• Title/Summary/Keyword: 냉각효율

Search Result 584, Processing Time 0.025 seconds

Solar Photovoltaic According to Installation of Cooling System (냉각시스템에 의한 태양광 발전의 효율 개선)

  • Yum, Sung-Bae;Choi, Hong-Kyoo;Choi, Young-Jun;Hong, Seong-Goo;Kim, Tae-Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.5
    • /
    • pp.66-71
    • /
    • 2009
  • The solar photovoltaic power generator can get more power with the higher solar radiation quantity. However, if the higher solar radiation quantity on cell becomes high temperature, the efficiency of generate will be reduced. To install cooling system for this kind of device can be the way to solve high temperature problem on cell but another problems after install it such as increasing of solar generated quantity problem cost to install cooling system and cost to be maintained cooling system weren't discussed to practical use this system. So the present paper described about effect and commercial business possibility of cooling system. After installing a cooling system the results of experiment about 5.76[%] average annual increasing of solar photovoltaic can expect.

Axisymmetric Thermal Analysis of 3D Regenerative Cooling System (3차원 재생 냉각 시스템의 축대칭 열해석)

  • Kim Sung-In;Park Seung-O
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.10 no.2
    • /
    • pp.53-61
    • /
    • 2006
  • Axisymmetric numerical thermal analysis for a 3-dimensional regenerative cooling system in a rocket engine is carried out. To predict the accurate heat transfer with the stiff temperature distribution, several tests have been conducted for the grid size, the properties variation of the coolant and the combustion gas depending on temperature. The axisymmetric heat flux model is defined using fin efficiencies and is designed to be equivalent to the heat flux of the 3-dimensional coolant channel. For comparison purpose, the 1-dimensional analysis using Bartz equation is also conducted. The performance of the present model in predicting the cooling characteristics of a 3-dimensional regenerative cooling system is compared with the 3-dimensional results of RTE(Rocket Thermal Evaluation). It is found that the present method predicts much closer results to those of RTE code than 1-dimensional analysis.

Effect of Mainstream Turbulence Intensity on Film Cooling of Combustor (연소기 벽면 막냉각에 주유동의 난류강도가 미치는 영향)

  • Kim Young Bong;Rhee Dong Ho;Cho Hyung Hee;Hahm Hee-Cheol;Bae Ju Chan;Oh Min Geun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.132-136
    • /
    • 2004
  • Experimental study has been conducted to investigate effect of mainstream turbulence intensity on film cooling performance of staggered rows of rectangular holes in combustor. Temperature fields and adiabatic film cooling effectiveness under $10\%$ mainstream turbulence intensity are measured. The results of temperature fields show that overall values are decreased and thicker film of coolant is formed downstream of rows of holes for high mainstream turbulence intensity. The results of film cooling effectiveness show that the values around the holes are smaller than the case of the low mainstream turbulence intensity, however, the difference of film cooing performance is decreasedforthefurtherdownstream.

  • PDF

Influence of the Vertical Flame holder on Heat Transfer Characteristics of Ramjet Combustor (세로축 화염안정기 형상이 램제트 연소실에서의 열전달 특성에 미치는 영향)

  • Yang, Kang-Mo;Lee, Keon-Woo;Song, Ji-Woon;Cho, Hyung-Hee;Hwang, Ki-Young
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.305-309
    • /
    • 2008
  • This experimental study has been conducted to investigate the installation of the vertical flame holder shape in ramjet combustor, which affects on the film cooling effectiveness. All slot position, the film cooling effectiveness decreases because of the shear layer and high turbulence intensity between separated flows and coolant flows. When the flame holder is installed, film cooling effectiveness decreases abruptly on the beginning of the slot exit region due to the mixing effect. As the blowing rate increases, the film cooling effectiveness is increased for all cases due to the augmented momentum of injected coolant from the slot.

  • PDF

Effect of Heat Transfer and Phase Change of Coolant on the Performance of Mixed-gas Ejection System (냉각제의 분사조건 및 상변화가 혼합가스 사출시스템의 성능에 미치는 영향)

  • Kim, Hyun Muk;Kim, Jeong Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.6
    • /
    • pp.84-93
    • /
    • 2018
  • Three-dimensional (3D) numerical simulations have been carried out to study how coolant injection conditions influence the cooling efficiency and projectile ejection performance in a mixture-gas ejection system (or gas-steam launch system). The 3D single-phase computational model was verified using a 1D model constructed with reference to the previous research and then a two-phase flow computation simulating coolant injection on to hot gas was performed using a DPM (Discrete Phase Model). As a result of varying the coolant flow rate and number of injection holes, cooling efficiency was improved when the number of injection holes were increased. In addition, the change of the coalescence frequency and spatial distribution of coolant droplets caused by the injection condition variation resulted in a change of the droplet diameter, affecting the evaporation rate of coolant. The evaporation was found to be a critical factor in the design optimization of the ejection system by suppressing the pressure drop while the temperature decreases inside the breech.

