• Title/Summary/Keyword: 냉각 회로

Search Result 279, Processing Time 0.037 seconds

Mineralogy and Geochemistry of the Jeonheung and Oksan Pb-Zn-Cu Deposits, Euiseong Area (의성(義城)지역 전흥(田興) 및 옥산(玉山) 열수(熱水) 연(鉛)-아연(亞鉛)-동(銅) 광상(鑛床)에 관한 광물학적(鑛物學的)·지화학적(地化學的) 연구(硏究))

  • Choi, Seon-Gyu;Lee, Jae-Ho;Yun, Seong-Taek;So, Chil-Sup
    • Economic and Environmental Geology
    • /
    • v.25 no.4
    • /
    • pp.417-433
    • /
    • 1992
  • Lead-zinc-copper deposits of the Jeonheung and the Oksan mines around Euiseong area occur as hydrothermal quartz and calcite veins that crosscut Cretaceous sedimentary rocks of the Gyeongsang Basin. The mineralization occurred in three distinct stages (I, II, and III): (I) quartz-sulfides-sulfosalts-hematite mineralization stage; (II) barren quartz-fluorite stage; and (III) barren calcite stage. Stage I ore minerals comprise pyrite, chalcopyrite, sphalerite, galena and Pb-Ag-Bi-Sb sulfosalts. Mineralogies of the two mines are different, and arsenopyrite, pyrrhotite, tetrahedrite and iron-rich (up to 21 mole % FeS) sphalerite are restricted to the Oksan mine. A K-Ar radiometric dating for sericite indicates that the Pb-Zn-Cu deposits of the Euiseong area were formed during late Cretaceous age ($62.3{\pm}2.8Ma$), likely associated with a subvolcanic activity related to the volcanic complex in the nearby Geumseongsan Caldera and the ubiquitous felsite dykes. Stage I mineralization occurred at temperatures between > $380^{\circ}C$ and $240^{\circ}C$ from fluids with salinities between 6.3 and 0.7 equiv. wt. % NaCl. The chalcopyrite deposition occurred mostly at higher temperatures of > $300^{\circ}C$. Fluid inclusion data indicate that the Pb-Zn-Cu ore mineralization resulted from a complex history of boiling, cooling and dilution of ore fluids. The mineralization at Jeonheung resulted mainly from cooling and dilution by an influx of cooler meteoric waters, whereas the mineralization at Oksan was largely due to fluid boiling. Evidence of fluid boiling suggests that pressures decreased from about 210 bars to 80 bars. This corresponds to a depth of about 900 m in a hydrothermal system that changed from lithostatic (closed) toward hydrostatic (open) conditions. Sulfur isotope compositions of sulfide minerals (${\delta}^{34}S=2.9{\sim}9.6$ per mil) indicate that the ${\delta}^{34}S_{{\Sigma}S}$ value of ore fluids was ${\approx}8.6$ per mil. This ${\delta}^{34}S_{{\Sigma}S}$ value is likely consistent with an igneous sulfur mixed with sulfates (?) in surrounding sedimentary rocks. Measured and calculated hydrogen and oxygen isotope values of ore-forming fluids suggest meteoric water dominance, approaching unexchanged meteoric water values. Equilibrium thermodynamic interpretation indicates that the temperature versus $fs_2$ variation of stage I ore fluids differed between the two mines as follows: the $fs_2$ of ore fluids at Jeonheung changed with decreasing temperature constantly near the pyrite-hematite-magnetite sulfidation curve, whereas those at Oksan changed from the pyrite-pyrrhotite sulfidation state towards the pyrite-hematite-magnetite state. The shift in minerals precipitated during stage I also reflects a concomitant $fo_2$ increase, probably due to mixing of ore fluids with cooler, more oxidizing meteoric waters. Thermodynamic consideration of copper solubility suggests that the ore-forming fluids cooled through boiling at Oksan and mixing with less-evolved meteoric waters at Jeonheung, and that this cooling was the main cause of copper deposition through destabilization of copper chloride complexes.

