean Chemical Society
    • /
    • v.42 no.6
    • /
    • pp.652-656
    • /
    • 1998
  • $(Ba_{0.8-x}Sr_{0.2})Y_xTiO_3\;(BSYT)$ powders were prepared by the calcination of metal-oxalate precipitates, which were obtained by wet chemical method using Ba, Sr, Y and Ti-nitrates and oxalic acid. Yttrium content, sintering temperature and cooling rate were taken as experimental factors. Response surface method was applied to modelling of the room temperature resistivity of BSYT. The results indicated that the Yttrium content had larger effect on the room temperature resistivity and minimum room temperature resistivity was at Yttrium content of 0.24 mol%. The validity of a modelling equation was confirmed by comparing the measured room temperature resistivity with the calculated one.

  • PDF

Implementation of Position Sensorless Stroke Controller of Linear Compressors with Motor Parameter Identification (매개변수 추정기를 갖는 리니어 컴프레서의 위치센서리스 스트로크 제어기 구현)

  • Kim, Kwang-Ho;Nam, Jae-Woo;Kim, Gyu-Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.10
    • /
    • pp.173-179
    • /
    • 2014
  • In this paper, a motor parameter identification system has been implemented to improve the performance of the position sensorless stroke controller for linear compressors. In order to control the cooling capability of a refrigerator or an air conditioner in which linear compressors are applied, the piston speed should be controlled. The piston speed control can be obtained by adjusting the frequency or the stroke of linear motors. The dynamic performance of linear compressors depends on how accurately the stroke or the piston amplitude is estimated. The merits and demerits of Constant method and PIM (Parameter Identification Method) concerning the needed memory space and the stroke error are discussed and verified via some experimental studies.