Numerical Analysis of Heat Transfer Characteristics of Ribbed Channels with Different Film Cooling Hole Position (필름 냉각을 위한 리브드 채널의 홀 위치에 따른 열전달 특성 수치 해석)

  • Park, Jee Min;Moon, Joo Hyun;Lee, Hyung Ju;Lee, Seong Hyuk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.69-76
    • /
    • 2018
  • The present study analyzed the effect of film hole position of 45 degree ribbed cooling channel on film cooling performance of gas turbine blades. We also investigated the influence of the ribs under the fixed blowing ratio. Three-dimensional numerical model was constructed and extensive simulation was conducted using the commercial code (Fluent ver. 17.0) under steady-state condition. Base on the simulation results, We investigated the cooling effectiveness, flow velocity, streamline, and pressure coefficient. Moreover, We analyzed the effect of cooling hole position on ejection of the secondary flow caused by the rib structure. From the results, It was found that internal flow of the cooling channel forms a vortex pair in the counterclockwise from the top side, and clockwise from the bottom side. For the channels with ribs, the vortex flow generated by the ribs caused a higher pressure difference near the hole outlet, resulting in at least 12% higher cooling effectiveness than the channel without ribs. Additionally, when the hole is located on the left side of the ribbed channel (Rib-Left), it can be found that the secondary flow generated by the ribs hits against wall surface near the hole to form a flow in the direction of the hole inclination angle. Therefore, It is considered that the region where the cooling gas discharged to the blade surface stays in the main flow boundary layer is wider than the other cases. In this case, The largest pressure coefficient difference was observed near the outlet of the hole, and as a result, the discharge of the cooling gas was accelerated and the cooling efficiency was slightly increased.

모터내장형 주축의 냉각특성에 관한 연구

  • 송영찬;이득우;최대봉;김수태
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.626-630
    • /
    • 1995
  • 최근산업의 발달과 함께 제품의 생산성 및 품질 향상을 위하여 공작기계의 고속화 기술에 대한 연구가 머시닝센터를 중심으로 활발히 진행되고 있다. 공작기계의 고속화에 적합한 주축시스템으로는 모터내장형 주축(Built-in Motor Type Spindle)이 많이 응용되고 있으며, 앞으로더욱 수요가 증대될 것이 예상되어 독일, 일본 등의 선진국에서도 활발히 연구 개발이 이루어지고 있다. 본 연구에서는 모터발열을 억제하기 위한 냉각방법으로 오일자켓 냉각방식을 채택하여 모터부에 자켓을 설치, 운전함으로써 모터내장형 주축에 대한 오일자켓냉각방식의 냉각특성을 알아보고, 또한 모터부의 오일자켓 냉각과 함께 몇가지 방법으로 공기냉각을 추가하였을 때의 냉각특성을 고찰하여 보다 효율적인 냉각방법을 제시하고자 한다.

냉각장치의 고장징후에 대한 전문가시스템의 개발-크실렌 산화 공정을 중심으로-

  • 심종칠;김창은;주용준
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1996.04a
    • /
    • pp.717-722
    • /
    • 1996
  • 본 연구는 위험성이 큰 화학플랜트에서 크실렌 산화공정의 냉각계통에 잠재한 위험성을 HAZOP (Hazard and Operability Studies) 기법을 통하여 잠재한 위험공정부분을 미연에 파악하고 이를 평가하여 안전의 효율성을 높이며, 또한 평가후 이를 전문가시스템을 통하여 취약점을 미연에 파악할 수 있도록 냉각장치의 전문가시스템을 제시하고자 한다.

  • PDF

Modeling of Cooling Channels of Injection Mould using Functionally Graded Material (기능성 경사 복합재를 이용한 사출금형의 냉각회로 모델링)

  • Shin, Ki-Hoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.12
    • /
    • pp.1647-1653
    • /
    • 2011
  • The cycle time in injection moulding greatly depends on the cooling time of the plastic part that is controlled by cooling channels. Cooling channels are required to facilitate the heat transfer rate from the die to the coolant without reducing the strength of the die. Employing layered manufacturing techniques (LMT), a die embedding conformal cooling channels can be fabricated directly while conventional cooling channels are usually made of straight drilled hole. Meanwhile, H13 tool steel is widely used as the die material because of its high thermal resistance and dimensional stability. However, H13 with a low thermal conductivity is not efficient for certain part geometries. In this context, the use of functionally graded materials (FGMs) between H13 and copper may circumvent a tradeoff between the strength and the heat transfer rate. This paper presents a method for modeling of conformal cooling channels made of FGMs.

Heat Transfer Characteristics under Recirculation zone of Ramjet Combustor (재순환 영역이 램제트 연소실에서의 열전달 특성에 미치는 영향)

  • Lee, Keon-Woo;Oh, Min-Keun;Ham, Hee-Chul;Hwang, Ki-Young;Cho, Hyung-Hee
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.11 no.6
    • /
    • pp.9-17
    • /
    • 2007
  • This experimental study has been conducted to investigate the effect of the recirculation zone on the multi-slot film cooling in the ramjet combustor. The recirculation zone which is generated by the protrusion tip on the entrance of the coolant flow path affects on the first slot. Velocity fields, dimensionless temperature fields and adiabatic film cooling effectiveness on the downstream wall of the slot exit are measured. The results show that the film cooling performance is rapidly decreased after the slot exit by shear layer and high turbulence intensity between separated flows and coolant flows.