  • PDF

고습도 유닛쿨러를 사용하는 저온저장고의 배 저장효과

  • Yoon, Hong-Sun;Lee, Won-Ok;Jung, Hoon;Lee, Hyun-Dong
    • Proceedings of the Korean Society of Postharvest Science and Technology of Agricultural Products Conference
    • /
    • 2003.04a
    • /
    • pp.140-140
    • /
    • 2003
  • 신선한 채소나 과일은 무게의 74~94%에 상당하는 수분을 함유하고 있는데, 이러한 수분은 자칫하면 빠져나가기 쉽다. 품질이 우수한 채소나 과일이라도 수분손실이 생기면 다시는 보충할 수 없기 때문에 겉껍질을 마르고 쭈글쭈글하게 되어 품질등급과 가격결정에 손해가 된다. 또 무게의 5~l0%까지 수분이 줄어들면 상품성을 잃게되고, 무게단위로 판매되는 채소와 과일은 수분손실이 곧 무게감소이므로 총수입도 줄어드는 원인이 된다. 따라서 채소나 과일을 수확 한 후에 수분손실이 생기지 않도록 잘 관리하는 것은 농가소득과 직결되는 중요한 일이다. 그러나 기존의 저온저장고들은 저장고 내의 상대습도가 70~85%의 범위로 조성되고 있으며, 이러한 저습도의 문제를 해결하기 위하여 저장고의 바닥에 물을 뿌리는 등의 작업을 하고 있으나 문제가 해결되지는 않는다. 이에 따라 농업기계화연구소에서는 저온저장고 내의 상대습도를 90% 이상으로 유지할 수 있는 유닛쿨러를 '01년에 개발하였고,'02~'03년에 이것을 실제로 농가의 저온저장고에 설치하여 그 효과를 실증하였는데 그 결과를 요약하면 다음과 같다. 1. 현장연구에 사용된 저온저장고는 천안시에 있는 이진기 농가의 25평형 배 저온저장고 2동이었으며, 한 동은 시험구로 한 동은 대조구로 사용하였다. 2. 배의 저장온도는 0~-0.2$^{\circ}C$이었고, 상대습도는 대비 저온저장고의 경우 75~90% 범위에 있었으나 신기술투입 저온저장고에서는 98%로 유지되었다. 또 냉각기에 생기는 얼음을 제거하기 위해 작동되는 전기히터의 작동시간은 대비 저온저장고에서는 하루에 7회, 회당 45분 씩 이었고, 신기술 투입 저온저장고에서는 하루에 1회, 회당 30분 씩 이었다. 3. 배를 플라스틱 상자에 담아 저장할 때 대비 저온저장고에서는 111일 동안에 11.7%의 중량감모가 발생하였으나, 신기술투입 저온저장고에서는 5.6%의 중량감모만이 발생하여 약 50%의 중량감모를 줄일 수 있었으며, 배의 색깔이나 경도도 대비구 보다 우수하였다. 4. 배를 비닐로 포장하여 대비 저온저장고에 저장한 경우와 비닐로 포장하지 않고 신기술투입 저온저장고에 저장한 경우를 비교할 때 11월~다음해 1월 까지는 중량감모, 과피색깔 및 경도에 큰 차이가 없었으나, 2월부터는 비닐로 포장하여 대비 저온저장고에 저장한 배의 품질변화가 급격히 증가되어 중량감모, 과피색깔 및 경도가 신기술 투입시 보다 급속하게 나빠졌다.

  • PDF

A Study on Optical Properties of Aspheric Glass Lens using DLC Coated molding core (성형용 코어면 DLC 코팅에 의한 비구면 Glass렌즈 광학적 특성에 관한 연구)

  • Kim, Hyeon-Uk;Jeong, Sang-Hwa;Cha, Du-Hwan;Lee, Dong-Gil;Kim, Sang-Seok;Kim, Hye-Jeong;Kim, Jeong-Ho
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2007.07a
    • /
    • pp.243-244
    • /
    • 2007
  • 본 연구에서는 성형용 코어 가공에서 초경합금(WC, Co 0.5%)의 초정밀 가공특성을 파악하기 위하여 다이아몬드 휠의 메시, 주축 회전속도, 터빈 회전속도, 이송속도 및 연삭깊이에 따른 표면거칠기를 측정하여 최적연삭조건을 규명하였다. 규명된 최적연삭가공조건을 활용하여 페러렐 연삭법으로 초정밀 연삭가공을 수행하였다. 연삭가공은 초정밀가공기(ASP01, Nachi-Fujikoshi Co., Japan)를 사용하였다. 최종 정삭가공을 수행한 비구면 성형용 코어의 형상측정결과 형상정도(PV; ${\varphi}$ 3.0mm) 0.15${\mu}m$(비구면), 0.10${\mu}m$(평면)으로 3M급 이상의 고화질 카메라폰에 채용되고 있는 비구면 Glass렌즈 양산용 성형용 코어 규격에 만족한 결과로서 본 연구에 수행된 초정밀 가공조건 및 측정방법이 매우 유효함을 알 수 있었다. 형상정도(PV) 및 표면조도(Ra) 측정은 초정밀 자유곡면 측정기(UA3P, Panasonic Co., Japan)와 3차원 표면조도 측정기(NewView5000, Zygo Co., USA)를 각각 사용하였다. 초정밀 가공된 성형용 코어면에 이온증착법을 활용하여 DLC 코팅을 수행하였다. 코팅 전후의 성형용코어를 활용하여 Glass소재(K-BK7, Sumita Co., Japan)를 최적의 성형조건(성형온도, 압력, 냉각속도)으로 성형하였다. DLC 코팅과 성형은 DLC 코팅기(NC400, Nanotech Co., Japan)와 Glass렌즈 성형기(Nano Press-S, Sumitomo Co., Japan)을 각각 사용하였다. Fig. 1은 초정밀 연삭가공, DLC 코팅막 구조, 코팅된 성형용 코어, 그리고, 성형된 비구면Glass렌즈를 각각 나타낸다.

  • PDF

Properties of Rice Flour Prepared with Roll Mill and Pin Mill after Tempering (조질 후 Roll Mill과 Pin Mill의 제분 및 쌀가루의 특성)

  • 김형열;이병영;유효숙;최중경;함승시
    • Food Science and Preservation
    • /
    • v.6 no.3
    • /
    • pp.313-318
    • /
    • 1999
  • The Properties of rice flour and consumed electricity to make rice flour were compared among three different process ; 1. roll mill after soaking rice in water, 2. roll mill after tempering, 3. try pin mill. When rice was milled by roll mill and pin-milled after tempering for 10 hrs(TRPMR), consumed electricity and moisture content of rice flour were the least. Particle size of rice flour prepared with TRPMR was 87.4% of 100 mesh or more which was the highest number among the rice flour prepared using different processes. Gelatinization temperature of the rice flour was 63.2$^{\circ}C$ and was 1.3$^{\circ}C$ lower than that of rice flour prepared with other processes. Viscosity of the rice flour prepared by TRPMR was the least. Whiteness of the rice flour prepared by TRPMR was similar to that of wheat flour.

  • PDF

Implementation of a Simulation Tool for Monitoring Runtime Thermal Behavior (실시간 온도 감시를 위한 시뮬레이션 도구의 구현)

  • Choi, Jin-Hang;Lee, Jong-Sung;Kong, Joon-Ho;Chung, Sung-Woo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.14 no.1
    • /
    • pp.145-151
    • /
    • 2009
  • There are excessively hot units of a microprocessor in today's nano-scale process technology, which are called hotspots. Hotspots' heat dissipation is not perfectly conquered by mechanical cooling techniques such as heatsink, heat spreader, and fans; Hence, an architecture-level temperature simulation of microprocessors is evident experiment so that designers can make reliable chips in high temperature environments. However, conventional thermal simulators cannot be used in temperature evaluation of real machine, since they are too slow, or too coarse-grained to estimate overall system models. This paper proposes methodology of monitoring accurate runtime temperature with Hotspot[4], and introduces its implementation. With this tool, it is available to track runtime thermal behavior of a microprocessor at architecture-level. Therefore, Dynamic Thermal Management such as Dynamic Voltage and Frequency Scaling technique can be verified in the real system.

Analysis of Parameter Characteristic of Parallel Electrodes Conduction-cooled Film Capacitor for HF-LC Resonance (고주파 LC 공진을 위한 병렬전극 전도냉각 필름커패시터의 파라메타 특성 분석)

  • Won, Seo-Yeon;Lee, Kyeong-Jin;Kim, Hie-Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.6
    • /
    • pp.155-166
    • /
    • 2016
  • It is important to configure capacitance(C) of the capacitor and the induction coefficient(L) of the work coil on the resonant circuit design stage in order to induce heating on the object by a precise and constant frequency components in the electromagnetic induction heating equipment. Work coil conducts a direct induction heating according to heating point and area of the object which has a fixed heat factor so that work coil is designed to has fixed value. On the other hands, Capacitor should be designed to be changed in order to be the higher the utilization of the entire equipment. It is extracted the samples by variation of single electrode capacity from the selection stage of raw materials for capacity to the stage of process design for output of the high frequency LC resonance of 700kHz on 1000 VAC maximum voltage and current to $200I_{MAX}$. It is suggested fundamental experiment results in order to prove relation for the optimal design of HF-LC resonance conduction-cooled capacitor based on the response of frequency characteristics and results of output parameters according to variation of the capacitance size.

Uncooled Metallic Thin-film Thermopile Infrared Detector (비냉각 금속 박막형 열전퇴 적외선 검지기)

  • Oh, Kwang-Sik;Cho, Hyun-Duk;Kim, Jin-Sup;Lee, Yong-Hyun;Lee, Jong-Hyun;Lee, Jung-Hee;Park, Se-Il
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.2
    • /
    • pp.5-12
    • /
    • 2000
  • Uncooled metallic thin-film thermopile infrared detectors have been fabricated, and the figures of merit for the detectors were examined. The hot junctions of a thermopile were prepared on a $Si_{3}N_{4}/SiO_{2}/Si_{3}N_{4}$-membrane which acts as a thermal isolation layer, the cold junctions on the membrane supported with the silicon rim which functions as a heat sink, and Au-black was used as an infrared absorber. Infrared absorbance of Au-black, which strongly depends on the chamber pressure during Au-evaporation and its mass per area, was found to be about 90 % in the wavelength range from 3${\mu}{\textrm}{m}$ to 14${\mu}{\textrm}{m}$. Voltage responsivity, noise equivalent power, and specific detectivity of Bi-Sb thermopile infrared detector at 5 Hz-chopping frequency were about 10.5V/W, 2.3 nW/Hz$^{1/2}$, 및 $1.9\times10^{7}$ cm.Hz$^{1/2}$/w at room temperature in air, respectively.

  • PDF

Real-Time Fixed Pattern Noise Suppression using Hardware Neural Networks in Infrared Images Based on DSP & FPGA (DSP & FPGA 기반의 적외선 영상에서 하드웨어 뉴럴 네트워크를 이용한 실시간 고정패턴잡음 제어)

  • Park, Chang-Han;Han, Jung-Soo;Chun, Seung-Woo
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.46 no.4
    • /
    • pp.94-101
    • /
    • 2009
  • In this paper, we propose design of hardware based on a high speed digital signal processor (DSP) and a field programmable gate array (FPGA) for real-time suppression of fixed pattern noise (FPN) using hardware neural networks (HNN) in cooled infrared focal plane array (IRFPA) imaging system FPN appears a limited operation by temperature in observable images which applies to non-uniformity correction for infrared detector. These have very important problems because it happen serious problem for other applications as well as degradation for image quality in our system Signal processing architecture for our system operates reference gain and offset values using three tables for low, normal, and high temperatures. Proposed method creates virtual tables to separate for overlapping region in three offset tables. We also choose an optimum tenn of temperature which controls weighted values of HNN using mean values of pixels in three regions. This operates gain and offset tables for low, normal, and high temperatures from mean values of pixels and it recursively don't have to do an offset compensation in operation of our system Based on experimental results, proposed method showed improved quality of image which suppressed FPN by change of temperature distribution from an observational image in real-time system.

Vibration Test for PCB/Connector Assembly (인쇄회로기판 진동이 커넥터에 미치는 영향)

  • 허남일;김성철;송규섭
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.160-164
    • /
    • 1995
  • 정보통신 시스템의 고속/고밀도화 요구에 따라 개발되고 있는 ATM(Asynchronous Transfer Mode) 교환기 시스템은 팬을 이용한 강제대류냉각 방식의 채택과 시스템이 설치되는 장소에 따른 여러 환경조건에 의한 진동 문제가 발생될 수 있다. 시스템의 진동으로 인한 피해중 커넥터 접촉부에서 전기적 특성의 변화는 고속으로 전송되는 신호의 왜곡을 유발시킬 수 있어 시스템 개발시 이에 대한 충분한 연구 및 시험이 요구되고 있다. 진동환경에서 커넥터 접촉부는 접촉면의 상대운동으로 인한 접촉저항의 증가와 순간적인 신호전달 중단을 가져오게 되며, 특히 PCB/Connector Assembly에서 커넥터 접촉부는 PCB(Printed Circuit Board)의 장착 조건 및 동적 거동에 따라 전기적 특성이 변할 수 있다. 시스템에서 커넥터의 동적 거동을 이해하기 위해서는 PCB를 포함하는 시스템내 여러 요소의 동적 특성 이해와 복잡한 해석과정이 요구되며, 시스템 개발자는 진동 환경에서 이것의 시험 결과에 따라 커넥터의 사용을 결정해야 할 것이다. 커넥터의 전기적 특성 시험법은 IEC, EIA드 여러 국제 규격에 제시되어 있으며, 본 연구의 대상이 된 ATM교환기 시스템에서 PCB/Connector Assembly의 진동환경에서 접촉저항 측정과 관련된 접촉저항 임계치 및 측정법은 IEEE 규격 및 Bellcore 규격에 규정되어 있다. Bellcore에는 주어진 진동시험주기 전후에 IEC 규격의 LLCR(Low Level Contact Resistance) 측정회로를 이용한 측정법이 규정되어 있고, 냉각팬 및 주위 환경진동이 가해지는 동안의 영향에 대한 시험법은 규정되어 있지 않다. 본 연구에서는 한국통신의 전자장비 운용환경시험 조건의 진동에서 ATM 교환기 시스템에 사용되는 PCB/Connector Assembly 커넥터 접촉부의 접촉저항 변화와 PCB 진동에 의한 영향을 시험하였다.proach)등이 제시되었고 평면파 영역에 한하여 해서되어져 왔다. 본 논문에서는 분할 접근 방법(Segmentation Approach)을 이용하여 다공 요소로 이루어진 소음기를 해석하는데 적용하였다.로 성능 및 안정도에 영향을 미치므로 주의 깊게 선정해야 한다. 방법의 실질적인 적용에는 어려움이 있다. 본 연구에서는 기존의 방법들의 단점을 극복할 수 있는 새로운 회귀적 모우드 변수 규명 방법을 개발하였다. 이는 Fassois와 Lee가 ARMAX모델의 계수를 효율적으로 추정하기 위하여 개발한 뱉치방법인 Suboptimum Maximum Likelihood 방법[5]를 기초로 하여 개발하였다. 개발된 방법의 장점은 응답 신호에 유색잡음이 존재하여도 모우드 변수들을 항상 정확하게 구할 수 있으며, 또한 알고리즘의 안정성이 보장된 것이다.. 여기서는 실험실 수준의 평 판모델을 제작하고 실제 현장에서 이루어질 수 있는 진동제어 구조물에 대 한 동적실험 및 FRS를 수행하는 과정과 동일하게 따름으로써 실제 발생할 수 있는 오차나 error를 실험실내의 차원에서 파악하여 진동원을 있는 구조 물에 대한 진동제어기술을 보유하고자 한다. 이용한 해마의 부피측정은 해마경화증 환자의 진단에 있어 육안적인 MR 진단이 어려운 제한된 경우에만 실제적 도움을 줄 수 있는 보조적인 방법으로 생각된다.ofile whereas relaxivity at high field is not affected by τS. On the other hand, the change in τV does not affect low field profile but strongly in fluences on both inflection fie이 and the maximum relaxivity value. The results shows a fluences on both inflection field and the maximum relaxivity v

  • PDF

Geochemistry of Cu-Pb-Zn-Ag Deposits from the Euiseong Mineralized Area (의성 광화대 동-연-아연-은 광상의 지화학적 연구)

  • Chi, Se-Jung;Doh, Seong-Jae;Choi, Seon-Gyu;Lee, Jae-Ho
    • Economic and Environmental Geology
    • /
    • v.22 no.3
    • /
    • pp.253-266
    • /
    • 1989
  • The Cu-Pb-Zn-Ag hydrothermal vein type deposits which comprise the Dongil and Dong-cheogogsan mines occur within the Cretaceous sedimentary rocks in the Euiseong Basin of the southern Korean peninsula. The ore mineralization is contained within three stage(I,II and III) quartz and calcite veins. Ore minerals occur as dominant chalcopyrite, galena, sphalerite, tetrahedrite and Pb, Ag, Sb and Bi-bearing sulfosalts. Stage I ore minerals were deposited between $400^{\circ}C$ and $200^{\circ}C$ from the fluid with moderate salinities(7.0 to 4.5 eq. wt. % NaCl). Evidence of boiling suggests pressure of less than 150 bars during stage I mineralization. This pressure corresponds to maximum depths of 650 m and 1700 m, respectively, assuming lithostatic and hydrostatic loads. The data on mineralogy, temperature and salinity, together with information on the solubility of Cu complex, suggest that Cu deposition is a result of boiling coupled with declining temperature from $350^{\circ}$ to $250^{\circ}C$ or declining log $a_{o_2}$(from -29.8 to -35.9 atm.)and increasing in pH. Pb, Ag, Sb and Bi-bearing sulfosalts were deposited by cooling and dilution at temperature of less than $250^{\circ}C$ from the ore fluid with less than -35.9 atm. of log $a_{o_2}$.

  • PDF